Tyent Hybrid User manual

www.tyentusa.com
MADE IN KOREA
The user is responsible for improper use of the
products such as use in any manner for which
the product was not originally intended and any
damage that may occur from such improper use.
This product is subject to changes that enhance
its performance without prior notification.
pH Chart
4.02.5 11.5
How to Measure pH: Place approximately 2 table-
spoons (30mL) of test water in a container and add
4 drops of pH reagent. Then, mix well and check the
color of the water with the pH chart above (The color of
the water will changeaccording to its pH.)
If the power cord is damaged, it must be replaced by the
manufacturer, or a similarly qualified Tyent repair person in
order to avoid a hazard.
This appliance is not intended for use by persons (including
children) with reduced physical sensory or mental capabili-
tiesor lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
applianceby a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
This product is intended for domestic use only.
Keep this User Manual handy for easy reference.
Carefully read this User Manual, particularly “all safety warnings.”
User Manual
W A T E R F O R W E L L N E S

23
Table of Contents
To Our Valued Customers
To Our Valued Customers
Table of Contents
Before Usage
Safety Precautions and Warnings
Product Features
Package Contents
Unit Overview
LCD Display and Touch Pad Overview
How to Install the Unit
Water Hose Installation
Directions for Product Use
System Setup Mode
Customer Serviceable Parts
How to Change the Filters
How to Reset the Filters
Cleaning Function
TURBO Function
Unit Specifications
Troubleshooting
Product Warranty
2
3
4
5
10
12
13
14
16
18
20
21
24
25
26
27
28
29
30
31
o Our Valued Customers
able of ContentsT
ntended UseI
Thank you for purchasing the
Hybrid Water Ionizer.
Please read all safety warnings and this User Manual carefully before using this
product to ensure proper product usage. (Keep the manual handy for easy
reference.)
This device creates
functional alkaline ionized and molecular Hydrogen
enriched water
. It changes the properties of regular tap water through the use of
electrolysis. Following are the changes normal tap water undergoes via this
process:
We are not responsible for any accidents and/or malfunctions due to the
improper use of this machine
Please keep the manual and warranty card in a safe place, so that it’s
easily accessible when you need it
Please refer to this manual often when you have questions when using or
when troubleshooting this unit
T
An increase or decrease in pH level
Creation of negatively charged hydrogen ions (antioxidants)
Purification through filtration
An increase in molecular hydrogen
To Our Valued Customers Table of Contents

45
Before Usage
Safety Precautions and Warnings
afety Precautions and WarningsS
Only use the unit with the correct voltage. Units sold in
the USA and Canada are designed to be used with
between 110 and 120 volts AC. Plugging your ionizer
into an outlet with a higher voltage than this will cause
serious damage to the ionizer.
efore UsageB
Safety precautions are provided for the safe and proper use of this unit and can prevent
danger, bodily harm and/or possible damage due to misuse. Please make sure you are
familiar with all the safety precautions and warnings associated with this unit.
Do not drink functional water with medication. When taking medication, use “clean H2O”
filtered water thirty minutes prior to taking medication as well as with medication.
You may resume drinking functional water thirty minutes after taking medication.
Always consult your primary care physician before drinking functional water. Only
drink a small amount near a neutral pH level for the first week. This will give the body
time to adjust to functional water during the detoxification period. See Welcome
Guide for full details on getting started.
If you notice any negative effects from drinking functional water, stop drinking the
functional water immediately and consult your primary care physician about
changes in your body’s pH level.
If you are currently under the care of a primary care physician for an existing condi-
tion, consult your primary care physician about how changes in pH and other
characteristics of functional water could affect your medical condition.
If you suffer from gastric anacidity, kidney failure or potassium excretion, you should
not drink functional water.
Verify the pH levels of the functional water dispensed from this unit on a monthly
basis to ensure proper function. This can be done with the supplied reagent drops
and a pH color chart.
When switching from one pH to another, it is good practice to let the water run for
several seconds before using.
It is common to drink half your body weight in ounces. For example, if you weigh 180
pounds, it may be wise to drink 90 ounces every day of water per day. This especially
applies after you have given your body some time to adjust to the new pH level.
The recommended drinking level for functional water is 9.5 pH (+-0.3). It is not
recommended to drink functional water above a pH of 10.
If you wish to store functional water, use a glass or other nonleaching material with
an airtight lid and store it in the refrigerator. Functional water will begin to weaken
immediately and will lose most of its benefits after 3 days.
Never run hot water through this unit.
Never drink acidic or turbo water.
DANGER (Red Warning Sign)
indicates an imminent hazard that could result in serious injury
or death. If you see this sign, stop using this unit immediately.
WARNING (Orange Warning Sign)
indicates a potential hazard that could result in significant
bodily harm or damage to the unit. If you see this sign, stop the use of this unit.
ATTENTION (Yellow Warning Sign)
indicates a potential hazard that could result in minor
bodily harm or damage to the unit.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Before Usage Safety Precautions and Warnings
Regarding the Power Supply
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
Do not use if the power cord is damaged or in a
loose power outlet.
Do not pull the power cord. Never touch the
power cord or the power outlet with wet hands.
Do not forcibly bend, squeeze, damage or crush
the power cord under heavy objects.
Unplug the power cord during general maintenance,
repair and inspection and while replacing parts.
Do not use power surge protectors with this unit.
Use unit with its own dedicated power source.
To reduce the risk of electric shock, do not remove
the cover; there are no user-serviceable parts
inside. Refer servicing to qualified service personnel.
Removing the cover will void the warranty.

