UTAdvanced UT75A User manual

IM 05P01B41-11EN page 1/14
Contents
1. Safety Precautions
2. ModelandSufxCodes
3. How to Install
4. HardwareSpecications
5. HowtoConnectWires
6. TerminalWiringDiagrams
Introduction
ThankyouforpurchasingtheUT75ADigitalIndicatingController.
Thisoperationguidedescribesthebasicoperationsrelatedtothesingle-loopcontrol
functionoftheUT75A.Theguideshouldbeprovidedtotheenduserofthisproduct.
Besuretoreadthisoperationguidebeforeusingtheproductinordertoensure
correct operation.
Beforeusingtheproduct,refertothetableofModelandSufxCodestomakesure
thatthedeliveredproductisconsistentwiththemodelandsufxcodesyouordered.
Alsomakesurethatthefollowingitemsareincludedinthepackage.
•DigitalIndicatingController(themodelyouordered)..............................x1
• Set of Brackets........................................................................................x1
•UnitLabel(L4502VZ) ..............................................................................x1
•TagLabel(L4502VE)(Onlywhenordered.) ...........................................x1
•TerminalCover(L4502XPforUT75A) ....................................................x1
•OperationGuideforSingle-loopControl(thisdocument) .......................x7(A3size)
(InstallationandWiring,InitialSettings,Operations,andParameters)
l
TargetReaders
Thisguideisintendedforthefollowingpersonnel;
• Engineersresponsibleforinstallation,wiring,andmaintenanceoftheequipment.
• Personnelresponsiblefornormaldailyoperationoftheequipment.
1. Safety Precautions
Thefollowingsymbolisusedontheinstrument.Itindicatesthepossibilityofinjury
totheuserordamagetotheinstrument,andsigniesthattheuser must refer to
theuser’smanualforspecialinstructions.Thesamesymbolisusedintheuser’s
manualonpagesthattheuserneedstoreferto,togetherwiththeterm“WARNING”
or“CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious
or fatal injury to the user, and indicates precautions that should be
taken to prevent such occurrences.
CAUTION
Calls attention to actions or conditions that could cause injury to
the user or damage to the instrument or property and indicates pre-
cautions that should be taken to prevent such occurrences.
AC
AC/DC
Theequipmentwhollyprotectedbydoubleinsulationorreinforcedinsulation.
Functionalgroundingterminals
(Donotusethisterminalasaprotectivegroundingterminal).
Note
Identiesimportantinformationrequiredtooperatetheinstrument.
■Warning and Disclaimer
(1) YOKOGAWA makesno warrantiesregardingtheproduct exceptthose statedin
theWARRANTYthatisprovidedseparately.
(2) Theproductisprovidedonan"asis"basis.YOKOGAWAassumesnoliabilityto
anypersonorentityforanylossordamage,directorindirect,arisingfromthe
useoftheproductorfromanyunpredictabledefectoftheproduct.
■ Safety,Protection,andModicationoftheProduct
(1)Inordertoprotectthesystemcontrolledbythis product and the productitself,
andtoensuresafeoperation,observethesafetyprecautionsdescribedinthe
user’smanual. Useoftheinstrumentinamannernotprescribedherein may
compromise the product's functions and the protection features inherent in the
device.Weassumenoliabilityforsafety,orresponsibilityfortheproduct'squality,
performanceorfunctionalityshouldusersfailtoobservetheseinstructionswhen
operatingtheproduct.
(2)Installationofprotectionand/or safety circuits with respect toalightning
protector;protectiveequipmentforthesystemcontrolledbytheproductandthe
productitself;foolprooforfail-safedesignofaprocessorlineusingthesystem
controlledbytheproductortheproductitself;and/orthedesignandinstallation
ofotherprotectiveandsafetycircuitsaretobeappropriatelyimplementedasthe
customer deems necessary.
(3) Be sureto usethesparepartsapprovedbyYOKOGAWA whenreplacing parts
orconsumables.
(4) This productis not designedor manufacturedtobe usedin criticalapplications
thatdirectlyaffectorthreatenhumanlives.Suchapplicationsincludenuclear
powerequipment,devicesusingradioactivity,railway facilities, aviation
equipment,airnavigationfacilities,aviationfacilities,andmedicalequipment.
Ifsoused,itistheuser’sresponsibilitytoincludeinthesystemadditional
equipmentanddevicesthatensurepersonnelsafety.
(5) Modicationoftheproductisstrictlyprohibited.
(6)Thisproductisintendedtobehandled by skilled/trainedpersonnelforelectric
devices.
(7)ThisproductisULRecognizedComponent.InordertocomplywithUL
standards,end-productsarenecessarytobedesignedbythosewhohave
knowledgeoftherequirements.
WARNING
l
Power Supply
Ensure that the instrument’s supply voltage matches the voltage
of the power supply before turning ON the power.
lDo Not Use in an Explosive Atmosphere
Do not operate the instrument in locations with combustible
or explosive gases or steam. Operation in such environments
constitutes an extreme safety hazard. Use of the instrument in
environments with high concentrations of corrosive gas (H2S,
SOX, etc.) for extended periods of time may cause a failure.
lDo Not Remove Internal Unit
The internal unit should not be removed by anyone other than
YOKOGAWA's service personnel. There are dangerous high
voltage parts inside. Additionally, do not replace the fuse by
yourself.
lDamage to the Protective Construction
Operation of the instrument in a manner not specified in the
user’s manual may damage its protective construction.
CAUTION
This instrument is an EMC class A product. In a domestic environ-
ment this product may cause radio interference in which case the
user needs to take adequate measures.
2. ModelandSufxCodes
■UT75A
Model Sufxcode
Optional
sufx
code
Description
UT75A
DigitalIndicatingController(providedwithretrans-
missionoutputor15VDClooppowersupply,3DIs,
and3DOs)(Powersupply100-240VAC)
Type 1:
Basic
control
-0 Standard type
-1 Position proportional type
-5 Dual-looptype
Type 2:
Functions
05additionalDIsand5additionalDOs
1
Remote(1additionalaux.analog)input,RS485
communication(Max.19.2kbps,2-wire),1additional
DI,and5additionalDOs
2
Remote(2additionalaux.analog)inputs,RS485
communication(Max.19.2kbps,2-wire),2additional
DIs
3Remote(1additionalaux.analog)input,6additional
DIs,5additionalDOs(*1)
Type3:Open
networks
0None
1
RS-485communication(Max.38.4kbps,2-wire/4-wire)
and5additionalDIs
2
Ethernetcommunication(withserialgatewayfunction)
3
CC-Linkcommunication(withModbusmasterfunction)
4
PROFIBUS-DPcommunication(withModbusmasterfunction)
5
DeviceNetcommunication(withModbusmasterfunction)
Displaylanguage(*2)
-1
English(Default.CanbeswitchedtoSpanishbythesetting.)
-2 German(Customizedorder)
-3 French(Customizedorder)
-4
Spanish(Default.CanbeswitchedtoEnglishbythesetting.)
Casecolor 0White(Lightgray)
1Black(Lightcharcoalgray)
Fixedcode -00 Always"-00"
Optionalsufxcodes
/DC Powersupply24VAC/DC
/CP CarbonpotentialCalculationfunction(*3)
/CT Coating(*4)
*1: WhenType1codeis“-5”,“3”cannotbespecifiedforType2code.
*2: EnglishandSpanishareavailablefortheguidedisplay.(GermanandFrenchguidedisplays
arecustomized.Contactourrepresentativesforinquiries.)
*3: OnlywhenType2codeis“1”,“2”or“3”,the/CPoptioncanbespecified.
*4: Whenthe/CToptionisspecified,theUT75Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking(Productswith/CToptionarenotintendedforEEA-market).
■Accessories (sold separately)
Thefollowingisanaccessorysoldseparately.
• LL50AParameterSettingSoftware
Model Sufxcode Description
LL50A -00 ParameterSettingSoftware
• ExternalPrecisionResistor
Model Sufxcode Description
X010 SeetheGeneralSpecications(*) ResistanceModule
*:Necessarytoinputthecurrentsignaltothevoltageinputterminal.
• TerminalCover:ModelUTAP001
• User'sManual(A4size)
*User’sManualcanbedownloadedfromawebsite.
• Brackets
Partnumber:L4502TP(2pcsforupperandlowersides)
3. How to Install
■Installation Location
Theinstrumentshouldbeinstalledinindoorlocationsmeetingthefollowing
conditions:
• Instrumented panel
Thisinstrumentisdesignedtobemountedinaninstrumentedpanel.Mountthe
instrumentinalocationwhereitsterminalswillnotinadvertentlybetouched.
• Well ventilated locations
Mounttheinstrumentinwellventilatedlocationstopreventtheinstrument’sinter-
naltemperaturefromrising.
However,makesurethattheterminalportionsarenotexposedtowind.Exposure
to wind may cause the temperature sensor accuracy to deteriorate. To mount mul-
tipleindicatingcontrollers,seetheexternaldimensions/panelcutoutdimensions
whichfollow.Ifmountingotherinstrumentsadjacenttotheinstrument,complywith
thesepanelcutoutdimensionstoprovidesufcientclearancebetweentheinstru-
ments.
• Locations with little mechanical vibration
Installtheinstrumentinalocationsubjecttolittlemechanicalvibration.
