Kendrion Vico MT 727 User manual

User Guide
Vico MT 727, Vico MT 1027, Vico MT 1527
Multi-touch Panel with CODESYS HMI
Web Terminal
E 863 GB 01/10/2021

Kendrion Kuhnke Automation GmbH Table of Contents
Vico MT (E 863 GB) 2
01/10/2021
Table of Contents
1 Preface ............................................................................................................................................................5
1.1 Legal Notice........................................................................................................................................5
Version Details...................................................................................................................................5
1.2 About this Manual...............................................................................................................................5
Limitation of Liability...........................................................................................................................5
Terms of Delivery...............................................................................................................................5
Copyright............................................................................................................................................6
Software licences...............................................................................................................................6
Warranty.............................................................................................................................................6
1.3 Reliability, Safety................................................................................................................................7
Applicability ........................................................................................................................................7
Target Group of the Instruction Manual .............................................................................................7
Intended Use......................................................................................................................................7
Reliability............................................................................................................................................7
Hazard and Other Warnings ..............................................................................................................8
Other Notices .....................................................................................................................................8
Electrical Safety..................................................................................................................................8
IT Security ........................................................................................................................................10
Electromagnetic Compatibility..........................................................................................................10
2 Product Description.......................................................................................................................................12
2.1 General Description..........................................................................................................................12
Software Releases...........................................................................................................................12
Hardware Versions...........................................................................................................................13
2.2 Application........................................................................................................................................14
Intended Use....................................................................................................................................14
Foreseeable Misuse.........................................................................................................................14
2.3 Technical Data..................................................................................................................................15
Vico MT ............................................................................................................................................15
Dimensions.......................................................................................................................................16
3 Construction and Functionality......................................................................................................................17
3.1 Brief Description ...............................................................................................................................17
3.2 Overview...........................................................................................................................................17
3.3 Labelling and Identification...............................................................................................................18
Name Plate.......................................................................................................................................18
Name Plate Details ..........................................................................................................................18
Serial Number ..................................................................................................................................19
3.4 Contents of Package ........................................................................................................................19
3.5 Transport and Storage......................................................................................................................20
3.6 Interfaces..........................................................................................................................................21
Power Supply "24VDC", (X1)...........................................................................................................22
Operative Earth (X11) ......................................................................................................................22
USB 2.0 host "USB1", "USB2" (X9).................................................................................................23
Ethernet "NET1" (X5).......................................................................................................................24
Ethernet "NET2" (X6).......................................................................................................................24
Serial Communication RS-232 "X12"...............................................................................................25
MicroSD Card (X3)...........................................................................................................................26
3.7 Indicators and Controls.....................................................................................................................27
Ethernet "NET1" (X5), "NET2" (X6) .................................................................................................27

