Triner Scale TS-700 Series User manual

0
OG Version 2.0_03-15-17
Compatible with DataLogTM Scale-to-PC Data Logging Software
TS 700-SS
Series 3
TS 700-MS
Series 2
TS 700-WB
TS-700 Series Digital Indicators
Includes Appendix for Scale Technicians
Set Up • Calibration • Connectivity
Operating Guide

Triner Scale & Mfg.Co., Inc.
8411 Hacks Cross Road
Olive Branch, MS 38654
(800) 238-0152
www.trinerscale.com
© 2016-2020 Triner Scale. All rights reserved.
!!!! CALIBRATION WARNING !!!!
Calibration AND inspection of calibration properties
is prohibited unless done so by
a qualified scale technician.
WARNING
The indicator has static sensitive
components.
Do not make any connections without
powering off the indicator.
DANGER
Electric shock risk.
Take necessary precautions to avoid risk
of shock.

Operating Guide | TS-700 Series
1
Table of Contents
Specifications
TS-700 MS, SS and WB..................................................2
Quick Start: Connecting and Powering On
TS-700 MS........................................................................3
TS-700 SS ........................................................................5
TS-700 WB .......................................................................7
Operation
Keys and Functions: TS-700 MS, SS and WB...............9
Parameters and Settings
How to Access and Adjust Parameters ........................12
Example: How to Set Time & Date ...............................12
Parameters Charts .........................................................14
Compatible Receipt Printers
MP-20 Model & SP-500 Model Printers........................19
APPENDIX FOR SCALE TECHNICIANS
Calibration Procedure........................................................ A-1
Load Cell Connections
TS-700 MS & WB .................................................. A-9
TS-700 SS.............................................................. A-9
Serial Port/RS-232 Connections
TS-700 MS........................................................... A-10
TS-700 SS............................................................ A-11
TS-700 WB .......................................................... A-11
Data Output Formats, TS-700 MS, SS & WB
Remote Display Format ...................................... A-12
PC Computer Continuous Sending Format ....... A-13
Serial Interface Reception Command ................ A-13
Error Codes
TS-700 MS, SS and WB ..................................... A-15
Factory Default Parameter Settings
TS-700 MS, SS and WB ..................................... A-16

Operating Guide | TS-700 Series
2
Specifications
Resolution ......................... Display: 30,000
ADC................................... 2,000,000
Zero stability error .............. TK0 < 0.1µV//K
Span stability error ............. TKspn < ± 6 ppm//K
Sensitivity (internal)............ 0. 3 µV /d
Input voltage ...................... -30~30mV DC
Excitation circuit ................. 5 VDC
Load Cell Max.................... (8) 350Ω
AC power........................... AC100~250V
Operation temp .................. -10 °C ~ + 40 °C
Operation humidity............. ≤90% RH
Storage temp ..................... -40 °C ~ + 70 °C
KEYPAD KEYS
*requires adjustment of parameter settings
KEY
FUNCTION
On/Off
Powers on, powers of the indicator
Hold
Hold weight on scale, or Hold peak weight*,
or Hold unstable/animal weight*
Total
Total Weight: total of multiple weighings
Kg/lb
Display weight in pounds or kilograms
Gross/Tare
Tare container weight, display gross or net
weight
Zero
Returns the indicated weight to “0”
Print
Prints receipt (requires optional printer)
PC connectivity requires Triner Scale’s DataLog PC™
software.

Operating Guide | TS-700 Series
3
Quick Start: Connecting & Powering On
TS-700 MS
Connect Weighing Platform Cable
Attach the home run cable from the weighing
platform to the loadcell port located on the
underside of the digital indicator.
Connect Any Optional Devices
Referring to the manual provided with optional
device (such as a receipt printer), connect the

Operating Guide | TS-700 Series
4
Quick Start: Connecting & Powering On
TS-700 MS
device to the RS-232 port located on the underside
of the digital indicator. Power on the device.
Connect AC Adapter
Plug the AC adapter included with the digital
indicator into the 9VDC 1200ma port located on the
underside of the digital indicator.
Power On The Digital Indicator
Press and hold the ON/OFF key for 2+ seconds to
power on the indicator. A self-test routine will run,
followed by “0” indicated weight. If a small amount
of weight displays, press the Zero (word) key. Scale
is ready to operate.
IMPORTANT NOTE: if equipped with optional
built in rechargeable battery, fully charge for 18
hours before operating on battery power.
Operation
Refer to page 9 for operating instructions and
functions details.
Certain settings in the TS-700 MS can be adjusted
according to user preferences. Refer to page 14 for
a listing of adjustable parameters and available
settings options.