• Horizontal location
Mounttheinstrumenthorizontallyandensurethatitislevel,withnoinclinationto
therightorleft.
Front panel
of controller Keep this angle
within 30°
Rear of
controller
30°
Note
Iftheinstrumentismovedfromalocationwith low temperature andlowhumidity
toaplacewithhightemperatureandhighhumidity,orifthetemperaturechanges
rapidly,condensationwillresult.Moreover,inthe case of thermocouple inputs,
measurementerrorswillresult.Toavoidsuchasituation,leavetheinstrumentinthe
newenvironmentunderambientconditionsformorethan1hourpriortousingit.
Donotmounttheinstrumentinthefollowinglocations:
• Outdoors
• Locations subject to direct sunlight or close to a heater
Installtheinstrumentinalocationwithstabletemperaturesthatremainclosetoan
averagetemperatureof23°C.Donotmountitinlocationssubjecttodirectsunlight
orclosetoaheater.Doingsoadverselyaffectstheinstrument.
• Locations with substantial amounts of oily fumes, steam, moisture, dust, or
corrosive gases
Thepresenceofoilyfumes,steam,moisture, dust, or corrosivegasesadversely
affectstheinstrument.Donotmounttheinstrumentinlocationssubjecttoanyof
thesesubstances.
• Areasnearelectromagneticeldgeneratingsources
Donotplacemagnetsortoolsthatgeneratemagnetismneartheinstrument.Ifthe
instrumentisusedinlocationsclosetoastrongelectromagneticeldgenerating
source,themagneticeldmaycausemeasurementerrors.
• Locationswherethedisplayisdifculttosee
TheinstrumentusesanLCDforthedisplayunit,andthiscanbedifculttosee
fromextremelyobliqueangles.Mounttheinstrumentinalocationwhereitcanbe
seenasmuchaspossiblefromthefront.
• Areasclosetoammablearticles
Absolutelydonotplacetheinstrumentdirectlyonam-
mablesurfaces.Ifsuchacircumstanceisunavoidable
andtheinstrumentmustbeplacedclosetoaammable
item,provideashieldforitmadeof1.43mmthickplated
steel or 1.6 mm thick unplated steel with a space of at
least150mmbetweenitandtheinstrumentonthetop,
bottom,andsides.
• Areas subject to being splashed with water
WARNING
Be sure to turn OFF the power supply to the controller before in-
stalling it on the panel to avoid an electric shock.
150 mm150 mm
150 mm
150 mm
Operation
Guide
IM 05P01B41-11EN
UT75A
Digital Indicating Controller
Operation Guide for Single-loop Control
This operation guide describes installation, wiring, and other tasks required to make the
controller ready for operation.
4th Edition : Mar. 2016
For details of the each function, refer to the electronic manual. User
's manuals can be
downloaded or viewed at the following URL.
Installation and Wiring
Functional
Enhancement
http://www.yokogawa.com/ns/ut/im/
www.yokogawa.com/ns
YOKOGAWA ELECTRIC CORPORATION
Network Solutions Business Division
2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JAPAN
YOKOGAWA CORPORATION OF AMERICA
Head office and for product sales
2 Dart Road, Newnan, Georgia 30265, USA
YOKOGAWA EUROPE B.V.
Headquarters
Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS
All Rights Reserved, Copyright © 2013 Yokogawa Electric Corporation
• AuthorisedRepresentativeintheEEA
YokogawaEuropeBV.(Address:Euroweg2,3825HDAmersfoort,The
Netherlands)istheAuthorisedRepresentativeofYokogawaElectricCorporation
forthisProductintheEEA.
• Printed Manuals
Model Description
UT75ADigitalIndicatingControllerOperationGuide IM05P01B41-11EN
PrecautionsontheUseoftheUTAdvancedSeries IM05P01A01-11EN
• ElectronicManuals
Youcandownloadthelatestmanualsfromthefollowingwebsite:
URL:http://www.yokogawa.com/ns/ut/im/
Model Description
UT75ADigitalIndicatingControllerOperationGuide IM05P01B41-11EN
UT75ADigitalIndicatingControllerUser’sManual IM05P01B41-01EN
UTAdvancedSeriesCommunicationInterface(RS-485,Ethernet)User’sManual IM05P07A01-01EN
UTAdvancedSeriesCommunicationInterface(OpenNetwork)User’sManual IM05P07A01-02EN
LL50AParameterSettingSoftwareInstallationManual IM05P05A01-01EN
LL50AParameterSettingSoftwareUser’sManual IM05P05A01-02EN
PrecautionsontheUseoftheUTAdvancedSeries IM05P01A01-11EN
• GeneralSpecication
Model Description
UT75ADigitalIndicatingController GS05P01B41-01EN
LL50AParameterSettingSoftware GS05P05A01-01EN
* Thelasttwocharactersofthemanualnumberandgeneralspecificationnumberindicatethe
languageinwhichthemanualiswritten.

IM 05P01B41-11EN page 2/14
■Mounting the Instrument Main Unit
Provideaninstrumentedpanelsteelsheetof1to10mmthickness.
Afteropeningthemountingholeonthepanel,followtheproceduresbelowtoinstall
the controller:
1) Insertthecontrollerintotheopeningfromthefrontofthepanelsothatthe
terminalboardontherearisatthefarside.
2) Setthebracketsinplaceonthetopandbottomofthecontrollerasshowninthe
gurebelow,thentightenthescrewsofthebrackets.Takecarenottoovertighten
them.
Bracket
(top mounting hardware)
Terminal board
Bracket
(bottom mounting hardware)
Panel
Insert a screwdriver into the
brackets to tighten the screws.
Direction to insert the
controller
Appropriate
tightening torque:
0.25 N•m
Insert the controller
into the opening at
the front of the panel.
CAUTION
• Tighten the screws with appropriate tightening torque within 0.25
N•m. Otherwise it may cause the case deformation or the bracket
damage.
• Make sure that foreign materials do not enter the inside of the
instrument through the case’s slit holes.
■External Dimensions and Panel Cutout Dimensions
(25)
(53) (2.09)
[(N-1)×96+92]
117 (4.61) min.
145 (5.71)
min.
+0.8
0
+0.8
0
92
“N” stands for the number of controllers to be
installed.
However, the measured value applies if N≥5.
65 (2.56)
20 (0.79)
11
(0.43)
UT75A
1 to 10 mm (0.04 to 0.39 inch) (panel thickness)
Bracket
Bracket
94.6 (3.72)
91.6 (3.61)
105.2 (4.14)
Unit: mm (approx. inch)
96 (3.78)
96 (3.78)
• General mounting • Side-by-side close mounting
Terminal cover
Normal tolerance:
±(value of JIS B 0401-1998 tolerance class IT18)/2
+0.8
0
92
+0.03
0
(3.62 )
(0.98)
+0.03
0
(3.62 )
+0.8
0
92
+0.03
0
(3.62 )
([(N-1)×3.78+3.62] )
+0.03
0
4. HardwareSpecications
WARNING
This instrument is for Measurement Category No.1.
Do not use it for measurements in locations falling under Measure-
ment Categories No.2, No.3, and No.4.
Internal Wiring
Outlet
Entrance
IV
Cable
III T
O( I )
II
Category IEC/EN/CSA/UL
61010-1 EN 61010-2-030 Remarks
No.1 Measurement
CategoryI O(Other) For measurements performed on circuits not
directlyconnectedtoMAINS.
No.2 Measurement
CategoryII
Measurement
CategoryII
For measurements performed on circuits directly
connectedtothelow-voltageinstallation.
No.3 Measurement
CategoryIII
Measurement
CategoryIII
Formeasurementsperformedinthebuildinginstal-
lation.
No.4 Measurement
CategoryIV
Measurement
CategoryIV
For measurements performed at the source of the
low-voltageinstallation.
■ InputSpecications
●UniversalInput(PV)
• Numberofinputs:1pointor2points(Type1code=-5)
• Inputtype,instrumentrange,andmeasurementaccuracy:Seethetablebelow,
Input Type Instrument Range Accuracy
ºC ºF
Thermo-
couple
K
-270.0to1370.0ºC -450.0to2500.0ºF ±0.1%ofinstrumentrange±1digitfor
0°Cormore
±0.2%ofinstrumentrange±1digitfor
lessthan0°C
±2%ofinstrumentrange±1digitfor
lessthan-200.0°CofthermocoupleK
±1%ofinstrumentrange±1digitfor
lessthan-200.0°CofthermocoupleT
-270.0to1000.0ºC -450.0to2300.0ºF
-200.0to500.0ºC -200.0to1000.0ºF
J-200.0to1200.0ºC -300.0to2300.0ºF
T
-270.0to400.0ºC -450.0to750.0ºF
0.0to400.0ºC -200.0to750.0ºF
B0.0to1800.0ºC 32to3300ºF
±0.15%ofinstrumentrange±1digit
for400°Cormore
±5%ofinstrumentrange±1digitfor
lessthan400°C
S0.0to1700.0ºC 32to3100ºF ±0.15%ofinstrumentrange±1digit
R 0.0to1700.0ºC 32to3100ºF
N -200.0to1300.0ºC -300.0to2400.0ºF
±0.1%ofinstrumentrange±1digit
±0.25%ofinstrumentrange±1digit
forlessthan0°C
E -270.0to1000.0ºC -450.0to1800.0ºF ±0.1%ofinstrumentrange±1digitfor
0°Cormore
±0.2%ofinstrumentrange±1digitfor
lessthan0°C
±1.5%ofinstrumentrange±1digitfor
lessthan-200.0°CofthermocoupleE.
