Transition S8TB User manual

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 2 of 11
Safety Warnings and Cautions
These products are not intended for use in life support products where failure of a product could reasonably be
expected to result in death or personal injury. Anyone using this product in such an application without express
written consent of an officer of Transition Networks does so at their own risk and agrees to fully indemnify
Transition Networks for any damages that may result from such use or sale.
Attention: this product, like all electronic products, uses semiconductors that can be damaged by ESD (electrostatic
discharge). Always observe appropriate precautions when handling.
NOTE: Emphasizes important information or calls your attention to related features or instructions.
WARNING:
Alerts you to a potential hazard that could cause personal injury.
CAUTION:
Alerts you to a potential hazard that could cause loss of data, or damage the system or equipment.
S8TB 8-Port Unmanaged Gigabit Ethernet Switch User Guide, PN 33672 Rev. B
Record of Revisions
Rev.
Date
Description
A
12/14/15
Initial release.
B
4/1/20
Update to Rev. B; add S8TB photo, DoC, and port layout; update MAC Table and
Memory Buffer capacity specs.
Trademark notice: All trademarks and registered trademarks are the property of their respective owners. All other
products or service names used in this publication are for identification purposes only and may be trademarks or
registered trademarks of their respective companies. All other trademarks or registered trademarks mentioned
herein are the property of their respective holders.
Copyright restrictions: © 2018-2020 Transition Networks, Inc. All rights reserved. No part of this work may be
reproduced or used in any form or by any means (graphic, electronic, or mechanical) without written permission
from Transition Networks.
Address comments on this product or manual to:
Transition Networks Inc.
10900 Red Circle Drive, Minnetonka, MN 55343
tel: +1.952.941.7600 | toll free: 1.800.526.9267 | fax: 952.941.2322
web: https://www.transition.com

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 3 of 11
Contents
Safety Warnings and Cautions................................................................................................................................2
Record of Revisions .................................................................................................................................................2
1. Introduction...........................................................................................................................................................4
Features ..................................................................................................................................................................4
Package Contents...................................................................................................................................................4
2. Hardware Description ..........................................................................................................................................5
LED Indicators.........................................................................................................................................................5
LED Indicator Descriptions..................................................................................................................................5
Power Cord Included...............................................................................................................................................5
Power On ................................................................................................................................................................5
3. Troubleshooting....................................................................................................................................................6
Incorrect Connections .............................................................................................................................................6
Diagnosing LED Indicators .....................................................................................................................................6
Labeling...................................................................................................................................................................6
4. Technical Specifications......................................................................................................................................7
5. Regulatory Compliance Information...................................................................................................................8
Regulatory Approvals..............................................................................................................................................8
Canadian EMI Notice ..........................................................................................................................................8
European Notice..................................................................................................................................................8
CE Mark ..................................................................................................................................................................8
FCC Regulations .................................................................................................................................................8
Canadian Regulations .........................................................................................................................................8
European Regulations.........................................................................................................................................9
Declaration of Conformity .......................................................................................................................................9
Contact Us ........................................................................................................................................................... 10

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 4 of 11
1. Introduction
This (8) 10/100/1000Base-T port switch with Auto-MDI/MDIX is an unmanaged multi-port switch that can be used
to build high-performance switched networks. This switch is a store-and-forward device that offers low latency for
high speed networking. It is designed for the core of the network backbone computing environment to solve traffic
block problems at SME (small, medium enterprise) businesses.
Features
•Conforms to IEEE 802.3, 802.3u. 802.3ab, 802.3az, and 802.3x
•8 10/100/1000 Base-T RJ-45 Ethernet ports
•Auto-MDIX on all ports
•N-Way Auto-Negotiation supported
•Store-and-Forward switching architecture
•Backplane Bandwidth 16 Gbps
•Embedded 192k bytes memory buffer
•4K MAC address table
•Up to 9K byte Jumbo Frame
•Small Form Factor
•Internal Power Supply
•Supports full and half-duplex for 10/100Mbps and full-duplex for 1000Mbps
•Wire-speed packet filtering and forwarding rate
•Supports IEEE 802.3az energy efficient Ethernet
Package Contents
Unpack the contents of the S8TB packaging and verify the checklist below.
•One S8TB Switch
•One Documentation Post card
•Four Rubber Feet
•Four Sponges
•One Wall Mount Kit (two brackets + 8 screws)
Compare the contents of your S8TB package with the standard checklist
above. If any item is missing or damaged, please contact your local dealer
for service. Save the packaging materials for possible future use.

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 5 of 11
2. Hardware Description
LED Indicators
The LED give real-time information of system operation status as shown and described below.
Front Panel
LED Indicator Descriptions
LED
Status
Description
PWR
Steady Green
Power is On
LINKK/ACT
Steady Green
Port connection on 1000Mbps
Steady Amber
Port connection on 10/100Mbps
Off
Port disconnect
Back Panel
Power Cord Included
To order the corresponding country specific power cord, add the extension from the list below to the end of the
SKU: - -NA = North America, -LA = Latin America, -EU = Europe, -UK = United Kingdom, -SA = South Africa,
-JP = Japan, -OZ = Australia, -BR = Brazil.
Power On
Connect the power cord to the power socket on the back panel of the switch. Connect the other side of power
cord to the power outlet. The power rating of the switch is AC voltage ranging from 100-240VAC, frequency
50~60Hz.