Operating Guide | TS-700 Series
5
Quick Start: Connecting & Powering On
TS-700 SS
Connect Weighing Platform Cable
Attach the home run cable from the loadcell port to
the weighing platform junction box. Refer to
installation instructions provided with the Triner
Scale weighing platform.

Operating Guide | TS-700 Series
6
Quick Start: Connecting & Powering On
TS-700 SS
Connect Any Optional Devices
Referring to the manual provided with optional
device (such as a receipt printer), connect the
device to the RS-232 port located on the underside
of the digital indicator. Power on the device.
Connect AC Adapter
Plug the AC adapter included with the digital
indicator into the 9VDC 1200ma port located on the
underside of the digital indicator.
Power On The Digital Indicator
Press and hold the ON/OFF key for 2+ seconds to
power on the indicator. A self-test routine will run,
followed by “0” indicated weight. If a small amount
of weight displays, press the ZERO (word) key.
Scale is ready to operate.
IMPORTANT NOTE: Fully charge for 18 hours
before powering the indicator from the built in
rechargeable battery.
Operation
Refer to page 9 for operating instructions and
functions details.
Certain settings in the TS-700 MS can be adjusted
according to user preferences. Refer to page 14 for
a listing of adjustable parameters and available
settings options.

Operating Guide | TS-700 Series
7
Quick Start: Connecting & Powering On
TS-700 WB
Connect the Weigh Bar Cables
Attach the home run cables to the loadcell ports and
to the weigh bars. For weigh bar set up, refer to the
User’s Guide included with livestock the scale.

Operating Guide | TS-700 Series
8
Quick Start: Connecting & Powering On
TS-700 WB
Connect Any Optional Devices
Referring to the manual provided with optional
device (such as a receipt printer), connect the
device to the RS-232 port located on the underside
of the digital indicator. Power on the device.
Connect AC Adapter
Plug the AC adapter included with the digital
indicator into the 9VDC 1200ma port located on the
underside of the digital indicator.
Power On The Digital Indicator
Press and hold the ON/OFF key for 2+ seconds to
power on the indicator. A self-test routine will run,
followed by “0” indicated weight. If a small amount
of weight displays, press the ZERO (word) key.
Scale is ready to operate.
IMPORTANT NOTE: Fully charge for 18 hours
before powering the indicator from the built in
rechargeable battery.
Operation
Refer to page 9 for operating instructions and
functions details.
Certain settings in the TS-700 MS can be adjusted
according to user preferences. Refer to page 14 for
a listing of adjustable parameters and available
settings options.

Operating Guide | TS-700 Series
9
Operation
KEYS AND FUNCTIONS:
TS-700 MS, SS & WB
KEY
FUNCTION/OPERATION
On/Off
Press and hold for 2+ seconds to operate.
Livestock Hold (animal weight hold):
If set up for livestock weighing, the animal’s weight
will automatically hold.
To Hold Weight on Scale (manual hold):
With weight on scale, press Hold key.
To Hold Peak Weight of Multiple Weighings (auto
hold)*:
To enable, press Hold key before loading scale.
To Release the Hold Function:
Press hold key again to return to normal operation.
*Requires adjustment of parameter #11
Hold
In Settings Mode: Return Key
- Previous
- Pressed with other key(s) for functions.

