UniPOS FS5200R User manual

UniPOS Repeater FS5200R
Instruction Manual Page1
Revision 3/01.17 of 48
REPEATER FS5200R
OPERATION MANUAL

UniPOS Repeater FS5200R
Instruction Manual Page 2
Revision 3/01.17 of 48
CONTENTS
1. Introduction........................................................................................................................3
2. Function.............................................................................................................................3
3. Technical data....................................................................................................................3
4. Contents of delivery ...........................................................................................................4
5. General information ...........................................................................................................5
6. Duty Mode .........................................................................................................................9
7. Fire condition...................................................................................................................10
8. Fault Condition.................................................................................................................13
9. Disabled Component........................................................................................................17
10. Information and Control Mode........................................................................................19
11. Labour protection requirements......................................................................................35
12. Installation......................................................................................................................36
13. Repeater start up...........................................................................................................41
14. Conditions of operation, storage and transportation.......................................................42
15. Warranty........................................................................................................................42
16. Appendix 1.....................................................................................................................43

UniPOS Repeater FS5200R
Instruction Manual Page 3
Revision 3/01.17 of 48
1. Introduction
Repeater FS5200R is a unit supplementing the range of 5000 series products expanding the
possibilities of the fire detecting and fire extinguishing systems built on the basis of fire control
panels FS5100, FS5200, FS5200E and FS4000.
Some of its main features and possibilities are:
Indicates Fire condition and/or Fault condition occurred in each of the fire control panels
connected to it;
control effect on the connected fire control panels that have sent a signal for Fire
condition;
user oriented menu dialogue for easy and convenient operation;
four-line LCD for visualization the different modes of the repeater;
LEDs and sound indication of the operation modes;
user oriented test modes allowing for a total control of the site protected;
energy independent archive memory saving the event type, date and time,;
2. Function
Repeater FS5200R:
- receives data for Fire condition from the remote fire control panels:
- receives data for Fault condition from the remote fire control panels:
- displays information for the condition of remote fire control panels;
- executes control commands to lines of remote fire control panels for their forced exit of Fire
condition;
Repeater FS5200R could be used:
- when the persons whom are expected to detect and react initially to the fire condition
and/or fault condition signals are at a different place from the location of the fire control
panel/s;
- when fire control panels located at different sites have to be monitored and controlled
from one place;
- when the fire control panel/s are monitored from several locations.
It is compatible with FS4000, FS 5100, FS 5200, FS 5200E and FS5200R.
3. Technical data
3.1. Functional characteristics
-Connection of maximum 15 remote fire control panels (repeaters) to one
repeater;
Built-in sounder for fire condition –one tonal, discontinuous, can be switched
off
Built-in sounder for fault condition –one tonal, discontinuous, can be switched
off

UniPOS Repeater FS5200R
Instruction Manual Page 4
Revision 3/01.17 of 48
Built-in real time clock
-Interfaces for communication with the fire control panels RS485 connected to it;
-Option to prolong the time period for Fire condition stage I with programmable
inspection period
-Possibility for delay when switching the outputs for Fire alarm;
-Energy independent archive –up to 100 events;
-Operation with a wide range of output devices;
3.2. Indications of registered events
-Light indication –LED
-Text messages –LCD display, 4 lines 20 characters per line, Cyrillic letters
-Sound signaling –built-in sounder
3.3. Monitored outputs
type –potential
electrical characteristics - (245)V DC / 1A
3.4. Relay output for general function
type –potential free, switching
electrical characteristics –3A/125ADC; 3A/30VDC
3.5. Relay output for fault condition
type –potential free, switching
electrical characteristics –3A/125ADC; 3A/30VDC
3.6. Power supply
3.6.1. Mains
voltage –220/230 VAC
frequency –50 Hz
3.6.2. Back up batteries
battery type –lead, gel electrolyte
number of batteries –2 pcs
connection –consecutive
nominal voltage of the connected back up batteries –24 V DC
nominal capacity С20 –(1,2 –4,5) Ah
extreme discharge voltage –17,6V
charge voltage –28V
3.6.3. Fuses
mains 220/230 V –4,0 А
back up batteries –2,0 А
3.7. Dimensions and weight of the unit
dimensions –313 х 218 х 85 mm
weight (batteries not included) –1,6 kg
4. Contents of delivery
Repeater FS5200R - 1 pc
Resistor 5,6 k- 2 pcs
Jumper for backup batteries - 1 pc

