Transition E-100BTX-FX-06 User manual

33791Rev.Ahttps://www.transition.com/Page1of13
E‐100BTX‐FX‐06
Stand‐AloneMediaConverter
UserGuide
FastEthernet
CoppertoFiber
100Base‐TXto100Base‐FX
ActiveLinkPassThrough,Far‐End‐FaultDetection,andPause
Auto‐Negotiation,Auto‐MDI/MDIX,andAutomaticLinkRestoration
Contents
Introduction..................................................................................................................................................................1
OrderingInformation...............................................................................................................................................2
Accessories...............................................................................................................................................................2
FamilyPortrait..........................................................................................................................................................3
Installation....................................................................................................................................................................4
4‐PositionDIPSwitch................................................................................................................................................4
InstallingtheFiberCable..........................................................................................................................................5
InstallingtheCopperCable......................................................................................................................................5
PoweringtheMediaConverter................................................................................................................................6
Operation......................................................................................................................................................................6
StatusLEDs...............................................................................................................................................................6
Auto‐Negotiation......................................................................................................................................................6
PauseControl...........................................................................................................................................................6
AutoMDI/MDIX........................................................................................................................................................6
ActiveLinkPass‐Through(ALPT)..............................................................................................................................7
Far‐EndFault............................................................................................................................................................8
Specifications................................................................................................................................................................8
CableSpecifications..................................................................................................................................................8
TechnicalSpecifications..........................................................................................................................................10
Troubleshooting..........................................................................................................................................................11
ContactUs...................................................................................................................................................................12
ComplianceInformation.............................................................................................................................................12
DeclarationofConformity......................................................................................................................................12
RecordofRevisions.....................................................................................................................................................13
Introduction
TransitionNetworksE‐100BTX‐FX‐06FastEthernetmediaconvertersconnect100Base‐TXshieldedorunshielded
twisted‐paircoppercableto100Base‐FXfiber‐opticcable.
TheE‐100‐TBX‐FX‐06converterfamilyofsimple“Plug‐and‐Play”converterscanbeusedattheedgeofanetwork
toprovideFastEthernetconnectionsfordevicesinchallenginglocations.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttps://www.transition.comPage2of13
OrderingInformation
Part Number Port One - Copper
100Base-TX Port Two - Fiber -
100BaseFX
E-100BTX-FX-06(SFP) RJ-45
100 m (328 ft)* Open SFP Slot (supports100MbpsSFPmodules)
E-100BTX-FX-06 RJ-45
100 m (328 ft)* ST, 1300 nm multimode
2 km (1.2 miles)*
E-100BTX-FX-06(SC) RJ-45
100 m (328 ft)* SC, 1300 nm multimode
2 km (1.2 miles)*
E-100BTX-FX-06(LC) RJ-45
100 m (328 ft)* LC, 1300 nm multimode
2 km (1.2 miles)*
E-100BTX-FX-06(SM) RJ-45
100 m (328 ft)* SC, 1300 nm multimode
20 km (12.4 miles)*
E-100BTX-FX-06(SMLC) RJ-45
100 m (328 ft)* LC, 1300 nm single mode
20 km (12.4 miles)*
* Typical maximum cable distance. Actual distance depends on the physical characteristics of the network
installation. For more information, see https://www.transition.com/.
Accessories
Accessoriesaresoldandpackagedseparately.
PartNumberDescription
SPS‐2460‐SAOptionalExternalPowerSupply;24‐60VDCand24‐42VRMS
Stand‐AloneWide‐Input;Output:12.25VDC,1.0A
E‐MCR‐0512‐SlotMediaConverterRack(includesuniversalinternalpowersupply)
17x15x5in.(432x381x127mm)
RMS19‐SA4‐024‐SlotMediaConverterShelf
WMBLOptionalWallMountBrackets;4.0in.(102mm)
WMBVOptionalVerticalMountBracket;5.0in.(127mm)
WMBDOptionalDINRailMountBracket;5.0in.(127mm)
WMBD‐FSOptionalDINRailMountBracket(flat,small);3.1in.(79mm)
SFPsSeetheTransitionNetworksSFPwebpageforourfulllineofSFPs.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttp://www.transition.com/Page3of13
FamilyPortrait