67
Safety Precautions and Warnings
Safety Precautions and Warnings
Safety Precautions and Warnings Safety Precautions and Warnings
Installation
Install the drain faucet with suction cup near
your sink and adjust the position of the drain
faucet’s metal spout to drain into the sink.
Do not place this unit near heat sources.
Do not place this unit on an uneven surface.
Do not drop or use excessive force on this unit.
Do not connect the water line to a hot water supply.
Please use a new hose to connect with water line.
(Do not reuse old hose as it can cause leakage.)
Do not use unfit raw water in accordance with the
standards of the water service act.
Do not use in areas of high humidity and/or high
temperature.
new hose
Storage
If the original packaging is not available,
cover the unit in plastic to avoid scratching.
Store the unit in its original packaging in a
cool, dry place when not in use.
Carefully remove this unit from its packaging.
Keep the original packaging for future storage
and unit transportation.
Remove the filters and turn them upside
down to remove excess water before storing.
Make sure the drain faucet is positioned lower
than the unit.
Do not run the water for longer than 1 hour.
If the unit is not used for a few days, let the
water run for 1-2 minutes before drinking
functional water.
If using groundwater, make sure the water meets drinking water compliance
standards before installation. If not, a pre-filter may be required. (source
water quality greatly affects pH values and filter performance)
Do NOT use excessively hard water or saltwater. (may cause malfunctions
and/or shorten the product life)
Use only source water approved as drinking water by
an authorized organization (i.e. tap water).

89
Safety Precautions and Warnings
Safety Precautions and Warnings
Turn off
Turn off
Safety Precautions and Warnings Safety Precautions and Warnings
Do not place any objects on top of this unit no
matter how small they are.
Do not use or store pH reagents near flame.
(There is a risk of fire)
If water leaks out of the unit (other than the
hoses) or if the unit is standing in a puddle of
water, shut off the water supply, unplug the
power cord and contact qualified service
personnel for service.
Do not poke or scratch the touch pad or
LCD display with sharp objects.
Usage
If the unit won't be used for a long time, shut off
the valve and unplug the power cord.
If you hear strange noises, smell a burning odor
or see smoke, unplug the power cord immedi-
ately and call qualified personnel for service.
Replace filters every 6 months to optimize the
purification performance of this unit even if the
replacement indicator light isn’t turned on.
Cleaning
Do not store the unit near chemicals, food,
metals or medication
Do not spray water on the main unit. Do not
clean the unit with benzene or other chemi-
cals, which may leak into the unit. If using a
damp cloth, be very careful not to get
electronic display wet.
Please clean inside and outside of the outlet
tube with a soft brush. If you do not clean it
regularly, scale, such as lime components
(Calcium and Magnesium) may occur.
In areas with high TDS of water, calcium can
collect on the tip of the outlet tube. Please
keep it clean.
In areas of hard water (calcium scaling
present on faucets), notify your service
provider and install a cell safe antiscale
prefilter to protect the ionizer from scaling.
Do not use alkaline or acidic water in fish
bowls or aquariums. The sudden change in pH
could be harmful or fatal to some marine life.
It is beneficial for the maintenance of the
machine to run a strong acidic level for
5-minute cycles twice weekly. This will help
to maintain a clean chamber.
It is normal for condensation to be present
on the unit during humid summer months. If
condensation persists despite weather
conditions, unplug the power cord and refer
servicing to qualified service personnel.

