Operators Manual

Table of Contents
Introduction 1
Warning 1
Important Safety Instructions 1
Safety Precautions 1
Fog Curtain Components 2
Fog Curtain Design Example 4
Design Considerations 4
Maintenance 5
Trouble Shooting 5
Warranty 6
Contact Information 7
Note: Please read entire manual before setting up and operating the Fog Curtain System

1www.ultratecfx.com
Warning!!
WARNING!!
Introduction
1. Persons suffering from asthma or allergenic sensitivity may experience irritation, discomfort or allergic
symptoms when exposed to fog effects.
2. Use Ultratec Special Effects fluid ONLY.
Important Safety Instructions:
WARNING!!
1. Ensure that any operation of the machine is supervised by suitably trained and authorized personnel.
2. Allow sufficient air circulation around the machine at all times.
3. Only use fluids manufactured by Ultratec Special Effects.
4. Do not continue to produce fog when visibility is reduced to 20” 50cm or below.
5. Ensure that adequate exhausting arrangements are available in the event of an emergency.
6. Fog effects will trigger smoke alarms and detectors. Please take suitable precautions to prevent
false alarms.
7. Ensure sufficient air exchange vs. CO2 released.
CO2 is heavier than air and will pool in higher concentrations in lower lying areas like orchestra
pits and below stage.
WARNING!!
Safety Precautions
The Fog Curtain is your solution for a large reveal or a unique medium to project images or lighting on.
The Fog Curtain is designed to be used in conjunction with the Eclipse Low Fog Generator.
The Liquid CO2 conditioned fog effect can fall from heights of up to 30´ and depending on the number of Eclipse
systems used, the length of the curtain is almost limitless.
A single Eclipse system will allow up to a 6-meter (20 feet) length of fog curtain.
This effect has been successfully utilized on cruise ships, casinos, theme parks and stages around the world.

CLF-2956 Non-insulated 10" Hose 25' w/10" Hose Clamp
The Non-insulated 10" Hose is easy to deploy and stow for quick low fog cues, or
where the installation is temporary, such as touring.
CLF-9033 10" Flex to Rigid Adapter
The 10" Flex to Rigid Adapter allows the mating together of 10” flexible hose to the
10” Fog Curtain Pipe or any rigid fitting.
CLF-9035 10" Tee
The 10” is comprised of a straight run with a 90 degree branch.
CLF-9036 10" 90* Elbow
Long radius 90* elbow
CLF-9038 10" Fog Curtain Pipe (10' Length w/Holes)
The 10" Fog Curtain Pipe is the heart of the fog curtain system. The fog curtain pipe,
with its airflow straighteners, creates a spectacular curtain of brilliant white fog when
coupled with the Eclipse Low Fog Generator.
CLF-2957 Flex Hose Adapter S.S.
Used to quickly connect a flex hose to our legacy low fog generator.
Fog Curtain Components
www.ultratecfx.com 2
Flex Hose Adapter S.S.
10" Flex to Rigid Adapter
Non-insulated 10" Hose 25'
w/10" Hose Clamp
10" Tee
10" 90* Elbow
10" Fog Curtain Pipe
(10' Length w/Holes)

3www.ultratecfx.com
10” Automatic Round Damper
CLF-2985 10" Automatic Round Damper (ARD) 110V
CLF-2986 10" Automatic Round Damper (ARD) 220V
The 10” Automatic Round Damper (ARD) is an inline damper that will open or close
to allow or prevent fog from flowing down a run of 10” ducting. See ARD Manual
for complete operating instructions. 10" Automatic Round Damper
CLF-9040 10" Fog Curtain Coupler
Are these the plastic clamshell type??
CLF-9039 10" Rigid Pipe (10' Length)
The 10" Rigid Pipe is ideal for long runs or permanent installations as it creates less
internal turbulence than the flexible 10” hose. It can be easily cut to length for
installation with a reciprocating saw.
10" Rigid Pipe (10' Length)
CLF9045 Fog Curtain Metal Bracket
The Fog Curtain Metal Bracket acts as a coupler to join 2 10" rigid pieces together,
and as a point to hang the fog curtain from (additional field supplied hardware is
necessary).
For a more rigid connection a CLF9032 4 1/2" Sleeve can be used in conjunction to
stiffen the joint.
A CXP4088 – Fog Curtain Foam Gasket may be required if fog leakage at the joint
happens (sold Separately)
CLF9050 Fog Curtain End Plate Plastic
The Fog Curtain End Plate Plastic is used to terminate the run on any 10" rigid piece.
A CXP4088 – Fog Curtain Foam Gasket is included to minimize leakage at the
connection.
CXP4088 – Fog Curtain Foam Gasket
Fog Curtain Foam Gasket may be required if fog leakage at the joint happens.
Fog Curtain Metal Bracket
Fog Curtain End Plate Plastic
Fog Curtain Foam Gasket

