ULTTY SKJ-CRS01 User manual

Instruction Manual
Household Disinfectant Generator
SKJ-CRS01
Please read this manual before using

④
②
①
③
⑤
⑥
⑦
⑧
⑨
⑩
⑥ Cup body
⑤ Max water level
⑧ Touch button⑦ Electrode net
④ Air inlet
② Spray nozzle① Air pressure handle ③ Straw
⑨ Spray button
⑩ Handle Power connection hole
Assembly

Product Name:Household Disinfectant Generator
Model Name:SKJ-CRS01
Operating voltage / frequency:AC100-240V~50/60Hz
Function mode:Beauty / disinfection / washing mode
Nominal voltage:12V
Rated power:26W
The SKJ-CRS01 Household Disinfectant Maker is a safe
smart device designed to make 100% natural, non-toxic
and broad-spectrum disinfectant at home. With a simple
solution of salt and water, and a bit of power, the device
makes medical NaClO disinfectant. NaClO disinfectant
kills 99.99% of germs on hard, nonporous, nonfood
contact surfaces by soak, wipe, spray. Kills E. coli,
Staphylococcus aureus, Candida albicans, polio virus, etc.
of NaClO disinfectant. Electrolysis the salt water to make
the NaClO disinfectant.
The principle is the same as common industrial production
Accessory: host, power supply, spoon, operating instructions
Weight:520g
Sterilization rate:99.99%
lifespan:≥3000h
Features

Touch button
Disinfectant manufacturing,Keep the lid open.
1.Connect the power, the machine turn to standby, the blue
LED of the cup body turn on, after the blue light is off, click the
touch button to select the corresponding mode.
2.Click to select and start the mode directly.
a.Click once select the Beauty Mode, blue LED flicker once,
machine auto start.
b.Click twice in 3s select the Disinfectant Mode, blue LED flicker
twice, machine auto start.
c.Click thrice in 3s select Wash-water Mode, blue LED flicker
thrice, machine auto start.
No operation in 3s, the machine start working and the blue LED
will stay on. In working state you can disconnect the power and
stop the machine.
3.Working time: 3 minutes in Beauty Mode and Disinfection
Mode, 10 minutes in Wash-water Mode.
4.After work finished, the blue LED go off and the machine turn
to standby.
Operating

1. Add water do not
exceed the maximum
line (330ml).
2. Add salt,
1 spoon ~ 2 g
3. Stir or shake 30-60s. 4. Switch on and select
work mode.
Instructions

Instructions
6. Blue LED goes out,
disinfectant ready.
5. The blue LED lights up
and is working. (Attention:
electrolysis with open lid).
8. Adjust spraying
Increase air pressure.
7. Tighten the cap
clockwise.
Open the lid

Instructions
Wipe, soak, rinse and disinfect the surface
of various clean objects.
Wipe, soak, rinse, and spray disinfect the
surface of various non-clean objects.
Immersed and disinfected the cleaned
tableware; washed out after disinfection.
Disinfecting the cleaned tableware used
by patients with infectious disease;
washed out after disinfection.
Disinfecting the non-cleaned tableware
used by patients with infectious diseases;
washed out after disinfection.
Immersed and disinfected the fabric;
washed out after disinfection.
Concentration, Time required to kill various microorganisms
Effect
Kill E. coli, Staphylococcus aureus≥99.99%
Kill Pseudomonas aeruginosa≥99.999%
Kill Candida albicans≥99.99%
Kill Poliovirus-I vaccine strain≥99.99%
Kill Bacillus subtilis spores≥99.99%
Target
Concentration
(mg/L)
Duration
(min)
General
surface
100 250~
400 700~
10 30~
10~30
Tableware
Sanitary Standards for
Tableware Disinfection
400 20
500~800 30
20250~400
Fabric
Concentration
(mg/l)
Duration
(min)
100 10
200 10
200 20
500 60
Reference

330ml 3 minutes
330ml
Salt
2g
330ml
Salt
2g
Tap Water
Tap Water
Tap Water
No Salt
3 minutes
10minutes
Disinfectant Mode
Beauty Mode
Wash-water Mode
Working Mode

Disinfectant Mode
330ml Tap Water + 2g Salt, shake the cup 30-60s to fully
dissolve the salt. Run 3 minutes to make NaClO
disinfectant concentration ≥200mg / L
Function: Spraying or soaking, for cleaning,
decontaminating, sterilizing.
Suitable for toothbrushes, dentures, pet supplies, toys,
air conditioners, shoe cabinets, bath towels, bedding,
and various kitchen supplies.
Wash-water Mode
330ml Tap Water + 2g Salt, shake the cup 30-60s to fully
dissolve the salt. Run 10 minutes to make NaClO
disinfectant concentration ≥500mg / L
Function: Spray, soak or wipe with a towel, for sterilizing,
deodorizing, bleaching and washing the items.
Suitable for underwear, toilet, bathroom, trash can,
hospital, sewer, and the place where mold is breeding.
Beauty Mode
Electrolysis the pure tap water , 3 minutes. (no salt!)
Function: effective removing chemicals and impurities,
make extremely clean alkaline water(PH≈7.5).
Its function is equivalent to basic cosmetic water.
Function Description

