Ursalink UC11-T1 User manual


2
Contents
1. Preface.............................................................................................................................................3
2. Introduction.................................................................................................................................... 3
2.1 Features.................................................................................................................................3
2.2 Parameters............................................................................................................................ 4
2.3 Turn on/off the Sensor......................................................................................................... 4
3. Configuration via PC....................................................................................................................... 4
3.1 Configuration via ToolBox.................................................................................................... 4
3.2 Status.....................................................................................................................................6
3.3 LoRaWAN.............................................................................................................................. 7
3.3.1 Basic-OTAA.................................................................................................................7
3.3.2 Basic-ABP................................................................................................................... 9
3.3.3 Channel.................................................................................................................... 12
3.4 Upgrade...............................................................................................................................13
4.Configuration via Ursalink Cloud.................................................................................................. 14
4.1 Account Setup.....................................................................................................................14
4.2 Add a Ursalink LoRaWAN Gateway................................................................................... 15
4.3 Add Devices to Ursalink Cloud...........................................................................................17
4.4 Check the Data of UC11-T1................................................................................................ 20
4.5 Configure UC11-T1 via Ursalink Cloud...............................................................................20
4.5.1 Basic Settings........................................................................................................... 21
5.Configuration via TTN....................................................................................................................23
5.1 Add a LoRaWAN Gateway to The Things Network........................................................... 23
5.1.1 Register Your Gateway in The Things Network......................................................23
5.1.2 Connect Ursalink gateway to The Things Network................................................24
5.2 Add UC11-T1 To The Things Network................................................................................ 26
5.2.1 Create an Application in The Things Network....................................................... 26
5.2.2 Add Devices to The Application..............................................................................27
5.2.3 Configure UC11-T1.................................................................................................. 28
5.3 Check Data Transmission on The Things Network............................................................ 29

3
1. Preface
Thank you for choosing Ursalink UC11-T1. This user guide will present in detail all the functions
and features of the product. The UC11-T1 is designed for both industrial and commercial
applications and helps devices stay connected. The product should be used under the guidance
of this user manual, referring to parameters and technical specifications. The UC11-T1 is a
compact, high-performance device server that offers LoRaWAN connectivity for remote access
and easy management of machines and equipment over the LoRaWAN gateway.
We bear no liability for property loss or physically injury arising from abnormal or incorrect usage
of this product.
2. Introduction
UC11-T1 is a smart wireless module, featuring LoRaWAN protocol, equipped with a high-precision
temperature and relative humidity sensor. This sensor can measure temperatures from -40°C to
+ 70°C, as well as air humidity from 0 to 100%.
The sensor is optimized for long battery life and excellent RF performance. It is fully configurable
over the air by the user for custom applications, thresholds, trigger events and reports.
This user guide is intended to provide detailed technical specifications and explanations to basic
users as well as the technically-minded groups. It is a live document, and will be updated from
time to time. Please ensure that you have the latest version, by checking our website at:
https://www.ursalink.com/en/documents-download/
2.1 Features
Customize temperature alert thresholds
Powered by replaceable Li-ion battery: 8000mA
Battery life: 4 years of operation for 1 uplink per 20minutes
LoRaWAN compatible: Class A, uplink rate programmable from 5 minutes to 30 minutes
Compatible with multiple third-party platforms and Ursalink Cloud
Support Frequency: CN470 /EU868 / US915 / EU433 / AU915 / AS923 / KR920 / IN865
LoRa wireless module included, up to 11 km range

4
2.2 Parameters
2.3 Turn on/off the Sensor
Put a magnet close to the reed switch to turn on or turn off the sensor.
Buzzer rings for 2 seconds: power on.
Buzzer rings for 6 seconds: power off.
3. Configuration via PC
3.1 Configuration via ToolBox
Follow these steps:
Step 1: Connect the Ursalink UC11-T1 to PC via USB port.
Step 2: Power on the Ursalink UC11-T1.
Step 3: Run the Ursalink ToolBox.
Parameter Item
Reference Scope
Measuring
Range/Accuracy
Temperature: ±0.3°C from 0°C to + 70°C,
±0.6°C from -40°C to 0°C
Humidity: ±3% RH from 10% to 90%,
±5% RH below 10% and above 90%
Frequency Band
EU 433, CN 470-510, EU 863-870, US 902-928, AU
915-928, KR 920-923
Antenna
Embedded Ceramic antenna
Operating
Temperature
-40°C to +70°C (-40°F to +158°F)
Relative Humidity
0% to 100% (non-condensing)
Power Supply
Powered by replaceable Li-ion battery:
8000mAh/3.6V
Dimensions
111 x 92 x 33 mm
Waterproof Grade
IP65