Kendrion Kuhnke Automation GmbH Table of Contents
Vico MT (E 863 GB) 3
01/10/2021
3.8 Front .................................................................................................................................................27
Screen..............................................................................................................................................27
Backlight...........................................................................................................................................27
Touch ...............................................................................................................................................27
4 Installation and Operation..............................................................................................................................28
4.1 Mechanical Installation.....................................................................................................................28
Mounting Position.............................................................................................................................28
Front Panel Opening........................................................................................................................29
4.2 Electrical Installation.........................................................................................................................31
Operative Earth................................................................................................................................31
System Power Supply......................................................................................................................31
4.3 Putting into Service...........................................................................................................................33
General Start-up Information............................................................................................................33
Start-up Prerequisites ......................................................................................................................33
Turning on the Unit...........................................................................................................................33
Turning off the Unit...........................................................................................................................33
4.4 IT Security.........................................................................................................................................34
4.5 Configuration ....................................................................................................................................35
4.6 Diagnosis..........................................................................................................................................36
4.7 Table of Faults..................................................................................................................................36
4.8 Maintenance / Servicing...................................................................................................................37
General.............................................................................................................................................37
Servicing...........................................................................................................................................37
Preventive Maintenance...................................................................................................................37
4.9 Life Expectancy ................................................................................................................................38
Repairs / Customer Service.............................................................................................................38
Warranty...........................................................................................................................................38
Taking out of Service / Disposal.......................................................................................................38
5 System Configuration....................................................................................................................................39
5.1 Accessing the System Configuration................................................................................................39
5.2 Functions and Settings.....................................................................................................................39
Header..............................................................................................................................................39
Network ............................................................................................................................................39
Display..............................................................................................................................................40
Time Date.........................................................................................................................................40
Disks.................................................................................................................................................40
Fonts ................................................................................................................................................40
Access SystemConfig......................................................................................................................40
Access FTP Server ..........................................................................................................................40
Firewall (iptables).............................................................................................................................40
OpenVPN.......................................................................................................................................40
System Info & Access....................................................................................................................40
Resources Monitor.........................................................................................................................40
Process List....................................................................................................................................40
Log .................................................................................................................................................41
Log Persistent ................................................................................................................................41
Terminal .........................................................................................................................................41
Boot Script......................................................................................................................................41
Backup/Restore..............................................................................................................................41
System Backup/Restore (Live System) .........................................................................................41

Kendrion Kuhnke Automation GmbH Table of Contents
Vico MT (E 863 GB) 4
01/10/2021
Browser Settings............................................................................................................................41
Browser Log...................................................................................................................................41
5.3 System Functions.............................................................................................................................42
Keyboard..........................................................................................................................................42
Mouse Support.................................................................................................................................42
Run Linux Scripts Automatically.......................................................................................................42
Configuring the Web Browser ..........................................................................................................42
Installing Fonts.................................................................................................................................42
Configuring the Network...................................................................................................................42
6 Appendix........................................................................................................................................................43
6.1 Software Copyrights .........................................................................................................................43
6.2 Drawings...........................................................................................................................................44
Dimensions of Vico MT 727 .............................................................................................................44
Installation Opening of Vico MT 727................................................................................................45
Font View of Vico MT 727................................................................................................................45
Dimensions of Vico MT 1027 ...........................................................................................................46
Installation Opening of Vico MT 1027..............................................................................................47
Front View of Vico MT 1027.............................................................................................................47
Vico MT1527....................................................................................................................................48
Installation Opening of Vico MT1527...............................................................................................49
Front View of Vico MT1527..............................................................................................................49
6.3 Applicable Standards and Limits......................................................................................................50
EMC Standards................................................................................................................................50
Admissible Ambient Conditions........................................................................................................50
6.4 Regulations and Declarations...........................................................................................................51
Mark of Conformity...........................................................................................................................51
6.5 Approvals..........................................................................................................................................51
6.6 Order Specifications .........................................................................................................................52
Basic Units .......................................................................................................................................52
Accessories......................................................................................................................................53

Kendrion Kuhnke Automation GmbH Preface
Vico MT (E 863 GB) 5
01/10/2021
1 Preface
1.1 Legal Notice
Contact Details
Kendrion Kuhnke Automation GmbH
Industrial Control Systems
Lütjenburger Straße 101
D-23714 Malente, Germany
Tel. +49 4523 402-0
Fax +49 4523 402-201
Email sales-ics@kendrion.com
Email Support controltechnology-ics@kendrion.com
Internet www.kendrion.com
Version Details
Modification History
Date
Comments / Modifications
11.05.2021
Preliminary version
01.10.2021
Original version
22.12.2021
Corrections and enhancements
1.2 About this Manual
This technical information is primarily directed to system designers, project engineers and device developers.
It does not contain any availability information. We reserve the rights for errors, omissions and modifications.
Pictures are similar.
Limitation of Liability
Specifications are for description only and are not to be understood as guaranteed product properties in a
legal sense. Exact properties and characteristics shall be agreed in the specific contract. Claims for
damages against us - on whatever grounds - are excluded, except in instances of deliberate intent or gross
negligence on our part.
Terms of Delivery
The general conditions of sales and service of Kendrion Kuhnke Automation GmbH shall apply.