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttps://www.transition.comPage4of13
Installation
Caution:Wearagroundingdeviceandobserveelectrostaticdischargeprecautionswhensettingthe
4‐positionDIPswitchandjumpers.Failuretoobservethiscautioncouldresultinfailureofthemediaconverter.
4‐PositionDIPSwitch
The4‐positionDIPswitchislocatedonthesideofthemediaconverter.Useasmallflat‐bladescrewdriverora
similartooltosettherecessedswitches.
1.Auto‐Negotiation
Up EnablesAuto‐Negotiationforthecopperconnection.
DownDisablesAuto‐Negotiationforthecopperconnection.
2.PauseControl
Up Enabled
DownDisabled
3.ActiveLinkPass‐Through
Up Enabled
DownDisabled
4.Far‐EndFault
Up Enabled
DownDisabled
Note:ThemediaconvertersareshippedfromthefactorywithallDIPswitchesintheUp(enabled)position.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttp://www.transition.com/Page5of13
InstallingtheFiberCable
1.Locatea100Base‐FXcompliantfibercablewithmale,two‐strandedTXtoRXconnectorsinstalledatbothends.
2.Connectthefibercablestothemediaconverterasdescribed:
•ConnectthemaleTXcableconnectortothefemaleTXport.
•ConnectthemaleRXcableconnectortothefemaleRXport.
3.Connectthefibercablestotheotherdevice(anothermediaconverter,EthernetSwitch,etc.)asdescribed:
•ConnectthemaleTXcableconnectortothefemaleRXport.
•ConnectthemaleRXcableconnectortothefemaleTXport.
InstallingtheCopperCable
1.Locatea100Base‐TXcompliantcoppercablewithmale,RJ‐45connectorsinstalledatbothends.
2.ConnecttheRJ‐45connectoratoneendofthecabletotheRJ‐45portonthemediaconverter.
3.ConnecttheRJ‐45connectorattheotherendofthecabletotheRJ‐45portontheotherdevice(switch,
workstation,etc.).

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttps://www.transition.comPage6of13
PoweringtheMediaConverter
PowerCordIncluded:toorderthecorrespondingcountry‐specificACpowercord,addtheCountryCode
extensiontotheendoftheSKU;NA=NorthAmerica,LA=LatinAmerica,EU=Europe,UK=UnitedKingdom,
SA=SouthAfrica,JP=Japan,OZ=Australia,BR=Brazil.
AC
1.Installthepowercordbarrelconnectorintothebackofthemediaconverter.
2.ConnectthepoweradapterplugintoACpower.
3.VerifythatthemediaconverterispoweredupbynotingthatthepowerLEDislit.
DC
SeetheSPS‐2460‐xxDCExternalPowerSupplyUserGuide33455formoreinformation.
Operation
StatusLEDs
UsethestatusLEDstomonitortheE‐100BTX‐FX‐06mediaconverteroperationinthenetwork:
LEDDescriptionMeaning
Power PowerOn=ConnectedtoexternalACpower.
SDFSignalDetect/FiberOn=Fiberlinkisdetected.
SDCSignalDetect/CopperOn=Copperlinkisdetected.
RXCReceive/CopperFlashing=Asignalisbeingreceivedonthecopperlink.
RXFReceive/Fiber Flashing=Asignalisbeingreceivedonthefiberlink.
Auto‐Negotiation
WhentheAuto‐Negotiationfeatureisactivated,themediaconverterconfiguresitselftoachievethebestpossible
modeofoperationoveralink,automatically.Themediaconverterbroadcastsitsspeed(100Mb/s)andduplex
capabilities(eitherfullorhalf‐duplex)andnegotiatesthebestmodeofoperationbetweenthetwodevices.
PauseControl
ThePausefeaturecanimprovenetworkperformancebyallowingoneendofthelinktosignaltheotherto
discontinueframetransmissionforasetperiodoftimetorelievebuffercongestion.
Note:IfthePausefeatureisavailableonALLnetworkdevicesattachedtothemediaconverter(s),enablethe
Pausefeatureonthemediaconverter(s);otherwise,disablethePausefeature.
AutoMDI/MDIX
TheAutoMDI/MDIXfeatureallowseitherstraight‐through(MDI)orcrossover(MDI‐X)cablestobeusedwhen
connectingtodevicessuchashubs,transceivers,ornetworkinterfacecards(NICs).AutoCrossdeterminesthe
characteristicsofthecableconnectionandautomaticallyconfigurestheunittolinkup,regardlessofthecable
configuration.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttp://www.transition.com/Page7of13
ActiveLinkPass‐Through(ALPT)
LinkPass‐Throughisatroubleshootingfeaturethatallowsthemediaconvertertomonitorboththefiberand
copperRXportsforlossofsignal.WiththelossofRXsignalononemediaport,theconverterwillautomatically
disabletheTXsignaloftheothermediaport,thus“passingthrough”thelinkloss.
Enddeviceautomaticallynotifiedoflinkloss
Preventslossofvaluabledataunknowinglytransmittedoverinvalidlink
ActiveLPTisaformofLPTthatrequiresthelinkstobecomeActivebeforeLPTbecomesActive.
WithActiveLPTthereare2states:DiagnosticandActive.
ThemediaconverterenterstheDiagnosticstatewheneitherofthefollowingconditionsismet:
Uponpower‐upoftheconverter.
UponlosingLinkoneitherthecopperorfiberports.
IntheDiagnosticstate,thelinkforeachofthemediaconverter’sportscancomeupindependentlyofeachother,
justlikeaconverterthathasnoLPTfunctionality,oraconverterthathasLPTisdisabled.TheDiagnosticstateis
helpfulduringfirstpowerup,beforealllinksofacircuitareconnected,asitallowstheinstallertoseeeachlink
turnonasthecablesarepluggedin.It’salsohelpfulforfindingthelocationofafault,ifoneexists.
ThemediaconverterremainsintheDiagnosticstateuntilthefollowingconditionismet:
Thelinkstatusforbothofthemediaconverter’sportsisup,simultaneously.
Afterthatconditionismet,ALPTenterstheActivestate.ItremainsintheActivestateuntiltheconverteriseither
powereddown,oreitherthecopperportorthefiberportlosesLink.IntheActivestate,ActiveLPTworksas
shownbelow(thesameaswhenregularLPTisenabled).