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 6 of 11
3. Troubleshooting
This section is intended to help you solve the most common problems on the S8TB switch.
Incorrect Connections
Faulty or loose cables
Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug.
If that does not correct the problem, try a different cable.
Non-standard cables
Non-standard and mis-wired cables may cause numerous network collisions and other network problem, and can
seriously impair network performance. A category 5-cable tester is a recommended tool for every 100Base-TX
network installation.
RJ-45 ports: Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω
Category 3, 4 or 5 cable for 10Mbps connections or 100Ω Category 5 cable for 100Mbps connections.
Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
Improper Network Topologies
It is important to make sure that you have a valid network topology. Common topology faults include excessive
cable length and too many repeaters (hubs) between end nodes. In addition, you should make sure that your
network topology contains no data path loops. Between any two end nodes, there should be only one active
cabling path at any time. Data path loops will cause broadcast storms that will severely impact your network
performance.
Diagnosing LED Indicators
The switch can be easily monitored through panel indicators, which describe common problems you may
encounter, to assist in identifying problems and where you can find possible solutions. See the section “LED
Indicators” on page 5 above.
Labeling
After performing the troubleshooting steps above, and before contacting Tech Support, check the product and
packaging labels for information to provide Tech Support.
Product Label Box Label Carton Label

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 7 of 11
4. Technical Specifications
The table below lists the S8TB switch specifications.
Standards
IEEE 802.3 10BASE-T Ethernet
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000Base-T Gigabit Ethernet
IEEE802.3x Duplex Flow Control
IEEE802.3az EEE
Protocol
CSMA/CD
Technology
Store and Forward switching architecture
Cable Connections
RJ-45 (10BASE-T): Category 3,4,5 UTP/STP
RJ-45 (100BASE-TX): Category 5 UTP/STP
RJ-45 (1000BASE-T): Category 5,5e or enhanced UTP/STP
Connectors
(8) 10/100/1000 RJ-45 ports
Network Rate
10/100/1000 Mbps Auto-negotiation
Jumbo Frames
9K Bytes
MAC Address Table
8K-entry (Rev. A)
4K-entry (Rev. B)
Memory Buffer
128K bytes (Rev. A)
192K bytes (Rev. B
Status LEDs
(8) port LEDs speed (Green: 1000Mbps, Amber 10/100 Mbps), Link/Activity
(flashing)
Backplane
16Gbps
Case
Metal
Operating Temp.
0 deg. C to +40 deg. C (+32 deg. F to +104 deg. F)
Operating Humidity
10% to 90% (Non-condensing)
Storage Temp.
-40 deg. C to +70 deg. C (-40 deg. F to +158 deg. F)
Power Input
Internal Power: 100 - 240VAC, 50~60Hz
Power Consumption
3.5 Watts max.
Dimensions
Width: 6.3” [160 mm] x Depth: 3.94” [100 mm] x Height: 1.28” [32.5 mm]
Weight
1.35 lbs. [0.61 kg]
Warranty
Limited Lifetime Warranty

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 8 of 11
5. Regulatory Compliance Information
Regulatory Approvals
Compliance
Safety: LVD
Emissions: FCC Class B, CE Mark,
UL Listed, CCC
EN55022 Class B
Canadian EMI Notice
This Class B digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du
Canada.
European Notice
Products with the CE Marking comply with both the EMC Directive (2004/108/EC) and the Low Voltage Directive
(2006/95/EC) issued by the Commission of the European Community Compliance with these directives imply
conformity to the following European Norms:
EN55022 (CISPR 22) - Radio Frequency Interference
EN60950 (IEC950) - Product Safety
CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out on the radio
interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils
numériques de la Class B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des
Communications du Canada.

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 9 of 11
European Regulations
Warning
This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe B. Dans un environment domestique, ce produit risque de créer des interférences
radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of
27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The
contact information for this activity can be found in the 'Contact Us' portion of this document.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe
this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EGMitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der
Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen
Anerkennung ihrer Konformität.
Declaration of Conformity

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 10 of 11
Contact Us
Technical Support: Technical support is available 24-hours a day
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Main Office
tel: +1.952.941.7600 | toll free: 1.800.526.9267 | fax: 952.941.2322
Address
Transition Networks
10900 Red Circle Drive
Minnetonka, MN 55343, U.S.A.
Web: https://www.transition.com

Transition Networks S8TB User Guide
33672 Rev. B https://www.transition.com/ Page 11 of 11
Transition Networks
10900 Red Circle Drive
Minnetonka, MN 55344
tel: +1.952.941.7600 | toll free: 1.800.526.9267 | fax: 952.941.2322
© Copyright 2015-2020 Transition Networks. All rights reserved.
8-Port Unmanaged Gigabit Ethernet Switch User Guide, PN 33672 Rev. B
Table of contents