Kendrion Kuhnke Automation GmbH Preface
Vico MT (E 863 GB) 6
01/10/2021
Copyright
© Kendrion Kuhnke Automation GmbH
This instruction manual is proprietary and protected by copyright.
No part of this document may be reproduced or copied in any way or by any means except expressly
permitted in writing by Kendrion Kuhnke Automation GmbH.
Microsoft®, Windows® and the Windows® logo are registered trademarks of Microsoft Corp. in the USA and
other countries.
EtherCAT® is a registered trademark and patented technology, licenced by Beckhoff Automation GmbH,
Germany.
Further information about the PLCopen organisation is available at www.plcopen.org. CiA® and CANopen®
are registered Community trademarks of CAN in Automation e.V.
CODESYS©is a product of CODESYS GmbH.
i.MX8 is a registered trademark of Freescale
ARM ® and Cortex ® are registered trademarks of ARM Limited.
Modbus® is a registered trademark of the Modbus-IDA Organisation.
The companies mentioned herein own the property rights in their company, product and trade names.
Software licences
The units' firmware contains open source software. Some of this software is subject to the following and
other open source licences:
•GNU General Public License (GPL)
•MIT License
•BSD Zero Clause License
•GNU Lesser General Public License (LGPL)
•Mozilla Public License (MPL)
•FreeType License (FTL)
Within three years of delivery, customers may buy the source code of the free software from Kendrion
Kuhnke's product management at net costs.
CODESYS
Like all other CODESYS products, the CODESYS software version installed in this system is subject to
CODESYS GmbH's end user licence agreement (EULA) as published on the CODESYS website.
Warranty
Warranty is subject to the provisions of the conditions of sale of Kendrion Kuhnke Automation GmbH or any
contractual agreements between the parties.

Kendrion Kuhnke Automation GmbH Reliability, Safety
Vico MT (E 863 GB) 7
01/10/2021
1.3 Reliability, Safety
This chapter just summarises the most important safety instructions and notices, which you will find again in
the applicable chapters. Carefully read and respect the safety guidelines as they will provide protection
against personal injury and prevent material damage to the units.
Applicability
For reasons of personal safety and to avoid material damages when working with or handling this Kuhnke
product, you are advised to take heed of the notes and information contained in this instruction manual.
Target Group of the Instruction Manual
This instruction manual contains all information necessary for the use of the described product (control unit,
control terminal, software, etc.) according to instructions. It is written for design, project planning, servicing
and commissioning experts. For proper understanding and error-free application of technical descriptions,
instructions for use and particularly of notes of danger and warning, extensive knowledge of automation
technology is compulsory.
Intended Use
Kendrion's products are designed, developed and manufactured for standard industrial use. They must not
be used for any other purposes than the ones specified in the catalogue or the associated technical
documentation. Proper and safe operation depends on the products being transported, stored, lined up,
mounted, installed, put into service, operated, and serviced correctly. Ambient conditions must be within the
admissible limits. Notes and information in the associated documentation apply at all times. For details on
how to use this product as intended, refer to chapter 2.2 Application, Intended Use.
Reliability
Reliability of products is brought to the highest possible standards by extensive and cost-effective means in
their design and manufacture.
These include:
selecting high-quality components,
quality agreements with our suppliers,
actions to avoid static charges when handling MOS circuits,
worst case planning and design of all circuits,
visual inspections at various stages of fabrication,
computer-aided tests of all assemblies and their interaction in the circuit,
statistical assessment of the quality of fabrication and of all returned goods for the immediate taking
of appropriate corrective actions.