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttps://www.transition.comPage8of13
Far‐EndFault
Far‐EndFaultisavaluablefeatureusedinamediaconverterwhenitlosesReceiveFiberlink,butstillhasavalid
FiberTransmitlink.
Whenafaultoccursonanincomingfiberlink(1),themediaconvertertransmitsaFar‐EndFaultsignalonthe
outgoingfiberlink(2).Inaddition,theFar‐EndFaultsignalalsoactivatestheLinkPass‐Through,whichinturn
disablesthelinkonthecopperportionofthenetwork(3)and(4).
Specifications
ThefiberopticcablephysicalcharacteristicsmustmeetorexceedIEEE802.3aespecification.
CableSpecifications
ThephysicalcharacteristicsmustmeetorexceedIEEE802.3™specifications.
Copper Cable
Category 5: (minimum requirement)
Gauge: 24 to 22 AWG
Attenuation: 22.0 db /100m @ 100 MHz
Maximum Cable Distance: 100 meters
Straight-through or crossover cable may be used.
Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used
Pins 1&2 and 3&6 are the two active pairs in an Ethernet network
RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange,
etc.)
Do not use flat or silver satin wire.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttp://www.transition.com/Page9of13
Fiber Cable
BitErrorRate:<10‐9
Singlemodefiber(recommended): 9μm
Multimodefiber(recommended): 62.5/125μm
Multimodefiber(optional): 100/140,85/140,50/125μm
E‐100BTX‐FX‐06 1300nmmultimode
FiberOpticTransmitterPower: min:‐19.0dBm max:‐14.0dBm
FiberOpticReceiverSensitivity: min:‐30.0dBm max:‐14.0dBm
LinkBudget:11.0dbm
E‐100BTX‐FX‐06(SC)&(LC) 1300nmmultimode
FiberOpticTransmitterPower: min:‐19.0dBm max:‐14.0dBm
FiberOpticReceiverSensitivity: min:‐30.0dBm max:‐14.0dBm
LinkBudget:11.0dbm
E‐100BTX‐FX‐06(SM) 1310nmsinglemode
Fiber‐opticTransmitterPower: min:‐15.0dBm max:‐8.0dBm
Fiber‐opticReceiverSensitivity: min:‐31.0dBm max:‐8.0dBm
LinkBudget:16.0dbm
E‐100BTX‐FX‐06(SMLC) 1310nmsinglemode
Fiber‐opticTransmitterPower: min:‐15.2dBm max:‐8.0dBm
Fiber‐opticReceiverSensitivity: min:‐32.5dBm max:‐3.0dBm
LinkBudget:17.3dbm
ThefiberoptictransmittersonthisdevicemeetClassILasersafetyrequirementsperIEC‐825/CDRHstandards
andcomplywith21CFR1040.10and21CFR1040.11.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttps://www.transition.comPage10of13
TechnicalSpecifications
StandardsIEEE802.3
DataRate100Mb/s
DIPSwitch
SW1:Auto‐NegotiationOn/Off
SW2:PauseTXOn/Off
SW3:LPTOn/Off
SW4:FEFOn/Off
StatusLEDs
PWR(Power):Litfornormaloperation
SDF(SignalDetectFiber):Litforfiberlink
SDC(SignalDetectCopper):Litforcopperlink
RXF(ReceiveFiber):Flashing=RXdata
RXC(ReceiveCopper):Flashing=RXdata
DimensionsWidth:3"[76mm]xDepth:4.7”[119mm]xHeight:1"[25mm]
PowerSupplyExternalAC/DCrequired;Output:12VDC.0.41Amps;
input120‐240VAC,unregulated;standard
PowerConsumption1.75Watts(Fixedopticsmodels)
1WattplustheSFP(SFPmodels)
Environment
Tmra*(Standardtemp):0°Cto50°C(32to122°F)
