Ursalink EM300 Series User manual

EM300 Series
User Guide
www.ursalink.com

EM300 Series User Guide
www.ursalink.com
2
Safety Precautions
Ursalink will not shoulder responsibility for any loss or damage resulting from not following
the instructions of this operating guide.
The device must not be remodeled in any way.
The device is not intended to be used as a reference sensor, and Ursalink will not should
responsibility for any damage which may result from inaccurate readings.
Do not place the device close to objects with naked flames.
Do not place the device where the temperature is below/above the operating range.
Make sure electronic components do not drop out of the enclosure while opening.
When installing the battery, please install it accurately, and do not install the reverse or
wrong model.
Make sure both batteries are newest when install, or battery life will be reduced.
The device must never be subjected to shocks or impacts.
Declaration of Conformity
EM300 series is in conformity with the essential requirements and other relevant provisions
of the CE, FCC, and RoHS.
© 2017-2020 Xiamen Ursalink Technology Co., Ltd.
All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or
individual shall copy or reproduce the whole or part of this user guide by any means without
written authorization from Xiamen Ursalink Technology Co., Ltd.
For assistance, please contact
Ursalink technical support:
Email: helpdesk@ursalink.com
Tel: 86-592-5023060
Fax: 86-592-5023065
Revision History
Date
Doc Version
Description
October 14, 2020
V 1.0
Initial version
October 21, 2020
V 1.1
Model name change and pictures replace

EM300 Series User Guide
www.ursalink.com
3
Contents
1. Introduction.....................................................................................................................................4
1.1 Overview................................................................................................................................4
1.2 Features.................................................................................................................................4
2. Hardware......................................................................................................................................... 4
2.1 Packing List............................................................................................................................ 4
2.2 Product Overview..................................................................................................................5
2.3 Dimensions(mm)................................................................................................................... 5
2.4 Power Button Descriptions................................................................................................... 6
3. Configuration...................................................................................................................................6
3.1 Configuration via Smartphone APP.......................................................................................6
3.1.1 Read/Write Configuration via NFC.............................................................................6
3.1.2 Template Configuration..............................................................................................8
3.2 Configuration via PC.............................................................................................................. 9
3.2.1 Log in the Toolbox...................................................................................................... 9
3.2.2 Basic Configuration.................................................................................................. 10
3.2.3 Template Settings.....................................................................................................11
3.2.4 Upgrade....................................................................................................................12
3.3 Configuration Examples...................................................................................................... 12
3.3.1 LoRaWAN Channel Settings..................................................................................... 12
3.3.2 Alarm Settings.......................................................................................................... 13
4. Installation..................................................................................................................................... 14
5. Payload Format..............................................................................................................................15
6. Ursalink Cloud Management.........................................................................................................16
6.1 Add a Ursalink LoRaWAN Gateway..................................................................................... 16
6.2 Add EM300 to Cloud........................................................................................................... 17
Appendix............................................................................................................................................18
Default LoRaWAN Parameters.................................................................................................. 18
Default Uplink Channels............................................................................................................18

EM300 Series User Guide
www.ursalink.com
4
1. Introduction
1.1 Overview
EM300 series is a sensor mainly used for outdoor environment through wireless LoRa network.
EM300 device is battery powered and designed for multiple mounting ways. It is equipped with
NFC (Near Field Communication) and can easily be configured by a smartphone or a PC software.
Sensor data are transmitted in real-time using standard LoRaWAN protocol. LoRaWAN enables
encrypted radio transmissions over long distance while consuming very little power.
The user can obtain sensor data and view the trend of data change through Ursalink Cloud or
through the user's own Network Server.
1.2 Features
Up to 11km communication range
Easy configuration via NFC
Standard LoRaWAN support
Ursalink Cloud compliant
Low power consumption with 4000mAh replaceable battery
2. Hardware
2.1 Packing List
1 × EM300
Wall Mounting
Kits
1 ×
Warranty Card
1 ×
Quick Guide
Mounting Screws (for
SLD or MCS sensor)
Double Sided Tape(for
SLD or MCS sensor)
1 × NFC
Reader(Optional)
If any of the above items is missing or damaged, please contact your Ursalink sales
representative.