Kendrion Kuhnke Automation GmbH Reliability, Safety
Vico MT (E 863 GB) 8
01/10/2021
Hazard and Other Warnings
Despite the actions described hereunder, the occurrence of faults or errors in electronic control units - even if
most highly improbable - must be taken into consideration.
Please pay particular attention to the additional notices which we have marked by symbols throughout this
instruction manual. While some of these notices make you aware of possible dangers, others are intended
as a means of orientation. They are described further down below in descending order of importance.
Every alert and hazard warning is made up as follows:
Type and source of risk
Potential consequences of non-observance
Preventive measures
DANGER
A DANGER warning makes you aware of an immediately hazardous situation which WILL
cause a serious or fatal accident if not observed.
WARNING
A WARNING makes you aware of a potentially hazardous situation which MAY cause a
serious or fatal accident or damage to this or other devices if not observed.
CAUTION
A CAUTION alert makes you aware of a potentially hazardous situation which MAY cause
an accident or damage to this or other devices if not observed.
NOTE
A NOTE makes you aware of a potentially hazardous situation which MAY cause damage
to this or other devices if not observed.
Other Notices
Information
This symbol draws your attention to additional information concerning the use of the
described product. This may include cross references to information found elsewhere
(e.g. in other manuals).
Electrical Safety
Our products normally become part of larger systems or installations. The information below is intended to
help you integrate the product into its environment without dangers to humans or material/equipment.
DANGER
Non-observance of the instruction manual
Measures for the prevention of dangerous faults or errors may be rendered ineffective or new
hazard sources created.
Thoroughly read the instruction manual

Kendrion Kuhnke Automation GmbH Reliability, Safety
Vico MT (E 863 GB) 9
01/10/2021
Take particular heed of the hazard warnings
Information
To achieve a high degree of conceptual safety in planning and installing an electronic controller,
it is essential to exactly follow the instructions given in the manual because wrong handling could
lead to rendering measures against dangers ineffective or to creating additional dangers.
Project Planning
24 VDC power supply: generate as electrically safely separated low voltage. Suitable devices
include split-winding transformers built in compliance with European Standard EN 60742
(corresponds to VDE 0551).
Power breakdowns or power fades: the program structure is to ensure that a defined state at restart
excludes all dangerous states.
Emergency-off installations must comply with EN 60204/IEC 204 (VDE 0113). They must be
operative at any time.
Safety and precautions regulations for qualified applications have to be complied with.
Please pay particular attention to the notices of warning which, at relevant places, will make you
aware of possible sources of dangerous mistakes or faults.
Relevant standards and VDE regulations are to be complied with in every case.
Control elements are to be installed in such a way as to exclude unintended operation.
Lay control cables such that interference (inductive or capacitive) is excluded if this interference
could influence controller operation or its functionality.
Maintenance and Servicing
Precautions regulation BGV A3 (Elektrische Anlagen und Betriebsmittel) to be observed when
measuring or checking a controller after power-up. This applies to section 8 (Admissible deviations
when working on parts) in particular.
Only use parts approved of by Kendrion KUHNKE. Only genuine Kendrion KUHNKE modules may
be used in modular controllers.
Modular systems: always plug or unplug modules in a power-down state. You may otherwise
damage the modules or (possibly not immediately recognisably!) inhibit their functionality.
Always dispose of (rechargeable) batteries as hazardous waste.