L -200.0to900.0ºC -300.0to1600.0ºF
U
-200.0to400.0ºC -300.0to750.0ºF
0.0to400.0ºC -200.0to1000.0ºF
W 0.0to2300.0ºC 32to4200ºF ±0.2%ofinstrumentrange±1digit
(Note2)
Platinel 2 0.0to1390.0ºC 32.0to2500.0ºF ±0.1%ofinstrumentrange±1digit
PR20-40 0.0to1900.0ºC 32to3400ºF
±0.5%ofinstrumentrange±1digitfor
800°Cormore
Accuracyisnotguaranteedforless
than800°C.
W97Re3-
W75Re25 0.0to2000.0ºC 32to3600ºF ±0.2%ofinstrumentrange±1digit
RTD
JPt100 -200.0to500.0ºC -300.0to1000.0ºF ±0.1%ofinstrumentrange±1digit
(Note1)
-150.00to150.00ºC -200.0to300.0ºF ±0.1%ofinstrumentrange±1digit
Pt100
-200.0to850.0ºC -300.0to1560.0ºF ±0.1%ofinstrumentrange±1digit
(Note1)
-200.0to500.0ºC -300.0to1000.0ºF
-150.00to150.00ºC -200.0to300.0ºF ±0.1%ofinstrumentrange±1digit
Standardsignal
0.400to2.000V
±0.1%ofinstrumentrange±1digit
1.000to5.000V
4.00to20.00mA
DCvoltage/current
0.000to2.000V
0.00to10.00V
0.00to20.00mA
-10.00to20.00mV
0.0to100.0mV
Theaccuracyisthatinthestandardoperatingconditions:23±2°C,55±10%RH,andpowerfrequencyat50/60Hz.
Note1: ±0.3°C±1digitintherangebetween0and100°C,±0.5°C±1digitintherangebetween
-100and200°C.
Note2: W:W-5%Re/W-26%Re(HoskinsMfg.Co.).ASTME988
•Inputsampling(control)period:Selectfrom50,100,and200ms
• Burnout detection:
FunctionsatTC,RTD,andstandardsignal.
Upscale,downscale,andoffcanbespecied.
Forstandardsignal,burnoutisdeterminedtohaveoccurredifitis0.1Vor0.4mA
or less.
•Inputbiascurrent:0.05µA(forTCorRTD)
•Measuredcurrent(RTD):About0.16mA
• Input resistance:
TCormVinput:1MΩormore
Vinput:About1MΩ
mAinput:About250Ω
•Allowablesignalsourceresistance:
TCormVinput:250Ωorless
Effectsofsignalsourceresistance:0.1µV/Ωorless
DCvoltageinput:2kΩorless
Effectsofsignalsourceresistance:About0.01%/100Ω
• Allowablewiringresistance:
RTDinput:Max.150Ω/wire(Theconductorresistancebetweenthethreewires
shallbeequal.)
Wiringresistanceeffect:±0.1ºC/10Ω
• Allowableinputvoltage/current:
TC,mV,mAandRTDinput:±10VDC
Vinput:±20VDC
mAinput:±40mA
• Noiserejectionratio:
Normalmode:40dBormore(at50/60Hz)
Commonmode:120dBormore(at50/60Hz)
For100-240VAC,thepowerfrequencycanbesetmanually.Automaticdetection
isalsoavailable.
For24VAC/DC,thepowerfrequencycanbesetmanually.
• Referencejunctioncompensationerror:
±1.0ºC(15to35ºC)
±1.5ºC(-10to15ºCand35to50ºC)
• Applicablestandards:JIS/IEC/DIN(ITS-90)forTCandRTD
●UniversalInput(PV2)(Type1code=-5)
• Inputtype,instrumentrange,andmeasurementaccuracy:Sameasuniversalinput
exceptthetablebelow.
Input Type Instrument Range Accuracy
°C °F
4-wireRTD
JPt100 -200.0to500.0°C -300.0to1000.0°F ±0.5°C±1digit
-150.00to150.00°C -200.0to300.0°F ±0.2°C±1digit
Pt100
-200.0to850.0°C -300.0to1560.0°F ±0.1%ofinstrumentrange±1
digit(Note1)
-200.0to500.0°C -300.0to1000.0°F ±0.5°C±1digit
-150.00to150.00°C -200.0to300.0°F ±0.2°C±1digit
Note1: ±0.5°C±1digitintherangebetween-200.0and500.0°C/-300.0and1000.0°F.
• Inputsampling(control)period:Sameasuniversalinput
•Burnoutdetection:Sameasuniversalinput
●AuxiliaryAnalogInput(Type2code=1,2or3)
• Use:Remotesetpointsetting,externalcompensatinginput,auxiliaryinputforcom-
putation,etc.
• Numberofinputs:SeethetableofModelandSufxCodes.
• Inputtype,instrumentrange,andmeasurementaccuracy:Seethetablebelow.
Input Type Instrument Range Accuracy
Standardsignal 0.400to2.000V ±0.2%ofinstrumentrange±1digit
1.000to5.000V ±0.1%ofinstrumentrange±1digit
DCvoltage 0.000to2.000V ±0.2%ofinstrumentrange±1digit
0.00to10.00V ±0.1%ofinstrumentrange±1digit
DCvoltage
forhigh-input
impedance 0.000to1.250V ±0.1%ofinstrumentrange±1digit
• Inputsampling(control)period:Sameasuniversalinput
• Inputresistance:About1MΩ
However,10MΩormoreforDCvoltageforhigh-inputimpedancerange
•Burnoutdetection:Functionsatstandardsignal
Burnoutisdeterminedtohaveoccurredifitis0.1Vorless.
■ ContactInputSpecications
• Numberofinputs:SeethetableofModelandSufxCodes.
• Inputtype:No-voltagecontactinputortransistorcontactinput
• Inputcontactrating:12VDC,10mAormore
Useacontactwithaminimumon-currentof1mAormore.
• ON/OFFdetection:
No-voltagecontactinput:
Contactresistanceof1kΩorlessisdeterminedas“ON”andcontactresistance
of50kΩormoreas“OFF.”
Transistor contact input:
Inputvoltageof2Vorlessisdeterminedas“ON”andleakagecurrentmustnot
exceed100µAwhen“OFF.”
• Minimumstatusdetectionholdtime:Controlperiod+50ms
• Use:SPswitch,operationmodeswitch,andeventinput
■ AnalogOutputSpecications
• Numberofoutputs:
Controloutput:1point(standard),whichissharedwithtransmissionoutput.
Loop-2controloutput:1point,whichissharedwithtransmissionoutput.
• Outputtype:Currentoutputorvoltagepulseoutput
• Currentoutput:4to20mADCor0to20mADC/loadresistanceof600Ωorless
• Currentoutputaccuracy:±0.1%ofspan(±5%ofspanfor1mAorless)
Theaccuracyisthatinthestandardoperating conditions: 23±2°C,55±10%RH,
andpowerfrequencyat50/60Hz.
• Voltagepulseoutput:
Use:Timeproportionaloutput
On-voltage:12Vormore/loadresistanceof600Ωormore
Off-voltage:0.1VDCorless
Timeresolution:10msor0.1%ofoutput,whicheverislarger
■
RetransmissionOutputSpecications
• Numberofoutputs:1point(standard),whichissharedwith15VDClooppower
supply
• Currentoutput:4to20mADCor0to20mADC/loadresistanceof600Ωorless
• Currentoutputaccuracy(conversionaccuracyfromPVdisplay on the setscale):
±0.1%ofspan(±5%ofspanfor1mAorless)
Theaccuracyisthatinthestandardoperatingconditions:23±2°C,55±10%RH,
andpowerfrequencyat50/60Hz.
Thisisnotconversionaccuracythroughinputandoutputbutthe performance of
transmission output itself.
■
15VDCLoopPowerSupplySpecications
(Sharedwithretransmissionoutput)
• Powersupply:14.5to18.0VDC
• Maximumsupplycurrent:About21mA(withshort-circuitcurrentlimitingcircuit)
■ StepResponseTimeSpecications
Within500ms(whenthecontrolperiodis50msor100ms)
Within1s(whenthecontrolperiodis200ms)
(63%ofanalogoutputresponsetimewhenastepchangeof10to90%ofinputspan
isapplied)
■ RelayContactOutputSpecications
• Contacttypeandnumberofoutputs:
Controlrelayoutput:one1c-contactpoint
Loop-2controlrelayoutput:one1c-contactpoint
Alarmoutput:31a-contactpoints(Commonisseparated)
• Contactrating:
Contactpoint1c(controloutput):250VAC,3Aor30VDC,3A(resistanceload)
Contactpoint1a(alarmoutput):240VAC,1Aor30VDC,1A(resistanceload)
Note:Thecontroloutputshouldalwaysbeusedwithaloadof10mAormore.
Thealarmoutputshouldalwaysbeusedwithaloadof1mAormore.
• Use:Timeproportionaloutput,alarmoutput,FAILoutput,etc.
