manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Uni-Trend
  6. •
  7. Security Sensor
  8. •
  9. Uni-Trend UT12B User manual

Uni-Trend UT12B User manual

87%⌟⬉ヨ
Փ⫼䇈ᯢк
Ўњ䙓ܡ㾺⬉៪Ҏ䑿Ӹᆇˈ䇋⊼ᛣҹϟџ乍˖
!བᵰ⌟⬉ヨᏆ㒣ᤳണˈ៪㗙⌟⬉ヨ᮴⊩ℷᐌ᪡
԰ˈ䇋࣓Փ⫼DŽ
㢹᳝⭥䯂ˈ䇋ᇚ⌟⬉ヨ䗕ׂDŽ
!䇋࣓ᮑࡴ䍙䖛⌟⬉ヨϞ󰵼䆄ⱘ乱ᅮ⬉DŽ
!9˄Ѹ⌕˅ҹϞⱘ⬉ৃ㛑ᄬ೼㾺⬉䰽ˈ᪡
԰ᯊᑨḐ໪⬭ᛣDŽ
!ᑨ䙉ᅜᔧഄ᠔೼೑ᆊⱘᅝܼ㾘㣗DŽ
䞡㽕ֵᙃ˖
ঠ䞡㒱㓬DŽ
ᇣᖗˈ᳝⬉ߏⱘ䰽DŽ
᳝䰽ˈ䞡㽕ֵᙃˈখ㗗᠟ݠDŽ
&$7,9䆒໛ᮼ೼ֱᡸܡফϔ㑻⬉⑤ㄝ㑻བ⬉㸼៪催
ぎ㒓䏃៪ഄϟ㒓䏃䆒ᮑѻ⫳ⱘⶀ䯈⬉ⱘᤳᆇDŽ
ᴀકヺড়/9'˖˄(1˖
(0&˖˄(1˖$˖
$˖$˖˅
⊼ᛣ
Փ⫼ᯊ᠟ᣛއϡ㛑䖯ܹヨ䑿ࠡ䚼ⱘⱑ㡆䚼ߚ
ϔǃᎹ԰⬉ঞᎹ԰ᴵӊ˖
Ꮉ԰⬉Ў9$&
Ꮉ԰ᴵӊ⏽ᑺ˖~ćˈᄬᬒ˖~ćˈ
⑓ᑺ˖İˈ ⍋ᢨ˖P
⏙⋕˖⫼⑓Ꮧ⏙⋕DŽ
Ѡǃ᪡԰ᣛ⼎˖
!⌟⬉ヨࡼ
䕏䕏ᣝϔϟ󰵼᳝⬉⑤ヺোⱘᣝ䪂ˈ㳖号఼ડϸ
ໄ/('䖲䮾ϸ󱂖ˈ㸼⼎⌟⬉ヨ៤ࡳࡼDŽ䖯ܹᕙ
⌟⢊ᗕ/('Ӯ↣䯈䱨⾦䖲㓁䮾⚕ϸ󱂖DŽ
!Ѹ⌕⬉Ẕ⌟
ᇚ⌟⬉ヨⱘ᥶༈䴴䖥ᏺ᳝Ѹ⌕⬉ⱘ㹿⌟⠽ԧˈ
/('䮾⚕ৠᯊ㳖号DŽ
ϝǃ⬉∴⬉䞣ϡ䎇ᦤ⼎
ᔧ⬉∴⬉ԢѢ9ᯊᓔᴎ⌟䆩ᯊ/('ഛϡӮ⚍
҂Ԛֵ᳝োᯊ㳖号఼ৃ㛑Ӯ᳝䕗ᖂᔅⱘડໄDŽ
ಯǃ⬉∴᳈ᤶ˖
⬉∴[9$$$
䇋খ㗗೒⼎
ϔ᠟ᦵԣヨ䑿ˈ঺ϔা᠟ⱘ໻ᢛᣛԣヨ༈ⱘ
ԡˈৠᯊৢᢝヨ༈ˈབϞ೒᠔⼎DŽ
䇋乎ⴔ೒⼎ⱘᮍ৥ᡞ⌟⬉ヨⱘϞⲪᢑߎˈᡞᮻ⬉
∴᳈ᤶᥝৃDŽ
!㞾ࡼ݇䯁⬉⑤
བᵰ໻㑺ߚ䩳ϡՓ⫼⌟⬉ヨˈЎ㡖ⳕ⬉∴Ӯ㞾
ࡼ݇䯁⬉⑤DŽ䖲㓁ϸໄⷁ㳖号ˈ᥹ⴔϔໄ䭓㳖
号ˈ㸼⼎݇ᴎ៤ࡳDŽ
!ذ⫼㳖号఼
ᓔᴎৢݡ󱂖䕏ᣝϔϟᣝ䪂ˈϔໄ㳖号ৢ㸼⼎Ꮖ㒣
݇ᥝ㳖号఼ˈᔧ⌟䆩ࠄֵোৢϡݡ㳖号ˈা᳝
/('䮾⚕DŽ䖭⾡ᮍᓣӮ໻໻ⱘ㡖ⳕ⬉∴DŽ˄㳖号
఼᡹䄺ذ⫼㳖号ᓔᴎৢৃҹ⫼ᣝ䪂ⳌѦߛᤶ˅
!݇䯁⌟⬉ヨ
䭓ᣝᣝ䪂⾦⌟⬉ヨӮ݇ᴎˈ݇ᴎᯊӮԈ᳝ϔ⾦
ⱘ䭓㳖号DŽ
೒Ѡ
೒ϔ
䄺
!ℸ䆒໛ҙկ᳝ϔᅮϧϮⶹ䆚ⱘҎՓ⫼˗
!ℸ䆒໛ҙ⫼Ѣ߸ᅮᇐԧᰃ৺ᏺ⬉ˈᛳᑨ㣗ೈ
Ў9Ѹ⌕⬉ˈẔ⌟ࠡ䇋ܜ߸ᮁᏺ⬉ԧ
ৃ㛑ⱘ⬉㣗ೈ˗
!ᇍѢϡ㛑⹂ᅮ⬉㣗ೈⱘᇐԧˈ⌟⬉ヨ≵᳝
ডᑨᑊϡ㸼⼎ᇐԧϔᅮϡᄬ೼䰽⬉ˈ䇋
ϡ㽕⫼䑿ԧⱘӏԩ䚼ԡএ᥹㾺ᇐԧDŽ
PN/:110401103943
UT12B
Voltage Detector
Double Insulated
Warning. Refer to the Operating Manual
Danger of electric shock
Conforms to Standards of European Union
This Operating Manual covers information on safety
and cautions. Read and understand all of the
instructions and safety information in this manual
before operating or servicing this tool. Failure to
understand how to safely operate this tool could
result in an accident causing serious injury or death.
Figure 1
Figure 2
Overview
UT12B is intended to check for the presence of
AC voltage, signaling the user with a beep and a
flashing LED.
Do not use the unit if it is wet, damaged or
cannot operate correctly.
Do not apply more than the rated voltage
between the probe tip and earth ground.
When the unit working at voltage over 30V in
AC, special care should be taken for there is
danger of electric shock.
Follow the local countries safety requirements
and standards.
Warning
This unit is only designed for the specialist
who has certain technical knowledge to use.
This unit is intended to check for the presence
of AC voltage, the voltage range is 90~1000V.
Make sure the tested inductor possible
voltage range before carrying out checking.
When you cannot sure the tested inductor
voltage range, the unit does not have any
response. It does not mean the tested inductor
does not have dangerous voltage, do not use
any part of the body to touch the tested
inductor.
When carrying out checking, keep your fingers
