manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. UEi
  6. •
  7. Multimeter
  8. •
  9. UEi M20 User manual

UEi M20 User manual

M20
INSTRUCTION MANUAL
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Introduction
The M20 has features you need for testing residential electrical and
HVAC/R systems. With its four AC and four DC voltage scales you can
measure typical control and source voltages with high resolution. It also
includes a low-ohm scale to test critical connections and a milliamps
function to verify many flame safeguard circuits.
Features include
• 12 ranges
• 500 Volts AC and DC
• DC milliamps
• Fused ohm circuit
• Resistance to 500 kilohms
• Color-coded and mirrored scale plate
Safety Notes
Before using this meter, read all safety information carefully. In
this manual the word "WARNING" is used to indicate conditions
or actions that may pose physical hazards to the user. The word
"CAUTION" is used to indicate conditions or actions that may
damage this instrument.
Operating Instructions
AC Voltage
Insert one test lead in the “+VΩM” jack. Insert the other test lead in the
“COM” jack. Set the function switch to the appropriate AC voltage.
NOTE: Always start with the 500V range if unsure of the magnitude of
voltage present.
CAUTION!
Always remove the test leads from the circuit under test before
disconnecting from front panel of M20.
DC Voltage
Insert the black test lead in the “COM” jack. Insert the red test lead in
to “+VΩM” jack. Set the function switch to the appropriate DC voltage.
The red test lead is connected to the positive voltage point. The black
test lead is connected to the negative voltage point.
NOTE: Always start with the 500V range if unsure of thee magnitude of
voltage present.
CAUTION!
Always remove the test leads from the circuit under test before
disconnecting from front panel of M20.
Direct Current
The M20 may be used to measure direct current up to a maximum
of 250 mA (0.250 Amps). To do this, the M20 must be connected in
series with the wire, or circuit element, in which the current is to be
measured. Remove power to the circuit under test before connecting
the M20. Set the function switch to the 250 mA position. Insert the black
test lead between the “COM” jack on the M20 and the ground, or low
voltage, side of the circuit test. Insert the red test lead between the
“+VΩM” jack on the M20 and the high voltage side of the circuit under
test. Apply power to the circuit under test.
Resistance
CAUTION!
Always remove power to any circuit in which resistance measurements
are to be made.
The M20 uses an internal battery to supply power to the circuit under
test. Access to the battery and the protective fuse is provided by
removing the single screw on the back of the case and removing the
case back. Observe polarity marking on battery.
Set the function switch to the appropriate OHMS setting, Rx1,Rx10, or
Rx100. Insert one test lead in the “COM“ jack and the other test lead
in the “+VΩM”jack. Touch the free ends of the test leads together and
note that pointer will swing to the right side of the scale. (Note: If the
pointer does not move all the way to the right the battery may be
weak and need replacing. If no reading can be made, check battery
and fuse) Use the green “OHM ADJ” knob to set the pointer to
zero on the green meter scale. This completes the calibration of the
resistance measuring circuit. This test should be performed each time
resistance tests are to be made to assure that the “OHM ADJ” knob
has not been inadvertently moved.
To make the resistance measurement, connect the free ends of the
test leads across the element to be measured. The measured resistance
value will be the green numeral on the resistance scale times the
resistance multiplier. For example, if the function switch is on Rx100
and the pointer is on the numeral 20, the resistance is 2,000 ohms
(100 x 20 = 2000).
Testing Diodes / Transistors
A simple check of diode or transistor quality may be made with the
M20. Using the same test procedure as for measuring resistance,
connect one test lead to one end of the diode and the other test lead to
the other end of the diode. Note the resistance reading. Then reverse
the test leads and again not the reading.
If the two readings differ by a factor of ten then the diode, (or transistor
junction) is probably good. If the two readings are approximately the
same then the diode is shorted. If a reading cannot be obtained in
either direction, the diode is probably open.
M20-MAN P. 1
S p e c i f i c a t i o n s
Standard Accessories
Test leads (set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ATL3
Alligator clip adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AAC
Fuse 0.15A, 2Ω. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AF2
Battery 1.5V, size AA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AB1
M a i n t e n a n c e
Periodic Service
WARNING!
Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from
electrical shock and personal injury this meter provides to the
operator. Perform only those maintenance tasks that you are
qualified to do.
These guidelines will help you attain long and reliable service from
your meter:
•Calibrate your meter annually to ensure it meets original
performance specifications
• Keep your meter dry. If it gets wet, wipe dry immediately.
Liquids can degrade electronic circuits
•Whenever practical, keep the meter away from dust and
dirt that can cause premature wear
•Although your meter is built to withstand the rigors of daily
use, it can be damaged by severe impacts. Use reasonable
caution when using and storing the meter
Cleaning
Periodically clean your meter’s case using a damp cloth. DO NOT use
abrasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or affect the reliability of the
structural components.
Battery Replacement
The internal 1.5V battery affects only the OHMS function. It should be
replaced when it is no longer possible to zero the pointer with the
“OHM ADJ” control. Remove battery if M20 is not to be used for a
long period of time. Remove single-screw in rear of case for access to
battery. Observe polarity.
Fuses
The fuse affects only the OHMS function. Replace fuse only with one of
same current rating and internal resistance, 0.15A and 2.0Ω. Use of a
fuse with different internal resistance may cause inaccuracy on the
OHMS scale. Remove single screw in rear of case for access to fuse.
Mechanical Zero Adjustment
The pointer should indicate 0 at the left hand edge of the scale with no
input and M20 placed face up on a flat surface.
To reset pointer, carefully adjust clear plastic screw located in meter face.
M20-MAN P. 2
AC Voltage ±4% of full scale 0 - 10, 50, 250, 500 Volts
DC Voltage ±3% of full scale 0 - 10, 50, 250, 500 Volts
Direct Current ±3% of full scale 0 - 250 mA
Resistance ±3% of scale length 0 - 5K, 50K, 500KΩ
Internal Battery 1.5V, size “AA”
Fuse 0.15A, 2Ω
Limited Warranty
The M20 is warranted to be free from defects in materials and workmanship for a period of
three years from the date of purchase. If within the warra n ty period your instrument should
become inoperative from such defects, the unit will be repaired or replaced at UEi’s option.
This warra n ty covers normal use and does not cover damage which occurs in shipment or
failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed batteries are not
covered by warra n ty.
Any implied warranties, including but not limited to implied warranties of merchantability
and fitness for a particular purpose, are limited to the express warranty. UEi shall not be
liable for loss of use of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such damage, expenses or
economic loss. A purchase receipt or other proof of original purchase date will be required
before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when
repairable) for a service charge. Return the unit postage paid and insured to:
This warranty gives you specific legal rights. You may also have other rights which vary from
state to state.
M20
Analog Multimeter
Copyright © 2007 UEi M20-MAN 1/07
PLEASE
RECYCLE
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Other UEi Multimeter manuals