• Timeresolutionofcontroloutput:10msor0.1%ofoutput,whicheverislarger
■ TransistorContactOutputSpecications
• Numberofoutputs:SeethetableofModelandSufxCodes.
• Outputtype:Opencollector(SINKcurrent)
• Outputcontactrating:Max.24VDC,50mA
• Outputtimeresolution:Min.50ms
• Use:Alarmoutput,FAILoutput,etc.
■ PositionProportionalOutputSpecications
• Positionsignalinput:
Slideresistance:100Ωto2.5kΩoftotalresistance
100%sideandslideline:withdisconnectiondetection
0%side:withoutdisconnectiondetection
Currentinput:4to20mA(withdisconnectiondetection)
• Samplingperiod:50ms
• Measurementresolution:0.1%ofinputspan
• Position proportional relay output:
Contactpoint1a;2points,250VAC,3Aor30VDC,3A(resistanceload)
Note:Thisshouldalwaysbeusedwithaloadof10mAormore.
■ SafetyandEMCStandards
• Safety:
CompliantwithIEC/EN61010-1(CE),IEC/EN61010-2-201(CE),IEC/EN61010-
2-030(CE),approvedbyCAN/CSAC22.2No.61010-1(CSA),approvedbyUL
61010-1.
Installationcategory:II
Pollutiondegree:2
Measurementcategory:I(CATI)(UL,CSA)
O(Other)(CE)
Ratedmeasurementinputvoltage:Max.10VDC
Ratedtransientovervoltage:1500V(*)
*ThisisareferencesafetystandardvalueformeasurementcategoryIofCSA/UL61010-
1,andformeasurementcategoryOofIEC/EN61010-2-030.Thisvalueisnotnecessarilya
guaranteeofinstrumentperformance.
• EMCstandards:
CompliantwithCEmarking
EN61326-1ClassA,Table2(Foruseinindustriallocations),
EN61326-2-3
*Theinstrumentcontinuestooperateatameasurementaccuracyofwithin±20%ofthe
rangeduringtesting.
EN55011ClassA,Group1
EN61000-3-2ClassA
EN61000-3-3
EMCRegulatoryArrangementinAustraliaandNewZealand(forallmodelinclud-
ingLL50A)
EN55011ClassA,Group1
• KCmarking:
Electromagneticwaveinterferencepreventionstandard,electromagneticwave
protection standard compliance
■ Construction,Installation,andWiring
• Dust-proofanddrip-proof:IP66(forfrontpanel)(Notavailableforside-by-side
closemounting.)
• Material:Polycarbonate(Flameretardancy:UL94V-0)
• Casecolor:White(Lightgray)orBlack(Lightcharcoalgray)
• Weight:0.5kgorless
• Externaldimensions(mm):96(W)×96(H)×65(depthfromthepanelface)
(Depthexcepttheprojectionontherearpanel)
• Installation:Directpanelmounting;mountingbracket,oneeachforupperand
lowermounting
• Panelcutoutdimensions(mm):92+0.8/0(W)×92+0.8/0(H)
•
Mountingattitude:Upto30degreesabovethehorizontal.Nodownwardtitlingallowed.
• Wiring:M3screwterminalwithsquarewasher(forsignalwiringandpowerwiring)

IM 05P01B41-11EN page 3/14
■ PowerSupplySpecicationsandIsolation
• Power supply:
Ratedvoltage:100-240VAC(+10%/-15%),50/60Hz
24VAC/DC(+10%/-15%)(for/DCoption)
• Powerconsumption:18VA(DC:9VA,AC:14VAif/DCoptionisspecied)
• Databackup:Nonvolatilememory
• Powerholduptime:20ms(for100VACdrive)
• Withstandingvoltage
Betweenprimaryterminalsandsecondaryterminals:2300VACfor1minute(UL,CSA)
Betweenprimaryterminalsandsecondaryterminals:3000VACfor1minute(CE)
Betweenprimaryterminals:1500VACfor1minute
Betweensecondaryterminals:500VACfor1minute
(Primaryterminals:Power*andrelayoutputterminals;Secondaryterminals:
AnalogI/Osignalterminals,contactinputterminals,communicationterminals
andfunctionalgroundingterminals.)
*:Powerterminalsfor24VAC/DCmodelsarethesecondaryterminals.
• Insulationresistance:Betweenpowersupplyterminalsandagroundingterminal
20MΩormoreat500VDC
• Isolationspecications
The circuits divided by lines are insulated mutually.
Control and transmission (analog) output terminal
(not isolated between the analog output terminals)
Valve position (feedback) input terminal
Aux. analog (AIN2) input terminals
Aux. analog (AIN4) input terminals/remote input terminals
PV (universal) input terminal
PV2 (universal) input terminal
Control relay (c-contact) output terminal
Alarm-1 relay (a-contact) output terminal
Alarm-2 relay (a-contact) output terminal
Alarm-3 relay (a-contact) output terminal
Position proportional relay output terminal
Internal
circuits
Power
supply
Contact input terminal (All)
RS485 communication terminal (2 ports)
Ethernet/PROFIBUS-DP/CC-Link/DeviceNet
communication terminal
Contact output (transistor) terminal
■ EnvironmentalConditions
Normal Operating Conditions:
• Ambienttemperature:-10to50°C(side-by-sidemounting:-10to40°C)
0to50°CiftheCC-Linkoptionisspecied.(side-bysidemounting:0to40°C)
• Ambienthumidity:20to90%RH(nocondensationallowed)
• Magneticeld:400A/morless
• Continuousvibrationat5to9Hz:Halfamplitudeof1.5mmorless,1oct/minfor90
minuteseachinthethreeaxisdirections
Continuousvibrationat9to150Hz:4.9m/s2orless,1oct/minfor90minuteseach
inthethreeaxisdirections
• Short-periodvibration:14.7m/s2,15secondsorless
• Shock:98m/s2orless,11ms
• Altitude:2000morlessabovesealevel
• Warm-uptime:30minutesormoreafterthepoweristurnedon
• Startuptime:Within10seconds
*:TheLCD(aliquidcrystaldisplay)isusedforadisplayportionofthisproduct.TheLCDhasa
characteristicthatthedisplayactionbecomeslateatthelowtemperature.However,the
control fuction is not affected.
Transportation and Storage Conditions:
• Temperature:-25to70ºC
• Temperaturechangerate:20ºC/horless
• Humidity:5to95%RH(nocondensationallowed)
Effects of Operating Conditions
• Effectofambienttemperature:
VoltageorTCinput:±1µV/ºCor±0.01%ofF.S./ºC,whicheverislarger
Currentinput:±0.01%ofF.S./ºC
RTDinput:±0.05ºC/ºC(ambienttemperature)orless
Analogoutput:±0.02%ofF.S./ºCorless
• Effectofpowersupplyvoltageuctuation
Analoginput:±0.05%ofF.S.orless
Analogoutput:±0.05%ofF.S.orless
(Eachwithinratedvoltagerange)
5. How to Connect Wires
WARNING
• Wiring work must be carried out by a person with basic electrical
knowledge and practical experience.
• Be sure to turn OFF the power supply to the controller before
wiring to avoid an electric shock. Use a tester or similar device
to ensure that no power is being supplied to a cable to be
connected.
• For the wiring cable, the temperature rating is 75 °C or more.
• As a safety measure, always install a circuit breaker (an IEC
60947-compatibleproduct,5A, 100 V or220VAC)inan easily
accessible location near the instrument. Moreover, provide
indication that the switch is a device for turning off the power to
the instrument.
• Install the power cable keeping a distance of more than 1 cm
from other signal wires.
• The power cable is required to meet the IEC standards concerned
or the requirements of the area in which the instrument is being
installed.
• Wiring should be installed to conform to NEC (National Electrical
Code: ANSI/NFPA-70) or the wiring construction standards in
countries or regions where wiring will be installed.
• Since the insulation provided to each relay output terminal is
Functional insulation, provide Reinforced insulation to the
external of the device as necessary. (Refer to the drawing below.)
This product
Functional
insulation
A safety
voltage circuit
A safety
voltage circuit
This product
Reinforced insulation
Reinforced insulation
Functional
insulation
A hazardous
voltage circuit
A hazardous
voltage circuit
A safety
voltage circuit
A safety
voltage circuit
This product
Reinforced insulation
Reinforced insulation
Functional
insulation
A hazardous
voltage circuit
A hazardous
voltage circuit
A hazardous
voltage circuit
A hazardous
voltage circuit
CAUTION
• When connecting two or more crimp-on terminal lugs to the
single terminal block, bend the crimp-on terminal lugs before
tightening the screw.
• Note that the wiring of two or more crimp-on terminal lugs to the
single high-voltage terminal of the power supply and relay, etc.
does not comply with the safety standard.
CAUTION
• Provide electricity from a single-phase power supply. If the
power is noisy, install an isolation transformer on the primary
side, and use a line filter on the secondary side. When measures
against noise are taken, do not install the primary and secondary
power cables close to each other.
• If there is a risk of external lightning surges, use a lightning
arrester etc.
• For TC input, use shielded compensating lead wires for wiring.
For RTD input, use shielded wires that have low conductor
resistance and cause no significant differences in resistance
between the three wires.
• Since the control output relay has a life span (resistance load of
100,000 times), use the auxiliary relay to perform ON/OFF control.
