UEi C165 User manual

Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
1-800-547-5740 • Fax: (503) 643-6322
INSTRUCTION MANUAL
ENGLISH
C165
Residential/Commercial Combustion Analyzer

2
FUNCTIONS
FEATURES
• Flue temperature: 32° to 1112°F
• Inlet temperature: Internal/ External sensor 32° to 112°F
• O2:0 - 21%
• CO: 2000 ppm
• CO2: 0 - 20 %
• Efficiency: Nett/Gross 99.9%
• Efficiency: High (calculated) 119.9%
• Excess air: 250%
• CO/CO2ratio: 0.99%
• Differential pressure
TABLE OF CONTENTS
Functions.............................................2
Features..............................................2
General Specifications ................................3
Important Safety Warnings ............................3
Symbols..............................................4
Analyzer Overview ..................................4-5
Overview ...........................................6
Pre Test Checklist...................................7
Setting Inlet Temperature ...........................7
Analyzer Connections ...............................7
Emptying & Cleaning the In-Line Water Trap ........7
Changing The Particle Filter.........................7
Quick Start ..........................................7
Fresh Air Purge......................................8
CO Over-range Protection Pump .....................8
Measuring Flue Gases...............................8
Using The Menu ..................................9-11
Combustion Test.................................11-12
Combustion Test
- Optional Nitric Oxide Sensor .....................12
Commissioning Test ................................13
Heat Exchanger Integrity Test ......................13
Room CO Test ......................................13
Printing ............................................14
Printouts ...........................................14
iOS App Guide .....................................15
Kane Wireless Printer App Home iOS Screen ............15
Kane Wireless Printer App Home Screen ...............15
Android App Guide .................................16
Kane Wireless Printer App Home Android Screen ........16
Kane Wireless Printer App Android Settings Screen ......16
Kane Wireless Printer App Android Personal
Details Screen.....................................16
Temperature Testing ...............................17
Pressure/Temperature Testing......................17
Pressure Measurement Good Practice..............17
Large Bore Tubing Issues...........................17
Analyzer Specification ..........................18-19
Certification........................................19
Electromagnetic Compatibility......................19
Where To Test...................................20-21
What Results Are Generally Acceptable ............21
Powering Off .......................................22
Post Test ...........................................22
General Maintenance ..............................22
Cold Weather Precautions..........................22
Replacing The Batteries ............................23
Annual Recertification .............................23
Recertification Services............................24
Returning Your Analyzer............................24
Where To Send Your Analyzer ......................24
Other Important Factors Relating To Combustion ...25
Combustion Measurement Terms ...................25
Disposal............................................26
Storage.............................................26
End Of Life Disposal ................................26
Warranty ...........................................26
•
EOS Technology
•
Pre-programmed fuels:
Natural Gas, Propane, Butane, LPG,
Light Oils (28/35 sec), Woodpellets, Town Gas, Coke Gas, Biogas,
Biofuel
•
Memory Positions:
30
•
6 line backlit display
•
High altitude compensation
•
User customizable parameter views
•
Individual report printouts
•
Real-time clock

3
GENERAL SPECIFICATIONS
IMPORTANT SAFETY WARNINGS
Read entire Safety Notes section regarding potential hazard and proper instructions before using this analyzer. In this manual the
word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to
indicate conditions or actions that may damage this instrument.
WARNING
To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe
injury or death.
WARNING
• Do not use this analyzer during electrical storms or in wet weather.
• To avoid false readings, charge batteries if a low battery indicator appears.
• Always adhere to national and local safety codes. Use proper personal protective equipment (PPE)
WARNING
This analyzer extracts combustion gases that may be toxic in relatively low concentrations. These gases are exhausted from the back
of the analyzer.
This analyzer must only be used in well-ventilated locations by trained and competent persons after due consideration of all
potential hazards.
Users of portable gas detectors are recommended to conduct a “bump” check before relying on the unit to verify an atmosphere is free
from hazard. A ‘bump” test is a means of verifying that an instrument is working within acceptable limits by briefly exposing to a known
gas mixture formulated to change the output of all the sensors present.
NOTE: This is different from a calibration where the instrument is also exposed to a known gas mixture but is allowed to settle to a
steady figure and the reading adjusted to the stated gas concentration of the gas of the test gas.
• Operating Temperature: 32° to 112°F (0° to 45°C)
• Storage Temperature: 0° to 120°F (-18° to 50°C)
• Operating Humidity: 10% to 90% R.H.
• Back light: Yes
• Dimensions: 7.87 x 1.77 x 3.5 inch
• Item Weight: 1.35 lb
• Calibration: Recommended Annually
• Certification: CE Conformity, RoHS, REACH Compliant,
AHRI 1260 standard
• Battery Size: Alkaline or NiMH AA 3
• Accuracy: ± (% of reading + # of least significant digits)