UniPOS Repeater FS5200R
Instruction Manual Page 5
Revision 3/01.17 of 48
Fuse 4А - 1 pc
Fuse 2А - 1 pc
Instruction manual - 1 pc
Instructions for authorized staff - 1 pc
Packing - 1 pc
5. General information
5.1. Access levels
Four access levels are available in the repeater:
5.1.1. Access Levels 1 and 2
All persons who would presumably find out and react to alarm upon fault condition or fire
condition have access to level 1 and 2. They shall be trained and authorized to operate the
repeater in the following conditions: Duty Mode, Fault condition; Disabled component and
System functions (except SetUp).
The following actions are accessible:
Displaying suppressed messages for Fire condition, Fault condition, Disabled
components and Zone in test
Forced proceeding from phase Fire condition stage I to phase Fire condition stage II
Suppressing the local sounder
Displaying the status of the connected fire control panels and repeaters;
Switching off the outputs, activated upon fire condition;
Exit of Fire condition; SetUp Mode
System functions of the fire control panel, except
5.1.2. Access Level 3
To access this level:
-unlock and open the front cover of the repeater;
-enter a password.
For the personnel authorized to have Access Level 3, it is available
-all features accessible at Level 1 and 2;
-reconfiguration of specific data of the repeater;
-replacing a burnt fuse;
-connecting executive devices;
-connecting slave fire control panels and repeaters;
-maintenance of the repeater.
5.1.3. Access Level 4
Accessible for personnel trained and authorized by the Producer to repair the repeater and to
modify the software
5.2. Conditions and indication
The repeater FS5200R operates in six basic modes: Duty Mode, Fire Condition, Fault
Condition, Disabled Component Mode, Information and Control Mode and SetUp Mode:

UniPOS Repeater FS5200R
Instruction Manual Page 6
Revision 3/01.17 of 48
Duty Mode - the repeater is in Duty Mode, when the fire control panels connected to it are
not in any of the rest five possible conditions and they have a connection with ;
Fire condition –The repeater enters Fire condition when a fire detector is activated in a
line/lines of the fire control panel connected to it;
Fault condition –the repeater enters this condition when a fault in any of the fire control
panels connected to it is registered or its connection with any of the fire control panels has
been interrupted;
Disabled component - the repeater enters Disabled component after a manual operation,
disabling a certain component has been performed –monitored output;
Information and Control;
SetUp Mode –the repeater enters SetUp Mode after activation of submenu Set up, in
Information and Control Mode;
In any moment the repeater can be in any of the above conditions/modes, or in a random
combination of Fire condition, Fault condition, Disabled component and Information and Control
mode. Duty Mode and SetUp Mode can not be combined with another mode:
the repeater enters Duty Mode after all other conditions are exited;
when the repeater enters SetUp Mode it exits all other conditions.
The conditions of the repeater and their corresponding indication are shown in Table 1.
Conditions of the repeater
Indication
All conditions -
The repeater is power supplied
- indicator Power supply –
continuous green light [12]
- indicator for inspection time (if
programmed) [13]
Fire condition
- common indicator Fire condition -
red light; [19]
- individual LED indicator for the
slave fire control panel (repeater)
[21]
- indicator for inspection time (if
programmed) [13]
- indicator Power supply –
continuous green light [12
Fault condition -
All faults except for Battery Low
- Common indicator Fault condition
–continuous yellow light [1]
- Fault condition in a remote fire
control panel [4]
Fault condition –System error
Indicator System error –
continuous yellow light [2]
Fault condition
Indicator Fault in mains supply of
the remote fire control panel -
continuous yellow light [5]
Fault condition
Common indicator Fault in fire
detecting line of a remote fire
control panel - continuous yellow
light [6]