• The use of inductance (L) loads such as auxiliary relays, motors
and solenoid valves causes malfunction or relay failure; always
insert a CR filter for use with alternating current or a diode for
use with direct current, as a spark-removal surge suppression
circuit, into the line in parallel with the load.
• After completing the wiring, the terminal cover is recommended
to use for the instrument.
● RecommendedCrimp-onTerminalLugs
(A)
(F)
(ød)
5.5
3.3
Recommendedtighteningtorque:0.6N·m
Applicablewiresize:Powersupplywiring1.25mm2or more
Applicable terminal lug Applicable wire size mm2(AWG#) (φd) (A) (F)
M3 0.25to1.65(22to16) 3.3 5.5 4.2
● CableSpecicationsandRecommendedCables
Purpose Name and Manufacturer
Powersupply,relaycontactoutputs 600VGradeheat-resistantPVCinsulatedwires,JISC
3317(HIV),0.9to2.0mm2
Thermocouple Shieldedcompensatingleadwires,JISC1610
Forthermocoupleinput(PVinputandremoteinputwithdirect
input),shieldedcompensatingleadwireofcross-sectionalarea
lessthanorequalto0.75mm2isrecommended.Ifthecross-
sectionalareaiswide,thereferencejunctioncompensation
errormaybelarge.
RTD Shieldedwires(three/fourconductors),UL2482(HitachiCable)
Othersignals(otherthancontactinput/output)
Shielded wires
Othersignals(contactinput/output)
Unshieldedwires
RS-485communication
Shielded wires
Ethernetcommunication
100BASE-TX(CAT-5)/10BASE-T
PROFIBUS-DPcommunication
DedicatedcableforPROFIBUS-DP(Shieldedtwo-wires)
DeviceNetcommunication
DedicatedcableforDeviceNet(Shieldedve-wires)
CC-Linkcommunication
DedicatedcableforCC-Link(Shieldedthree-wires)
PROFIBUS-DP/CC-LinkConnector(wiringside)(Partnumber:A1987JT)
DeviceNetConnector(wiringside)(Partnumber:L4502BW)
Recommendedtighteningtorque:0.5to0.6N·m
DC Relay Wiring
R
External DC power supply
Relay
UT75A
UT’s contact
Diode
(Mount it directly
to the relay coil
terminal (socket).)
Relay
(Use one with a relay coil rating
less than the UT’s contact rating.)
AC Relay Wiring
UT75A
R
UT’s contact
CR filter
(Mount it directly
to the relay coil
terminal (socket).)
External AC power supply
Relay
(Use one with a relay coil
rating less than the UT’s
contact rating.)
Transistor Output Wiring
power
+ –
UT
DO
Load
COM
6. Terminal Wiring Diagrams
CAUTION
• Do not use an unassigned terminal as the relay terminal.
• Donot use a 100-240 VACpowersupplyfor the 24 VAC/DC
model; otherwise, the instrument will malfunction.
■ UT75A
E4-terminal area
E3-terminal area E2-terminal area
PV RET
OUT
DI
VALV
ALM
OUT
OUT2
OUT2
E1-terminal area
Retransmission output
4-20 mA DC or
0-20 mA DC
15 V DC loop power supply
14.5-18.0 V DC
(Max. 21 mA DC)
+
-
+
-
Default: 4-20 mA DC
Default: PV
retransmission
Load resistance 600 Ωor less
Retransmission output
Current/voltage pulse output
0-20 mA DC,
4-20 mA DC,
Voltage pulse (12 V)
+
Retransmission output
+
-
Default: 4-20 mA DC
Default: Undefined
0-20 mA DC,
4-20 mA DC
Control output
PV input
TC input RTD input
Voltage (mV, V) input
A
+
-
+
-
Current (mA) input
+
-
B
b
(Suffix code: Type1=-1)
(Suffix code: Type 1=-5)
(Suffix code: Type1=-0, -1 or -5)
(Suffix code:
Type1=-0 or -5)
(24 V AC/DC power supply: Optional suffix code /DC)
(Equipped as standard)
(Equipped
as standard)
(Equipped
as standard)
(Equipped as standard)
Power supply
Contact input
Contact rating: 12 V DC, 10 mA or more
External contact input
DI3
DI2
DI1
COM
AUTO when DI1=ON
MAN when DI1=OFF
STOP when DI2=ON
RUN when DI2=OFF
Common
DI3
DI2
DI1
COM
+5V
+5V
+5V
No-voltage
contact Transistor contact
Factory default: No function
UT UT
Control output
101
102
Relay contact output
103
NC
NO
COM
Contact rating: 250 V AC, 3 A
30 V DC, 3 A (resistance load)
Contact output
101
102
103
104
105
106
107
108
109
110
111
501
502
503
504
505
506
507
508
509
510
511
512
407
401
408
409
410
411
412
301
302
303
304
305
306
307
308
309
310
311
312
201
202
203
204
205
206
207
208
209
210
211
212
Current/voltage pulse output
0-20 mA DC,
4-20 mA DC,
Voltage pulse (12V)
+
-
Retransmission output
+
-
Default: 4-20 mA DC
Default: Undefined
0-20 mA DC,
4-20 mA DC
Cooling-side control output
Relay contact output
NC
NO
COM
Contact rating: 250 V AC, 3 A
30 V DC, 3 A (resistance load)
Position proportional control output
Resistance: 100 Ωto 2.5 kΩ
Feedback input
100%
0%
101
-112
501
-512
401
-412
301
-312
201
-212
External contact output (relay)
AL3
AL2
AL1
Relay contact rating: 240 V AC, 1 A
30 V DC, 1 A (resistance load)
Alarm-3 output
(PV high limit)
Alarm-2 output
( PV low limit)
Alarm-1 output
(PV high limit)
Common
Common
Common
UT
104
105
106
107
108
109
100-240 V AC power supply
N
L
Allowable range:
100-240 V AC (+10%/-15%)
(free voltage)
50/60 Hz shared
110
111
24 V AC/DC power supply
-
+
110
111
Relay contact output
HIGH
(direct)
LOW
(reverse)
COM
Contact rating: 250 V AC, 3A
30 V DC, 3 A
(resistance load)
507
508
509
510
511
512
-
Feedback input
Current (mA)
input
When feedback input is current
510
511
512
202
203
201
202
203
202
203
203
204
205
206
205
206
15 V DC loop power supply
14.5-18.0 V DC
(Max. 21 mA DC)
+
-
207
208
15 V DC loop power supply
14.5-18.0 V DC
(Max. 21 mA DC)
+
-
511
512
207
-208
207
208
209
210
211
212
209
210
211
212
507
508
509
511
512
511
512
Factory default: PV input
type is undefined.
Can be used for retransmission output or 15 V DC loop power supply when
current/voltage pulse output is not used for control output.
Current output range can be changed.
In Position proportional type, can be used for retransmission output or 15 V
DC loop power supply.
Can be used for retransmission output or 15 V
DC loop power supply when current/voltage
pulse output is not used for control output.
Current output range can be changed.
Can be used for 15 V DC loop
power supply when not used for
retransmission output.
Function can be assigned to the terminals with no function.
+
112
112 112
N
L
Do not use a 100-240 V AC power
supply for the 24 V AC/DC model;
otherwise, the instrument will
malfunction.
CAUTION
Wiring direction

IM 05P01B41-11EN page 4/14
E1-Terminal Area
301-306 E2-Terminal Area
307-312
Contact output
External contact output
Transistor contact rating: 24 V DC, 50 mA
DO22
DO21
DO23
DO24
DO25
COM
Common
UT
(Suffix code: Type 2=0, 1 or 2)
307
308
309
310
311
312
Function can be assigned
to the terminals with no
function.
DO
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
(Suffix code: Type 2=2)
Aux. analog input
Default: 1-5 V DC
+
-
Aux. analog input / Contact input
External contact input
DI26
COM
Common
DI26
COM
+5V
No-voltage contact
Transistor contact
Contact rating: 12 V DC, 10 mA or more
Factory default: No function
UT UT
309
310
309
310
311
312
Aux. analog input can be used for
feedforward input in Single-loop control and
Single-loop position proportional control.
Function can be assigned
to the terminals with no
function.
AIN2
Specify within a
range of 1-5 V DC,
0-2 V DC,0-10 V DC
(Suffix code: Type 1=-5)
PV2
PV2 input
TC input RTD input
Voltage (mV, V) input
A
+
-
+
-
Current (mA) input
+
-
B
b
302
303
301
302
303
302
303
303
304
E4-terminal area
E3-terminal area
E2-terminal area
E1-terminal area
101
102
103
104
105
106
107
108
109
110
111
501
502
503
504
505
506
507
508
509
510
511
512
407
401
408
409
410
411
412
301
302
303
304
305
306
307
308
309
310
311
312
201
202
203
204
205
206
207
208
209
210
211
212
101
-112
501
-512
401
-412
301
-312
201
-212
112
(Suffix code: Type 2=3)
Contact input
External contact input
DI11
DI12
DI13
DI14
DI15
COM
Common
DI11
DI12
COM
+5V
+5V
No-voltage contact
Transistor contact
Contact rating: 12 V DC, 10 mA or more
DI13 +5V
DI14 +5V
DI15 +5V
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
UT UT
301
302
303
304
305
306
301
302
303
304
305
306
Function can be assigned to the
terminals with no function.