behind the probe tip finger guards.
Pollution Degree 2
Battery: 2 x 1.5V AAA
Operation
1)
2)
3)
4)
5)
Battery Indication
The LED will not flash when you turn the unit on or
during checking if the battery is less than 2V. The
beep sounds will still have but may be weaker.
Safety Information
This unit complies with the standards
EN61010-1, UL61010-1 and CASC 22.1
No. 61010-1 safety measurement requirement:
in pollution degree 2, overvoltage category
(CAT. IV 1000V)
Maintenance
1) Disconnect the unit from the circuit.
2) One hand holds the unit. Place another hand’s
thumb on the probe cap as the figure below
3) Pull back the back housing as the figure below
4) Replace the batteries (observe polarity).
2 x1.5V AAA
5) Push back the back housing.
Periodically wipe the case with a damp cloth and
mild detergent; do not use abrasives or solvents.
International Electrical Symbols
Symbols used on the Meter and in this manual are
explained below:
CAT.IV: Primary supply level, overhead lines, cable
systems etc. Some examples include cables,
meters, transformers, and other exterior equipment
owned by the power utility.
Use the unit only as specified in this operating
manual, otherwise the protection provided by the
unit may be impaired.
Specifications
Indicators: LED and Beep
Voltage range: 90VAC ~ 1000VAC
Measurement Category IV 1000V per IEC61010
Temperature:
Operating: -10~50
Storage: 10~50
Humidity: 95%
Altitude: 2000m
Turn the unit on by pressing the power button
once, the unit beeps and LED flashes two times.
When the unit is under standby mode, the LED
keeps flashing two times in every 1.5 seconds.
Place the probe tip on or near the circuit or unit
to be tested. Beep and flashing LED indicate
the presence of voltage (90VAC to 1000VAC).
To turn off the beeper, you could press the
power button once after turning on the unit,
then you will hear a beep sound indicating the
beeper is off. After the beeper is off, only LED
will flash during checking. This way could save
battery.
Press power button to toggle between beeper
mode and silent mode. Beep two times enters
beeper mode, while beep one time enters silent
mode.
In order to save battery, the unit will auto power
off when it is not used for around 3 minutes.
The beeper sounds 2 times continuously and
then one long beep means the unit is power
off.
Press and hold the power button for two
seconds to turn the unit off, there will be one
second long beep.
Copyright 2007 Uni-Trend Group Limited.
All rights reserved.
This operating manual is subject to change
without notice.
*END*
¾
¾