1. The water and disinfectant produced by this machine is for
external. Do not drink and placed in a place where children
can not reach;
2. Operate the machine in accordance with the manual;
3. Do not perform other operations during the generation
process to avoid damage to the equipment;
4. During the working process, it is normal for yellow willow-
like precipitates to appear in the solution. This is because the
water is rich in iron ions, and the above phenomenon will also
occur when using table salt containing potassium
ferrocyanide;
5. Please use the generated disinfectant in time, otherwise the
concentration of disinfectant will decrease due to the
influence of light and temperature, and the residence time of
disinfectant in the cup should be reduced to extend the
service life of the equipment.
6. Use the generated disinfectant as much as possible on the
spot. Excess glass or plastic bottles should be sealed from
light, dark and dry place and well-ventilated clean room, and
the storage time should not be too long.
7. Sodium hypochlorite disinfectant is corrosive to metals. Use
with caution.
8. It is forbidden to use disinfectant to sterilize and sterilize
textiles woven with natural fibers other than white to prevent
discoloration.
9. Do not use with alcohol, vinegar, toilet spirit, or concentrated
sulfuric acid at the same time.
10. Disinfectant can be used to clean the humidifier, but it is not
recommended to keep it in the humidifier water tank.
11. When not in use for a long time, open the cup cover, store it
upside down, and dry it.
Notes

WARNING
To avoid fire, electric shock, and injury, you must meet
the following requirements. Otherwise, please follow
the respective national and local electricity regulations
1.Children, the elderly and people with disabilities or without
experience should be looked after by a responsible person
when using this product. Children should be supervised to
ensure that they are not playing with the machine as a toy.
2.Please use a separate outlet according to the current / voltage
of the device. Do not use a multi-purpose socket for
simultaneous use with other electrical devices.
3.If the machine does not work due to a damaged power cord,
switch off the power supply and ask a qualified person for
repair.
4. Do not pull out the plug by the cable. Pull out the plug and do
not grip the cable.
5. Do not stretch or energize the cable. Keep the cable away from
the heat source.
6.Turn off all controls before pulling the plug and pull the plug
out of the socket if you are not going to use the device for a long
time.
7. Do not immerse the machine, power cord or plug in water or
other liquids to avoid danger. The use of an extension cord is
not recommended unless it has been tested by a qualified
person.
Safety Instructions

8. Please do not use an air cleaner or similar product directly
next to the machine. Do not use detergents or lubricants for
this machine and pull the power plug before cleaning,
transporting and servicing the device.
9.Add the specified amount of refined salt. If excessive salt is
added, please stop the machine and wash the cup body with
water.
10.When the machine is running, pressure is automatically
generated in the container, please do not give too much
impact pressure. It is safer to press 1 to 10 times depending
on the volume of water.
11. Do not put flammable substances around the product.
12. Stop using the container if it is damaged. There is a risk of
explosion.
13.Please use unpolluted water and refined salt. The water
temperature should not exceed 50 ° C. This leads to a
malfunction.
14. Do not wash the outside of the container with water. The
main unit is not waterproof.
15.If the pressure is too high, do not open the cover directly,
turn the product over first and press. The spray button
relieves the pressure on the container before opening the lid.
16. Do not drink the original solution directly.
17.If the product has noises, smells and smoke, please pull out
the power plug in good time and contact customer service.

Manuel d’instruction
Générateur de Désinfectant Domestique
SKJ-CRS01
Veuillez le lire et le conserver avant d'utiliser le produit

④
②
①
③
⑤
⑥
⑦
⑧
⑨
⑩
⑥ Corps de coupe
⑤ Niveau d'eau maximum
⑧ Bouton tactile⑦ Filet d'électrode
④ Entrée d'air
②Buse de pulvérisation① Poignée de pression ③ Paille
⑨ Bouton de pulvérisation
⑩ Poignée Trou de connexion d'alimentation
Description du produit

Nom du produit:Générateur de désinfectant domestique
Modèle du produit:SKJ-CRS01
Frèquence nominale:AC100-240V~50/60Hz
Mode de fonctionnement:Beauté/Désinfectant/Lavage
Tension nominale:12V
Puissance nominale:26W
Générateur de désinfectant domestique SKJ-CRS01 est un
appareil inteillgent sûr qui eat conçu pour fabriquer le
désinfectant 100% naturel, non toxique et à large spectre
à la maison. Utilisez du sel et de l'eau ordinaires comme
matières premières pour faire du désinfectant NaClO, soit
le désinfectant hypochlorite de sodium. Le désinfectant
NaClO peut tuer 99,99% des bactéries à la surface de l'objet
par trempage, essuyage, et pulvérisation telles que E. coli,
Staphylococcus aureus, Candida albicans, poliovirus, etc.
production industrielle. Électrolyser du sel et de l'eau pour
faire le désinfectant hypochlorite de sodium.
Le principe est le même que celui du désinfectant de
Composition: Hôte, Chargeur, Cuillère, Manuel
Poids net:520g
Taux de stérilisation:99.99%
Caractéristiques
Paramètres de base
Durée de vie:≥3000h