4
ANALYZER OVERVIEW
A. Infrared Printer Port
B. On/ Off (Power) Button
C. 6 Line Backlit Display
• Press any button to turn Back light on (backlight duration can be set in Menu/Screen/Backlight)
D. Display Line Lights
E. Pump Toggle Button: short press is data hold, long press turns pump on and off
F. UP Button
• Short press to navigate “UP”
G. Wireless/Store/Print Button: short press print, long press store
H. Down Button: short press moves down, long press does a fresh air purge
I. ENTER Button: short press works as enter, long press turns on work light
J. Rotary Selector Dial
K. Particle Filter (inside water trap)
L. Water Trap
M. LED Water Trap Indication
N. Protective Rubber Boot with Magnets
O. Serial Number QR Code: (Serial Number viewable under Protective Boot)
P. Sensors Fitted: (label under Protective Boot) Sensors that can be fitted in unit when shipped (CO-H2, CO, CO2, NO, O2)
Q. Battery Compartment: (under Protective Boot)
R. Grip Indentation: Indentation for fingers to grip analyzer
S. Water Trap Drain Plug (Red plug; take caution NOT to damage plug when removing protective boot)
T. Battery Charge USB Adapter Connection
U. Temperature Connections
• Flue Probe Temperature: T1
• Inlet Temperature: T2
V. Flue Gas Inlet Connection
W. Pressure Connections
• Pressure: P1
• Differential Pressure: P2
X. Infrared Printer Port
SYMBOLS
Low Battery Degrees Fahrenheit
Degrees Celsius Menu
Pump Start Pump Stop
Navigate Down Navigate Up
Enter Key Wireless/Store/Print

5
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
ANALYZER OVERVIEW (CONT.)
A
Sensors
Fitted:
CO NO
CO-H
2CO
2O
2
Serial No.
UEiTEST INSTRUMENTS
www.ueitest.com
Tel: 1-800-547-5740
B
C
D
E
F
G
H
I
J
M
N
T
U
W
V
X
L
K
Q
S
R
P
O
T2 T1
P2 P1
[TOP]
[BOTTOM]
Narrow Pin MUST be on the
Right hand side.
Flue Probe Temperature Plug
(Plugs into T1)
Flue Probe
Gas Inlet Plug
Red Connector
(plugs into Flue
Gas Inlet)

6
The C165 Combustion Analyzer measures CO, CO2, differential temperature and differential pressure.
CO2is set to zero in fresh air automatically after the initial countdown.
It is important that re-zeroing is done in outside fresh air as indoor CO2levels are affected by human breath.
It calculates oxygen (O2), CO/CO2ratio, Losses, Combustion Efficiency (Gross, Nett, Gross Condensing, or Nett Condensing).
The C165 Combustion Analyzer can also measure CO levels in ambient air - useful when a CO Alarm is triggered. It can also perform a Room CO Test
for 30 minute duration.
A structured Commissioning Test has been included for the installation of boilers.
A low flow detection system warns of low flow and switches the pump off. This also helps to prevent water ingress from overfilled water traps.
The analyzer has a protective rubber boot with magnets for hands-free operation and is supplied with a probe with an integral temperature sensor.
A large 6 line display provides the user with relevant information. All data can be printed via the infrared printer or Wireless Printer App.
The C165 uses a new data storage system allowing the user to store the maximum number of logs of interest to them, rather than be restricted to an
allowance of particular logs.
The memory can store up to 30 logs of any combination of Combustion, AUX, Temperature, Heat Exchanger, Room CO, Commissioning tests.
OVERVIEW