Popular Security Sensor manuals by other brands

SimpleSafe SSCO3-0 user manual

SimpleSafe

SimpleSafe SSCO3-0 user manual

Frick WVS-1000 DAQ quick start guide

Frick

Frick WVS-1000 DAQ quick start guide

Infinite L-com SRCN-C413-2 user guide

Infinite

Infinite L-com SRCN-C413-2 user guide

Sperian MILLER SCORPION 1016840 user manual

Sperian

Sperian MILLER SCORPION 1016840 user manual

Optex CX-702RS installation instructions

Optex

Optex CX-702RS installation instructions

LST 2100RFT-AS Specification sheet

LST

LST 2100RFT-AS Specification sheet

Bacharach H-10PA manual

Bacharach

Bacharach H-10PA manual

SGB DL Series manual

SGB

SGB DL Series manual

Evikon PluraSens E2648-ETO user manual

Evikon

Evikon PluraSens E2648-ETO user manual

Det-Tronics X3302 instructions

Det-Tronics

Det-Tronics X3302 instructions

Xintex P-1BS-R Owner's Manual & Installation Instructions

Xintex

Xintex P-1BS-R Owner's Manual & Installation Instructions

Aritech DDV1016 Installation sheet

Aritech

Aritech DDV1016 Installation sheet

Lince GR868 Bobby Technical manual

Lince

Lince GR868 Bobby Technical manual

Niko 351-25000 manual

Niko

Niko 351-25000 manual

Pepperl+Fuchs NBN8-18GS50-Z4L-V1-3G-3D instruction manual

Pepperl+Fuchs

Pepperl+Fuchs NBN8-18GS50-Z4L-V1-3G-3D instruction manual

EnOcean EASYFIT EOSD installation guide

EnOcean

EnOcean EASYFIT EOSD installation guide

BEMKO SES24WH user manual

BEMKO

BEMKO SES24WH user manual

DMP Electronics 1126 Series Installation sheet

DMP Electronics

DMP Electronics 1126 Series Installation sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.