Kendrion Kuhnke Automation GmbH Reliability, Safety
Vico MT (E 863 GB) 10
01/10/2021
IT Security
Kendrion Kuhnke products are designed for use in closed (private) industrial network environments.
In case such industrial networks are open to public access (e.g. via fully accessible network interfaces) or
otherwise externally accessible (e.g. via data links and public (Internet) traffic), the integrator and operator
must take appropriate organisational and technical precautions to protect the in-house network and ensure
IT security.
Information
To find information about how to safely operate equipment, systems and networks, please refer
to the texts published by BSI (Federal Office for Information Security), other publicly available
sources and IEC 62443.
Electromagnetic Compatibility
Definition
Electromagnetic compatibility is the ability of a device to function satisfactorily in its electromagnetic
environment without itself causing any electromagnetic interference that would be intolerable to other
devices in this environment.
Of all known phenomena of electromagnetic noise, only a certain range occurs at the location of a given
device. It is defined in the relevant product standards.
The design and immunity to interference of programmable logic controllers are internationally governed by
standard
IEC 61131-2 which, in Europe, has been the basis for European Standard
EN 61131-2.
Information
Refer to IEC 61131-4, User's Guideline, for general installation instructions to be complied with
to ensure that hardware interface factors and the ensuing noise voltages are limited to tolerable
levels.
Interference Emission
Interfering emission of electromagnetic fields, HF
compliant to EN 55011, limiting value class A, Group 1
Information
If the controller is designed for use in residential areas, high-frequency emissions must comply
with limiting value class B as described in EN 55011.
Fitting the controller into earthed metal cabinets and installing filters in the supply lines and other
means may produce a shielding compliant to the above standard.
General Notes on Installation
As component parts of machines, facilities and systems, electronic control systems must comply with valid
rules and regulations, depending on their field of application.
General requirements concerning the electrical equipment of machines and aiming at the safety of these
machines are contained in Part 1 of European Standard EN 60204 (same as VDE 0113).
Electrical Immission Safeguard
To eliminate electromagnetic interference, connect the control system to the protective earth conductor.
Practice best cable routing.

Kendrion Kuhnke Automation GmbH Reliability, Safety
Vico MT (E 863 GB) 11
01/10/2021
Cable Routing and Wiring
Keep power circuits separate from control circuits:
DC voltages 60 V ... 400 V
AC voltages 25 V ... 400 V
Joint laying of control circuits is allowed for:
shielded data signals
shielded analogue signals
unshielded digital I/O lines
unshielded DC voltages < 60 V
unshielded AC voltages < 25 V
Location of Installation
Ensure that temperatures, contaminations, impact, vibration or electromagnetic interference are no
impediment to the installation.
Temperature
Consider heat sources such as general heating of rooms, sunlight, heat accumulation in assembly rooms or
control cabinets.
Contamination
Use suitable casings to avoid possible negative influences due to humidity, corrosive gas, liquid or
conducting dust.
Impact and Vibration
Consider possible influences caused by motors, compressors, transfer lines, presses, ramming machines
and vehicles.
Electromagnetic Interference
Consider electromagnetic interference from various local sources: motors, switching devices, switching
thyristors, radio-controlled devices, welding equipment, arcing, switched-mode power supplies, converters /
inverters.
Particular Sources of Interference
Inductive Actuators
Switching off inductances (such as from relays, contactors, solenoids or switching magnets) produces surge
voltages. It is necessary to reduce these extra voltages to a minimum.
Reducing elements may be diodes, Z-diodes, varistors or RC elements. Their rating should conform to the
specifications provided by the manufacturer or supplier of the actuators.

Kendrion Kuhnke Automation GmbH Product Description
Vico MT (E 863 GB) 12
01/10/2021
2 Product Description
2.1 General Description
Vico MT panel series devices are designed for use as a multi-touch control panel in industry and building
automation. By default, the panels feature a high-quality, high-resolution display with a large aspect angle
and a powerful Quad Core™ Arm® i.MX8 CPU.
The sturdy touch screen resides in an aluminium or stainless steel frame specifically designed for industrial
environments. Standard panel models provide IP65 protection at the front and are fit for installation in
switching cabinets or control desks.
Their operating system is embedded Linux (Yocto Distribution). The on-board Web Configurator provides
access to many different settings for the simple setup of your network, browser look and behaviour,
keyboard and language settings, a boot screen or screen saving showing your logo and many other
properties.
Software Releases
Various software options or combined software options are available for installation in the devices. Please
ask product management for the combination that best fits your needs.
Software Releases
Option
Identification
Function
CODESYS HMI
HMI
Create modern visualisations of machines and systems
straight in the CODESYS Development System and run Vico
HMI units to display them for operation or diagnosis. Note that
visualisation projects may but need not be linked to the logical
application (i.e. your IEC 61131-3 project). Instead, they may
connect to several different CODESYS-compatible control
units at the same time.
WEB
WEB
The on-board tool kit includes a HTML5 Chromium browser
optimised for high performance in combination with a simple
and user-friendly configuration plus sophisticated software
add-ons for the specific needs of industry users.