StorageTemperature: ‐15°Cto65°C(5to149°F)
Humidity:5%to95%(non‐condensing)
Altitude:0–10,000ft.
Weight6oz.(181g)approximately
Compliance
Safety:WallMountPowerSupply:ULListed,cULListed(Canada).
FCCPart15ClassA,EN55032:2012,EN55024:2010
Directive2014/30/EU
Low‐VoltageDirective2014/35/EU
IEC/EN60950‐1:2006+A2:2013
2011/65/EUEN50581:2012
CEMark
MTBFGreaterthan46,768hours(MIL‐HDBK‐217F)
Greaterthan123,861hours(Bellcore7V5.0)
WarrantyLifetime
*Manufacturer’sratedambienttemperature.
CAUTION:Visibleandinvisiblelaserradiationwhenopen.Donotstareintobeamorviewdirectlywithoptical
instruments.
CAUTION:Useofcontrols,adjustmentsortheperformanceofproceduresotherthanthosespecifiedhereinmay
resultinhazardousradiationexposure.
CAUTION:Copperbasedmediaports,e.g.,TwistedPair(TP)Ethernet,USB,RS232,RS422,RS485,DS1,DS3,Video
Coax,etc.,areintendedtobeconnectedtointrabuilding(insideplant)linksegmentsthatarenotsubjectto
lighteningtransientsorpowerfaults.Copperbasedmediaports,e.g.,TwistedPair(TP)Ethernet,USB,RS232,
RS422,RS485,DS1,DS3,VideoCoax,etc.,areNOTtobeconnectedtointer‐building(outsideplant)linksegments
thataresubjecttolighteningtransientsorpowerfaults.Failuretoobservethiscautioncouldresultindamageto
equipment.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttp://www.transition.com/Page11of13
Troubleshooting
Ifthemediaconverterfails,isolateandcorrectthefaultbyansweringthefollowingquestionsandthentakingthe
indicatedaction.Note:DIPswitchpositions3and4mustbeDOWNbeforestartingthetroubleshootingprocess.
1.IsthePowerLEDlit?
NO
•Isthepoweradapterthecorrectmodel(checkI/OvoltageandHz)?
•VerifythevoltageandfrequencyoftheACoutlet.
•Arethepowerbarrelconnectorandwallplugofthepoweradapterproperlyinsertedinthemediaconverter
andpluggedintoaliveACwalloutlet?
•ContactTechSupport.SeeContactUsonpage18below.
YES:Proceedtostep2.
2.IstheSDC(signaldetect/copper)LEDlit?
NO
•Checkthetwisted‐paircablesforproperconnection.
•ContactTechSupport.SeeContactUsonpage18below.
YES:Proceedtostep3.
3.IstheSDFLED(signaldetect/fiber)illuminated?
NO
•Checkthefibercablesforproperconnection.
•VerifythattheTXandRXcablesonthemediaconverterareconnectedtotheRXandTXports,respectively,on
theotherdevice.
•ContactTechSupport.SeeContactUsonpage18below.
YES:Proceedtostep4.
4.IstheRXC(receive/copper)LEDflashing?
NO
•IfthereisnoactivityontheUTP/STPport,proceedtostep5.
•IfthereisactivityontheUTP/STPport,disconnectandreconnectthetwisted‐paircabletorestartthe
initializationprocess.
•ContactTechSupport.SeeContactUsonpage18below.
YES:Proceedtostep5.
5.IstheRXF(receive/fiber)LEDflashing?
NO
•Ifthereisnoactivityonthefiberport,contactTechSupport.
•Ifthereisactivityonthefiberport,disconnect/reconnectthefibercabletorestartinitializationprocess.
•ContactTechSupport.SeeContactUsonpage18below.
YES:ContactTechSupport.SeeContactUsonpage18below.

