ULTTY SKJ-CRS01 User manual

Household Disinfectant Generator
Instruction Manual
SKJ-CRS01
Please read this manual before using

Assembly
Air pressure handle
Spray nozzle
Straw
Air inlet
Max water level
Cup body
Electrode net
Touch button
Spray button
Handle
Power connection hole

electrolysis
Features
The SKJ-CRS01 Household Disinfectant Generator is a safe smart device designed to
make 100% natural, non-toxic and broad-spectrum disinfectant at home. With a
simple solution of salt and water, and a bit of power, the device makes medical NaClO
disinfectant. NaClO disinfectant kills 99.99% of germs on hard, nonporous, nonfood
contact surfaces by soak, wipe, spray. Kills E. coli, Staphylococcus aureus, Candida
albicans, polio virus, etc.
Principle
NaClONaOHClOHClN 22a
The principle is the same as common industrial production of NaClO disinfectant.
Electrolysis the salt water to make the NaClO disinfectant.
Operating
1. Connect the power, the machine turn to standby, the blue LED of the cup body turn
on, after the blue light is off, click the touch button to select the corresponding mode.
2. Click to select and start the mode directly.
a. Click once select the Beauty Mode, blue LED flicker once, machine auto start.
b. Click twice in 3s select the Disinfectant Mode, blue LED flicker twice, machine
auto start.
c. Click thrice in 3s select Wash-water Mode, blue LED flicker thrice, machine auto
start.
No operation in 3s, the machine start working and the blue LED will stay on. In
working state you can disconnect the power and stop the machine.
3. Working time: 3 minutes in Beauty Mode and Disinfection Mode, 10 minutes in
Wash-water Mode.
4. After work finished, the blue LED go off and the machine turn to standby.

Working Mode
Beauty Mode
Electrolysis the pure tap water , 3 minutes. (no salt!)
Function: effective removing chemicals and impurities, make extremely clean alkaline water(PH≈7.5).
Its function is equivalent to basic cosmetic water.
Note: you can repeat the electrolysis 2-3 times, pour out the water for perfect cleaning, then
re-introduce water start working.
Disinfectant Mode
330ml Tap Water + 2g Salt, shake the cup 30-60s to fully dissolve the salt. Run 3 minutes to make
NaClO disinfectant concentration ≥200mg / L
Function: Spraying or soaking, for cleaning, decontaminating, sterilizing.
Suitable for toothbrushes, dentures, pet supplies, toys, air conditioners, shoe cabinets, bath towels,
bedding, and various kitchen supplies.
Wash-water Mode
330ml Tap Water + 2g Salt, shake the cup 30-60s to fully dissolve the salt. Run 10 minutes to make
NaClO disinfectant concentration ≥500mg / L
Function: Spray, soak or wipe with a towel, for sterilizing, deodorizing, bleaching and washing the
items.
Suitable for underwear, toilet, bathroom, trash can, hospital, sewer, and the place where mold is
breeding.
Tap Water
330ml
No Salt
3 minutes
Tap Water
330ml
Salt
2g
10 minutes
Tap Water
330ml
Salt
2g
3 minutes

do not introduce water
exceed the maximum line
(330ml)
add salt
1 spoon≈2g
stri or shake
30-60s
cover
clockwise
click to select
mode and start
blue LED will
stay on during
working
blue LED
turn off,
disinfectant
ready
adjust
spraying
Increase
air pressure

Reference
Target
Concentration
(mg/L)
Duration
(min)
Instructions
General
surface
100~250
10~30
Wipe, soak, rinse and disinfect the surface
of various clean objects.
400~700
10~30
Wipe, soak, rinse, and spray disinfect the
surface of various non-clean objects.
Tableware
Sanitary Standards for Tableware
Disinfection
Immersed and disinfected the cleaned
tableware; washed out after disinfection.
400
20
Disinfecting the cleaned tableware used by
patients with infectious disease; washed
out after disinfection.
500~800
30
Disinfecting the non-cleaned tableware
used by patients with infectious diseases;
washed out after disinfection.
Fabric
250~400
20
Immersed and disinfected the fabric;
washed out after disinfection.
Concentration, Time required to kill various microorganisms
Concentration
(mg/l)
Duration
(min)
Effect
100
10
Kill E. coli, Staphylococcus aureus≥99.99%
200
10
Kill Pseudomonas aeruginosa≥99.999%
Kill Candida albicans≥99.99%
200
20
Kill Poliovirus-I vaccine strain≥99.99%
500
60
Kill Bacillus subtilis spores≥99.99%