UniPOS Repeater FS5200R
Instruction Manual Page 7
Revision 3/01.17 of 48
Conditions of the repeater
Indication
Fault condition
Indicator Fault in monitored output
of a remote fire control panel
- continuous yellow light [7]
Fire condition
Local sounder –discontinuous signal: 0.5 s
sound, followed by 0.5s break
Fault condition –
All faults except for Battery Low
Local sounder –discontinuous signal: 1 s
sound, followed by 1 s break
Fault condition -
Low battery
Local sounder –discontinuous signal: 1 s
sound, followed by 3 s break
5.3. Means of control and indication
Means of control
Condition of the repeater
operation
Button Reset
Fire condition
Control operation, to force a line of the
remote fire control panel to exit Fire
condition (reset line) [14]
Button Menu
Duty mode, Fault condition
Information and Control
mode, SetUp mode and Fault
condition
To enter the menu for review, setting up
the repeater [8]
Button Down
Duty mode, Fault condition
Information and Control
mode, SetUp mode and Fault
condition
To display in the text screens the next
message or element of the menu [9]
Button Up
Duty mode, Fault condition
Information and Control
mode, SetUp mode and Fault
condition
To display in the text screens the next
message or element of the menu [10]
Button Exit
Duty mode, Fault condition
Information and Control
mode, SetUp mode and Fault
condition
To exit the menus or to exit SetUp mode
with saving the changes [11]
Button Alarm
Fault condition, Fire condition
To suppress the local sounder [15]
Button Outputs
Fire condition
- Upon activated outputs for fire condition
–to suppress the outputs;
- If no outputs for fire condition are
activated –to activate the suppressed
outputs, if any [17]

UniPOS Repeater FS5200R
Instruction Manual Page 8
Revision 3/01.17 of 48
5.4. Panel for control and indication
LED indicators and buttons are positioned in functional groups, as follows:
Indicators for common fault conditions - [1], [2] and [3];
Indicators for fault conditions in the remote fire control panels (repeaters) –[4], [5], [6]
and [7];
Buttons for control on the LCD display and for entering of parameters –[8], [9], [10]
and [11];
Individual indicators for Fire condition and Fault condition of remote fire control
panels –[21];
Buttons and indicators showing each status of the repeater –[12], [13], [14], [15],
[16], [17], [18] and [19].
1 2 345 6 78 9 10 11 12 13 14 15
1
2
3
4
5
6
7
8 9 10 11 21
13
14
15
16
17
18
19
20
12
Front panel of repeater FS5200R
1 Common indicator for Fault condition
2 Indicator for System error
3 Indicator for Fault in power supply
4 Common indicator for Fault condition in a remote fire control panel
5 Common indicator for Fault in power supply in a remote fire control panel
6 Common indicator for Fault condition in fire detecting line of a remote fire control panel
7 Common indicator for Fault condition in monitored output of a remote fire control panel
8 Buttons Menu
9 Button Down

UniPOS Repeater FS5200R
Instruction Manual Page 9
Revision 3/01.17 of 48
10 Button Up
11 Button Cancel
12 Indicator Power supply
13 Indicator Delay of the outputs for Fire condition of the repeater
14 Button Reset
15 Button Alarm with indicator Suppressed alarm
16 Indicator Suppressed alarm
17 Button Outputs with indicator Suppressed outputs
18 Indicator Suppressed outputs
19 Indicator for Fire stage
20 LCD display (4х20)
21 Individual indicators for Fire condition and Fault condition in the remote fire control
panels.
6. Duty Mode
6.1. Description
The repeater is in Duty Mode when:
-it is not in Fault condition;
-the connected to it remote fire control panels (repeaters) are not in Fire
condition or Fault condition.
6.2. Indication
6.2.1. LED and sound indication
In Duty Mode the green LED indicator (Power supply) and the indicator upon
programmed inspection time of the outputs are activated.
6.2.2. Text message
The display shows:
a message “Fire protect”,
i.e. the fire control panel
is in Duty Mode;
the current local time;
the day of the week;
the current date.
12345678910 11 12 13 14 15
6.2.3. Using the keypad
For all access levels the only active button in Duty Mode is (Menu). Press it and the
repeater enters System Functions status.

