manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TTC
  6. •
  7. Security Sensor
  8. •
  9. TTC D740KIT User manual

TTC D740KIT User manual

RETURN FOR REPAIR POLICY
Every effort has been made to provide reliable, superior quality
products. However, in the event your instrument requires repair,
forward unit to Service Center freight prepaid to the address below
with return address, phone number and/or email address.
TECHNO TOOLS CORPORATION
SERVICE CENTER
2651 W 81st Street
Hialeah, FL 33016
WARRANTY POLICY
The D740 H2/N2 Tracer Gas Leak Detector is warranted to be free
of defects in materials and workmanship for a period of two years
from the date of purchase. This warranty applies to all repairable
instruments that have not been tampered with or damaged through
improper use including unauthorized opening of the unit. Please
ship warranty units that require repair freight prepaid to Service
Center along with proof of purchase, return address, phone number
and/or email address.
Call Toll Free: 800-222-0956
Fax: 786-235-1202
Revised 10/16/2017
Model
D740KIT
Tracer Gas (5%H2/95%N2) A/C
System Dealership Leak
Detection Service Kit
Instructions for Use
The D740KIT is d
esign
certified by ACSI to meet
SAE J2790
D740KIT Instructions for Use
1. While diagnosing the vehicle’s A/C system you must first
determine the state of the refrigerant charge, i.e. full, low,
empty.
2. If it is suspected that there is an A/C leak in the system, and
there is some refrigerant in the system, use an SAE certified
refrigerant leak detector such as the D440A or the D440A-UV
to locate the leak/s. Mark the location of the leak/s for a future
repair once the system has been professionally evacuated
using you SAE certified refrigerant recovery/charging machine.
3. Be certain to pull a vacuum on the vehicle’s A/C system using
your SAE certified refrigerant recovery/charging machine.
4. Preparing to charge the A/C system with H2/N2 tracer gas,
connect the regulator to the tracer gas tank (a 100 pound tank
to be supplied by a local dealer, can be purchased from local
welding gas company such as Airgas).
5. Connect the hose to the regulator.
6. Connect the appropriate service port coupler fitting for systems
charged with either R134a or R1234yf.
7. If vehicle is an Electric or a Hybrid vehicle with a battery chiller
you may have to activate the battery chiller(s) to open the
solenoid(s) to allow vacuum and gas to pass through to chiller
for leak testing. Refer to shop manual refrigerant reclaim and
charging to see if solenoid(s) activation is necessary. Follow
the shop manual procedure to perform activation if needed.
8. Be sure that the coupler is in the closed position. Open the
valve on the supply H2/N2 tracer gas tank to charge the A/C
system. Adjust the regulator to 60 psi. Loosen the hose fitting
to the service port coupler a little until the tracer gas is
released to purge the air from the hose then tighten the hose
fitting to the service port coupler. Connect the service port
coupler from the H2/N2 tracer gas test kit
1
to the high side service port on the vehicle an
d open the
service port coupler.
9. Allow 30 seconds for the tracer gas to fill the system.
10. Use the model D740 H2/N2 leak detector that is included with
the D740KIT to check for system leaks. Follow the operating
instructions for use supplied for the model D740 leak detector.
11. When leak checking a fitting and or hose connections go all
the way around the component. H2/N2 tracer gas raises and
is defused into the atmosphere; it does not fall to the ground
as in the case with R134a or R1234yf refrigerant.
12. Discharge the H2/N2 tracer gas into the atmosphere after the
system leak/s are located. ( Do not ever recover the tracer gas
into an A/C recovery/charging machine). Charge the system
with the appropriate R134a or R1234yf refrigerant only after
the leak/s are repaired and retested with the H2/N2 tracer gas
and the model D740 leak detector.
13. Continue the remainder of repair/assembly using the WSM.
Replacement Parts
Item Part Number
Tracer Gas 90 PSI Regulator AC-REG0001
R134a Manual Service Coupler (Red) AC-VAL0001R
R1234yf Manual Service Coupler (Red) AC-VAL0002R
8 Foot Service Hose, Red AC-HOS096R
18”Carrying Case AC-CAS0010
D740 Refrigerant Leak Detector D740
2

Popular Security Sensor manuals by other brands

DOL 104 4-20 mA Technical user guide

DOL

DOL 104 4-20 mA Technical user guide

EMX Industries OWL quick start guide

EMX Industries

EMX Industries OWL quick start guide

Pilz PNOZ mc3p operating manual

Pilz

Pilz PNOZ mc3p operating manual

jablotron JA-151P-WG quick start guide

jablotron

jablotron JA-151P-WG quick start guide

Trader ARCTIC OWL OWPIROD quick start guide

Trader

Trader ARCTIC OWL OWPIROD quick start guide

Siemens FDOOT271 Technical manual

Siemens

Siemens FDOOT271 Technical manual

Major tech MT222 instruction manual

Major tech

Major tech MT222 instruction manual

Perenio PECMS01 quick start guide

Perenio

Perenio PECMS01 quick start guide

Clas Ohlson 36-2932 user guide

Clas Ohlson

Clas Ohlson 36-2932 user guide

RKI Instruments 35-3001A-01 1 Series Operator's manual

RKI Instruments

RKI Instruments 35-3001A-01 1 Series Operator's manual

EscortRadar REDLINE 360c quick start guide

EscortRadar

EscortRadar REDLINE 360c quick start guide

Martec Microdata Due MD9900-BS Series quick start guide

Martec

Martec Microdata Due MD9900-BS Series quick start guide

Art ROPEGUIDE 2010 instruction manual

Art

Art ROPEGUIDE 2010 instruction manual

DEGA 05L-2-AC-x-yL instruction manual

DEGA

DEGA 05L-2-AC-x-yL instruction manual

Potter PAD200-DUCT installation manual

Potter

Potter PAD200-DUCT installation manual

Security-Center FU5125 installation guide

Security-Center

Security-Center FU5125 installation guide

Satelco MPD-300 manual

Satelco

Satelco MPD-300 manual

GEZE GC 173 Supplementary sheet

GEZE

GEZE GC 173 Supplementary sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.