10 11
Product Features
Product Features
roduct FeaturesP
Fully automatic system with embedded central
processing unit (CPU)
Every aspect of creating functional water is controlled by the CPU
chip that automatically finds an optimal operating condition when
in use.
For your convenience, the ionizer has the ability to dispense a
predetermined amount of water and then stop. Presets include
0.5L, 1.0L & 1.5L. These presets can be further adjusted with the
jog dial.
Fixed quantity discharge function
This unit is capable of producing 3 levels of alkaline drinking
water, 2 levels of acidic water, neutral clean water, turbo alkalin-
ewater and acidic waters for cleaning and neutral hydrogen
enriched water.
Production of 9 Different Kinds of Water
Powered by SMPS Plus Power Supply System
SMPS Plus®Power Supply System provides the maximumout-
put needed to produce highly stable electric power requiredfor
each phase of electrolysis. SMPS Plus is engineeredspecifically
for adjustability and variable voltage, which allowsthe unit to be
customized for your unique source water.
Twin Cell Hybrid
World's first electrolytic twin cell with new features and designs.
Enjoy maximum levels of molecular hydrogen at any alkaline level.
Automatic water flow
Simply pressing the touch button allows you to start and stop
the flow of functional water.
Automatic Stop Function
In order to prevent the overflow of water due to user negligence,
the water discharge is automatically stopped after 15 minutes of use.
※TURBO : 5 minutes
Eco mode
The LCD backlight will be turned off automatically during periods
of non-use and the Time function is displayed.
Excellent Sound Quality with Guided Support
Top-quality voice guidance system ensures that you are always
informed about what your ionizer is doing.
Filter replacement cycle
This unit features a filter life cycle display and voiceannounce-
ments designed to let you know when it is timeto change the
filters. Every 6 months is best for optimalperformance.
Touch LCD display color backlight
The color back light on the LCD display allows you to distinguish
alkali water from acidic water.
Advanced water purification system
Perfect, seamless elimination of foreign substances including
residual chlorine, organic & inorganic compounds through a
filtering process using Activated Carbon and UF micro-Ceramic
materials, enhancing the alkali water quality.
Filter Door Detection
When door is open, the water supply will be suspended for your safety.
15min
The outflow of functional water stops automatically when raw water is not
supplied, preventing the electrolytic cell and power supply unit from being
damaged due to current overflow, water from being wasted and accidental
water leaks. This function also allows you to set pH and ORP levels according
to the amount of water inflow, to distinguish pH from backlight colors and set
the auto cleaning function.
Product Features Product Features
Safety Functions

12 13
Unit Overview
Package Contents
ackage ContentsPnit OverviewU
Make sure you are familiar with the parts and features of this unit, and carefully read
the user manual and other important information
Water Ionizer
Front View
Water Outlet Unit
LCD Display
Front Cover
Door Case
Front Case
Water Outlet Tube
Jog Dial Control With Molecular
Hydrogen Water (H2Water)
Button
①
②
③
④
⑤
⑥
⑦
①
②
③
①
②
Rear View
Hanging Groove
Rear Case
Power Cord
Bottom View
Water Inflow
Water Outflow
1
5
64
7
2
12
3
2
3
1
Tools You Will Need
Adjustable WrenchUtility Scissors Plumber’s Tape
Water Outlet Tube
Faucet Diverter
pH Testing
Solution Bottle
8.2 ft (2.5 m)
of Hose
Assortment of Connectors
and Rubber Washers
Wrench
Drain Faucet
and Tube Suction Cup
Stem Elbow
Tube Suction Cup
2 ft (0.61m)
of Gray Hose with
Attached Tube Elbow
User Manual
Package Contents Unit Overview