DI
E3-Terminal Area
401-412 E4-Terminal Area
501-506
(Suffix code: Type 3=2)
Ethernet communication (with gateway function)
10BASE-T/100BASE-TX
RJ45 connector
Color
Lit
Unlit
Amber
100M bps
10M bps
Green
Linked
Active
Link failure
Color
Lit
Blink
Unlit
Upper side LED (baud rate)
Lower side LED (link activity)
RS-485
RSB(+)
RSA(-)
SG
407
408
409
ETHR
Contact input
External contact input
DI41
DI42
DI43
DI44
DI45
COM
DI41
DI42
COM
+5V
+5V
DI43 +5V
DI44 +5V
DI45 +5V
UT UT
(Suffix code: Type 2=0)
Common
No-voltage contact
Transistor contact
Contact rating: 12 V DC, 10 mA or more
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
501
502
503
504
505
506
501
502
503
504
505
506
Function can be assigned to the
terminals with no function.
DI
PROFIBUS-DP communication (with Modbus master)
Pin
1
2
Signal name Description
VP
RxD/TxD-P
3RxD/TxD-N
4DGND
5SHIELD
+5V bus power
Data signal
(positive data receive/transmit)
Data signal
(negative data recive/transmit)
Signal ground
Shield ground
RS-485
RSB(+)
RSA(-)
SG
407
408
409
PROF
If the UT is located at
the end of a segment
for the PROFIBUS
communication wiring,
terminating resistors
are separately
needed.
These are to be
prepared by users.
(390 Ω: 2 pcs. 220 Ω:
1 pc., or an active
terminator.)
VP
RxD/TxD-P
Data
line
Data
line
390Ω
220Ω
390Ω
RxD/TxD-N
DGND
CHK
RDY
ERR
LED
CHK
(red)
RDY
(green)
Lit Unlit
ERR
(red)
User profile error Normal
Normal
Not connected, or
communication
failure (flashing)
Normal
Communicating
successfully
No power, or
Communication
failure
(Suffix code: Type 3=4)
1
2
3
4
5
RS-485 communication/Contact input
RS485/DI
SDB(+)
SDA(-)
SG
RDB(+)
RDA(-)
(Suffix code: Type 3=1)
1
2
3
4
5
External contact input
DI31
DI32
DI33
DI34
DI35
COM
DI31
DI32
COM
+5V
+5V
DI33 +5V
DI34 +5V
DI35 +5V
UT UT
Common
No-voltage contact
Transistor contact
Contact rating: 12 V DC, 10 mA or more
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
Factory default: No function
407
408
409
410
411
412
407
408
409
410
411
412
Function can be assigned to the
terminals with no function.
(Suffix code: Type 3=3)
CC-Link communication (with Modbus master)
RS-485
RSB(+)
RSA(-)
SG
407
408
409
CC-L
If the UT is located at
the end of a segment
for the CC-Link
communication wiring,
terminating resistors
are separately needed.
These are to be
prepared by users.
(110 Ω: 1 pc.)
DA
DB
110Ω
LED
CHK
(red)
L ERR
(red)
L RUN
(green)
Lit Unlit
CHK
L RUN
L ERR
User profile error/
Address error Normal
Normal
Pin
1
2
Signal name Description
DA
DB
3DG
4
SLD
5
FG
RX/TX + signal
RX/TX - signal
Frame ground
RX/TX signal ground
Shield
Normal
Communicating successfully
Communication failure
(CRC error)
No carrier
detected/
Connection
timeout
1
2
3
4
5
(Suffix code: Type 3=5)
DeviceNet communication (with Modbus master)
RS-485
RSB(+)
RSA(-)
SG
407
408
409
DNET
If the UP is located at the
end of a segment for the
DeviceNet
communication wiring,
terminating resistors are
separately needed.
These are to be
prepared by users. (121
Ω: 1 pc.)
CAN_H
CAN_L
121Ω
LED
CHK
(red)
MNS
(green/
red)
Lit/flashing Unlit
User profile error Normal
Pin
1
2
Signal name Description
CAN_H
CAN_L
3
V+
4
V-5
DRAIN
RX/TX + signal
RX/TX - signal
Shield/Drain wire
DeviceNet power supply 24V
DeviceNet power supply common
Normal. Communicating
successfully (green, lit).
Not connected (green, flashing).
Critical link failure (red, lit).
Communication timeout (red,
flashing)
At power-on/Communication
faulted (green/red, flashing)
No electricity
CHK
MNS
1
2
3
4
5
(Suffix code: Type 2=1 or 2)
RS-485
RSB(+)
RSA(-)
SG
RS-485 communication / Remote input / Contact input
Default: 1-5 V DC
+
-
External contact input
DI46
COM
Common
DI46
COM
+5V
No-voltage contact
Transistor contact
Contact rating: 12 V DC, 10m A or more
UT UT
501
502
503
503
504
503
504
505
506
AIN4/RS485
Specify within a
range of 1-5 V DC,
0-2 V DC,0-10 V DC
REMOTE when DI46=ON
LOCAL when DI46=OFF
Aux. analog input
Aux. analog input
Default: 1-5 V DC
+
-
Aux. analog input/Contact input
External contact input
DI46
COM
DI46
COM
+5V
UT UT
(Suffix code: Type 2=3)
Common
No-voltage contact
Transistor contact
Contact rating: 12 V DC, 10 mA or more
Factory default: No function
503
504
503
504
505
506
Function can be assigned to the
terminals with no function.
AIN4
Aux. analog input can be used for feedforward input in
Single-loop control and Single-loop position proportional
control.
Specify within a
range of 1-5 V DC,
0-2 V DC,0-10 V DC
■Errors at Power On
Theerrorsshownbelowmayoccurinthefaultdiagnosiswhenthepoweristurnedon.(FordetailsofSetpointdisplayandinput/outputactionwheneacherroroccurs,seeUser’sManual.
PVdisplay
(Operation
Display)
Setpoint display
(Operation Display)
Status indicator
(Operation Display)
Parameter that displays error
details Error description Cause and diagnosis Remedy
Indication off Indication off — — FaultyMCURAM/MCUROM MCURAM/MCUROMarefailed. Faulty.
Contactusforrepair.
ERR
SYS-----
—
— System data error System data is corrupted. Faulty.
Contactusforrepair.
PAR0004
(foruserdefaultvalueerror
only)
Setupparameter(PA.ER)
User(parameter)defaultvalue
error
Userparameteriscorrupted.
Initializedtofactorydefaultvalue.
Checkandreconguretheinitialized
settingparameters.Errorindicationis
erased when the power is turned on
again.
PAR0010
(forsetupparametererror
only)
Setup parameter error Setup parameter data is corrupted.
Initializedtouserdefaultvalue.
PAR0020
(foroperationparametererroronly)
Operationparametererror Operationparameterdataiscorrupted.
Initializedtouserdefaultvalue.
SLOT0017
(0017:Erroroccurstoall
hardwareofE1toE4-terminal
areas.)
Setupparameter(OP.ER)
Nonrespondinghardwareof
extendedfunction(E1toE4-
terminalareas)
Inconsistence of system data and
hardwareofextendedfunction.
Nonrespondingcommunicationbetween
hardwareofextendedfunction(E1toE4-
terminalareas).
Faulty.
Contactusforrepair.
Normal
indication Normalindication
Rightmostdecimalpoint
onPVdisplayblinks. Setupparameter(PA.ER)
Calibrationvalueerror
Initializedtocalibrateddefaultvaluebecause
ofcorruptedfactorydefaultvalue.
Faulty.
Contactusforrepair.
Rightmostdecimalpoint
onSymboldisplayblinks.
FaultyFRAM
Datawriting(storing)toFRAMisimpossible.
Normal
indication Normalindication LADDERlampblinks Setupparameter(LA.ER) Corruptedladderprogram Ladderprogramiscorrupted.
Operateswithoutladderprogram. Downloadtheladderprogramagain.
Normal
indication
0.00000000
(Decimalpointontheleftof
theSymboldisplayblinks)
—Setupparameter(OP.ER) Userproleerror Userproleiscorrupted. Downloadtheuserproleagain.
■Errors during Operation
Theerrorsshownbelowmayoccurduringoperation.(Forinput/outputactionwheneacherroroccurs,seeUser’sManual.
PVdisplay
(Operation
Display)
Setpoint display
(Operation Display)
Status indicator
(Operation Display)
Parameter that displays
error details Error description Cause and diagnosis Remedy
AD.ERR Normalindication(Note) —Setupparameter(AD1.E)
AnaloginputterminalADCerror
•PVinput
•PV2input(E1-terminalarea)
•AIN2input(E2-terminalarea)
•AIN4input(E4-terminalarea)
AnaloginputterminalADvalueerror Faulty.
Contactusforrepair.
RJC.E
(DisplaysRJC.
EandPV
alternately.)
Normalindication(Note) —Setupparameter(AD1.E)
UniversalinputterminalRJCerror
•PVinput
•PV2input(E1-terminalarea)
UniversalinputterminalRJCerror
Faulty.
Contactusforrepair.
SettheparameterRJCtoOFFtoerase
error indication.