7
PRE TEST CHECKLIST
SETTING INLET TEMPERATURE
ANALYZER CONNECTIONS
• Turn on and zero the analyzer, without the flue probe connected, to use ambient temperature
• Connect the flue probe thermocouple to T1 during zero countdown use for inlet ducted system
• Connect a thermocouple to T2 to measure second temp source
• Clean particle filter
• Water trap and probe line are empty of water
• Power on and zero
• All hose and thermocouple connections are properly secured
• Flue gas probe is sampling ambient FRESH air
• Water trap is fitted correctly to the instrument
• Flue temperature plug is connected
• Ensure water trap plug is inserted correctly
WARNING
Turning the pump off while the probe is in the flue will leave toxic gases inside the analyzer. Once
data has been printed or copied, it is advisable to purge the unit with fresh air as soon as possible.
To do this remove the probe from the flue and turn ON pump. Always allow the readings to return to
zero (20.9% for O2) prior to shutting the unit off. The meter will not switch off until the CO reading is
below 20 ppm.
CAUTION
The probe will be hot from flue gases. Remove the probe from the flue and allow it to cool naturally.
Do not immerse the probe in water, as this will be drawn into the analyzer and damage the flue
probe and the pump and sensors. NOTE: Take care when
inserting the temperature
probes as the pins are
polarized. Insert with the
smaller pin (+) to the right.
T2 T1
P2 P1
• Remove the protective rubber boot
• Slide the water trap unit from the analyzer
• Remove the particle filter from its’ spigot and replace
• Slide the water trap back into position and replace the protective rubber boot
EMPTYING & CLEANING THE IN-LINE WATER TRAP
CHANGING THE PARTICLE FILTER
QUICK START
Turn on the analyzer by pressing the On/Off Button for 2 seconds until the unit activates. As described the analyzer will perform a 60
second turn on purge. Once completed simply select the reading desired by the position of the rotary dial.
• Remove the rubber plug
• Allow the water to drain out
• Re-insert the rubber plug

8
FRESH AIR PURGE
NOTE
Each time the analyzer is turned on it will perform a 60 second air purge, this is to clear the gas
sampling path (including probe, if connected). For these reasons it is very important that the analyzer
be in outside fresh air when powered on.
STATUS
FLUE 1
AUX
FLUE 2
TEMP
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C161
C
O
C
O
2
T
E
M
P
MEASURING FLUE GASES
After the initial countdown is finished and the analyzer is properly setup, put its’ flue probe in the appliance’s sampling point. The tip of
the probe should be at the center of the flue. Use the flue probes depth stop cone to set the position.
With balanced flues, make sure the probe is positioned into the flue so no air can “back flush” into the probe.
CAUTION!: Ensure the flue probe handle does not get hot!
20”
Boiler
Flue
CO OVER-RANGE PROTECTION PUMP
The analyzer’s intelligent protection system will automatically activate the protection pump once an over-gas condition is detected
(see specification table for detection limits). When activated the main sampling pump will be shut down, allowing the sample system
to be purged with fresh air. Once readings have returned to a safe level, the protection pump will shut down and the main pump will
reactivate.

9
USING THE MENU
Select “Menu” on the rotary switch and navigate using the function buttons:
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.
As you scroll up or down the side LEDs illuminate to point to the active line
MAIN MENU SUB MENU OPTIONS / COMMENTS
SETUP LANGUAGE English
SET TIME HH:MM:SS format
e.g. 7 am = 07:00:00, 7pm = 19:00:00
SET DATE MM/DD/YY format
PRINTER KM IRP
KANE IRP-2
WIRELESS (if installed)
SERIAL
PASSKEY 1111 (wait 5 secs after entering last digit)
BACK
As you scroll up or down the side LEDs illuminate to point to the active line
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.
MAIN MENU SUB MENU OPTIONS / COMMENTS
UNITS FUEL TYPE NAT GAS, TOWN GAS, COKE GAS, PROPANE, BUTANE, LPG,
LIGHT OIL, BIO OIL, WOOD PELLETS, BIO GAS, USER 1 to 5
FUEL ORIGIN UK, FRANCE, SPAIN, N AMERICA, BELGIUM, NETHERLAND
EFFICIENCY GROSS, NET, GROSS COND, NET COND
PRESSURE See next table below
GAS ppm, ppm(n), mg/m3, mg/m3(n), mg/kWh, mg/kWh(n)
TEMP C, F
02REF Up/down to set value (3% default)
NOx CALC Up/down to set value (5% default)
BACK
As you scroll up or down the side LEDs illuminate to point to the active line
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.