14 15
LCD Display and Touch Pad Overview
LCD Display and Touch Pad Overview
CD Display and Touch Pad OverviewL
Standby screen1
Water Outflow screen2
Display color3
ⓐ ⓑ
ⓒ ⓓ
ⓔ ⓕ ⓖ
ⓗ
ⓚ
ⓘ ⓙ
ⓝ
ⓞ ⓟ ⓠ
ⓡ ⓢ
ⓣ
ⓛ
ⓜ
ⓐ The outflow button of the selected level will flash.
ⓑ The following information is displayed in order.
pH indication of selected level
Indication of the current amount of flow
Indication of the remaining time of flow
※The pH value of each level is the standard value based on the test water.
※Depending on the quality of the raw water used, the flow rate, the water
temperature, etc., the actual number of functional water may be different.
Backlight of LCD display will match the pH level color according to water
pH level being used after icon is pressed.
Alkaline level 1 Alkaline level 2 Alkaline level 3 H2 water
Purified water Acidic level 1 Acidic level 2
※Do not Drink ※Do not Drink ※Do not Drink
Turbo
The backlight color of all outflow levels light up by response color of
standard colorimetric paper. By using the backlight color, the level is
distinguished and prevents drinking Acidic water.
H
2
water
Alkaline level 1
Alkaline level 2
Alkaline level 3
(Hydrogen Alkaline)
(Hydrogen Alkaline)
(Hydrogen Alkaline)
ⓐ
ⓑ
ⓒ
ⓚ
ⓛ
ⓜ
ⓝ
ⓞ
ⓟ
ⓠ
ⓡ
ⓢ
Time/pH/Flow
Remaining time
Fixed quantity discharge
Door open
System set up
Cleaning
Voice on/off
1st filter indicator and reset
2nd filter indicator and reset
Jog Dial Control With
Molecular Hydrogen Water
(H2Water) Button
ⓐ
ⓑ
LCD Display and Touch Pad Overview LCD Display LCD Display and Touch Pad Overview LCD Display
ⓣ
Turbo
Purified water
Acidic level 1
Acidic level 2
AM/PM
pH indicator
Flow indicator
ⓓ
ⓔ
ⓕ
ⓖ
ⓗ
ⓘ
ⓙ
(Hydrogen Alkaline) (Hydrogen Alkaline) (Hydrogen Alkaline)

16 17
How to Install the Unit
How to Install the Unit
ow to Install the UnitH
Determine whether you will connect the unit directly to the cold water supply line
(under sink) or to the faucet (see image).
Do not turn on the main water supply until all hoses are properly installed to the
unit. The unit and components are subject to change without prior notification in
order to enhance performance.
Many faucets vary in design, and your faucet may require different setup instructions
than those featured in this manual. Please consult a qualified service professional if you
are unable to correctly complete the installation.
Shut off both the hot and cold water main supply at the pipe under the sink.
If your faucet features a screw-on style aerator, remove it by unscrewing it from
the tip of the faucet.
If the included faucet diverter does not fit directly to the tip of the faucet, select
an appropriate size connector and rubber washer (included).
When connecting the diverter or adapter to the faucet, be sure to use plumbing
pipe thread seal tape also known as plumber’s tape or teflon tape (not included)
to prevent leaks.
If necessary, connect the faucet diverter with the appropriate connector to the faucet.
Be sure all connections are secure but do not overtighten them.
Option A l Faucet: A faucet connection requires a faucet diverter (included).
Option B l Under-Sink: An under sink connection requires an under-sink adapter kit
(not included) or a compatible t-valve (available from most hardware stores). For more
information see Welcome Guide or call support.
Option A – Faucet Installation
①
②
③
④
⑤
⑥
①
②
③
④
⑤
⑥
⑦
Option B – Under-Sink Installation
Both Options
Purchase either an under-sink installation kit (not included) or purchase a
T-connection (with shut-off valve) from a hardware or plumbing supply store.
Shut off both the hot and the cold water main supply at the pipe under the sink.
Locate the cold water supply line valve.
Disconnect the faucet cold water supply line from the main cold water pipe. Use
a towel to catch the small amount of water that may come from the faucet supply line.
When connecting the T-connection to the cold water pipe, be sure to use
plumber’s tape or teflon tape (not included) to prevent leaks.
Reconnect the faucet’s cold water supply line to the T-connection (now secured
to the main cold water pipe).
Be sure all connections are secure but do not overtighten them.
How to Install the Unit How to Install the Unit