5
When the Ursalink ToolBox displays: Connecting to device, please wait...
You can click Serial Port Settings to set the correct serial port parameters.
Serial Port Settings
Item
Description
Default
Serial Port
Select the serial port for data transmission.
Null
Login Password
Enter the correct password to login.
123456
Baud Rate
Select from "9600", "57600", "115200".
57600
Data Bit
Select from "5", "7", "8".
8
Parity Bit
Select from "Even", "Odd", "None".
None
Stop Bit
Select from "1", "2".
1

6
If the serial port parameter is correct, it will display: Serial port is connected.
3.2 Status
Click "Status" to see the basic status information of this device:
Status
Item
Description
Local Time
Show the time of the device.
Join Status
Show if the device join the network successfully.
The "Activate" means the device has joined the network.
RSSI/SNR
Show the RSSI/SNR of received packet.

7
Temperature
Show the temperature value.
Humidity
Show the humidity value.
Battery
Show the battery level.
Uplink Frame-counter
The number of data frames sends uplink from UC11-T1 to the
network server.
Downlink
Frame-counter
The number of data frames sends downlink from the network
server to UC11-T1.
3.3 LoRaWAN
3.3.1 Basic-OTAA

8
Basic Settings-OTAA
Item
Description
Default
Device EUI
Show the identifier of this device.
the
identifier
of this
device.
App EUI
Enter the application EUI.The Network Server receives
request and consults the entity associated with the APP
EUI to validate the request.If permission is granted, it
responds with a join-accept message.
24e124c00
02a0001
Join Type
Select from: "OTAA" and "ABP".
OTAA:Over-the-Air Activation.
For over-the-air activation, end-devices must follow a
join procedure prior to participating in data exchanges
with the network server. An end-device has to go
through a new join procedure every time it has lost the
session context information.
ABP: Activation by Personalization.
Under certain circumstances, end-devices can be
activated by personalization. Activation by
personalization directly ties an end-device to a specific
network by-passing the join request - join accept
procedure.
OTAA
Application Key
Enter the application key. Whenever an end-device joins
a network via over-the-air activation, the application key
is used to derive the Application Session key.
5572404c6
96e6b4c6f
526132303
13823
Reporting
Interval
The UC11-T1 reports the temperature and humidity at
regular intervals.
Range: 5-30 (mins)
20
Regular Report
Confirmed
After sending the regular report packet to the network
server, if the device does not receive ACK bit from the
network server, then the device will resend the packet.
Note: If the device doesn't receive ACK for a long time,
the device will resend regular report confirmed packets
3 times at most.
Disabled
Alarm Report
Confirmed
After sending the attribute package or alarm packet to
the network server, if the device does not receive ACK
Disabled

9
bit from the Network Server, then the device will resend
the packet.
Note: If the device doesn't receive ACK for a long time,
the device will resend regular report confirmed packets
3 times at most. However, the device will resend
attribute package all the time.
Temperature
Intelligent
Report
When the temperature changes beyond 2 ℃(35.6 ℉),
the device will automatically report the latest value.
Enabled
Temperature
Alarm
Enable: The device will send an alarm notification to
Network Server if the temperature goes above/below
temperature thresholds.
Disabled
greater than
Enter the maximum temperature threshold.
Null
less than
Enter the minimum temperature threshold.
Null
Note: If you set a "lockout time" of 10s, a "continued time" of 5s, the alarm will be triggered as
soon as the temperature goes above the maximum temperature threshold or goes below the
minimum temperature threshold for 5s. It will then start checking the temperature again after
10s and be triggered once more if the temperature goes above/below temperature thresholds
for 5s.
3.3.2 Basic-ABP

10
Basic Settings-ABP
Item
Description
Default
Device EUI
Show the identifier of this device.
the
identifier
of this
device.
App EUI
Enter the application EUI.The Network Server receives
request and consults the entity associated with the APP
EUI to validate the request.If permission is granted, it
responds with a join-accept message.
24e124c00
02a0001
Join Type
Select from: "OTAA" and "ABP".
OTAA:Over-the-Air Activation.
For over-the-air activation, end-devices must follow a
join procedure prior to participating in data exchanges
with the network server. An end-device has to go
through a new join procedure every time it has lost the
session context information.
ABP: Activation by Personalization.
Under certain circumstances, end-devices can be
activated by personalization. Activation by
personalization directly ties an end-device to a specific
network by-passing the join request - join accept
procedure.
OTAA
Device Address
Enter the device address. The device address identifies
the end-device within the current network.
The last 8
digits
number of
SN
Network Session
Key
Enter the network session key of the device. The
network session key specific for the end-device. It is used
by the end-device to calculate the MIC or part of the MIC
(message integrity code) of all uplink data messages to
ensure data integrity.
5572404c6
96e6b4c6f
526132303
13823