UniPOS Repeater FS5200R
Instruction Manual Page 10
Revision 3/01.17 of 48
7. Fire condition
7.1. Description
The repeater enters Fire condition after a fire condition has been activated in any of the
fire control panels or repeaters connected to it.
To exit this condition press button and the line in fire condition shown in the upper field of
the display is reset (section.7.3.3).
7.2. Indication
7.2.1. LED and sound indication
In this condition the following indicators
illuminate:
indicator (Fire) in red light;
the individual indicator for Fire
condition of a remote fire control
panel illuminates in red light;
if the outputs of the repeater for
phase Fire condition are
suppressed by button
(Outputs), the LED indicator of
the button illuminates in
continuous red light;
12345678910 11 12 13 14 15
if the sound signaling is suppressed by button (Alarm), “Аларма”), the LED
indicator of the button illuminates in continuous red light.
7.2.2. Text messages
For this condition the display is
divided into two text field:
the first field displays
information about the first
fire control panel and line
in fire condition;
the second field is used
to show information if
more than one fire control
panel (line) is in fire
condition.
If more than 2 lines are in fire
condition, use the buttons
(down) and (up) to view all lines
01 Fire s1/RP01/Ln02
Remote panel 01
03 Fire s2/RM01/Ln05
Remote panel 02
Serial
number of
the fire
Fire stage:
- Fire stage 1
- Fire stage 2
Remote panel
Line in Fire
(subject of reset)
Name remote
panel
First text field
Second text field
Line in Fire
Upon registration of more than 2 fire conditions,
the display visualizes continuous information about

UniPOS Repeater FS5200R
Instruction Manual Page 11
Revision 3/01.17 of 48
in fire condition at the respective fire
control panels.
the first and the last fire condition (EN54-2).
Only the fire condition displayed in the first
text field could be reset.
7.3. Using the buttons
7.3.1. Button (Alarm)
Press it to:
turn the local sounder off if it is activated for Fire condition or Fault condition;
activate the local sounder if the fire control panel is in Fire condition or Fault condition
and the local sounder has been switched off by a preceding pressing of the same button.
The LED indicator of the button illuminates of the local sounder is switched off for Fire
condition or Fault condition.
Buttons’ operation does not effect an event, Fault condition and it is not cancelled by them.
A signal for a new fault condition/s will trigger the local sounder for Fault condition only.
7.3.2. Button (Outputs)
The button’s operation depends on the current Access level and the condition of the fire
control panel.
Press it to:
Suppress the outputs that have been activated for Fire condition.
Activate the suppressed outputs, if any.
The LED indicator of the button illuminates if there are suppressed outputs for Fire condition.
7.3.3. Button (Line Reset)
The button is used to force the line of the remote fire control panel to exit Fire condition.
The procedure to reset a line in which the remote fire control panel is in Fire condition
includes the following steps:
-Select a line –Using the buttons (Down) and (Up) in
the first text field of the display it is visualized the line which status is
going to be changed The line and the fire control panel shown in the
first text field is considered to the selected one;
-Control action –Pressing the button (Line Reset) has a
controlling action from the repeater to the remote fire control panel in
Fire condition and the line is reset (i.e. the remote fire control panel is
in Duty Mode for that line).
Note: If the remote fire control panel is FS4000 or FS5200E type,
pressing the button (Line Reset) results in forced exit of all lines of
the fire control panel from Fire condition not only of a single line.
The above-described steps (select a line/fire control panel and control action) are repeated
for every line in Fire condition that is being reset.
You can reset lines (fire control panels) in Fire condition from any repeater included in the
system.

