ttaf RGN-04 User manual

UV-C RAGNAR
RGN-04
USER MANUAL

Thank you for purchasing our products.
Please read the instructions carefully before rst use,
so that you can fully understand and install this product.
Please keep it after reading the manual.

• UV-C Ragnar Germicidal Fixture, sterilizes its environment with strong
UV-C radiation.
• 360 ° Coverage Area: UV-C Ragnar Disinfection Fixture provides
sterilization with 3 tubes surrounding it.
• It is an easy-to-install, practical, robust and user-friendly sterilization
device.
• UV-C Ragnar Germicidal Fixture, detects motion up to 5m distance by its
motion sensor. Sterilization stops automatically when it detects motion.
Basic Characteristics
Product Code
Operation Voltage
Power Consumption
Light Source
UV Wavelength
Irradiance
Human Body Sensing
Dimensions
Weight
Other Features
:
:
:
:
:
:
:
:
:
:
RGN-04
220~240VAC 50/60Hz
95W
UV-C Tube
254nm
1,16W/m @1m
~5m
Ø300x1450mm
10kg
Delayed operation to leave the room
• Sterilization time is set at the factory to an hour duration before sending
to the user. At the end of this period, the area with a maximum radius of
4 meters is sterilized.
this case, you need to get technical support from our factory. For
technical support;
teknikdestek@ttaf.com.tr
Sterilization Time

1. Place the dowels on the surface you hole.
2. Assemble the product using screws.
3. Plug the device into the socket.
4. The device will give the rst 20 seconds to the user to leave the room.
Meanwhile, the yellow warning light will ash and an audible warning will
sound.
5. When the device starts the sterilization process, the red warning light will turn
on.
6. When the sterilization process is completed, the green warning light will turn
on.
7. When motion is detected during the sterilization process, the UVC radiation will
be cut o and an audible warning will sound while the yellow light is on. If the
detected movement is shorter than 5 seconds and is not continuous,
sterilization continues.
8. When motion is detected for the 3rd time after this warning, the system is
completely will be cut o.
9. Continuous ashing red light indicates that the operation was motion detected
in the sterilization period, the process was interrupted and sterilization was not
completed. In this case, the sterilization process must be repeated.
10. The yellow warning light and the red light ashing 3 times after the audible
warning indicate that the operation was interrupted due to motion detection
during the nal stages of the sterilization period, but the environment was
sterilized by at least 90%. In this case, the user can decide whether the
sterilization will be repeated or not.
11. The sterilization time of the device is set as 1 hour. At the end of this period it
sterilizes the area with a radius of 4 meters.
12. Sterilization time can be adjusted according to the room size. Please check
Sterilization Time
section for sterilization time setting.
Installation and Operation Steps

WARNINGS
1. Please strictly refer to the operating instructions.
2. Do not dismantle the product or replace any parts on your own.
3. Please make sure that people, animals and plants are removed from the area
to protect them from UV rays during the disinfection process.
4. Please do not look into the light when operating, to avoid hurting your eyes
and skin. Exposure to UV-C rays is extremely harmful for both animal and
human health. May cause permanent discomfort.
5. Do not knock or drop the product, otherwise it may damage the product or
the lamp tube.
6. When the device encounters falling to the ground, breaking, being damaged
by natural disasters or being exposed to any impact, the particles of the
product should be collected with the help of a brush, carefully collected with
the help of a brush, and the area should be ventilated. A waste box with the
code of
20 01 21
(Fluorescent Lamp and Wastes Containing Other
Mercury)
must be created and separated from other wastes.
7. The main source of danger is mercury vapor contained in the tubes. When
the tube breaks, it evaporates immediately. Up to 3 mg of mercury has been
used per tube.
Attention
1. If the power is on but the light does not work, please check whether the
power plug is properly connected to the power supply.
2. Please choose the correct input voltage for this product.
power supply immediately and contact our company.
5. To avoid electric shock, do not place the high-voltage AC plug in a damp or
wet place.
6. The lifetime of the UV-C tube is more than 8000 hours. For UV-C tube
replacement, you need to get technical support from our company. For
technical support;
teknikdestek@ttaf.com.tr

/ttafelectronc
Kavaklı Mh. İstanbul Cd. No:21
Beylikdüzü -İstanbul /TÜRKİYE
Tel
Fax
+90 212 855 82 20 (Pbx)
+90 212 855 82 21
:
:
www.ttafmedikal.om