18 19
Water Hose Installation
Water Hose Installation
ater Hose InstallationW
Inflow Drain
①
Place the unit on the planned installation location
and screw the flexible tube clockwise into the
water outlet hole positioned at the top of the unit.
Do not over tighten.
②
③
Measure between the unit’s location (on the counter)
and the water faucet (or under-sink T-connection)
where the diverter (or T-connection) will be installed.
Cut enough hose to allow an easy connection from
the rear of the unit to the water supply (either using
the faucet diverter or the under-sink T-connection).
Note: Keep the length from the unit to the faucet
under 16 feet (5 meters). You may need a pressure
pump or a larger size hose if the pressure is too low.
Be sure to leave a few extra inches (centimeters) of
length so the faucet can still be rotated.
Press the stem elbows into the water inflow and
outflow holes on the bottom of the unit until you
hear a click and feel the hose sit firmly in place.
①
②
③
How to Install the Drain Faucet
Connect the drain hose tube elbow to the outflow
hole located at the bottom of the unit.
Connect the drain hose to the tube suction cup and
secure it so that it does not move.
Connect the drain hose to the faucet and secure it
to the proper position on the sink.
④
Connect the hose from the inflow hole to the cold
water supply either at the faucet diverter using
Option A, or the under-sink T-connection using
Option B.
Option A: Remove the nut from the diverter, slide
the nut onto the hose, then firmly seat the hose on
the faucet diverter and screw the nut over the
hose and back onto the faucet diverter.
Option B: Route the hose through the countertop
to the T-connection, then firmly seat the hose on
the T-connection and make sure the connection
is sealed completely.
⑤
Make sure all hose connections are firmly seated
in the correct holes, both on the unit and at the
water supply
⑥
Turn on both the cold and hot water supply. Make
sure there are no leaks at any of the connections.
Make sure the faucet is working with both hot and
cold water. Make sure there are no leaks from the
hose connections on the bottom of the unit. Make
sure the hoses are firmly seated in the unit holes.
⑦
Plug in the power cord. You should hear a series
of tones when you power up the unit.
Inflow
hose to faucet
Water Hose Installation Water Hose Installation

20 21
system setup mode
Directions for Product Use
irections for Product UseD
ystem setup modeS
How to Select Alkaline Water from the Unit
How to Select Hydrogen Water from the Unit
1
2
How to Set up the Quantity Discharge Function
3
※ When you press the Alkaline level 3 button, the water that comes out is both alkaline
AND hydrogen enriched.
※ If the selected button is not pressed again, the unit will automatically stop after
15 minutes of water outflow.
》 》
Press the Hydrogen water button at the bottom of the unit.
Hydrogen water will begin to pour from the metal flex hose at the top of the unit.
Press the button again to stop the outflow of water.
①
②
③
For initial setup, press the QTY, C icon and choose the fixed amount of water quantity.
(0.5L →1.0L →1.5L →release).
When initial setup is complete, press the water outflow button.
The water outflow will stop automatically once the fixed amount of water quantity
is discharged.
》 》
》 》
H
2
water H
2
water
Enter the system setting mode by pressing the SET button
on the LCD for 3 seconds. (Beep twice notifications)
※Voice message : “System setup mode.”
pH level adjustment1
③
①
Use the F1(-) and F2(+) button to adjust the level.
※ F1 : Decrease / F2 : Increase
(Adjustable by Jog dial)
②Press the desired water level button for 3 seconds to enter
the pH setting mode of the selected level. (beep twice)
④Press the SET button for 3 seconds to complete the setting
and return to the stand by screen. (Beep twice notifications)
※Voice message : “Setup was completed.”
Press the desired icon on the LCD screen.
The selected icon will flash during water outflow.
If you press the selected icon that’s flashing, then the water outflow will stop.
※If the selected icon is not pressed again, the unit will automatically stop after
15 minutes of water outflow. (Turbo: 5 minutes)
①
②
③
①
②
③
Directions for Product Use System Setup Mode
How to Set up the Quantity Discharge Function(Jog Dial)
4
Touch the "QTY.C" button and select the quantity amount you'd like to modify
(0.5L, 1.0L, or 1.5L)
You can fine tune the exact amount of water you need by turning the jog dial.
- Clockwise : Increasing by 0.1L ( Max. 5.0L )
- Counterclockwise : Decreasing by 0.1L ( Min. 0.2L)
Push the Alkaline or Acidic level of water you desire.
Water outflow will automatically stop after dispensing the fixed amount of water
you selected. (Discharge of water will stop when you touch the button while water
is coming out.)
After water comes out, fixed quantity discharge function is released.
①
②
③
④
⑤
》 》
H
2
water