10
USING THE MENU CONT.
MAIN MENU SUB MENU OPTIONS / COMMENTS
PRESSURE FILTER FILTER OFF = normal response.
ON = slower (damped) response
RESOLUTION LOW = e.g. 0.00i inH20 resolution.
HIGH = displays to an extra decimal place
UNITS mbar, Pa, PSI, mmHg, hPa, inH2O, mmH20, kPa, psi
BACK
As you scroll up or down the side LEDs illuminate to point to the active line
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.
MAIN MENU SUB MENU OPTIONS / COMMENTS
SCREEN CONTRAST Factory setting is 14
BACKLIGHT 0 to 300 secs
AUX Enables users to customize the parameters on the AUX display:
LINE 1, LINE 2, LINE 3, LINE 4, LINE 5, LINE 6, BACK
BACK
As you scroll up or down the side LEDs illuminate to point to the active line
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.
MAIN MENU SUB MENU OPTIONS / COMMENTS
REPORT AUX Stored AUX tests
VIEW, DEL ALL, BACK
COMBUSTION Stored combustion tests:
VIEW, DEL ALL, BACK
COMMISSION Stored commission tests:
VIEW, DEL ALL, BACK
PRS/TEMP Stored pressure tests:
VIEW, DEL ALL, BACK
EXCH Stored exchange tests:
VIEW, DEL ALL, BACK
ROOM CO Stored room CO tests:
VIEW, DEL ALL, BACK
HEADER LINE 1
LINE 2
BACK
BACK
As you scroll up or down the side LEDs illuminate to point to the active line
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.
MAIN MENU SUB MENU OPTIONS / COMMENTS
SERVICE CODE Password protected for authorized service
agents only. Leave set to 000000.
As you scroll up or down the side LEDs illuminate to point to the active line
NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu”. Any changes that have not been
“entered” will be ignored.

11
USING THE MENU
The Menu position on the Rotary Dial allows for the customization of the default settings for the analyzer as per the user’s
requirements. Navigation through the Menu system is via the dedicated user’s interface buttons (Up, Down, Enter).
As you navigate up or down through the Menu, the items will scroll accordingly, eventually back to the beginning.
Rotate Selector Dial to MENU to set up or customize your settings.
Selected parameter are centered, highlighted with arrow icons on either side.
Use and buttons to scroll menu options.
Press to a select a parameter to edit. Press button to scroll fields to change.
Press and buttons to change field contents.
Press to enter content selected.
The analyzer will perform a 60 second purge in Rotary Dial settings of Aux, Flue 1and Flue 2. This should be done in fresh air.
COMBUSTION TESTS
Insert the tip of the flue probe into the center of the flue. The readings will stabilize within 60 seconds assuming the system conditions are stable.
The rotary switch can be used to display the following information:
FLUE 1
Fuel type can be changed via “MENU” or “STATUS” setting.
Carbon Dioxide (%)
Oxygen (%) left after combustion. Should be 20.9% ± 0.3% in fresh air.
Gross efficiency
Flue temperature (°F).
Inlet temperature (°F). Normally set by flue probe during fresh air purge.
Press to print a full combustion test, (or send to Smart Device via optional Wireless module).
Hold for 2+ seconds to log a full combustion report.
FLUE 2
Fuel type can be changed via “Menu” or “STATUS” setting.
Carbon monoxide (ppm).
Losses calculated
Excess air %
Pressure reading
Press to print a full combustion test, (or send to Smart Device via optional Wireless module).
Hold for 2+ seconds to log a full combustion report.
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S

12
AUX display
The AUX (auxiliary) display can be customized via “MENU” / “SCREEN” / “AUX”.
The parameters displayed on lines 1, 2, 3, 4, 5 and 6 can be set by the user.
They remain the AUX parameters until changed by the user.
Press to print a full combustion test, (or send to Smart Device via optional Wireless module).
Hold for 2+ seconds to log a full combustion report.
COMBUSTION TEST - OPTIONAL NITRIC OXIDE SENSOR
Instructions for C165 Analyzers fitted with optional Nitric Oxide (NO) sensors
Displaying the Nitric Oxide (NO) reading
Select “Menu” on the rotary switch and navigate using the function buttons:
Select SCREEN and then select AUX
Choose a line to display the required readings as below
AUX display
The AUX (auxiliary) display can be customized via MENU / SCREEN / AUX.
The parameters displayed on lines 1, 2, 3, 4, 5 and 6 can be set by the user.
They remain the AUX parameters until changed by the user.
NOTE: To EXIT the MENU at any time simply move the rotary switch to any position other than MENU.
Any changes that have not been “entered” will be ignored.
Use and to navigate to the main menu option SCREEN Press .
Use and to navigate to the sub menu option AUX Press .
The display will show
Press and a third line will appear.
Use and to navigate to the desired parameter to be displayed on line 1.
Press to select the parameter for Line 1 and repeat the process to select the display parameter for
all four lines and then EXIT. Rotate the dial from MENU to AUX to display all your chosen settings.
PRINTING and STORING
The NO readings are printed and stored in the same way as the other combustion gas readings. On the
printouts the NO readings appear directly below the flue CO readings. OR AUX
The dial needs to be in the Flue position or AUX to print or store. When the dilution pump is operating to
protect the CO sensor the NO readings are also affected by an unspecified amount. The screen will
typically show:
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S