B.OUT Normalindication(Note) —
Setupparameter(AD1.E)
Analoginputterminalburnouterror
•PVinput
•PV2input(E1-terminalarea)
•AIN2input(E2-terminalarea)
•AIN4input(E4-terminalarea)
Analoginputterminalsensorburnout
Checkwiringandsensor.
Errorindicationiserasedinnormal
operation.
Setupparameter(PV1.E/PV2.E) PVinputburnouterror(Loop1,
Loop2) BurnoutofanaloginputconnectedtoPV
Checkwiringandsensorofconnected
analoginputterminals.
Errorindicationiserasedinnormal
operation.
OVER
-OVER Normalindication —Setupparameter(PV1.E/PV2.E)
PVinputover-scale
PVinputunder-scale
(PVvaluesoutof-5to105%)(Loop
1,Loop2)
PVinputisoutof-5to105%.Alsooccurs
whenthedataoutofrangewhichisthe
ladder calculation result is input.
Checkanaloginputvalueorladder
program.
Normal
indication Normalindication —Setupparameter(PV1.E/PV2.E) AIN4inputburnouterror(Loop1,
Loop2) BurnoutofanaloginputconnectedtoRSP Checkwiringandsensor.Error
indication is erased in normal operation.
Normal
indication RSPB.OUT —Setupparameter(PV1.E/PV2.E)
BurnouterrorwhenAIN4inputis
usedforcontrol(Loop1,Loop2)
BurnoutofanaloginputconnectedtoRSP
whenRSPisusedforcontrolcomputation
Checkwiringandsensor.Error
indication is erased in normal operation.
Normal
indication OUT----- —Setupparameter(AD2.E) Feedbackinputresistor/current
burnout Feedbackinputburnout
Checkwiringoffeedbackinputresistor/
current.Errorindicationiserasedin
normal operation.
Normal
indication
Normalindication LADDERlampblinks Setupparameter(LA.ER)
Laddercalculationoverow Floatingpointcomputationforladder
calculationisinnite. Checktheladderprogram.
Loadfactorover100%
Computationdoesnotendwithinthe
controlperiod(loadfactoris100%or
more).
Changethecontrolperiodorreduce
thenumberofstepsfortheladder
program.
Loadfactorover200%
(Forcedend)
Computationdoesnotendwithinthecontrol
period(loadfactoris200%ormore).
Changethecontrolperiodorreducethe
numberofstepsfortheladderprogram.
Ladderprogramerror Ladderprogramiscorrupted.
Downloadtheladderprogramagain.If
theerrorindicationisstillnoterased,
thereisafault.Contactusforrepair.
0.00000000
(Decimalpointontheleftof
theSymboldisplayblinks)
—Setupparameter(OP.ER) Peer-to-peercommunicationerror Peer-to-peercommunicationerror
Checkthatthetargetdevicesare
connected correctly.
Recoveryatnormalreceipt.
AT.E Normalindication —Setupparameter(PV1.E/PV2.E) Auto-tuningtime-out
(Loop1,Loop2)
Auto-tuningdoesnotendevenwhen24
hourshaveelapsedafterthestartoftuning.
Checktheprocess.Holddownanykeyto
erase the error indication
VAT.E Normalindication —Setupparameter(AD2.E) Valvepositionautomatic
adjustmenterror
Fully-closedvalvepositionisequaltoorlarger
thanthefully-openvalvepositionafterautomatic
valvepositionadjustmentisperformed.
Checkwiringandvalve.Holddownany
key to erase the error indication.
Normal
indication
0.00000000
(Decimalpointontheleftof
theSymboldisplayblinks)
—Setupparameter(OP.ER) Communicationerror
(RS-485communication)
Framingparityerror
Bufferoverow
Inter-charactertime-out
Checksumerror(PClinkcommunicationwith
checksum)
CRCcheckerror(Modbus/RTU)
LRCcheckerror(Modbus/ASCII)
Checkthecommunicationparameters.
Recoveryatnormalreceipt.
Holddownanykeytostopblinking.
Normal
indication
0.00000000
(Decimalpointontheleftof
theSymboldisplayblinks)
—Setupparameter(OP.ER) Communicationerror
(coordinatedoperation)
Inconsistenceofloopbetweencoordinated
masterandslaves
Checkthecommunicationparameters.
Recoveryatnormalreceipt.Changefromremote
tolocalmodetostopblinking.
Whenthemodeischangedfromremoteto
local,SPtrackingdoesnotworkevenifitis
settoON.
Communicationfromcoordinatedmasteris
interrupted for 2 seconds.
Normal
indication
0.00000000
(Decimalpointontheleftof
theSymboldisplayblinks)
—Setupparameter(OP.ER) Userproleerror Userproleiscorrupted. Downloadtheuserproleagain.
Normal
indication Normalindication
Rightmostdecimalpointon
Symboldisplayblinks.
Setupparameter(PA.ER) FaultyFRAM
Writing(storing)datatoFRAMisimpossible.
Faulty.Contactusforrepair.
Undened Undened — — FaultyMCU/DCU
(ROM/RAMerror,corrupted) MCU/DCUiscorrupted. Faulty.Contactusforrepair.
Note:WhenanerroroccursininputshowninAnaloginputdisplay(Operationdisplay),SetpointdisplayshowsthesamesymbolasthePVdisplay.

IM 05P01B41-11EN page 5/14
Contents
1. NamesandFunctionsofDisplayParts
2. Setup Procedure
3. QuickSettingFunction(SettingofInputandOutput)
4.
AdjustingValvePositionAutomatically(foraPositionProportionalTypeControllerOnly)
5. SettingAlarmType
6. SettingAlarmSetpoint
7. OverviewofProgramPatterns
8. CreatingProgramPatterns
9. ProgramPatternSetupCharts
1. Names and Functions of Display Parts
(1)
(9)
(2)
(13)
(12)
(10)
(11)
(17)
(18)
(19)
(4)
(3)
(5)
(6)
(7)
(8)
(16)
(14)
(15)
(2)+(3)+(4):設定値表示部と呼びます。
No.ingure Name Description
(1) PVdisplay
(whiteorred)
DisplaysPV.Displaysanerrorcodeifanerroroccurs.
DisplaysthescrollingguideintheMenuDisplayandParameter
SettingDisplaywhentheguidedisplayON/OFFissettoON.
(2) Groupdisplay(green)
Displaysagroupnumber(1to16orR)andterminalarea(E1to
E4).1to20representSPnumbersintheOperationDisplay.
RandE1toE4aredisplayedintheParameterSettingDisplay.
IftheSELECTdisplayisregistered,Customdisplaynumber(C1to
C3)isdisplayed.
(3)
Symboldisplay(orange)
Displaysaparametersymbol.
(4) Datadisplay(orange) Displaysaparametersetpointandmenusymbol.
(5) Bar-graphdisplay
(orangeandwhite)
Displayscontroloutputvalue(OUT)andmeasuredinputvalue(PV).
Thedatatobedisplayedcanbesetbytheparameter.
Initialvalue:upperbar(deviation),lowerbar(controloutput,
internalcomputedvalueinPositionproportionalcontrol);
inHeating/coolingcontrol,upperbar(heating-sidecontroloutput),
lowerbar(cooling-sidecontroloutput)
(6) Eventindicator
(orange)
Litwhenthealarms1to8occur.(Initialvalue:1to4)
Eventdisplaysotherthanalarmscanbesetbytheparameter.
(7) Keynavigationindica-
tor(green)
LitorblinkswhentheUp/DownorLeft/Rightarrowkeyoperation
ispossible.
(8) Parameterdisplaylevel
indicator(green)
Displaysthesettingconditionsoftheparameterdisplaylevelfunction.
Parameter display level EASY PRO
Easysettingmode Lit Unlit
Standardsettingmode Unlit Unlit
Professionalsettingmode Unlit Lit
(9) Deviationindicator
(green)
Displaysthestatusofadeviation(PV-SP).
:Litifadeviationexceedsthedeviationdisplayband.
:Litwhenadeviationiswithinthedeviationdisplayband
:Litifadeviationfallsbelowthedeviationdisplayband.
ThedeviationindicatorisunlitiftheDisplaysotherthantheOp-
erationDisplayorSELECTDisplayareshown.Deviationdisplay
bandcanbesetbytheparameter.
(10) Status indicator
(greenandred)
Displaystheoperatingconditionsandcontrolstatus.
Indicator Description
REM Litwheninremotemode(REM).
CAS Litwhenincascademode(CAS).
PRG Litwheninprogrampatternoperationmode
(PRG).Blinksduringholdoperation.
STOP Litwheninstopmode(STOP).
MAN Litwheninmanualmode(MAN).
Blinksduringauto-tuning.
No.ingure Name Description
(11) Securityindicator(red) Litifapasswordisset.Thesetupparametersettingsarelocked.
(12) Ladderoperation
indicator(green)
Litwhiletheladderoperationisexecuted.
(13)
Loop2indicator
(LP2lamp)
(green)
LitwhenthecontrolmodeisCascadecontrolorDual-loopcontrol.
IntheOperationDisplay,theLP2lampislitwhiletheLoop-2data
is displayed on Setpoint display.
IntheParameterSettingDisplay,theLP2lampindicatesthe
loopofdisplayedmenusymbolorparametersymbol.TheLP2
lampislitwhiletheLoop-2menusymbolorparametersymbolis
displayed.