22 23
system setup mode
system setup mode
The voice will be turned on/off by press the voice button.
Voice message
- On : “ Voice function works ”
- Off : “ Voice function terminates ”
①
②
5Selecting Voice On/Off
6ECO mode
④
③Control the voice volume by F1(-) and F2(+) button.
※ F1 : Decrease / F2 : Increase
(Adjustable by Jog dial)
①
②
Enter the system setting mode by pressing the SET button
on the LCD for 3 seconds. (Beep twice notifications)
※Voice message : “System setup mode.”
4Volume Level Adjustment
①
②Press the Voice button to set the volume.
Voice On
Voice Off
If the product does not operate for 10 minutes,
it will switch to ECO mode. The display turns
off automatically and switches to the clock
mode.
Touch the control panel to turn the display
back on. At this time, the display screen is
displayed as the information of the last level of
outflow.
Press the SET button for 3 seconds to complete the setting
and return to the stand by screen. (Beep twice notifications)
※Voice message : “Setup was completed.”
Press the SET button for 3 seconds to complete the setting
and return to the stand by screen. (Beep twice notifications)
※Voice message : “Setup was completed.”
How to set the time3
①Enter the system setting mode by pressing the SET button
on the LCD for 3 seconds. (Beep twice notifications)
※Voice message : “System setup mode.”
②Enter the the time setting mode by pressing the QTY,C button
for 3 seconds. (Beep twice notifications)
③Each time you press the QTY.C button, the adjustment
position changes to AM/PM-Hour-Minute.
④Setup the time by F1(-) and F2(+) button.
※ F1 : Decrease / F2 : Increase
(Adjustable by Jog dial)
⑤
System Setup Mode System Setup Mode
How to select language2
Enter the system setting mode by pressing the SET button
on the LCD for 3 seconds. (Beep twice notifications)
※Voice message : “System setup mode.”
①
④Press the SET button for 3 seconds to complete the setting
and return to the stand by screen. (Beep twice notifications)
※Voice message : “Setup was completed.”
②Enter the the language setting mode by pressing the Voice
button for 3 seconds. (Beep twice)
③The display shows the language currently set in the code.
Use the F1(-) and F2(+) button to adjust(Adjustable by Jog
dial) the language and to select the desired language. (When
you select a language, you will be announced by the
selected language)

24 25
how to change the filters
Customer Serviceable Parts
ow to Change the FiltersH
Close
Open
1.
Shut off the water supply to the unit and
unplug the power cord. Open the door in
front of the product.
2.
3.
4.
5.
Remove old filter:
ⓐLift the filter that needs to be replaced.
ⓑTurn the filter counterclockwise until it
loosens.
ⓒPull the filter down and remove it.
Put the new filter into the right position by
turning it clockwise.
When installing the filter, the connection
bump of the head and the connection
groove on the top of the filter should be
completely combined.
Close the door, plug the power cord
back in and reengage the water supply.
ⓐ
ⓑ
ⓒ
After initializing the filter, press the H2O button and run purified water for
3 minutes. It is highly recommended that you follow this process in order
to ensure that your machine functions properly.
Customer Serviceable Parts How to Change the Filters
ustomer Serviceable PartsC
Primary Filter: YT20 1st Filter
1st Filter
2nd Filter
ATTENTION: If do not use the TYENT original filter or parts for replacement, it will
cause product malfunction and we cannot provide warranty.
The life of the filter can vary greatly due to use, water pressure, water quality and the
changing of the seasons. Filters may need to be replaced sooner than the scheduled
time due to these reasons, you may notice reduced water quality or declining water taste.
Recommended filter replacement cycle:
(Every 6 months)
Removes harmful chemicals like chlorine,
compounds such as agrichemicals and
detergents, large suspended matters like rust
and sediments as well as other volatile organic
compounds through an efficient activated
absorption method. It also eliminates bad
smells and any remaining dissolved chlorine.
Secondary Filter: YT20 2nd Filter
Recommended filter replacement cycle:
(Every 6 months)
0.01 micrometer filtering film filters contaminated
materials including ordinary bacteria, etc. and
maintains the minerals in the water.
*If you do not use TYENT original filters, the following problems will occur.
- Cannot provide product warranty.
- It may cause product malfunction.
- The life of the product is shortened.
- It may cause product leakage.
- Filter performance is significantly reduced.