13
COMMISSIONING TEST
The Commissioning Test is based on TB143
Introduced in April 2013, Technical Bulletin 143 from the Heating and Hotwater Industry Council (HHIC), outlines a safer, clear and
comprehensive procedure for commissioning condensing boilers without airgas ratio valves. Rotate the dial to “COM TEST” position
and follow the instructions on the screen
TEST 1
Check the boiler at High Fire rate. (Max GAS)
The boiler is switched on at High Fire rate. (Max GAS)
The analyzer is first zeroed in outside fresh air.
Once the boiler is stable at high fire rate the probe is inserted into the air inlet of the flue and the CO2level is measured. The reading
needs to be stable and less than or equal to 0.20%.
TEST 2
The probe is then inserted into the exhaust outlet of the boiler and the Ratio, CO and CO2levels are measured. These levels must be as
per manufacturers instruction. Where manufacturer’s instructions are not available the CO must be less than 350 ppm and the RATIO
must be less than 0.0040.
TEST 3
Checks the boiler at Low Fire flow rate where this is possible.
With the boiler operating stably at Low Fire rate the Ratio, CO and CO2levels are measured. MIN GAS
These levels must be as per manufacturers instruction. Where manufacturers’ instructions are not available the CO must be less than
350 ppm and the Flue 2 must be less than 0.0040.
TEST 4
Measures Flow and Return Temperatures from the boiler
All the measured readings are logged and can be printed or transmitted to PC if an optional wireless module is fitted.
HEAT EXCHANGER INTEGRITY TEST
There are many methods to test heat exchange integrity. One of these is to observe the Excess Air, O2and CO readings both before and
after the blower turns on. If the heat exchanger is sealed, your O2and CO readings should remain fairly stable. A breach in the heat
exchanger may allow fresh air to be forced into the flue after the blower turns on due to pressure increase in the plenum. The result
may be a rise in the measured O2in the stack gas and an increase in Excess Air. In some sealed systems the fresh air drawn in through
the breach may reduce the combustion air available leading to an increase in the CO reading. If either of these situations are present it
is probable there is a problem with the Heat Exchanger which may require additional testing and inspections.
NOTE: Many cracks are invisible to borescopes or the naked eye, and only open or separate from pressure or temperature changes
during operations. Rotate dial to “EXCH TEST” Rotate test selector to “EXCH TEST”. Call for heat on the system. Observe and wait for
O2readings to stabilize.
ROOM CO TEST
No probes or hose connections are required for this test.
Rotate selector dial to Room CO
Press Enter Button to select GENERAL test type
CO readings will be logged every 2 minutes for 30 minutes.
Readings will be saved once the 30 minute test is completed.
Test results and LOG number will be displayed.
Press Print Button to Print the test results.
This LOG will be saved in the REPORTS/ROOM CO MENU screen.
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S

14
[IRP2] [KMIRP2]
PRINTOUTS
COMBUSTION COMMISSION TEST PRS/TEMP HEAT EXCHANGE AUX
PRINTING
Rotate selector Dial to Menu Position.
Use or Arrow Buttons to select Printer.
Press button.
Use or Arrow Buttons to select Printer type (Wireless, KM IRP, Kane
IRP-2, Serial)
Wireless Printer App
Please see pages 15 and 16
To charge Printer (if one is included with Printer) please use included USB
Cable