UEi DM525 User manual

UEi

UEi DM525 User manual

UEi DM505 User manual

UEi

UEi DM505 User manual

UEi DM420 User manual

UEi

UEi DM420 User manual

UEi DM5B User manual

UEi

UEi DM5B User manual

UEi UTL33T User manual

UEi

UEi UTL33T User manual

UEi DL419 User manual

UEi

UEi DL419 User manual

UEi DM391 User manual

UEi

UEi DM391 User manual

UEi ADM33201 User manual

UEi

UEi ADM33201 User manual

UEi DM525 User manual

UEi

UEi DM525 User manual

UEi DM397 User manual

UEi

UEi DM397 User manual

UEi UTL33 User manual

UEi

UEi UTL33 User manual

UEi DM505-N User manual

UEi

UEi DM505-N User manual

UEi DM515 User manual

UEi

UEi DM515 User manual

UEi DM383B User manual

UEi

UEi DM383B User manual

UEi M110A User manual

UEi

UEi M110A User manual

UEi DM383 User manual

UEi

UEi DM383 User manual

UEi DM400 User manual

UEi

UEi DM400 User manual

UEi Phoenix Series User manual

UEi

UEi Phoenix Series User manual

Popular Multimeter manuals by other brands

Duratool D03046 operating instructions

Duratool

Duratool D03046 operating instructions

PeakTech 3336 Operation manual

PeakTech

PeakTech 3336 Operation manual

Gossen MetraWatt METRAHIT Base operating instructions

Gossen MetraWatt

Gossen MetraWatt METRAHIT Base operating instructions

GW Instek GDM-8261A user manual

GW Instek

GW Instek GDM-8261A user manual

I.C.E Supertester 680 R Operator's manual and repair guide

I.C.E

I.C.E Supertester 680 R Operator's manual and repair guide

Keysight M9182A Calibration and Verification Procedure

Keysight

Keysight M9182A Calibration and Verification Procedure

Mgl KPS-MT460 instruction manual

Mgl

Mgl KPS-MT460 instruction manual

Amprobe HD110C user manual

Amprobe

Amprobe HD110C user manual

EZ Digital DM-330SRS Operation manual

EZ Digital

EZ Digital DM-330SRS Operation manual

Mastech M840D Operation manual

Mastech

Mastech M840D Operation manual

Rigol DM3058 Calibration guide

Rigol

Rigol DM3058 Calibration guide

Hioki DT4281 instruction manual

Hioki

Hioki DT4281 instruction manual

Tenma 72-3097 manual

Tenma

Tenma 72-3097 manual

Fluke 87V MAX user manual

Fluke

Fluke 87V MAX user manual

Tektronix DMM912 Instructions for use

Tektronix

Tektronix DMM912 Instructions for use

VOLTCRAFT VC 260 user manual

VOLTCRAFT

VOLTCRAFT VC 260 user manual

Velleman DVM101 user manual

Velleman

Velleman DVM101 user manual

CABAC BM821 Operation manual

CABAC

CABAC BM821 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.