26 27
Cleaning Function
How to reset the filters
ow to Reset the FiltersH
Press the F1 or F2 filter icon for 3 seconds in order to reset the filters usage
percentage back to 00%.
※When you press and hold the F1 or F2 icon the unit will beep twice followed
by a voice announcement.
※Voice message: “1st or 2nd Filter / initializing was performed”
When initialized normally, the corresponding filter usage on the display is
displayed as 0%.
①
②
※If you do not initialize the filter after replacing the filter, the corresponding filter
change message will continue to operate.
※After initializing the new filter/Reset the filter, press the H2O button and run
purified water for 3minutes.
leaning FunctionC
The cleaning function is performed after every 30ℓof water is dispensed. Water
outflows through the Drain Faucet only, and it will stop automatically when the washing
time is done.
(Note: RTR icon and backlight will flicker before the automatic cleaning is performed)
※Automatic cleaning will be performed after 1ℓof water is dispensed, and when you
power up the unit.
To keep the side of the electrolytic cell clean, a cleaning
function will be performed.
1
The cleaning function is performed after using Acidic water or Turbo water.
Water outflows through the Water Outlet Tube and the Drain Faucet, and it will
stop automatically when the washing time is done. (Note: RTR icon will flicker
and the backlight will turn RED during the automatic cleaning cycle after the
use of Acidic water or Turbo water).
※Voice message: “It’s under washing, do not drink”
Cleaning performed after using Acidic water or Turbo water2
The cleaning function is performed before using Purified water. Water outflows
through the Drain Faucet only. Purified water will come out automatically after
the cleaning is performed. (Note: After using acidic water or turbo water, the
cleaning is not performed since it has already been cleaned, as explained in
number ②).
Cleaning performed before using Purified Water3
For adjusting the pH value, cleaning is performed when switched from Alkaline
water to Hydrogen water without stopping outflow. Water outflows through the
Drain Faucet only. Hydrogen water will come out automatically after cleaning.
Cleaning performed when non-stop switched from
Alkaline water to Hydrogen water
4
For Keeping side of electrolytic cell clean, cleaning function performed in the following condition.
How to Reset the Filters Cleaning Function

28 29
Unit specifications
Turbo function
urbo FunctionTnit specificationsU
The TURBO function allows you to create strong alkaline and strong acidicwater.
These types of waters are ONLY to be used for cleaning, sanitizing, and disinfecting
purposes. NEVER DRINK THESE TYPES OF WATER.
TURBO
Strong Acidic Water
pH 3.0
~ pH 4.0
Used to Disinfect
and Sterilize
TURBO
Strong Alkaline Water
pH 10.0
~ pH 11.0
To remove stains from
fabrics/carpet/upholstery.
Alkaline Turbo Water Outflow Acidic Turbo Water Outflow
※To make the best functionality, there may be some change without notices.
YT22-HA6
Max 120W
O
Alkaline Electroylzercell 1set, Hydrogen Electroylzercell 1set
Water Cell Plate
Materials
Hybrid Water Ionizer
100 -130 V~ , 200 -240 V~ / 50-60 Hz
4 -35ºC ( 39 - 95ºF )
0.1- 0.5 MPa
User adjustable pH level control
Dual .01 Micron Filtration System
LCD filter replacement and announcement
Platinum and Titanium
W300 x D135 x H355 mm (11.8 x 5.3 x 13.9 inches)
approx 5.5kg (12.1 Lbs )
Product Name
Rated Voltage
Electrolytic Cell
Quantity of Poles
Power
Consumption
Operating
Pressure Range
Available
temperature
Model Number
TURBO Function
v
The waters produced in
TURBO
mode are not intended for drinking.
DO NOT DRINK
these types of waters.
●
DO NOT
Use the
TURBO
function in a manner other than directed.
●
While operating the TURBO function, the machine will automatically
stop dispensing water after 5 minutes. This feature prevents accidental
overflow or flooding.
●
Turbo Function Unit Specifications
2 Alkaline, 1 Hydrogen-Alkaline, 1 Neutral, 2 Acidic, 1 Hydrogen,
Turbo Alkaline and Turbo Acid
Adjustable pH
Filters Confihuration
Filter Life Display
Product Size
Product Weight
pH Levels