15
Install the App
• Free download from Apple®App store
• Search for “Kane Wireless Printer” and install
Upon opening App the first time, it will ask you a series of questions:
• Allow access to device location (GPS)
• Allow access to contacts (for emailing)
Kane Wireless Printer App Home iOS Screen
Pairing the Kane Wireless Printer app with your Analyzer
Turn on your analyzer allowing a complete startup
In the App Press PRINTOUT
Select CONNECT TO ANALYZER
• Your Analyzer’s serial number, proceeded by a “K”, should appear
• Select your analyzer to pair
Kane Wireless Printer App Home Screen
Print to App from Analyzer
• When testing in AUX, FLUE 1, FLUE 2, Temp/PRES, HEAT EXCH screen
• Press FILE (Wireless) Button to enter print menu
• Scroll ARROW Button to select Wireless
• Press Button to print to App
To Disconnect an analyzer
• Select disconnect from Printout screen
Adding Notes & Emailing from the Kane Wireless Printer App
In PRINTOUT screen, Select EMAIL PRINTOUT
• A message window will open
• Enter email address
• Add message/notes to Printout
• Send message
Select CLEAR CONSOLE to delete a Printout
• Press to Confirm deletion
To print Saved LOGS from Analyzer to App
To print Saved LOGS from Analyzer to App
• Rotate Selector dial to MENU
• Press or Arrow Buttons to select LOGS. Press Button
• In the LOGS screen. Press Button to VIEW.
• Press or Arrow Buttons to select LOGS VIEW you want. Press Button
Select the analyser model you’re
connecting to.
Select Analyser
TEXT CAPTURE STYLE
YOUR NAME
Your Name
Printer Settings
Your Company
YOUR COMPANY NAME
Select what test processing style
you’d like to use.
Provide your name to use for
correspondence from the App...
Provide your Company name for
correspondence from the App...
12:00 PM 100%
ANALYSER TYPE
Connect to Analyser
Email Printout
Clear Console
SERIAL NO.
DATE
TIME
CAL DUE
COMBUSTION
FUEL
CO2
O2
CO
CO/CO2
1234567880
11/16/19
13:19:07
09/26/20
NAT GAS
0.11
20.76
1
0.0009
Printer Print out
12:00 PM 100%
ppm
F
00
00
iOS APP GUIDE

16
24%
12:00 Provider
KANE Wireless Printer
Connected to AUTOplus 051717..
AUTOplus V1 . 08
SERIAL No. 051717568
YOUR COMPANY NAME &
PHONE NUMBER HERE
DAT E
TIME
VEHICLE
FUEL
CO2 %
CO %
O2 %
HC ppm
NO ppm
Lambda
11/04/18
09:19:52
AB11 DEF
GAS/PETROL
-0.0
-0.00
20.94
-0
0
----
Installing the App
• Free download from Google Play
• Search for “Kane Wireless Printer” and install
Upon opening App the first time, it will ask you a series of questions:
• Allow access to device location (GPS)
• Allow access to contacts (for emailing)
Kane Wireless Printer App Home Android Screen
Start up
• Press the Menu icon in top left of screen
• Press Settings
A. Select “Your Name”, enter name and Press “OK”
B. Select “Your Company Name”, enter name and Press “OK”
C. Select “Analyser Type” select “Other Kane Analyser”
Kane Wireless Printer App Android Settings Screen
Pairing the Kane Wireless Printer app with your Analyzer
• Turn on your analyzer and allow it to complete its startup
• Touch the Kane Wireless Printer banner of the home page
• From the “Pick a device” screen, touch “Scan For Devices” at the bottom of the page
• Your Analyzer’s serial number, proceeded by a “K”, appears of the list. Select it to pair
Print to App from Analyzer
• When testing in AUX, FLUE 1, FLUE 2, Temp/PRES, HEAT EXCH screen
• Press FILE (Wireless) Button to enter print menu
• Scroll Arrow Button to select Wireless
• Press Button to print to App
To Disconnect an analyzer
• Select disconnect from Printout screen
Adding Notes & Emailing from the Kane Wireless Printer App
-After a report is on the app, Press the Pen icon on the top right of the app screen.
• Press “Write your note here” and you can type your notes for the report. Press “OK”
icon when done and it will save the note under the report.
• Press the “3 vertical dots” icon on the right side of the screen
• From that drop-down menu, Press “Email” icon
• Find and select your email app from the list. The email app will open to a new message and
your report will be attached
Kane Wireless Printer App Android Personal Details Screen
To print Saved LOGS from Analyzer to App
• Rotate Selector dial to MENU
• Press or Arrow Buttons to select LOGS. Press Button
• In the LOGS screen. Press Button to VIEW.
• Press or Arrow Buttons to select LOGS VIEW you want. Press Button
24%
12:00 Provider
Enable NightMode function
on Facebook
onTwitter
onYouTube
Visit Kane
Share this app
Feedback
Help
Settings
SW No.: 19086
SW ver: 1.4.5
24%
12:00 Provider
Personal Details
Application Settings
Your Name
Provide your name to automatically use in correspondence
AnalyserType
Select the analyser model you’re connecting to
Advanced Info
Export GPS & Date-Time data
Show available GPS & Date-Time info in your
exported printout
NightMode sensor
Use light sensor to determine NightMode level
GPS Tagging
Tag printouts with gps location
Printout Font Scaling
Change the font scale so your printout fits better on-screen
Your Company Name
Provide your company name to automatically use in
correspondence
ANDROID APP GUIDE