11
Application
Session Key
Enter the application session key of the device. The
AppKey is an application session key specific for the
end-device. It is used by both the application server and
the end-device to encrypt and decrypt the payload field
of application-specific data messages.
5572404c6
96e6b4c6f
526132303
13823
Reporting
Interval
The UC11-T1 reports the temperature and humidity at
regular intervals.
Range: 5-30 (mins)
20
Regular Report
Confirmed
After sending the regular report packet to the network
server, if the device does not receive ACK bit from the
network server, then the device will resend the packet.
Note: If the device doesn't receive ACK for a long time,
the device will resend regular report confirmed packets
3 times at most.
Disabled
Alarm Report
Confirmed
After sending the attribute package or alarm packet to
the network server, if the device does not receive ACK
bit from the Network Server, then the device will resend
the packet.
Note: If the device doesn't receive ACK for a long time,
the device will resend regular report confirmed packets
3 times at most. However, the device will resend
attribute package all the time.
Disabled
Temperature
Intelligent
Report
When the temperature changes beyond 2 ℃(35.6 ℉),
the device will automatically report the latest value.
Enabled
Temperature
Alarm
Enable: The device will send an alarm notification to
Network Server if the temperature goes above/below
temperature thresholds.
Disabled
greater than
Enter the maximum temperature threshold.
Null
less than
Enter the minimum temperature threshold.
Null

12
3.3.3 Channel
On this page, you can view all of the supported LoRa frequencies and setup the channel
frequency used for receiving and sending data.
Note: Make sure the you have configured the corresponding channel on the gateway.
E.g. If you have configured a 923.2 MHz channel on UC11-T1, then you have to configure a 923.2
MHz channel on gateway as well.

13
3.4 Upgrade
Step 1: Connect UC11-T1 to PC via the usb port.
Step 2: Install the battery to power on UC11-T1.
Step 3: Run the Ursalink ToolBox and go to "Upgrade".
Step 4: Click "Browse" and select the correct firmware file from the PC.
Step 5: Click "Upgrade" and the device will check if the firmware file is correct. If it’s correct, the
firmware will be imported to the device, and the device will reboot after upgrading is completed.
Note: Any operation on Ursalink ToolBox is not allowed during upgrading, otherwise the
upgrading will be interrupted, or even the device will break down.

14
4.Configuration via Ursalink Cloud
4.1 Account Setup
To set up an account with Ursalink Cloud, follow these steps:
1. Go to : https://cloud.ursalink.com/login.html to register a Ursalink Cloud account.
2. Log in to Ursalink Cloud after the email has been verified.
Note: It is important that you have access to the verified email address before proceeding.

15
4.2 Add a Ursalink LoRaWAN Gateway
To add your Ursalink gateway to the Ursalink Cloud, please follow these steps:
1. On the main page, click "Gateway".
2. On the gateway page, click "Add" to add a gateway.
Enter the correct SN of the gateway and click “Add”. You can find your gateway SN either on the
label on the bottom of the device or on the web GUI .

16
Note: Please make sure the working mode of gateway is Ursalink Cloud.
Once the device has been added successfully, You will see the device in the list.

17
4.3 Add Devices to Ursalink Cloud
To add a UC11-T1 to Ursalink Cloud, please follow these steps:
1. Click to go to the configuration page of this gateway.
2. Click then click “Associated Devices” .
3. Click ”Add” to add a UC11-T1 to this gateway.

18
4. Enter the correct SN of the UC11-T1, and then click ”Add”. Sensor SN can be found on the
bottom of the sensor.
5. Once the device has been added successfully, You will see the device in the list.
You can also add UC11-T1 directly to the main page, please follow these steps:
1. Click “Add” on the upper left corner.

19
2. Enter the correct SN of UC11-T1 and select the correct gateway. Then click “Add”.
3. Once the device has been added successfully, You will see the device in the list.

20
4.4 Check the Data of UC11-T1
Click “LoRaWAN”->”Network Server”->”Packets” to view the data transmission.
You can see the basic status of the UC11-T1 on the Ursalink Cloud main page.
4.5 Configure UC11-T1 via Ursalink Cloud
Click to go to the configuration page of UC11-T1. You can edit the basic information of the
device on this page.
Other manuals for UC11-T1
1
This manual suits for next models
1
Table of contents
Popular Temperature Controllers manuals by other brands

ECR International
ECR International ARGO DPM-2 Installation, operation & maintenance manual

Daikin McQuay
Daikin McQuay IOM 1177 Installation operation & maintenance data

AKO
AKO 14632 instructions

KIOUR
KIOUR TOUCH LINE RSD manual

winkler
winkler W-700 Series Operation manual

Smartharvest
Smartharvest SRTS-6M instruction sheet