EM300 Series User Guide
www.ursalink.com
5
2.2 Product Overview
2.3 Dimensions(mm)
Bottom View:
②Vent
③Waterproof Connectors
(For water leakage and magnet switch sensor)
Internal View:
④LED
⑤Power Button
⑥USB Type-C
⑦Expandable Battery Slot
⑧Battery
Front View:
①NFC Area

EM300 Series User Guide
www.ursalink.com
6
2.4 Power Button Descriptions
Note: The LED indicator and power button are inside the device. EM300 can also be turned
on/off and reset via Mobile APP or Toolbox.
Function
Action
LED Indication
Turn On
Press and hold the button for more than
3 seconds.
Off → Static Green
Turn Off
Press and hold the button for more than
3 seconds.
Static Green -> Off
Reset
Press and hold the button for more than
10 seconds.
Note: EM300 will automatically power on after
reset.
Blink 3 times.
Check
On/Off Status
Quickly press the power button.
Light On: Device is on.
Light Off: Device is off.
3. Configuration
EM300 sensor can be monitored and configured via one of the following methods:
Mobile APP (NFC);
Windows software (NFC or Type-C port).
In order to protect the security of sensor, password validation is required when configuring via
unused phone . Default password is 123456.
3.1 Configuration via Smartphone APP
Preparation:
Smartphone (NFC supported)
Toolbox APP: download and install from Google Play or Apple Store.
3.1.1 Read/Write Configuration via NFC
1. Enable NFC on the smartphone and open“Toolbox”APP.
2. Attach the smartphone with NFC area to the device to read basic information.
Note: Ensure your smartphone NFC area and it is recommended to take off phone case before
using NFC.

EM300 Series User Guide
www.ursalink.com
7
3. Change the on/off status or parameters, then attach the smartphone with NFC area to the
device until the APP shows a successful prompt.
4. Go to“Device > Status”to tap“Read”and attach the smartphone with NFC area to the device to
read real-time data of sensor.

EM300 Series User Guide
www.ursalink.com
8
3.1.2 Template Configuration
Template settings only work for easy and quick device configuration in bulk.
Note: Template function is allowed only for sensors with the same model and LoRa frequency
band.
1. Go to “Template” page on the APP and save current settings as a template.
2. Attach the smartphone with NFC area to another device.
3. Select the template file from Toolbox APP and tap “Write”,keep the two devices close until the
APP shows a successful prompt.
4. Slide the template item to the left to edit or delete the template.

EM300 Series User Guide
www.ursalink.com
9
3.2 Configuration via PC
Preparation:
Dedicated NFC Reader or Type-C USB cable
PC (Windows 10)
Toolbox: https://www.ursalink.com/en/software-download/
3.2.1 Log in the Toolbox
Make sure “Toolbox” is downloaded on your computer. Select one of the following methods to
log in Toolbox.
Type-C Connection
1. Open the case of EM300 and connect the EM300 to computer via type-C port.
2. Select type as “General” and click password to log in Toolbox. (Default password: 123456)
NFC Connection
1. Connect the NFC reader to computer, then attach the EM300 to NFC area of the reader.

EM300 Series User Guide
www.ursalink.com
10
2. Select type as “NFC” and serial port as NFC reader port on Toolbox.
3.2.2 Basic Configuration
1. Click “Read” to read current data of the sensor.
2. When you perform one of the following operations, enter the password and wait a few
seconds until toolbox shows a successful prompt. (Password is not need if you connect it via
type-C port)

EM300 Series User Guide
www.ursalink.com
11
Turn on/off the sensor
Reset the sensor
Click“Write”to change settings
Upgrade
3.2.3 Template Settings
Note: Template function is allowed only for sensors with the same model and LoRa frequency
band.
1. Go to “Maintenance -> Template and Reset” page in Toolbox.
2. Click “Export” to save the current settings as a template.
3. Click “Browse” to select the correct template from computer.
4. Click “Import” to import the template to the device.

EM300 Series User Guide
www.ursalink.com
12
3.2.4 Upgrade
1. Download firmware on your computer.
2. Go to “Maintenance -> Upgrade”page in Toolbox.
3. Click“Browse”and select the firmware from computer.
4. Click“Upgrade”to upgrade the device.
Note: If NFC connection is selected, please keep the two devices close and don’t move them in
order to get the best connectivity as possible when upgrading.
3.3 Configuration Examples
3.3.1 LoRaWAN Channel Settings
The configuration of LoRaWAN channel of EM300 must match the LoRaWAN gateway’s. Refer to
Appendix to check default channel settings of EM300.
Mobile APP Configuration:
Open Toolbox APP and go to“Device ->Setting -> LoRaWAN Settings”to change the frequency and
channels.
Software Configuration:
Log in Toolbox and go to“LoRaWAN Settings -> Channel”to change frequency and channels.
Note: If frequency is one of CN470/AU915/US915, you can enter the index of the channel that
you want to enable in the input box, making them separated by commas.