1. Connectez l’alimentation, la machine se met en mode veille,
la LED bleue du corps de coupe est toujours allumée. Une fois la
lumière bleue éteinte, cliquez sur le bouton tactile pour
sélectionner le mode de fonctionnement.
2. Appuyez sur le bouton tactile pour sélectionner et démarrer
le mode directement.
a. Appuyez sur le bouton tactile une fois pour sélectionner le mode
de beauté, la LED bleue du corps de coupe clignote une fois.
b. Appuyez sur le bouton tactile deux fois en trois secondes pour
sélectionner le mode de désinfectant, la LED bleue du corps de
coupe clignote deux fois.
c. Appuyez sur le bouton tactile deux fois en trois secondes pour
sélectionner le mode de lavage, la LED bleue du corps de coupe
clignote trois fois.
Aucune d’autre opération en trois secondes, la machine
commence à fonctionner et la LED bleue reste allumée.
En état de fonctionnement, vous pouvez couper l'alimentation
et arrêter la machine.
3. Durée de fonctionnement : Trois minutes en mode de beauté et
mode de désinfectant, dix minutes en mode de lavage.
4. Une fois le travail terminé, la LED bleue s’éteint et la machine
se met en veille.
Fonctionnement

1. Lors du chargement de l'eau,
ne pas dépasser la ligne de
niveau d'eau maximum (330 ml)
2. Metter du sel selon le mode
de fonctionnement
1 cuillère≈2g
3.
machine 30-60s.
Remuer ou secouer la 4. Appuyer sur le bouton pour
sélectionner le mode.
Instructions

Instructions
6. La LED bleue reste allumée
pendant le travail.
5. Ouvrez le couvercle
pendant l'électrolyse.
8. Augmenter la poignée de
pression d'air
Ajuster la buse de pulvérisation
7. L'eau de désinfectant
prêt, la LED bleue éteinte.
Open the lid

Instruction
Essuyer, faire tremper, rincer et désinfecter
la surface de divers objets propres.
Essuyer, tremper, rincer et désinfecter par
pulvérisation la surface de divers objets non propres.
Immerger et désinfecter la vaisselle;
lavé après désinfection.
Désinfecter la vaisselle utilisée par les
patients maladies infectieuses nettoyée
(≥20 min); lavé après désinfection.
Désinfecter la vaisselle non nettoyée utilisée
par les patients maladies infectieuses;
lavé après désinfection.
Plonger et désinfecter le tissu;
lavé après désinfection.
Concentration, Durée de fonctionnement pour stériliser divers micro-organismes
Effect
Stériliser E. coli, Staphylococcus aureus≥99.99%
Stériliser Pseudomonas aeruginosa≥99.99%
Stériliser Candida albicans≥99.99%
Stériliser Poliovirus-I vaccine strain≥99.99%
Stériliser Spores de bacillus subtilis≥99.99%
Champ
d'application
Concentration
(mg/L)
Durée de
fonctionnement
(min)
Surface de
l'objet
général
100 250~
400 700~
10 30~
10~30
Vaisselle
Normes sanitaires pour la
désinfection de la vaisselle
400 20
500~800 30
20250~400
Tissu
Concentration
(mg/l)
Durée de
fonctionnement
(min)
100 10
200 10
200 20
500 60
Référence

330ml
330ml
Sel
2g
L'eau
Pas de sel
Mode de désinfectant
Mode de beauté
Mode de lavage
Mode de fonctionnement
3 minutes
330ml
Sel
2g
3 minutes
10minutes
L'eau
L'eau
Other manuals for SKJ-CRS01
2
Table of contents
Languages:
Other ULTTY Portable Generator manuals
Popular Portable Generator manuals by other brands

GENMAX
GENMAX GM6000iED Maintenance and operation instructions

Generac Power Systems
Generac Power Systems 86640 Service manual

Soga
Soga sincro FK Series Use and maintenance manual

Monster Group
Monster Group T-MECH 210410 instruction manual

LEGRAND
LEGRAND 035 64 quick start guide

Generac Power Systems
Generac Power Systems iQ3500 owner's manual

Rohde & Schwarz
Rohde & Schwarz SMIQ03HD operating manual

K&S
K&S KS 2900 instructions

Tycon Power Systems
Tycon Power Systems TP-MS608 user manual

DUROMAX
DUROMAX XP4400EH user manual

Rittal
Rittal CMC III Installation guide and short user's guide

Waterworks
Waterworks WWSU08 Installation and service instructions