Kendrion Kuhnke Automation GmbH Product Description
Vico MT (E 863 GB) 14
01/10/2021
2.2 Application
Intended Use
The panel is designed for on-site use in industrial environments immediately at the machine. It installs in
switching cabinets, switching or control panels.
This series provides devices and equipment manufacturing with a visualisation unit for different applications:
Place of installation
If installed in an enclosed space, the unit's front is protected against dust and water. Ingress protection at the
back is IP 20 where it should be protected against humidity and dirt separately.
Waste heat develops in the rear part of the unit. Verify that the place of installation is ventilated properly.
NOTE
Damage to the unit
Choosing the wrong place of installation may cause damage to the unit.
Check section Technical Data for the admissible ambient conditions and the unit's
mounting position.
Foreseeable Misuse
Do not use in explosive atmospheres!
DANGER
Do not use in explosive atmospheres!
Using the unit in explosive atmospheres may cause death or serious personal or property
damage.
The unit is neither designed nor approved for use in explosive atmospheres.
Do not use in domestic areas!
WARNING
This unit is solely designed for use in industrial environments and may provoke radio
interference at home. Take the appropriate precautions before using it at home.
Design constraints for high-risk use cases
The product is neither designed nor intended for use in customer systems or together with third-party
materials which have been shown to potentially cause fatal or serious personal injury or material or
environmental damage if the product fails or produces a fault ("High Risk Use ").
High-risk use applications are strictly prohibited.
DANGER
Danger caused by malfunctions
Fatality, serious personal injury or serious material or environmental damage
High-risk use applications are strictly prohibited.

Kendrion Kuhnke Automation GmbH Product Description
Vico MT (E 863 GB) 15
01/10/2021
2.3 Technical Data
Vico MT
General Specifications
Product name
Vico MT 727
Vico MT 1027
Vico MT 1527
Screen size / aspect ratio
7" / 17:10 10.1" / 16:10 15.6"/ 16:9
Resolution
1024 x 600 / (17:10) 1280 x 800 / (16:10) 1366 x 768 / (16:9)
Screen size
154.21 x 86.92 mm
217 x 135.6 mm
344.2 x 193.4 mm
Colours
16.7 million
Aspect angle
85°/85°/85°/85°
80°/80°/80°/80°
85°/80°/85°/85°
Brightness
450 cd/m²
420 cd/m²
400 cd/m²
Touch screen
Capacitive multi-touch (5 fingers)
Backlight
White LED, dimmable, life > 50000h (@ 50% brightness)
Processor
ARM Cortex A53, i.MX8Mmini quad-core CPU, 4x 1.6 GHz
Clock
Processor resource, no buffer, NTP synchronisation supported
Software
Operating system: embedded Linux (Yocto Distribution)
RAM / remanent memory
1 Gbyte DDR4-RAM
Disk drives
4 Gbyte eMMC ROM, 2 Mbyte NOR flash, 1x MicroSD card slot, up to SDXC
Networks
1x Ethernet 1 Gbit – RJ45, 1x Ethernet 10/100(1000) Mbit – RJ45
Ports
2x USB 2.0 host, 1x RS-232 (no electrical insulation)
Power supply
24 VDC (+20% /- 20%)
Power consumption
550 mA
580 mA
610 mA
Service conditions
Mounting position
Vertical; please contact product management for other mounting positions
Storage temperature
-20 °C...+70 °C
Operating temperature
0 °C...+55 °C, if installed vertically only
Rel. humidity
Front: 100% / installation space: 10...95% (@ 25 °C)
Degree of contamination
Degree 2 to IEC 61010-1
Working altitude
max. 3000 m a.s.l.
Front durability
Atmosphere free from corrosive or explosive gases
Mechanical properties
Back of housing
IP 20, stainless steel, aluminium sheet housing
Front panel
IP 65 chemically strengthened glass front
resides in milled aluminium frame (with end caps)
optically bonded optically bonded air gap
Installation
In front panel cutout using quick-mount hardware
Weight
0.82 kg
1.25 kg
3.4 kg
Dimensions (WxHxD)
200.1 x 131.9 x 47.4 [mm] 264.5 x 187 x 40.9 [mm] 404.5 x 253.5 x 59.4 [mm]
Mounting depth
42.4 mm
35.5 mm
53 mm

