Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 1|4
RU40U-M18E-LU8X2-H1151 | 05-04-2022 12-06 | Technical modifications reserved
RU40U-M18E-LU8X2-H1151
Ultrasonic Sensor – Diffuse Mode Sensor
Technical data
Type RU40U-M18E-LU8X2-H1151
ID 1610109
Ultrasonic data 
Function Proximity switch
Range 25…400mm
Resolution 0.5mm
Minimum measuring range 50mm
Minimum switching range 50mm
Ultrasound frequency 300kHz
Repeat accuracy ≤0.15% of full scale
Temperature drift ±1.5% of full scale
Linearity error ≤ ±0.5%
Edge lengths of the nominal actuator 20mm
Approach speed ≤3m/s
Pass speed ≤1.3m/s
Electrical data 
Operating voltage 15…30VDC
Residual ripple 10% Uss
DC rated operational current ≤150mA
No-load current ≤50mA
Load resistance ≤1000Ω
Response time typical <60ms
Readiness delay ≤300ms
Output function Analog output
Output 1 Analog output
Voltage output 0…10V
Features
■Smooth sonic transducer face
■Cylindrical housing M18, potted
■Connection via M12 x 1 male
■Teach range adjustable via adapter
■Temperature compensation
■Blind zone: 2.5cm
■Range: 40cm
■Resolution: 0.5mm
■Aperture angle of sonic cone: ±15 °
■1×analog output, 0…10V/additional
switching output, PNP
Wiring diagram
Functional principle
Ultrasonic sensors capture a multitude of
objects contactlessly and wear-free with
ultrasonic waves. It does not matter whether
the object is transparent or opaque, metallic
or non-metallic, firm, liquid or powdery. Even
environmental conditions such as spray, dust
or rain hardly affect their function.
The sonic cone diagram indicates the
detection range of the sensor. In accordance
with standard EN 60947-5-7, quadratic targets
in a range of sizes (20×20 mm, 100×100
mm) and a round rod with a diameter of
27mm are used.
Important: The detection ranges for other
targets may differ from those for standard
targets due to the different reflection
properties and geometries.
Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 2|4
RU40U-M18E-LU8X2-H1151 | 05-04-2022 12-06 | Technical modifications reserved
Technical data
Load resistance voltage output ≥1kΩ
Switching frequency ≤10.4Hz
Short-circuit protection yes / Cyclic
Reverse polarity protection yes
Wire breakage protection yes
Setting option Remote Teach
Mechanical data 
Design Threaded barrel,M18
Radiation direction straight
Dimensions Ø18x75mm
Housing material Metal, CuZn, Nickel Plated
Max. tightening torque of housing nut 20Nm
Transducer material Plastic, Epoxyd resin and PU foam
Electrical connection Connector,M12 × 1,5-wire
Ambient temperature -25…+70°C
Storage temperature -40…+80°C
Protection class IP67
Switching state LED,Yellow
Object detected LED,Green
Tests/approvals 
MTTF 202years acc. to SN 29500 (Ed. 99) 40
°C
Declaration of conformity EN ISO/IEC EN 60947-5-7
Vibration resistance IEC 60068-2
Approvals CE
cULus
Sonic Cone
Mounting instructions
Mounting instructions/Description
Setting the limit values
The ultrasonic sensor has an analog output
with teachable measuring range. Teaching is
implemented via the teach adapter. The green
and yellow LEDs indicate whether the sensor
has detected the object.

