Uconnect BLE-232B User manual

BLE RS-232 adapter user manual V1.1 2017.06.07
1
Bluet
tt
tooth V4.1
11
1BLE
RS-232 Serial Adapter
Model: BLE-232B
1. Package content:
BLE RS-232 adapter
White Box Dimension: 11 x 6 x 5 (cm)
Total Package Weight: 105 g
Package Contents:
BLE RS-232 adapter x 1
Screw x2, Screw nut x 2
A4 User manual x 1
Mini USB Cable x 1
2. Profile:
2.1 Top view:
LED Status Description
Data LED
flash
Data transmission
Data LED solid on
No data transmission
Link LED solid on BLE Link
Link LED flash
No Link
Data & Link LED solid on
DFU/OTA Mode
DB9 (Female)
Mini USB (Power)
▲
▲▲
▲
+
(5~27 VDC)
▼GND
Reset to Default
LED:
Link: Blue
PWR/Data: Red

BLE RS-232 adapter user manual V1.1 2017.06.07
2
2.2 DB9 connector:
There’re 2 screws and 2 nuts inside the package, the screw or nut are available.
2.3 Rear Side:
Switch configuration:
Setup CTS/RTS Stop Bit
Parity Role Baud Rate
9 8 7 6-5 4 3-2-1
0: Switch
1: Command
0: Disable
1: Enable
0: 1
1: 2
00: None
01: Odd
10: Odd
11: Even
0:Slave
1:Master
110:2400
111:4800
000:9600
001:19200
010:38400
011:57600
100:115200
101:230400
Remark:
1. 000000000 by default, in red bold character
2. The GATT service and AT command will support more settings than the DIP switch,
please check the page 4 section 5 and page 5 section 6.
DIP Switch
▲DCE
▼DTE
Screw
Nut
Nut
Screw

BLE RS-232 adapter user manual V1.1 2017.06.07
3
2.4 RS232 Interface (Female)
Pin
Signal
DTE Direction
DCE Direction Description
1 N/A
2 TxD Output Input Transmitted data
3 RxD Input Output Received data
4 N/A
5 GND Ground
6 N/A
7 CTS Input Output Clear to send
8 RTS Output Input Request to send (Default)
9 VCC Power Input (5~27 VDC)
3. Power supply:
3.1 Voltage: 5~27 VDC, Don’t exceed the limit.
3.2 There’re 3 ways to power the adapter: Mini USB, Terminal Block and pin9 of DB9,
please choose one. Don’t power the adapter by more than two sources.
3.3 The mini USB cable is inside the standard package.
4. Specifications:
4.1 Default value:
Baud rate: 9,600 bps
Data bit: 8
Parity: none
Stop bit: 1
Flow control: none
Device Name: BLE 232
4.2 All function of COM port:
Baud Rate: 1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4/460.8/921.6 Kbps
Parity: none/even/odd
Stop bit: 1/1.5/2
Data bit: 7/8
Remark: The GATT service and AT command will support all the functions, please
check the page 4 section 5 and page 5 section 6.
4.3 Range: max. 50 m in open space
4.4 TX Power: Max. 3 dBm
4.5 RX Sensitivity: -89 dBm typical
4.6 TX current consumption of 15.6 mA (radio only, 0 dbm)

BLE RS-232 adapter user manual V1.1 2017.06.07
4
4.7 Operation Temperature: –40 °C to +70 °C
4.8 Dimensions: 81.6 mm (L) x 31.75 mm (W) x 17 mm (H)
4.9 Antenna Gain: max. 2 dB
Remark: All contents are subject to change without notice.
5. GATT Service:
5.1 Architecture:
5.2 Programming Interfaces:
GATT
UUID
UUID_Device Information 0000180A-0000-1000-8000-00805F9B34FB
UUID_Firmware Revision String 00002A26-0000-1000-8000-00805F9B34FB
UUID_NOTIFY (~20 bytes) 00031234-0000-1000-8000-00805F9B0130
UUID_RxData (~20 bytes) 00031234-0000-1000-8000-00805F9B0131
UUID_MacID (6 bytes) 00031234-0000-1000-8000-00805F9B0133
UUID_DeviceName (15 bytes) 00031234-0000-1000-8000-00805F9B0134
UUID_Reboot (1 bytes) 00031234-0000-1000-8000-00805F9B0135
UUID_PinID_Setting (6 bytes) 00031234-0000-1000-8000-00805F9B0136
Device nformation
Firmware Revision String
NOT FY
RxData
BLE_CONF
Mac D
DeviceName
DeviceName
Pin D_Setting
Serial BLE Service
SetCharacteristicNotification(Char)
SetCharacteristicNotification
(Char)
SetCharacteristicNotification(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
Mobile APP
SER AL