Operating Guide | TS-700 Series
10
KEY
FUNCTION/OPERATION
To Add Weights:
With weight on scale, press the Total key to
place weight and count in memory. Remove
weight, place next item on scale, press Total to
add weight to total weight and total count.
To View Accumulated Total:
Press Total and Print key at the same time. The
total weight will flash continuously.
To Print Accumulated Total:
Press and hold the Print key for 3 seconds while in
View Totals mode (requires optional printer).
To Go Out of View Accumulated Total Mode:
Press and hold the Total key. “Clr n” will
display.
If you wish to continue adding to the totals,
press the Print to accept the “Clear-No” prompt.
Continue weighing and adding items as
required.
To Clear the Totals Memory:
Press the Zero/Up Arrow key to change the
“Clr n” display to “Clr y”. Press the Print key to
accept the “Clear-Yes” prompt.
Total
In Settings Mode: Previous/Home Key
First press = previous
Second press = home
Press to change pounds/kilograms
kg/lb
In Settings Mode: Left Arrow Key
Press to move active digit one unit over to the
left
NOTE:
Before placing
the next weight
on scale to be
added to total,
make certain
that the indictor
has returned to
“0” weight, and
the scale is
stable.

Operating Guide | TS-700 Series
11
KEY
FUNCTION/OPERATION
For use after a TARE weight has been stored in
the indicator. Press key to toggle view between
gross and net weight.
PLEASE NOTE that there may be a momentary
pause in the display when going from gross to
tare weight.
Gross
In Settings Mode: Right Arrow Key
Press to move active digit one unit over to the
right
With weight on the scale, press to Tare the
weight.
Press again to remove Tare weight.
Tare
In Settings Mode: Down arrow key
Press to reduce value of active (flashing) digit.
Press key to zero the scale.
Zero
In Settings Mode: Up arrow key
Press to increase value of active (flashing) digit.
Print
Press key to print a ticket (requires optional
printer).
In Settings Mode: Enter Key
Press to accept entry.
Press to proceed to next item.
IF EQUIPPED WITH INTERNAL RECHARGEABLE
BATTERY: Fully charge the battery for 18 hours before
operating on battery power.

Operating Guide | TS-700 Series
12
Parameters and Settings
CAUTION: Use care when accessing and
adjusting your indicator’s parameters.
Several parameters can be accessed that, if
altered, will change your indicator’s
operations.
HOW TO ACCESS AND ADJUST THE
TS-700 MS PARAMETERS
Press and hold down the PRINT and HOLD keys.
“C” will display. Release the keys. “C08” or “C01”
will display*, with last digit flashing. The digit
flashing is the active digit, and can be adjusted up
or down by using the Zero/up arrow key or
Tare/down arrow key. Use the kg-lb/left arrow key
and the Gross/right arrow key to change which digit
is active (flashing).
*TIP: Parameters C01 through C07 are for
typically locked out and are only accessible
by scale technician during calibration.
Navigate to the setting parameter you wish to adjust
and use the arrow keys to change the settings values.
Press the Print/enter key to accept your settings, then
press the Total/home key to exit.
EXAMPLE: To adjust the date setting in
parameter C16:
With the 8 flashing in “C08”, press the
Tare/down arrow key to reduce the 8 to 6.

Operating Guide | TS-700 Series
13
Press the kg-lb/left arrow key to move the
active digit from the 6 to the 0 (the 0 will
flash).
Use the Zero/up arrow key to increase the 0
to 1 (C16 will display).
Press the Print/enter key.
The display will show digits for month, day
and year. Use the arrow keys as discussed
above to navigate to and change the digits.
Press the Print/enter key to accept your
settings.
Press the Total/home ( ) key to exit.

Operating Guide | TS-700 Series
14
PARAMETERS CHART
(For calibration parameters, see Appendix for Scale
Technicians, page A-4)
PARAMETER
FUNCTION
OPTIONS
C08
Warning tone
0 = Disable warning tone
1 = warning tone on
C09
Automatic
Power-off
0 = Disable auto off
10 = Power off in 10
minutes.
30 = Power off in 30
minutes.
60 = Power off in 60
minutes.
C10
Power saving
setting
(display
backlight on/off)
0 = Disable power saving
setting
3 = Display off in 3 min.
5 = Display off in 5 min.
C11
Hold function
0 = Disable hold function
1 = Hold peak weight
2 = Hold weight on scale
3 = Hold animal weight
4 = Reserved
Note: “hold peak weight”
will display the max. load
of multiple weighings.
C12
Kg/lb
conversion
0 = kg/lb conversion
disabled
1 = kg/lb conversion
enabled
C13
Upper/lower
limit alarm
C14
Lower limit
alarm value
Enter numeric values for
upper and lower
checkweighing limits.

