Tycon Power Systems Wireless EZ-Bridge LT2 Series Manual

Tycon Systems 14641 S 800 W Bludale UT 84065 tyconsystems.com Page 1
EZ-Bridge ®- LT2 Series Inial Set-Up Procedure and Checklist
Thank you for choosing the EZ-Bridge® Wireless Antenna System.
Each Antenna system is factory tested and pre-congured so that most applicaons
are truly “Plug and Play”
Some package models will require addional user-provided Ethernet Cat5/6 jumper cables to
complete the necessary connecons between each Antenna, each PoE Injector and your
Network Devices.
O Unbox all system components within the same room on a non-conducve table or oor.
O Idenfy and keep separate Antenna “A” and Antenna “B” as each will be inialized separately.
(The PoE wall pack injectors are idencal and may be used with either antenna)
Step One: Begin set-up procedure for Antenna “A”
— With the PoE wall-pack injector unplugged from AC power —
O Remove the boom cover from the antenna housing to access the connecon points.
O Insert one end of a CAT5/6 jumper cable into the center RJ45 port. (Center Port aligns with the cover)
and the other end into the “PoE” port of the injector as shown.
IMPORTANT! Before installing any devices, please read all of
the cauons and warnings contained in the system manual.
Warning! These antennas ulize (12 –24 VDC)
Do not connect to Standard PoE Power Sources.
Higher voltages will damage units and void
the warranty
O With another CAT5/6 jumper cable, insert one end into the “LAN” port of the
Injector and the other end into a spare data port of your Switch or Router that is
Connected to an Internet source as shown at the top of page 2.
Cat 5/6
Jumper
7 August 2019

Tycon Systems 14641 S 800 W Bludale UT 84065 tyconsystems.com Page 2
Antenna “A”
PoE Injector Router or Switch
PC
Internet Source
O With your PC Powered on, plug the Injector into a constant 110 VAC power outlet.
— The Antenna should begin the boot-up process (Inializaon).
— You should see the green LED illuminate to indicate power is present.
— You should hear two short beeps when the Antenna has completed a proper inializaon.
O If proper Inializaon happened, leave this conguraon as is and in a powered-on state.
O If Inializaon did not happen properly, please contact Technical Support for assistance.
Supp[email protected]m
CAT5/6
Jumper
Green
Power “On” LED
Step Two: Antenna “B” Inializaon
— With the PoE wall–pack Injector unplugged from the wall outlet —
O Remove the boom cover to access the connecon points.
O Insert one end of a CAT5/6 jumper cable into the center port of the antenna
and the other end into the “PoE” port of the injector as shown below.
CAT5/6
Jumper
O Plug the Injector into a constant 110 VAC wall outlet.
— The Antenna should begin the boot-up process (inializaon).
— You should see the green LED illuminate to indicate power is present.
— You should hear two short beeps when the Antenna has completed a proper inializaon.
O If proper Inializaon happened, go to page 3 for next steps.
O If Inializaon did not happen properly, please contact Technical Support for assistance.
Support@tyconsystems.com
Green
Power “On” LED
No Connecon to the “LAN” port
at this me.

Tycon Systems 14641 S 800 W Bludale UT 84065 tyconsystems.com Page 3
Step two connued:
O Using a dierent PC ( the WiFi feature disabled ) connect a CAT5/6 jumper cable
from the “LAN” port of the Injector to the Data port of your PC as shown below.
POE LAN
Data Port
O Arrange the Antennas within the same room so there is at least
an 8 foot separaon as shown below.
8 . Separaon
Antenna “A”Antenna “B”
Router or Switch
Internet Source
PC
O From the “B” Side PC, try to access a known web-site via the Internet.
O If able to access the Internet, then the Antenna System is funconing properly.
O Go to page 4 and follow the shut-down procedure.
O If unable to access the Internet, please contact Technical Support for assistance.
support@tyconsystems.com

Tycon Systems 14641 S 800 W Bludale UT 84065 tyconsystems.com Page 4
EZ-Bridge® - LT2 Series
Shut-down Procedure
You are now ready to power down your systems and prepare them for
placement in their nal desnaons.
O Go to each wall-pack PoE injector and unplug from the wall outlet.
O You may now disengage the CAT5/6 jumper cables.
O You are now ready to install the Antennae and cabling.
—— Be sure to observe all of the warnings and safety precauons in the User Manual ——
O Go to the installaon secon of the User Manual and follow the
steps for mounng the Antennae.
Table of contents
Popular Antenna manuals by other brands

Emerson
Emerson 781S quick start guide

Duratrax
Duratrax DTXP3110 instructions

Glomex
Glomex DANUBE NEO R500N User and installation manual

COBHAM
COBHAM EXPLORER 3075GX User & installation manual

Directive Systems & Engineering
Directive Systems & Engineering DSE2424LYRMK quick start guide

Hughes Network
Hughes Network Spaceway Quick start setup guide