Prestige
Venturi Replacement
1
WARNING
!
Indicates a potentially hazardous situation which,
if ignored, can result in serious injury or substan-
tial property damage.
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
WARNING
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
• Instructions are for a qualified installer/ ser-
vice technician only.
• Read all instructions before proceeding.
• Follow instructions in proper order.
Each Kit Includes:
• Venturi
• Venturi/Blower Gasket
• Venturi Screws
Recommended Tools:
• Adjustable Wrench
• Torx Screwdriver
• Phillips Head Screwdriver
Kit Part Number Description Model
PSRKIT83 Venturi Replacement Prestige 250
TCRKIT19 Venturi Replacement Prestige 299/399
2020-19 Prestige CTRLMax Venturi Replacement
Revised 1/10/2020
Prestige
Venturi Replacement
2
1. Preliminary Instructions:
1. Verify that the Venturi replacement kit is correct for
the model of boiler. See table on page 1.
2. Carefully open and unpack the PARTS BOX from its
shipping carton.
3. Carefully remove and check for any damage.
NOTICE
Do not proceed with installation and contact Triangle Tube
right away if the venturi is damaged in any way.
4. Turn o the electrical power supply to the boiler.
5. Close the manual gas shut o valve to the unit.
2. Venturi Removal Instructions:
1. Remove the front jacket panel.
2. Remove the screws securing the gas valve/gas pip-
ing from the Venturi. Do NOT discard the gas Ori-
ce (if present).
3. Remove the screws securing the venturi to the
blower. Discard the venturi/blower gasket. Do NOT
discard the venturi screws.
4. Remove the old Venturi from the unit.
Fig. 3: Prestige 250
Fig. 4: Prestige 299-399
3. Venturi Installation Instructions:
1. Secure the new venturi with a new gasket to the
blower using the previously removed screws.
2. Install the orice (if present) and orice gasket be-
tween the gas valve and venturi as per Fig. 3 and
Fig. 4. Tighten the screws securing the gas valve to
the venturi.
3. Tighten the screws to secure the venturi 31-35 in-
lbs of torque.
WARNING
!
Ensure the orifice is installed with the gasket as pre-
viously installed. Installing the orifice incorrectly can
result improper combustion and can result in substan-
tial property damage, serious injury, or death.
NOTICE
For the reassembly process do not use adhesive on any gas-
ket surface.
Prestige
Venturi Replacement
3
WARNING
!
Ensure the o-ring/gasket are in place before reassem-
bly. Failure to do so can result in death, serious injury
or substantial property damage.
WARNING
!
Ensure the venturi is properly sealed in order to pre-
vent a gas leak. Gas leaks can result in death, serious
injury or substantial property damage.
4. Open the main shuto valve to the gas supply
piping. Before placing the boiler back into service
check and test all gas piping connections for leaks.
Repair leaks if found.
WARNING
!
Do not check for gas leaks with an open flame. Use a
bubble test. Failure to check for gas leaks can cause
severe personal injury, death or substantial property
damage Combustion Test and Adjustments
4. Combustion Test and Adjustments
NOTICE
The installer MUST perform a complete combustion check
to ensure the following combustion levels are met at high
and low input ring rates and the burner is operating at op-
timum conditions.
Table 1: Recommended Combustion Settings
Nat. Gas
All Modes
Propane
250/299
Propane
399
High Fire
CO2Range 8.8 to
10.5%
10.7 to
12.0%
10.4 to
11.4%
CO2Target 9.2% 11.0%
O2Range 2.3 to
5.3%
2.7 to
4.7%
3.7 to
5.2%
O2Target 4.6% 4.2%
CO Max 100 ppm 150 ppm
Low Fire
CO2Range 0.5 to 0.6% Lower than or equal to
High Fire CO2level
O2Range 0.8 to 0.9% Higher than or equal to
High Fire CO2level
WARNING
!
The combustion testing and adjustments must be per-
formed by a qualified installer, service agency or the
gas supplier. All combustion measurements must be
performed with calibrated equipment to ensure prop-
er readings and accuracy.
WARNING
!
Failure to perform a complete combustion test at both
high and low input rates may result in incomplete
combustion and the production of carbon monoxide,
which can cause severe personal injury, death or sub-
stantial property damage.
Prestige
Venturi Replacement
4
1. Press the round INSTALLER button.
DHW Demand
Target = 186°F
Installer Button
Fig. 5: Navigation Buttons
2. Enter the installer access code “054” by using the
LEFT and RIGHT buttons to select a digit and the UP
and DOWN buttons to change the digit. Press the
OK button to enter the access code.
3. Press the RIGHT button to highlight the Manual
Operation icon then press the OK button.
4. Press the OK button while the FAN icon is high-
lighted to manually re the burner and power the
CH1 circulator (see Fig. 6)
Manual Operation
Released
O
O
O
CH1
FAN
DHW
CH2
Manual Operation
Released
O
O
O
CH1
FAN
DHW
CH2
Manual Operation
Released
O
O
O
CH2
FAN
DHW
CH1
Manual Operation
Released
O
O
O
DHW
FAN
CH1
CH2
Fig. 6: Manual Operation
NOTICE
An adequate CH load must be present to dissipate the heat
generated during the combustion test. If an adequate CH
load is not available an indirect water heater can be used to
dissipate the heat by creating a DHW call which will enable
the DHW circulator.
5. Press the RIGHT button to adjust the ring rate to
100% (high re). Hold down the RIGHT button to
rapidly increase the ring rate.
6. If the combustion levels during high re are outside
the recommended combustion settings adjust the
THROTTLE SCREW using a at-blade screwdriver as
follows:
Counter-clockwise adjustment of the THROTTLE SCREW
at High Fire (100% ring rate):
O2 decreases and CO2 increases
Clockwise adjustment of the THROTTLE SCREW at High
Fire (100% ring rate):
O2 increases and CO2 decreases
7. Once the combustion level is set at high re, manu-
ally place the boiler into low re mode by pressing
the LEFT button to adjust ring rate down to 1%
(low re) to verify low re combustion settings.
8. If the combustion levels (O2& CO2) during low re
are outside the recommended combustion set-
tings in Tables 2, contact Triangle Tube Technical
Support Department for assistance.
9. Press the OK button while the fan icon is highlight-
ed to shutdown the burner.
10. 11. Press the LEFT or RIGHT button to highlight the
home screen icon to exit the service mode.
11. Replace the front jacket panel and secure with
screws.
12. Turn on the electrical power supply to the Prestige
boiler and return the unit back to service.