Operating Guide | TS-700 Series
15
PARAMETER
FUNCTION
OPTIONS
C15
Inner Code
display
Enter C15 to check the
inner code.
C16
Date
Set the date, from left to
right: year/month/day
C17
Time
Set the time from left to
right: hour/min./sec.
C18
Communication
setting
(Serial interface
data output
method)
0 = Serial interface data
output disabled
1 = Continuous sending,
remote display
2 = Print key sends data to
printer or PC.
3 = PC command request
(DataLogPC software)
4 = PC continuous
sending.
5 = Remote display
continuous sending
format.
C19
Baud rate
0 = 1200 1 = 2400
2 = 4800 3 = 9600
C20
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Zero range
(amount that
can be zeroed
out with the
Zero key)
0 = Disable manual zero
setting
1 = ±1% max capacity
2 = ±2% max capacity
4 = ±4% max capacity
10 = ±10% max capacity
20 = ±20% max capacity
100 = ±100% max capacity
C21
Zero range at
power-up
0 = no initial zero setting
1 = ±1% max capacity
2 = ±2% max capacity
5 = ±5% max capacity
10 = ±10% max capacity
20 = ±20% max capacity

Operating Guide | TS-700 Series
16
PARAMETER
FUNCTION
OPTIONS
C22
CAUTION:
Changing
these
parameters will
effect the
indicator’s
performance.
Automatic Zero:
tracking range
0 = Disable zero
tracking
0.5 = ±0.5d
1.0 = ±1.0d
2.0 = ±2.0d
3.0 = ±3.0d
4.0 = ±4.0d
5.0 = ±5.0d
Note:
•d = division
•The zero tracking range
cannot be more than
manual zero range.
C23
Automatic
Zero; tracking
time
0 = Disable zero tracking
time
1 = 1 second
2 = 2 seconds
3 = 3 seconds
C24
CAUTION:
Changing
these
parameters will
effect the
indicator’s
performance.
Overload range
00 = close overload range
01d -- 99d
(d = division)
C25
Negative display
0 = -9d
10 = 10% max. capacity
20 = 20% max. capacity
50 = 50% max. capacity
100 = 100% max. capacity

Operating Guide | TS-700 Series
17
PARAMETER
FUNCTION
OPTIONS
C26
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Standstill time
0 = quick
1 = medium
2 = slow
C27
Standstill range
1 = 1d 2 = 2d
5 = 5d 10 = 10d
(d = division)
C28
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Digital filter
To compensate
for unstable
loads on the
weighing
platform (for
example, animal
weighing).
0 = close dynamic filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
4 = 4 digital filter strength
5 = 5 digital filter strength
6 = 6 digital filter strength
C29
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Noise filter
0 = disable noise filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
C30
Format of date
print out
0 = yy.mm.dd
1 = mm.dd.yyyy
2 = dd.mm.yyyy
3 = yyyy.mm.dd
C31
OPTIONAL
output setting
0 = 0~5Voutput
1 = 4~20mA output
C32
RESERVED
-------

Operating Guide | TS-700 Series
18
PARAMETER
FUNCTION
OPTIONS
C33
OPTIONAL
Relay output
setting
0 = Close relay output
1 = Open relay output
function 1
2 = Open relay output
function 2
3 = Reserved menu
C34
RESERVED
-------
C35
RESERVED
--------
C36
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Gravity of
calibration
location
(Only available
to technician
during
calibration)
C36 = 9.7000 -- 9.9999
C37
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Gravity of
destination
(Only available
to technician
during
calibration)
C37 = 9.7000 -- 9.9999
C38
Reserved
-------
TIP: When in parameter settings
mode, you can move forward through
all parameters and view the settings by
pressing the Print (
) key
repeatedly.
Other manuals for TS-700 Series
1
This manual suits for next models
3
Table of contents
Popular Touch Panel manuals by other brands

Extron electronics
Extron electronics TouchLink TLP 710CV user guide

Tyco Electronics
Tyco Electronics 1522L-XXWB Series user guide

IEI Technology
IEI Technology IAS0-W10B-N6210 user manual

DFI
DFI VS436 (15") Specifications

Blue Seal
Blue Seal turbofan 30T Series Installation and operation manual

Crestron
Crestron TST-602 Supplemental guide