UniPOS Repeater FS5200R
Instruction Manual Page 12
Revision 3/01.17 of 48
Example:
It is created a system of 5 fire control panels and two repeaters (Appendix 1)
Signals for Fire conditions in two remote fire control panels are received in the repeaters:
- Fire condition in lines 1 and 2 of the fire control panel in Building 1;
- Fire condition in line 1 of the fire control panel in Warehouse;
The following information is visualized on the display of the repeater.
In the first text field:
01 (the first occurred fire condition);
1с (phase of fire condition);
RP03 (No. of the remote panel in fire condition);
Ln02 (No. of line in fire condition);
Building 1 (user’s text showing where the remote panel
is located (see section 10.4.5.2.4)).
In the second text field:
03 (the last occurred fire condition, in this case the third
one);
1с (fire condition Stage 1);
01 Fire s/RP03/Ln02
Building 1
03 Fire s1/RP05/Ln01
Warehouse
First text field
Second text field
RP5 (the fire condition is in remote panel No. 5)
Ln01 (No. of line in fire condition);
Warehouse (user’s text showing where the remote panel is located (see section 10.4.5.2.4)).
Based on the number of the first and the last fire condition it is evident that during the
time of the fire conditions shown on the display there is another fire condition but its visualizing is
suppressed at the moment. Use the buttons (Down) and (Up) to review the
suppressed messages for fire condition.
Using the buttons (Down) and
(Up) in the first text field you can visualize the data for
the line that has to be reset. This line will be forced to
exit fire condition.
Reset the fire signal transmitted from line 1 of
remote panel 3, located in building 1.
02 Fire s1/RP03/Ln01
Building 1
03 Fire s1/RP05/Ln01
Warehose
First text field
Second text field
Pressing the button (Line Reset) in this screen results in:
-Line 1 from Building 1 exits Fire condition and enters Duty Mode;
-The other two lines in Fire condition are visualized. .

UniPOS Repeater FS5200R
Instruction Manual Page 13
Revision 3/01.17 of 48
Total number of lines in Fire condition –2
First text field:
First occurred fire condition –line 2 in Building 1
Second text field:
Last occurred fire condition –line 1 in Warehouse.
Note: There are no suppressed messages for fire
conditions.
01 FIre s1/RP03/Ln02
Building 1
02 Fire s1/RP05/Ln01
Warehouse
First text field
Second text field
After a confirmation is received from the remote fire control panels (up to 10 seconds) that
their lines have been reset and are not in Fire condition, the repeaters enter Duty Mode. If during
Fire Condition the menus are manipulated, it is not possible the Fire condition to be reset.
Attention!
The remote fire control lines are reset only after a check is performed for false
activation. The control action of the repeaters will switch off the activated outputs of the
remote fire control panels for fire condition.
7.3.4. Button (Menu)
Press the button to enter Information and Control Mode.
7.3.5. Button (Exit)
Press it to return to the main screen.
8. Fault Condition
8.1. Description
The repeater enters Fault condition when a fault is registered in:
the repeater;
the remote fire control panels (repeaters) connected to it.
It is accessible at all Access levels.
8.1.1. The repeater enters Fault Condition when any of the events below have been
registered:
Battery low - backup batteries discharged due to interruption of mains supply;
Fault in a processor program;
Fault in a monitored output –short circuit or break;
Fault in the mains supply;
Fault in the backup batteries supply;
Short circuited ground wire;
Fault in external devices supply.
8.1.2. The repeater enters Fault Condition when any of the events below have been registered in
remote fire control panels, too:

