manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TREND
  6. •
  7. Repeater
  8. •
  9. TREND ACCW/RW/IQ User manual

TREND ACCW/RW/IQ User manual

Popular Repeater manuals by other brands

Kenwood TKR-750-850 Function reference

Kenwood

Kenwood TKR-750-850 Function reference

Asus RP-AC51 quick start guide

Asus

Asus RP-AC51 quick start guide

Exibel HRP0101 instruction manual

Exibel

Exibel HRP0101 instruction manual

Kenwood TKR-750 Service manual

Kenwood

Kenwood TKR-750 Service manual

York Universal LINC485 installation manual

York

York Universal LINC485 installation manual

MIKOM MRx01B Power Series user manual

MIKOM

MIKOM MRx01B Power Series user manual

Simrad RD 301 instruction manual

Simrad

Simrad RD 301 instruction manual

Inventronics DALI REPEATER SO operating instructions

Inventronics

Inventronics DALI REPEATER SO operating instructions

XFP 16 installation manual

XFP

XFP 16 installation manual

Andrew MRx18 user manual

Andrew

Andrew MRx18 user manual

COMBA RXA3748 user manual

COMBA

COMBA RXA3748 user manual

ADRF SDR-ICS-43 user manual

ADRF

ADRF SDR-ICS-43 user manual

Teltonika WRP100 user manual

Teltonika

Teltonika WRP100 user manual

U-Prox HW installation manual

U-Prox

U-Prox HW installation manual

Motorola VRS750 Service manual

Motorola

Motorola VRS750 Service manual

KanexPro SDI-HDRPTPRO user manual

KanexPro

KanexPro SDI-HDRPTPRO user manual

Ltech LT-3030-CС quick start guide

Ltech

Ltech LT-3030-CС quick start guide

Gigaset 108 owner's manual

Gigaset

Gigaset 108 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ACCW/RW/IQ Wireless Sensors Repeater Installation Instructions TG200852 Issue 1/A 20/06/05 1
Installation Instructions
ACCW/RW/IQ
Wireless Sensors Repeater
Important: Retain these instructions
INSTALLATION
UNPACKING
ACCW/RW/IQ
Installation Instructions
TG200852
Dimensions
1
6 mm
180 mm
158 mm
60 mm
13 A plug
(supplied)
2 m
antenna
2 holes
Ø 9 mm
80 mm
Requirements
2
a
-20 °C +55 °C Protection IP675
ambient limits indoor use only
non-condensing
b
75 m maximum 75 m maximum
e.g. TW/P (TB/TO)
wireless sensor ACCW/RW/IQ
wireless repeater
XW/R/IQ
wireless receiver
Note that range may be affected by
environmental characteristics, e.g. partitions,
walls, building structure etc.
315 mm
190 mm
ACCW/RW/IQ InstallationInstructions
ACCW/RW/IQ Wireless Sensors Repeater Installation Instructions TG200852 Issue 1/A 20/06/052
INSTALLATION (continued)
Requirements (continued)
2
c
• The only certain way of determining performance in a specific location is to conduct a range
test and RF spectrum scan for other potential users.
• Both the path survey and spectrum scan are normally conducted prior to installing. However,
as by its nature the 434 MHz AMR system is intended for short-range applications, in practice
interference is extremely rare, and the FR capture effect prevails, (nearest signal wins). This,
in most cases, obviates the need for a spectrum survey, leaving only the path survey.
• If a confidence scan is required, both the desired and adjacent channels should be checked
for signals. As transmissions may be intermittent it is important to take time with the scan,
stopping for as long as possible on each channel and looking for at least 15 minutes on the
final chosen band.
• In white walled buildings (rooms thermally insulated with foam and aluminium; food industry)
best performance may be found by mounting the repeater in the loft space above the white
walled area. There will always be a degree of leakage in a white wall building, and once out
of a room, propagation is much easier in a loft space compared to between white walled rooms.
Mount unit
3
Ensure antenna is vertical
!
158 mm
2 holes Ø 9 mm
Connect Power
4
230 Vac 50 Hz 1 W maximum
Either use 13 A UK style fused plug provided
or wire to a fused spur (fuse: 1 A 250 V HRC
20mm)
ACCW/RW/IQ Wireless Sensors Repeater Installation Instructions TG200852 Issue 1/A 20/06/05 3
InstallationInstructions ACCW/RW/IQ
INSTALLATION(continued)
Install Sensor and Receiver
5
TW/S Installation Instructions TG200781
TW/P Installation Instructions TG200782
PCW/.. Installation Instructions TG200784
XW/R/IQ Installation Instructions TG200783
Switch On
6
0
I
Test System
7
IQ
ΔT
e.g. TB/TI/..
XW/R/IQ
1 min.
ACCW/RW/IQ
ACCW/RW/IQ InstallationInstructions
ACCW/RW/IQ Wireless Sensors Repeater Installation Instructions TG200852 Issue 1/A 20/06/05
4
Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof
without obligation to notify any person of such revisions or changes.
Trend Control Systems Limited
P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK. Tel:+44 (0)1403 21888 Fax:+44 (0)1403 241608 www.trend-controls.com
DISPOSAL
WEEE Directive :
Attheendoftheiruseful life thepackaging,
product,and batteries should bedisposed
of via a suitable recycling centre.
Do not dispose of with normal household waste.
Do not burn.