BLE RS-232 adapter user manual V1.1 2017.06.07
5
UUID_BLE_CONF (7 bytes) 00031234-0000-1000-8000-00805F9B0132
Byte0 Byte1
Byte2
Byte3
Data bit Hwfc Stop Bit Parity Bit
7,8 0x01:on
0x00:off
2:1
3:1.5
4:2
0x02 : No Parity
0x01 : Odd Parity
0x00 : Even Parity
Byte4
Byte5
Byte6
Baud Rate Device Mode Reset To Default
00:9600
01:19200
02:38400
03:57600
04:115200
05:230400
06:2400
07:4800
08:1200
09:460800
10:921600
0x01:on
0x00:off
0x01: Reset
6. Command set via COM port:
Command Value Description
AT Check the connection status between control terminal and the RS-232
adapter. Response: “OK” when the connection is ok. Response:
“ERROR” when the connection is not ok.
AT Test the RS-232 status when first connect the adapter with the controller.
(Default) N The command will disable the auto link function.
? Inquire the current setting.
BAUD= This command is used to specify the baud rate of COM port.
The command will need 200 ms delay.
1200 1200 bps
2400 2400 bps
4800 4800 bps
9600 9600 bps
(Default) 19200 19200 bps
38400 38400 bps
57600 57600 bps
115200 115200 bps
230400 230400 bps
460800 460800 bps

BLE RS-232 adapter user manual V1.1 2017.06.07
6
921600 921600 bps
? Inquire the current baud rate.
BIT=
7 7 data bit
8 8 data bit
? Inquire the current data bit
DEFAULT= This command is used to restore the default settings and originate a
warm start.
Y Restore the default settings (e.g. 19200 bps).
The command will re-start the system for 1 second.
DFU= Device Firmware Upgrade via PC software. OTA (Over the air) is
available to upgrade the firmware by APP
Y
ECHO= This command is used to specify whether the adaptor echoes
characters received from the UART back to the DTE/DCE.
N Command characters received from the UART are not echoed back to
the DTE/DCE.
(Default) Y Command characters received from the UART are echoed back to the
DTE/DCE.
? Inquire the current setting.
FLOW= This command enable or disable flow control signals (CTS/RTS) of the
UART port. Note, the setting is not affected by DEFAULT.
The command will need 1 second delay.
(Default) N Disable flow control.
Y Enable flow control.
? Inquire the current setting
NAME= This command is used to specify a device name for the adaptor.
You can specify a friendly name using 0 to 9, A to Z, a to z, space and –,
which are all valid characters. Note that “first space or -, last space or –
isn’t permitted”. The default name is “Serial Adaptor”.
(Default) BLE232 Default device name
xx….xx “xx….xx” is a character string with the length from 2 to 30.
R Restore the default settings name=“BLE Serial”.
? Inquire the name of the local adaptor.
PARITY= This command is used to specify parity bit setting of COM port.
The command will need 200 ms delay.
(Default) N None parity bit
O Odd parity
E Even parity
? Inquire the current setting.
PROMPT= The command is used to decide whether result messages are prompted
when Setup commands are executed. The result messages are:
OK/ERROR for command execution.
(Default) Y Prompt result messages.
N Not prompt result messages.
? Inquire the current setting.
ROLE= This command is used to specify whether the adaptor is in the central or

BLE RS-232 adapter user manual V1.1 2017.06.07
7
peripheral role. If the device role is changed, the adaptor will reboot and
all paired addresses will be cleared.
C Set the adaptor to the central role.
(Default) P Set the adaptor to the peripheral role.
? Inquire the current role of the adaptor.
STATUS= Inquire all the current setting of the adapter.
T Inquire the inner temperature of the IC in centigrade
? Display the current setting of the adapter
STOP= This command is used to specify one or two stop bits of COM port.
The command will need 200ms delay.
(Default) 1 One stop bit.
2 Two stop bits.
? Inquire the current setting.
VERSION= This command is used to inquiry the firmware version.
? Inquire the version codes.
7. Central and Peripheral: (Similar like the Master and Slave roles)
7.1 DIP switch setting: The central will pair the slave automatically, please refer to page 2
section 2.3.
Switch DIP-9 to 0 (Switch)
Switch DIP-4 to 1 (Master)
The central will link with the neighboring peripheral automatically. The blue LED
will be solid on. The central will link with the paired peripheral on next time when
power on.
Please reset to the default and follow the above procedures if you want to link
with other BLE devices.
7.2 AT command: Please refer to page 5 section 6.
Set “role=c” or “ROLE=C” in one adapter.
The central will link with the neighboring peripheral automatically. The blue LED
will be solid on. The central will link with the paired peripheral on next time when
power on.
Please reset to the default and follow the above procedures if you want to link
with other BLE devices.
7.3 APP setup: Please contact the supplier to for the test APP.
The APP will search the BLE and select one as the central.
Then select the other one as the peripheral and link.
The central will link with the neighboring peripheral automatically. The blue LED
will be solid on. The central will link with the paired peripheral on next time when
power on.
Please reset to the default and follow the above procedures if you want to link
with other BLE devices.

BLE RS-232 adapter user manual V1.1 2017.06.07
8
8. APP: The APP is used for the configuration and the data transmission test.
Scan and select one. Connect and configure Data transmission test.
Download:
Android: iOS:
Remark: Please contact the supplier for the APP download or the sample code.
Disconnect
TX area
RX area
Data mode
Clear data
and log
Device list
Select one
Scan BLE
Enable
Central
Setup
Reset
Default
Setup mode
Serial Port setting: Baud rate, Data
bit, Stop bit, Parity, flow control.