17
PRESSURE/TEMPERATURE TESTING
Select the Temperature Rotary Dial position.
Use the T1 connection for the Flue Probe temperature sensor
Use the T2 connection for the Inlet temperature sensor
Real time temperature difference
Real time pressure reading
WARNING
NEVER ATTEMPT TO TAKE A PRESSURE READING WITHOUT KNOWING THE MAXIMUM PRESSURE THAT MIGHT BE PRESENT. THIS
INSTRUMENT’S PRESSURE TRANSDUCER IS RATED AT 1.1 PSI WITH A MAXIMUM OVER RANGE OF 5.8 PSI.
Select “PRS/TEMP”. The pump stops automatically. Using the black connectors and manometer hose, connect to P1 for single pres-
sure or P1 and P2 for differential pressure.
Pressure units can be selected via “MENU”.
Eg Flow Temp
Eg Return Temp
Differential Temp
Press to print a full pressure test, (or send to Smart Device via optional Wireless module).
Hold for 2+ seconds to log a pressure report.
PRESSURE MEASUREMENT GOOD PRACTICE
WARNING
Before using the UEi C165 to measure the pressure of a gas/air ratio valve, read the manufacturer’s manual thoroughly. If in doubt,
contact the manufuctuer.
After adjusting a gas/air ratio valve, it is essential the CO, CO2are within the manufacturer’s specified limits.
LARGE BORE TUBING ISSUES
If using larger bore tubing when performing pressure tests:
Push tubing over the rim of the This may not produce a gas tight seal.
spigot to ensure a gas tight seal.
Status
Flue 1
Aux
2eulLF
Com Test
Prs/Temp
Exch Test
Room CO
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C165
C
O
C
O
2
T
E
M
P
P
R
S

18
ANALYZER SPECIFICATIONS
PARAMETER RANGE RESOLUTION ACCURACY
Temp Measurement
Flue Temperature
Inlet Temperature
(Internal sensor)
Inlet Temperature
(External sensor)
32°-1112°F
32°-122°F
32°-1112°F
0.1°F
0.1°F
0.1°F
±3.6°F
±0.3% reading
±3.6°F
±0.3% reading
±3.6°F
±0.3% reading
Flue Gas Measurement
Oxygen*2
Carbon monoxide*1
Carbon dioxide*1
Efficiency (Net or Gross)*2
Efficiency High (C)*2
Excess Air*2
CO/CO2ratio*2
0-21%
0-20ppm
21-2,000ppm
Above 2000ppm
Purge pump
operates
0-20%
0-99.9%
0-119.9%
0-250%
0-0.999
0.1%
1ppm
0.1%
0.1%
0.1%
0.1%
0.0001
±0.3%
±3ppm
±5% reading
unspecified
±0.3% volume
±1.0% reading
±1.0% reading
±0.2% reading
±5% reading
Nitric Oxide Sensor
(optional)
0 to 100ppm
Overrange to 1500ppm
1ppm + 2ppm <30ppm*1
+5ppm <100ppm*1
+5% reading >100ppm
Pressure (differential)
Nominal range 32”
Maximum over range without
damage to sensor is 60”
±0.2 mbar (±0.080 inWC)
±1 mbar (±0.401 inWC)
±80 mbar (±32 inWC)
Maximum 0.001 mbar
<25 mbar
(0.001 inWC < 10.016)
±0.005 mbar (±0.002 inWC)
±0.03 mbar (±0.080 inWC)
±3% of reading: same
Pre-programmed Fuels Natural gas, Propane, Butane, LPG, Light Oils (28/35 sec), Wood Pellets, Town Gas, Coke Gas, Bio Oil, Bio Gas
User programmed Fuels 5 user defined fuels
Storage Capacity 30 Total Tests
*1 Using dry gases at STP
*2 Calculated