EM300 Series User Guide
www.ursalink.com
13
Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60
All: Enabling all channels
Null: Indicates that all channels are disabled
3.3.2 Alarm Settings
When water leakage sensor or magnet switch sensor is triggered, it will send alarm message once
by default. Toolbox allows users to change the alarm reporting interval and reporting times.
Mobile APP Configuration:
Open Toolbox APP and go to“Device -> Setting -> Threshold Settings”to enable the threshold
settings and input the threshold.
Software Configuration:
Log in Toolbox and go to“Device Settings -> Basic -> Threshold Settings”to enable the calibration
and input the calibration value.

EM300 Series User Guide
www.ursalink.com
14
4. Installation
1. Attach EM300 to the wall and mark the two holes on the wall. The connecting line of two
holes must be a horizontal line.
2. Drill the holes according to the marks and screw the wall plugs into the wall.
3. Mount the EM300 to the wall via mounting screws.
4. Cover the mounting screws with screw caps.
5. For leak detection senor, install the probe/cable to the place where liquid may leak. For magn
et switch sensor, install the magnet beside the door/window.
Note: For SLD sensor, please ensure the metal pins of the probe are flat on the floor; for ZLD
sensor, the cable can’t be twined or accumulated together. The probe or cable of water leakage
sensor should be placed in an area of concern where water from a leak would likely accumulate.

EM300 Series User Guide
www.ursalink.com
15
5. Payload Format
All data are based on following format:
Channel1
Type1
Data1
Channel2
Type2
Data2
Channel 3
...
1 Byte
1 Byte
N Bytes
1 Byte
1 Byte
M Bytes
1 Byte
...
Please refer to decoder example: https://github.com/Ursalink-CN/ursalink-decoder
Uplink Packet(HEX)
Downlink Packet(HEX)
Channel
Type
Data Example
Description
01
75(Battery Level)
64
64=>100
Battery level =100%
03
67 (Temperature)
10 01
10 01 => 01 10 = 272
Temp=272*0.1=27.2°C
04
68(Humidity)
71
71=>113
Hum=113*0.5=56.5%
05
00
00
Not water leakage
01
Water leakage
06
00
00
Magnet switch closed
01
Magnet switch open
ff
01(Ursalink Protocol
Version)
01
V1
08 (Device SN)
64 10 90 82 43 75
00 01
Device SN is
641090824375000
09 (Hardware Version)
01 40
V1.4
0a(Software Version)
01 14
V1.14
0f(Device Type)
00
Class A
Channel
Type
Data Example
Description
ff
03(Set Reporting Interval)
b0 04
b0 04 => 04 b0 = 1200s

EM300 Series User Guide
www.ursalink.com
16
6. Ursalink Cloud Management
EM300 sensors can be managed by Ursalink Cloud platform. Ursalink cloud is a comprehensive
platform that provides multiple services including device remote management and data
visualization with the easiest operation procedures. Please register a Ursalink Cloud account
before operating following steps.
Ursalink Cloud URL: https://cloud.ursalink.com/login.html
6.1 Add a Ursalink LoRaWAN Gateway
1. Enable “Ursalink” type network server and “Ursalink Cloud” mode in gateway web GUI.
Note: Ensure gateway has accessed the Internet.
2. Go to “My Devices” page and click “+New Devices” to add gateway to Ursalink Cloud via SN.
Gateway will be added under “Gateways” menu.

EM300 Series User Guide
www.ursalink.com
17
3.Check if gateway is online in Ursalink Cloud.
6.2 Add EM300 to Cloud
1. Go to “My Devices” page and click “+New Devices”. Fill in the SN of EM300 and select
associated gateway.
2.After EM300 is connected to Ursalink Cloud, you could check the device information and data
and create dashboard for it.

EM300 Series User Guide
www.ursalink.com
18
Appendix
Default LoRaWAN Parameters
DevEUI
24E124 + 2nd to 11th digits of SN
e.g. SN = 61 26 A1 01 84 96 00 41
Then Device EUI = 24E124126A101849
AppEUI
24E124C0002A0001
Appport
0x55
NetID
0x010203
DevAddr
The 5th to 12th digits of SN
e.g. SN = 61 26 A1 01 84 96 00 41
Then DevAddr = A1018496
AppKey
5572404C696E6B4C6F52613230313823
NwkSKey
5572404C696E6B4C6F52613230313823
AppSKey
5572404C696E6B4C6F52613230313823
Default Uplink Channels
Model
Channel Plan
Channel Settings/MHz
EM300-470
CN470
470.3~489.3(All 95 channels)
EM300-868
EU868
868.1, 868.3, 868.5
RU864
868.9, 869.1
IN865
865.0625, 865.4025, 865.6025
EM300-915
AU915
915.2~927.1 (All 72 channels)
US915
902.3~914.2 (All 72 channels)

EM300 Series User Guide
www.ursalink.com
19
KR920
922.1, 922.3, 922.5
AS923
923.2, 923.4
-END-