Notes
1. The water and disinfectant produced by this machine is for external. Do not
drink and placed in a place where children can not reach;
2. Operate the machine in accordance with the manual;
3. Do not perform other operations during the generation process to avoid
damage to the equipment;
4. During the working process, it is normal for yellow willow-like precipitates
to appear in the solution. This is because the water is rich in iron ions, and the
above phenomenon will also occur when using table salt containing potassium
ferrocyanide;
5. Please use the generated disinfectant in time, otherwise the concentration of
disinfectant will decrease due to the influence of light and temperature, and the
residence time of disinfectant in the cup should be reduced to extend the
service life of the equipment.
6. Use the generated disinfectant as much as possible on the spot. Excess glass
or plastic bottles should be sealed from light, dark and dry place and
well-ventilated clean room, and the storage time should not be too long.
7. Sodium hypochlorite disinfectant is corrosive to metals. Use with caution.
8. It is forbidden to use disinfectant to sterilize and sterilize textiles woven with
natural fibers other than white to prevent discoloration.
9. Do not use with alcohol, vinegar, toilet spirit, or concentrated sulfuric acid at
the same time.
10. Disinfectant can be used to clean the humidifier, but it is not recommended
to keep it in the humidifier water tank.
11. When not in use for a long time, open the cup cover, store it upside down,
and dry it.

Safety Instructions
1.Children, the elderly and people with disabilities or without experience should be
looked after by a responsible person when using this product. Children should be
supervised to ensure that they are not playing with the machine as a toy.
2.Please use a separate outlet according to the current / voltage of the device. Do not
use a multi-purpose socket for simultaneous use with other electrical devices.
3.If the machine does not work due to a damaged power cord, switch off the power
supply and ask a qualified person for repair.
4. Do not pull out the plug by the cable. Pull out the plug and do not grip the cable.
5. Do not stretch or energize the cable. Keep the cable away from the heat source.
6.Turn off all controls before pulling the plug and pull the plug out of the socket if
you are not going to use the device for a long time.
7. Do not immerse the machine, power cord or plug in water or other liquids to avoid
danger. The use of an extension cord is not recommended unless it has been tested by
a qualified person.
8. Please do not use an air cleaner or similar product directly next to the machine. Do
not use detergents or lubricants for this machine and pull the power plug before
cleaning, transporting and servicing the device.
9.Add the specified amount of refined salt. If excessive salt is added, please stop the
machine and wash the cup body with water.
10.When the machine is running, pressure is automatically generated in the container,
please do not give too much impact pressure. It is safer to press 1 to 10 times
depending on the volume of water.
11. Do not put flammable substances around the product.
12. Stop using the container if it is damaged. There is a risk of explosion.
13.Please use unpolluted water and refined salt. The water temperature should not
exceed 50 ° C. This leads to a malfunction.
14. Do not wash the outside of the container with water. The main unit is not
waterproof.
15.If the pressure is too high, do not open the cover directly, turn the product over
first and press. The spray button relieves the pressure on the container before opening
the lid.
16. Do not drink the original solution directly.
17.If the product has noises, smells and smoke, please pull out the power plug in good
time and contact customer service.
WARNING
To avoid fire, electric shock, and injury, you must meet the following requirements.
Otherwise, please follow the respective national and local electricity regulations
Other manuals for SKJ-CRS01
2
Table of contents
Other ULTTY Portable Generator manuals
Popular Portable Generator manuals by other brands

Honeywell
Honeywell HW7000EH owner's manual

Nidec
Nidec LEROY-SOMER LSA 44.3 Installation and Maintenance

Telair
Telair ENERGY 4004D Use and maintenance manual and instructions for installation

Mosa
Mosa YANMAR Use and maintenance manual

Northern Lights
Northern Lights PX-300K2 Series A.C. Generators Operator's & parts manual

Sole Diesel
Sole Diesel 165 GT Operator's manual