Kendrion Kuhnke Automation GmbH Product Description
Vico MT (E 863 GB) 17
01/10/2021
3 Construction and Functionality
3.1 Brief Description
The panel's powerful processor board with integrated touch screen allows users to run all display and
operating functions in a single unit.
It is designed for on-site use immediately at the machine. Mechanical, system and cabinet engineers benefit
from the unit's flexibility when designing powerful applications with a small footprint.
3.2 Overview
Name plate and
software licences
Operative earth
connector
Processor unit
Front panel
Screen opening
Connectors

Kendrion Kuhnke Automation GmbH Construction and Functionality
Vico MT (E 863 GB) 18
01/10/2021
3.3 Labelling and Identification
Name Plate
Name Plate Details
X3
MicroSD
X5
NET1
X9
USB2
USB1
X1
Power
FE | 0V | 24V
X6
NET2
X12
RS232
Kendrion Kuhnke AutomationGmbH
Lütjenburger Strasse 101
23714 Malente, Germany
Vico MT 727
⎓24 V / 550 mA max.
Typ: CODESYS HMI
OrderNo.: 677 810 01
Ident.No. 199888
Prot.: IP 65, IP20
Def.IPNet1:192.168.0.227 21080300270
Typ: CODESYS HMI
OrderNo.: 677 810 01
Ident.No. 199888
Prot.: IP 65, IP20
Def. IP:192.168.0.227
Name plate
Serial number
Production label
Model
Software release
Part number
Default IP address for NET 1

Kendrion Kuhnke Automation GmbH Construction and Functionality
Vico MT (E 863 GB) 19
01/10/2021
Serial Number
The numerical code incorporates the production date and a serial number. Kendrion Kuhnke can use the
numerical code to distinctly identify the model, software and hardware release date. It is a means of
traceability.
Make-up of serial number:
YY MM DD NNNNN
Example:
The unit shown above was manufactured on 03rd August 2021 and has the serial number 00270.
21 08 03 00270
3.4 Contents of Package
The Vico MT package includes:
Basic unit, supplement, power supply connector, mounting elements, which are already pre-assembled on
the Vico MT 1027 and Vico MT 1527 devices.
five-digit number of nth unit built on that day
production date as year month day

Kendrion Kuhnke Automation GmbH Construction and Functionality
Vico MT (E 863 GB) 20
01/10/2021
3.5 Transport and Storage
Despite the unit's rugged construction, its components inside are still sensitive to impact and vibration.
Transport and keep the unit in its original packaging and ensure that the ambient conditions are as specified
at all times during transport and storage. Refer to manual section 9.6.3 Admissible Ambient Conditions for
admissible ambient and transport condition details.
NOTE
Humidity
Damage to the unit
Verify that no moisture (condensation) is able to collect on the unit when transporting it in
cold temperatures or if it is exposed to extremely varying temperatures. Allow the unit to
slowly warm up to room temperature before putting it into operation.
This manual suits for next models
2
Table of contents
Other Kendrion Touch Panel manuals