Teach
Connect the TX1-Q20L60 teach adapter
between the sensor and connection cable
• Position object for remote limit value
• Press the button against Ub for 2 - 7
seconds
• Position object for close limit value
• Press the button against Ub for 8 - 11
seconds
Optional: Inversion of analog output
• Press the button for 12 - 17 seconds

LED response
Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 3|4
RU40U-M18E-LU8X2-H1151 | 05-04-2022 12-06 | Technical modifications reserved
Successful teaching is displayed with a
fast flashing LED. Thereafter, the sensor
automatically runs in normal operating mode.
Unsuccessful teaching is indicated by the LED
flashing alternately green and yellow.
In normal operation, the two LEDs indicate the
status of the sensor.
• Green: Object within the detection range, but
not in the measuring range
• Yellow: Object is within the measuring range
• Off: Object outside the detection range or
signal loss
Accessories
MW-18 6945004
Mounting bracket for threaded barrel
sensors; material: Stainless steel A2
1.4301 (AISI 304)
Accessories
Dimension drawing Type ID
RKC4.5T-2/TEL 6625016 Connection cable, female M12, straight,
5-pin, cable length: 2 m, sheath
material: PVC, black; cULus approval;
other cable lengths and qualities
available, see www.turck.com
WKC4.5T-2/TEL 6625028 Connection cable, female M12, angled,
5-pin, cable length: 2 m, sheath
material: PVC, black; cULus approval;
other cable lengths and qualities
available, see www.turck.com
Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 4|4
RU40U-M18E-LU8X2-H1151 | 05-04-2022 12-06 | Technical modifications reserved
Accessories
Dimension drawing Type ID
TX1-Q20L60 6967114 Teach adapter for inductive encoders,
linear position, angle, ultrasonic and
capacitive sensors

Other turck Security Sensor manuals

turck RU100U-EMT18M-UP8X2-H1151 User manual

turck

turck RU100U-EMT18M-UP8X2-H1151 User manual

turck FCS-G NAEX0 Series User manual

turck

turck FCS-G NAEX0 Series User manual

turck FCS-G3/4A4-NAEX/L080/D100/D093 User manual

turck

turck FCS-G3/4A4-NAEX/L080/D100/D093 User manual

Popular Security Sensor manuals by other brands

BARRON EXITRONIX 400E Series installation instructions

BARRON

BARRON EXITRONIX 400E Series installation instructions

Tomar 4375 Installation, operation and maintenance

Tomar

Tomar 4375 Installation, operation and maintenance

Leuze electronic ERS200-M0C3-M20-HLR operating instructions

Leuze electronic

Leuze electronic ERS200-M0C3-M20-HLR operating instructions

AMS OSRAM TCS3530 EVM quick start guide

AMS

AMS OSRAM TCS3530 EVM quick start guide

Omron WheezeScan instruction manual

Omron

Omron WheezeScan instruction manual

Pyronix KX15DTAM manual

Pyronix

Pyronix KX15DTAM manual

AJAX FireProtect quick start guide

AJAX

AJAX FireProtect quick start guide

ELRO FH721011 instruction manual

ELRO

ELRO FH721011 instruction manual

Niko Swiss Garde 300 Prasenz UP Max installation instructions

Niko

Niko Swiss Garde 300 Prasenz UP Max installation instructions

Honeywell LightSpot LS1000R Installation and operating instructions

Honeywell

Honeywell LightSpot LS1000R Installation and operating instructions

Honeywell MIDAS-T-HTP quick start guide

Honeywell

Honeywell MIDAS-T-HTP quick start guide

Siemens OH720 Technical manual

Siemens

Siemens OH720 Technical manual

Deta SILENT 100 230V User instructions

Deta

Deta SILENT 100 230V User instructions

Visonic MP-841 installation instructions

Visonic

Visonic MP-841 installation instructions

FRIEDLAND Magnetic Contact Installation and operating instructions

FRIEDLAND

FRIEDLAND Magnetic Contact Installation and operating instructions

Clas Ohlson ST-09 instruction manual

Clas Ohlson

Clas Ohlson ST-09 instruction manual

Bosch AVIOTEC IPSTARLIGHT 8000 Planning Manual

Bosch

Bosch AVIOTEC IPSTARLIGHT 8000 Planning Manual

Velleman ZLUV220 user manual

Velleman

Velleman ZLUV220 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.