UniPOS Repeater FS5200R
Instruction Manual Page 14
Revision 3/01.17 of 48
Battery low - backup batteries discharged due to interruption of mains supply;
Fault in a processor program;
Fault in a monitored output –short circuit or break;
Fault in the mains supply;
Fault in the backup batteries supply;
Fault in a line –removed fire detector, short circuit or break;
Short circuited ground wire;
Fault in external devices supply
In any fault condition of the remote fire control panel with its specific functions.
In Fault condition text messages showing the type of the fault appear on the LCD display.
Additional information is provided by LEDs indicators.
8.2. Indication
8.2.1. LED and sound indication
Upon Low battery fault condition no LED indicator is illuminated. The local sounder produces
discontinuous signal (1 s sound, followed by 3 s break). The lighting of the LCD display is off.
All other fault conditions in the
repeater are designated by indicator
pos. 1 (Fault) illuminating in
flashing yellow light. Depending on the
specific fault, the following indicators
are illuminated too:
upon System error - indicator
pos. 2 (System error) in
continuous yellow light;
pos. 3 (Fault in mains
supply) in continuous yellow
light;
12345678910 11 12 13 14 15
For any fault condition in the remote fire control panels, indicator pos. 4 (Fault)
illuminates in flashing yellow light. Depending on the specific fault, the following indicators are
illuminated too:
pos. 5 (Fault in mains supply) in continuous yellow light.
pos. 6 (Fault in a fire detecting line of a remote fire control panel) in continuous yellow
light;
pos. 7 (Fault in a monitored output of a remote fire control panel) in continuous yellow
light;
The individual indicator for a Fault condition in a remote fire control panel illuminates in
yellow light.
If the sound indication is suppressed by button (Alarm), the LED indicator of button
illuminates in red light.

UniPOS Repeater FS5200R
Instruction Manual Page 15
Revision 3/01.17 of 48
8.2.2. Text messages
Upon registration of a fault/s
condition the LCD display provides
information about:
The total number of fault
events;
Type of the fault event
Control panel in fault
condition
The information on fault
conditions is displayed only if the
repeater is not in fire condition.
Duty mode 11:02.59
Flt:05 Flt.Battery MP
Mode
Fault type
Real time clock
Total number of
faults Panel in
Fault
The most frequently indicated fault conditions in the repeater are:
Text message
meaning
FaultMainsRP
Fault in mains supply of remote panel No. ... (slave fire control panel
or repeater)
FaultLnRP
Fault in a line of remote panel No. ... (slave fire control panel or
repeater)
FaultMOutRP
Fault in a monitored output of remote panel No. ... (slave fire control
panel or repeater)
FaultRP
Fault in remote panel No. ... (slave fire control panel or repeater)
FaultEartRP
Fault in earthing of remote panel No. ... (slave fire control panel or
repeater)
FaultFsMP
Fault in a fuse on the main panel (repeater)
FaultMOut2ShortMP
Short circuit in monitored output 2 of the main panel (repeater)
FaultMOut2BreakMP
Break in monitored output 2 of the main panel (repeater)
FaultMOut1ShortMP
Short circuit in monitored output 1 of the main panel (repeater)
FaultMOut1BreakMP
Break in monitored output 1 of the main panel (repeater)
FaultErthMP
Fault in earthing of the main panel (repeater)
FaultBatMP
Fault in battery back up of the main panel (repeater)
FaultMSMP
Fault in mains supply of the main panel (repeater)
8.3. Using the buttons
For fault conditions 2 active buttons are being supported. Where the fire control panel
operates in combination of other conditions, their buttons are active too.
8.3.1. Button (Alarm)
Press it to:
switch the local sounder off if it was activated for Fire condition or Fault condition;
activate the local sounder if the fire control panel is in Fire condition or Fault condition
and the local sounder has been switched off by a preceding pressing of the same button.
The LED indicator of the button illuminates of the local sounder is switched off for Fire
condition or Fault condition.