This manual suits for next models

1

Other TriangleTube Gas Heater manuals

TriangleTube Delta Manual

TriangleTube

TriangleTube Delta Manual

TriangleTube CHALLENGER CC 85 User manual

TriangleTube

TriangleTube CHALLENGER CC 85 User manual

TriangleTube INSRKIT08 User manual

TriangleTube

TriangleTube INSRKIT08 User manual

TriangleTube INSRKIT58 User manual

TriangleTube

TriangleTube INSRKIT58 User manual

TriangleTube PTRKIT111 Use and care manual

TriangleTube

TriangleTube PTRKIT111 Use and care manual

Popular Gas Heater manuals by other brands

Desa Firewerks MPF24VNA OWNER'S OPERATION AND INSTALLATION MANUAL

Desa

Desa Firewerks MPF24VNA OWNER'S OPERATION AND INSTALLATION MANUAL

Sealey LP170.V3 manual

Sealey

Sealey LP170.V3 manual

Unitary products group PV8*UH installation manual

Unitary products group

Unitary products group PV8*UH installation manual

Desa LSFG20NT Safety information and installation manual

Desa

Desa LSFG20NT Safety information and installation manual

FMI Vantage Hearth VS1824NM OWNER'S OPERATION AND INSTALLATION MANUAL

FMI

FMI Vantage Hearth VS1824NM OWNER'S OPERATION AND INSTALLATION MANUAL

Lochinvar LVN(L) 065 Replacement parts list

Lochinvar

Lochinvar LVN(L) 065 Replacement parts list

Burley ENVIRON Installation, servicing  & user instructions

Burley

Burley ENVIRON Installation, servicing & user instructions

Dyna-Glo RMC-FA150NGDGD Operating instructions & parts manual

Dyna-Glo

Dyna-Glo RMC-FA150NGDGD Operating instructions & parts manual

Jøtul Allagash GF 300 DV Installation and operation instructions

Jøtul

Jøtul Allagash GF 300 DV Installation and operation instructions

Dyna-Glo GUH50NE/LE Operating instructions and owner's manual

Dyna-Glo

Dyna-Glo GUH50NE/LE Operating instructions and owner's manual

Design Dynamics VF-18N-PJD Owner's operating & installation manual

Design Dynamics

Design Dynamics VF-18N-PJD Owner's operating & installation manual

Flavel FRGCN0EN Installation and maintenance instructions

Flavel

Flavel FRGCN0EN Installation and maintenance instructions

Baxi 14Fi AM Blue User and installation instructions

Baxi

Baxi 14Fi AM Blue User and installation instructions

Goodman PG1660 user manual

Goodman

Goodman PG1660 user manual

Rasmussen CHILLBUSTER Evening Embers 7 Series manual

Rasmussen

Rasmussen CHILLBUSTER Evening Embers 7 Series manual

Heat & Glo LifeStyle ST-38HV-AU Installation and operation instructions

Heat & Glo LifeStyle

Heat & Glo LifeStyle ST-38HV-AU Installation and operation instructions

EmberGlow TCVFM18NL manual

EmberGlow

EmberGlow TCVFM18NL manual

Rheem Raypak R207A Installation and operation manual

Rheem

Rheem Raypak R207A Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.