............ www.truemfg.com ............
True Food Service Equipment, Inc.
33
Beforeyournewdisplaycaseisconnectedtoapower
supply,checktheincomingvoltagewithavoltmeter.
Ifanythinglessthan100%oftheratedvoltagefor
operationisnoted,correctimmediately.
Havethecircuitcheckedbyaqualifiedelectricianto
makesureitisproperlygrounded.
Thedisplaycaseshouldalwaysbeuseit’sownindividual
electricalcircuit,whichhasavoltageratingthatmatches
theratingplate.
Thisprovidesthebestperformanceandalsoprevents
overloadingbuildingwiringcircuitswhichcouldcausea
firehazardfromoverheatedwires.
For models with standard power cord.
Thepowercordofthisapplianceisequippedwitha
groundingplugwhichmateswithastandardgrounding
walloutlettominimizethepossibilityofelectricshock
hazardfromthisappliance.
Havethecircuitcheckedbyaqualifiedelectricianto
makesureitisproperlygrounded.
Iftheoutletisastandard2-prongoutlet,itisyour
personalresponsibilityandobligationtohaveitreplaced
withtheproperlygroundedwalloutlet.
Thedisplaycaseshouldalwaysbepluggedintoit’sown
individualelectricalcircuit,whichhasavoltagerating
thatmatchestheratingplate.
Thisprovidesthebestperformanceandalsoprevents
overloadingbuildingwiringcircuitswhichcouldcausea
firehazardfromoverheatedwires.
Neverunplugyourdisplaycasebypullingonthepower
cord.Alwaysgripplugfirmlyandpullstraightoutfrom
theoutlet.
Repairorreplaceimmediatelyallpowercordsthathave
becomefrayedorotherwisedamaged.Donotuseacord
thatshowscracksorabrasiondamagealongitslengthor
ateitherend.
Whenremovingthedisplaycaseawayfromthewall,be
carefulnottorolloverordamagethepowercord.
HOW TO CONNECT ELECTRICITY
Hard wiring is required on specific Display Cases.
Models standard with power cords: Do not, under any circumstances, cut or remove the ground prong from the power cord.
For personal safety, this appliance must be properly grounded.
WARNING!
NOTE
Hard wired models do not use this receptacle.
USE OF ADAPTER PLUGS
NEVER USE AN ADAPTER PLUG! Because of potential safety hazards under certain conditions, we strongly recommend
against the use of an adapter plug.
SAFETY INFORMATION
NEMAplugs
TRUEusesthesetypesofplugs.If
youdonothavetherightoutlethave
acertifiedelectricianinstallthecorrect
powersource.
115/60/1
NEMA-5-20R
115/60/1
NEMA-5-20R
115/208-230/1
NEMA-14-20R
115/60/1
NEMA-5-15R
208-230/60/1
NEMA-6-15R
NEMA plug configurations
T-Series and GDM Freezers
Spec Series same as T-Series
Back Bar
Milk Coolers
TSSU
TPP
TWT
TUC
TRCB
T-Series and GDM Refrigerators
Double Duty, Single Duty, Curved Glass
Horizontal Freezers
GDIM
TAC (Air Curtain)