19
ANALYZER SPECIFICATIONS CONT.
Carbon Dioxide resolution is 0.01% below 1% measured value.
Ambient Operating Range 32° to 113°F (0° to 45°C) 10% to 90% RH
Storage Temperature Range 0° to 120°F (-18° to 50°C)
Battery Type / Life 3 AA cells
>8 hours using Alkaline AA cells
Chargers (optional) 100-240v charger, for NiMH batteries only
Dimensions
Weight:
Handset:
Probe:
0.8kg handset with protective rubber cover
7.87 x 1.77 x 3.5 in (200 x 45 x 90mm)
11.8 in (300mm) long including handle.
2.3 dia. x 9.4 in (6mm dia. x 240mm) long stainless-steel shaft with 6.5ft
(2m) long neoprene hose. Type K thermocouple
CO Protection Pump: Operates at 2000ppm measured CO.
The C165 is in conformity with the relevant Union harmonization legislation listed below:
Directive Title
201430EU Electromagnectic Capability
201165EU Restriction of use of certain hazardous substances in electrical
and electronic equipment (RoHS)
The following harmonized standards and technical specifications have been applied:
CERTIFICATION
The UEi C165 is TUV-tested and certified to EN 50379, Parts 1, 2 & 3 in accordance to 1st German Federal Emission Control Ordinance
(BlmSchV)
EMC
EN507270:2015
Safety
EN61010-1:2010
RoHS
IEC62321-2:2013, IEC62321-1:2013; IEC62321-3-1;2013, IEC63321-5:2013, IEC623321-4:2013, IEC62321-7-2:2017, IEC62321-7-1:2015,
IEC62321-6:2015, AHRI 1260
ELECTROMAGNETIC COMPATIBILITY
European Council Directive 89/336/EEC requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and
have adequate immunity levels for normal operation. Specific standards applicable to this analyzer are stated below.
As there are electrical products in use pre-dating this Directive, they may emit excess electromagnetic radiation levels and, occasionally, it may be
appropriate to check the analyzer before use by:
Use the normal start up sequence in the location where the analyzer will be used.
Switch on all localized electrical equipment capable of causing interference.
Check all readings are as expected. A level of disturbance is acceptable.
If not acceptable, adjust the analyzer’s position to minimize interference or switch off, if possible, the offending equipment during your test.
At the time of writing this manual (November 2020) UEi Test Instruments is not aware of any field-based situation where such interference has
occurred, and this advice is only given to satisfy the requirements of the Directive. This product has been tested for compliance with the following
generic standards and is certified to be compliant.
EN 61000-6-3 : 2011
EN 61000-6-1 : 2007
Specification EC/EMC/KI/C165 details the specific test configuration, performance and conditions of use.

20
WHERE TO TEST
Air Conditioning / Heat Pump
Boiler & Water Heaters & High Efficiency Modulating Hot Water Systems
Furnaces: 80% Furnaces: 90%
Suction Line:
• Temperature
Verify proper:
• Static Duct Pressures
• Temperature Differential
• Static Pressure Drop Across Coils
Boiler
Verify proper combustion:
• O2
• CO2
• CO Air Free
• Stack Temp
• Stack Draft
Water Heater
Draft
Verify proper combustion:
• O2
• CO2
• CO
• Stack Temp
• Efficiency
HE Boiler Instant Water
Heaters
Draft
Verify proper
combustion:
• O2
• CO2
• CO
• Stack Temp
• Efficiency
Hi / Low fire
Gas Pressure
Supply and Return Water temp
80% Furnace
Verify proper combustion:
• O2
• CO2
• CO
• Stack Temp
• Vent Pressure
• Efficiency
Verify/Set Up
• Gas Pressure
Test
• Limit Switch
• Pressure Switch
Verify proper operation:
• Static Duct Pressure
• Temperature Rise
• AC side Static Pressure
Drop across coils
to condensing unit
90%+ Furnace
Verify proper combustion:
• O2
• CO2
• CO
• Stack Temp
• Vent Pressure
• Efficiency
Verify/Set Up
• Gas Pressure
Test
• Limit Switch
• Pressure Switch
Verify proper operation:
• Static Duct Pressure
• Temperature Rise
• AC side Static Pressure
Drop across coils
Other manuals for C165
4
Table of contents
Other UEi Measuring Instrument manuals