roubleshootingT
Symptoms
Abnormal Taste
Checkpoints Measures to be Taken
Check period of use Run the unit for one minute, draining
stagnant water
been reset
Settlement in
extracted water
Check for excessive calcium in the
source water
Check if non-operating time exceeds
10 minutes.
When non-using the unit for 10 minutes,
it changes to the ECO mode automatically.
The unit returns to normal after touching
the screen.
Incorrect pH levels
Check TDS of water Water quality varies by region
Reduce the amount of raw water
Contact us. Request after-sales service
Check whether the amount of drained
water is small
Unit stops during use
Unit stops automatically after 15 minutes
(*Turbo function: 5 minutes)
Check whether the operating time exceeds
15 minutes (*Turbo function: 5 minutes)
Check whether the hose is bent or folded
(less than 1ℓ/ min)
or whether the water supply line is frozen
Check whether the valve on the water
supply is closed
Open the Valve
Stretch out the hose
Contact us to install a water pump
Wait until water comes out of the water
supply pipe
Contact us to install a pressure
-reducing valve
(5 kgf/㎠or faster)
Unit leaks
Check other areas of the unit
Unplug unit Contact us
Check that pH is not higher than 10pH Calibrate pH
1.
2.
r
Product Warranty
Toll Free: 855-TYENT-US
Tyent USA, LLC
www.tyentusa.com
The screen turns o.
Water Outow Change
Only puried water is
extracted.
Filter replacement icon
remains“on”even after lter
has been replaced
30 31
Product warranty
Troubleshootingn
Product Name
Customer’s Name/Phone
Customer’s Address
Date of Purchase
Installation Date/Name
Preduct Model Warranty Period
Hybrid Water Ionizer □YT22-HA6
v
Lifetime
(Above conditions apply)
Troubleshooting Product Warranty
This product features a lifetime warranty. If any manufacturing defects
or spontaneous failures occur during the warranty period, the unit will
be repaired or replaced at no charge.
3.
4.
5.
In case of a failure resulting from the customer’s negligence or intentional
damage of the product, the customer shall be responsible for repair or
replacement costs. The use of unapproved lters that are manufac-
tured by a 3rd party will void the warranty.
If any failure occurs, please call the service center. Note: The answers to
many service questions can be found online at tyentusa.com/support.
This warranty is non-transferable and valid only for the original owner.
Keep this document in a safe place as it is your Authentic Lifetime
Warranty. This certicate extends the terms of the standard warranty,
and ensures that your ionizer is guaranteed for life.
This manual suits for next models
1
Table of contents
Popular Water Dispenser manuals by other brands

Follett
Follett Chewblet 7 Series installation guide

Follett
Follett C/E25CI425A Installation, operation and service manual

US Water Systems
US Water Systems 076-AQT-075 owner's manual

Pontec
Pontec Multi Clear Set 5000 operating instructions

PoolRite
PoolRite CL50 Installation and operation manual

Everpure
Everpure EC110 Specification sheet

Culligan
Culligan CTM Series Installation, Operation, and Service Instructions with Parts Lists

BWT
BWT WS255 Fitting and operating instructions

Spartus
Spartus WRC310 user manual

BWT
BWT Rondomat Duo-DVGW 2 Installation and operating manual

Kemper
Kemper KHS CoolFlow Maintenance instructions

Oasis
Oasis Mirage instruction manual