UniPOS Repeater FS5200R
Instruction Manual Page 16
Revision 3/01.17 of 48
A new fault condition will trigger the local sounder for Fault condition only.
8.3.2. Button (Menu)
Press the button to enter Information and Control Mode.
8.3.3. Buttons (Down) and (Up)
Press the buttons to see on the display the next/previous fault conditions.
8.3.5. Button (Exit)
Enter Information and Control
Mode to review the fault events.
Upon pressing the button
(Menu) the following options are
available:
01 Review Faults
02 Review Disables
03 Review Statuses
04 System Function
12345678910 11 12 13 14 15
Press the button
(Menu) again to enter submenu
Review Faults.
Information about the first fault
appears on the display. Use the
buttons (Down) and (Up)
to display the rest of the fault
conditions.
12345678910 11 12 13 14 15
Press button (Exit) to exit
the review of the faults.
Upon exit the fire conditions the
LED and sound indication is switched
off.
12345678910 11 12 13 14 15

UniPOS Repeater FS5200R
Instruction Manual Page 17
Revision 3/01.17 of 48
9. Disabled Component
9.1. Description
The repeater enters Disabled component after a manual operation, disabling a specific
component –monitored output or relay for fire condition. A disabled monitored output is switched
off and is not monitored for fault condition.
That condition is controlled via the screens of System Functions.
Its control is accessible from all Access levels.
9.2. Indication
9.2.1. LED and sound indication
No LED and sound indication is supported for Disabled component condition.
9.2.2. Text messages
The text messages are displayed in System information condition.
9.3. Using the buttons
Upon pressing the button
(Menu) the following options are
available:
01 Review Faults
02 Review Disables
03 Review Statuses
04 System Function
Press the button (Down)
three times to move the cursor to
System Functions.
12345678910 11 12 13 14 15
Press the button
(Menu) again to enter submenu:
01 Indication check
02 Clock
03 Disable outputs
04 Parameters reviews
Press the button (Down)
twice to move the cursor to Disable
Outputs.
12345678910 11 12 13 14 15

UniPOS Repeater FS5200R
Instruction Manual Page 18
Revision 3/01.17 of 48
Confirm the selection with
button (Menu) and use the
buttons (Down) and
(Up) to select the output to be
disabled.
Confirm the selection with
button (Menu).
12345678910 11 12 13 14 15
After confirming the selection
with button (Menu), use the
buttons (Down) and
(Up) to choose the condition of the
selected output (Off/On).
Confirm the change with button
(Menu) or cancel the change
with button (Exit).
12345678910 11 12 13 14 15
Upon confirming the change
with button (Menu) a
message appears that the change is
saved and for exit the menu.
12345678910 11 12 13 14 15
Where an output is disabled it is not activated for Fire condition and data are not
processed for a Fault condition in the monitored outputs line.

UniPOS Repeater FS5200R
Instruction Manual Page 19
Revision 3/01.17 of 48
9.4. Review of the entered disables
Enter Information and Control Mode to review the entered disables. The menu is accessible for
all Access levels.
Enter the main menu
with button
(Menu);
Press once
(Down) and the cursor
moves to “02 Review
Disables;
Confirm the selection
with button
(Menu);
The entered disables are
displayed (e.g. Out1,
Out2, RelFr) or if there
are no disables –“No
disables” is shown;
To exit the menu use
button (Exit).
12345678910 11 12 13 14 15
12345678910 11 12 13 14 15
10. Information and Control Mode
Information and Control Mode provides the user with the possibilities to:
-display information about the repeater;
-enter control data;
-display information about the connected fire control panels (repeaters).
To enter Information and Control Mode, press button on the screen for Duty Mode,
Fire Condition, Fault Condition (with the exception of the screen for fatal error) and Disabled
component which suppresses their text messages.
.
The following buttons are active in Information and Control Mode:
-button (Menu);
-button (Down);

UniPOS Repeater FS5200R
Instruction Manual Page 20
Revision 3/01.17 of 48
-button (Up);
-button (Exit).
No specific LEDs or sound indication is provided for Information and Control Mode.
The screens visualized on the display are organized in a tree structure, containing
subordinate menus.
Other manuals for FS5200R
1
Table of contents