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttps://www.transition.comPage12of13
Contact Us
TechnicalSupport:Technicalsupportisavailable24‐hoursaday
USandCanada:1‐800‐260‐1312
International:00‐1‐952‐941‐7600
MainOffice
tel:+1.952.941.7600|tollfree:1.800.526.9267|fax:952.941.2322
Address
TransitionNetworks
10900RedCircleDrive
Minnetonka,MN55343,U.S.A.
Web:https://www.transition.com
Compliance Information
DeclarationofConformity

TransitionNetworksE‐100BTX‐FX‐06UserGuide
33791Rev.Ahttp://www.transition.com/Page13of13
FCC regulations
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttoPart
15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhen
theequipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,usesandcanradiateradio
frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,maycauseharmful
interferencetoradiocommunications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterference,inwhichcasetheuserwill
berequiredtocorrecttheinterferenceattheuser'sownexpense.
Canadian regulations
ThisdigitalapparatusdoesnotexceedtheClassAlimitsforradionoisefordigitalapparatussetoutontheradio
interferenceregulationsoftheCanadianDepartmentofCommunications.
Leprésentappareilnumériquen'émetpasdebruitsradioélectriquesdépassantleslimitesapplicablesaux
appareilsnumériquesdelaClassAprescritesdansleRèglementsurlebrouillageradioélectriqueédictéparle
ministèredesCommunicationsduCanada.
European regulations
Warning:ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhich
casetheusermayberequiredtotakeadequatemeasures.
Achtung!:DiesesisteinGerätderFunkstörgrenzwertklasseA.InWohnbereichenkönnenbeiBetriebdieses
GerätesRundfunkstörungenauftreten.IndiesemFällisderBenutzerfürGegenmaßnahmenverantwortlich.
Attention!:CeciestunproduitdeClasseA.Dansunenvironmentdomestique,ceproduitrisquedecréerdes
interférencesradioélectriques,ilappartiendraalorsàl'utilsateurdeprendelesmeasuresspécifiquesappropriées.
InaccordancewithEuropeanUnionDirective2002/96/ECoftheEuropeanParliamentandoftheCouncil
of27January2003,TransitionNetworkswillacceptpostusagereturnsofthisproductforproper
disposal.Thecontactinformationforthisactivitycanbefoundinthe'ContactUs'portionofthis
document.
CAUTION:RJconnectorsareNOTINTENDEDFORCONNECTIONTOTHEPUBLICTELEPHONENETWORK.
Failuretoobservethiscautioncouldresultindamagetothepublictelephonenetwork.
DerAnschlussdiesesGerätesaneinöffentlickesTelekommunikationsnetzindenEGMitgliedstaatenverstösst
gegendiejeweligeneinzelstaatlichenGesetzezurAnwendungderRichtlinie91/263/EWGzurAngleichungder
RechtsvorschriftenderMitgliedstaatenüberTelekommunikationsendeinrichtungeneinschliesslichder
gegenseitigenAnerkennungihrerKonformität.
Record of Revisions
RevDateNote
A7/25/19Initialrelease.
Trademarknotice:Alltrademarksandregisteredtrademarksarethepropertyoftheirrespectiveowners.
Copyrightrestrictions:©2019TransitionNetworks.Allrightsreserved.Nopartofthisworkmaybereproducedorusedin
anyformorbyanymeans‐graphic,electronicormechanical‐withoutwrittenpermissionfromTransitionNetworks.
Table of contents
Other Transition Media Converter manuals
Popular Media Converter manuals by other brands

Louroe Electronics
Louroe Electronics AOP-SP70 Installation and operating instructions

Comnet
Comnet CNGE2MCPOEM Installation and operation manual

NEC
NEC TheaterSync Video Processor user manual

Shuncom
Shuncom SZ0XMAN user manual

Linear Technology
Linear Technology DEMO CIRCUIT 1672A quick start guide

ATEN
ATEN Console Converter CV-160 user manual