4
www.ultratecfx.com
10" End Cap
Non-insulated 10" Hose 25' w/10" Hose Clamp
10" Tee
10" 90* Elbow
10" Automatic Round Damper
10" Fog Curtain Pipe (10' Length w/Holes)
Eclipse Low Fog
Generator
10" Flex to Rigid Adapter
10" Flex to Rigid Adapter
Fog Curtain Metal Bracket
Fog Curtain Design Example
Below is a simple example of a fog curtain layout. The key to this design, and any design where the low fog
is ducted above the source, is the 10" ARD (10" Automatic Round Damper ) and the 10" Tee. This
configuration allows a path for any fog returning down the pipe to exit the 10" Tee and not flow back
through the eclipse and fog machine when the low fog cue is ended.
While the fog cue is running the 10" ARD is in the closed position, directing the low fog to the fog curtain.
When the fog cue ends, open the ARD and allow the fog to flow out of the Tee and ARD. This will help
prevent fog from traveling back into the Eclipse and ultimately through the fog machine and condensing on
the electronic components.
Design Considerations
Some residue is expected to condense inside the piping during normal operation. Some design
considerations can help manage the residue.
ŸUse stainless steel fasteners to reduce oxidization (rusting)
ŸSlope tubing/pipe slightly to encourage any residue to collect at the lowest point.
ŸAdd a condensate drain and collection setup to manage residue collection.
Non-insulated 10" Hose 25'
w/10" Hose Clamp
10" Flex to Rigid Adapter

5www.ultratecfx.com
Please remember to include the RA Number on all items being shipped
for repairs.
To request a Return Authorization number please refer to our website - instructions below:
1) www.ultratecfx.com
2) Click on the Fog & Atmospheric Icon
3) Click on the REQUEST RMA Tab along the top of the screen
4) Fill in the required information
5) Click "Submit" button
If you have any questions or require assistance please contact service at
519-951-3357/866-534-5557 or by email at [email protected]..
Hardware products come with a five-year warranty on parts and labor. If the unit in question has a material
defect or fault that is caused in manufacturing, Ultratec Special Effects will provide free parts and labor to
remedy the equipment. Ultratec Special Effects service department must be advised in a timely manner
after defect appearance and the date of warranty request must be within five years of sale/purchase. Proof
of sale and/or proof of purchase will be required for warranty to take effect.
Warranty service will be performed as follows: faulty parts will be repaired or replaced with the same or
comparable parts, based on availability. Freight to our facility for warranty requests will be prepaid by the
user/dealer. Upon completion of the repair, Ultratec Special Effects will return the unit via the most
economical means available. Should you require the item express-returned, the user/dealer is responsible
for indicating this request and for any difference in freight cost.
Warranty will be voided, and customer will lose all rights guaranteed by the warranty if any of the following
are observed/occur:
If any non Ultratec Special Effects fluid is used at any point of operation.
If any adjustments or repairs are done to the machine in question by repair technicians not authorized by
Ultratec Special Effects.
If our repair technicians observe any signs of incorrect handling/treating of machine in question.
Warranty services do not cause an extension of the warranty nor does a repaired product start a new
warranty. This warranty only applies to the product supplied by Ultratec Special Effects, Ultratec Special
Effects is not responsible for any losses, costs, or damages from the use of a defective product.
Any additional costs incurred are the responsibility of the Dealer and/ or the customer.
An RA (Return Authorization) number must be noted on the outside of each box being returned to our
facility. Any package(s) without an RA number clearly marked, will not be accepted by our receiving
department.
Export Distributors are required to carry out the warranty repair, parts will be supplied by
Ultratec.
Please do not forget to remove any liquid from the machine when sending in for repair.
Warranty

6
www.ultratecfx.com
Head Office
Ultratec Special Effects
1960 Blue Heron Drive
London, Ontario N6H 5L9
Direct: 519-659-7972
Toll Free: 800-388-0617
Fax: 519-659-7713
Europe Office
Ultratec Special Effects GmbH
Dieselstrasse 30-40
60314
Frankfurt am Main
Germany
Direct: 49-69-87-000-1850
Fax: 49-69-87-000-1899
Canadian Shipping Address
(For All Canadian Repairs)
Ultratec Special Effects
1960 Blue Heron Drive
London, Ontario N6H 5L9
USA Shipping Address
(For All USA Repairs)
Ultratec Special Effects
640 Gadson Street
Groveland, Florida 34736
Contact Us