(14) DISPLAYkey
UsedtoswitchtheOperationDisplays.
PressthekeyintheOperationDisplaytoswitchtheprovided
OperationDisplays.
PressthekeyintheMenuDisplayorParameterSettingDisplay
toreturntotheOperationDisplay.
(15) PARAMETERkey
Holddownthekeyfor3secondstomovetotheOperation
ParameterSettingDisplay.
HolddownthekeyandtheLeftarrowkeysimultaneouslyfor3
secondstomovetotheSetupParameterSettingDisplay.
PressthekeyintheParameterSettingDisplaytoreturntothe
MenuDisplay.Pressthekeyoncetocanceltheparameterset-
ting(setpointisblinking).
(16)
SET/ENTERkey
Up/Down/Left/Right
arrow keys
SET/ENTERkey
PressthekeyintheMenuDisplaytomovetotheParameter
SettingDisplayoftheMenu.PressthekeyintheParameter
SettingDisplaytotransfertotheparametersettingmode
(setpointisblinking),andtheparametercanbechanged.
Pressthekeyduringparametersettingmodetoregisterthe
setpoint.
Up/Down/Left/Rightarrowkeys
PresstheLeft/RightarrowkeysintheMenuDisplaytoswitch
theDisplays.
PresstheUp/Down/Left/RightarrowkeysintheParameter
SettingDisplaytoswitchtheDisplays.
PresstheUp/Downarrowkeysduringparametersettingmode
(setpointisblinking)tochangeasetpoint.
PresstheLeft/Rightarrowkeysduringparametersettingmode
(setpointisblinking)tomovebetweendigitsaccordingtotheparameter.
(17) Light-loaderinterface
Itisthecommunicationinterfacefortheadaptercableusedwhen
settingandstoringparametersfromaPC.TheLL50AParameter
SettingSoftware(soldseparately)isrequired.
(18) A/Mkey
UsedtoswitchbetweenAUTOandMANmodes.
ThesettingisswitchedbetweenAUTOandMANeachtimethe
key is pressed.
(19) Userfunctionkeys
TheUT75AhasF1,F2,andFnkeys.
Theusercanassignafunctiontothekey.Thefunctionissetby
the parameter.
Note: Thecommunicationconnector(maintenanceport)forLL50AParameterSettingSoftwareis
on the top of the unit.
2. Setup Procedure
ThefollowingowchartshowsthesetupprocedureforUT75A.
Install and wire a controller.
Monitoring and control of regular operations
Adjust PID using auto-tuning or manually for PID control.
Other setup
Operation
NO
NO NO
YES
YES YES
Control mode: Single-loop control only
Set the other parameters as needed.
PID tuning
Input setup
Output setup
Installation
and wiring
Power ON
Control mode setup
Control type setup
Control type setup
Input/output setup
Valve position
adjustment
Use
Quick setting
function?
Position
proportional
type?
Position
proportional
type?
For Position proportional type
3.
Quick Setting Function (Setting of Input and Output)
TheQuicksettingfunctionisafunctiontoeasilysetthebasicfunctionofthecontroller.
TurnonthecontrollertostarttheQuicksettingfunction.
Thisfunctionallowsyoutoeasilysetthecontroltype,input,andoutput,andquickly
start the control action.
Theitems(parameters)tobesetbyQuicksettingfunctionareasfollows.
(1)Controltype(PIDcontrol,Heating/coolingcontrol,etc.)
(2)Inputfunction(PVinputtype,range,scale(atvoltageinput),etc.)
(3)Outputfunction(controloutputtypeandcycletime)
Afterturningonthecontroller,rstdecidewhetherornottousetheQuicksettingfunction.
TheQuicksettingfunctioncanbeusedonly when thecontrolmodeisSingle-loop
control.Forothercontrolmodes,setthefunctionswithoutusingthe Quick setting
function.
Operation in Initial Display
· PresstheSET/ENTERkeywhileYESisdisplayedtostarttheQuicksettingfunction.
· IfyouchangeYEStoNOandpresstheSET/ENTERkey,OperationDisplaywill
appearwithoutstartingtheQuicksettingfunction.
Operation
Guide
Initial Settings
UT75A
Digital Indicating Controller
Operation Guide for Single-loop Control
This operation guide describes basic settings and operations of the UT75A.
For details of each function, see the electronic manual contained.
The scrolling guide is displayed on PV display in the Parameter Setting Display.
This guide can be turned on/off with the Fn key.
For details of the each function, refer to the electronic manual. User
's manuals can be
downloaded or viewed at the following URL.
Functional
Enhancement
http://www.yokogawa.com/ns/ut/im/
Operation for Setting
· Toselecttheparametersettingdisplayedastheinitialvalue,presstheDownarrow
keytomovetothenextparameter.
· Tochangeandsettheparametersetting,presstheSET/ENTERkeytostartthe
setpointblinking.Theblinkingstateallowsyoutomakechanges(settingmode).
UsetheUp/Down/Left/Rightarrowkeystochangethesetpoint.PresstheSET/EN-
TERkeytoregisterthesetting.
■Making Settings Using Quick Setting Function
Example: Setting to PID control, thermocouple type K (range of 0.0 to 500.0°C),
and current control output
Forthedetailedprocedureandswitchingofdisplays,see"FlowofQuickSetting
Function"below.Fortheparameterstoset,seethenextpage.
(1)PresstheSET/ENTERkeywhileYESforQSM(Quicksettingmode)isdisplayed.
(2)Setthecontroltypeparameter(CNT)toPID(PIDcontrol).
(3)SetthePVinputtypeparameter(IN)toK1(-270.0to1370.0°C).
(4)SetthePVinputunitparameter(UNIT)toC(DegreeCelsius).
(5)SetthemaximumvalueofPVinputrangeparameter(RH)to500.0.
(6)SettheminimumvalueofPVinputrangeparameter(RL)to0.0.
(7)Settheoutputtypeselectionparameter(OT)toOUTterminals(current).
(8)Finally,EXITisdisplayed.ChangeNOtoYESandpresstheSET/ENTERkeyto
completethesetup.OperationDisplayappears.
Press the SET/ENTER key while YES
is displayed to start the Quick setting.
[NO]
Select NO with the Down
arrow key and press the
SET/ENTER key.
Select NO to return to
the Operation Display.
Power-on
First, the control type
parameter (CNT)
is displayed.
Initial value: PID (PID control)
Press the Down arrow key.
The PV input type
parameter (IN) is
displayed.
Initial value: OFF
Press the SET/ENTER key.
OFF blinks.
Blinking allows you to
change the setting.
Press the Up arrow key.
K1 is displayed.
K1 has been registered.
Press the SET/ENTER key.
Press the Down arrow key.
[YES]
1.
2.
3.
4.
5.
6.
Quick setting starts
The last digit of the upper limit value blinks.
The parameter RH (maximum value of PV input range)
has been changed to 500.0.
The setpoint for the parameter RH has been registered.
Press the Down arrow key.
Operation Display
8
.
9
.
10
.
1
1.
1
2.
The PV input unit parameter (UNIT) is displayed.
Initial value: C (Degree Celsius)
7.
Press the Down arrow key.
Follow the same procedure to set RL
to 0.0 and OT to 00.02.
Set other parameters as needed.
Displays the measured
input value (PV).
Displays the target
setpoint (SP).
Finally, EXIT is displayed.
Press the SET/ENTER key to swtich to the setting mode.
Change NO to YES and press the SET/ENTER key
to complete the setup of the basic function.
Operation Display appears.
The Quick setting function continues in the NO state.
The upper limit value of the setting range is displayed
for the parameter RH (maximum value of PV input range).
Press the SET/ENTER key.
Press the SET/ENTER key.
Change the setpoint using the Up/Down arrow keys
to increase and decrease the value and the Left/Right arrow
keys to move between digits.
■ FlowofQuickSettingFunction
InQuicksettingmode,theparameterguideappearsonPVdisplay.
Thisguidecanbeturnedon/offwiththeFnkey.

IM 05P01B41-11EN page 6/14
■ Parameterstobeset
Control Type
Parameter Symbol Name of Parameter Setting Range
CNT Controltype
PID:PIDcontrol
ONOF:ON/OFFcontrol(1pointofhysteresis)
ONOF2:ON/OFFcontrol(2pointsofhysteresis)
2P2L:Two-positiontwo-levelcontrol
H/C:Heating/coolingcontrol
S-PI:SamplePIcontrol
BATCH:BatchPIDcontrol
FFPID:Feedforwardcontrol
Note: Somesetpointsmaynotbedisplayeddependingonthemodelandsuffixcodes.
Input Function
Parameter Symbol Name of Parameter Setting Range
IN PVinputtype
OFF:Disable
K1:-270.0to1370.00C/-450.0to2500.0 0F
K2:-270.0to1000.00C/-450.0to2300.0 0F
K3:-200.0to500.00C/-200.0to1000.0 0F
J:-200.0to1200.00C/-300.0to2300.0 0F
T1:-270.0to400.00C/-450.0to750.0 0F
T2:0.0to400.00C/-200.0to750.0 0F
B:0.0to1800.00C/32to3300 0F
S:0.0to1700.00C/32to3100 0F
R:0.0to1700.00C/32to3100 0F
N:-200.0to1300.00C/-300.0to2400.0 0F
E:-270.0to1000.00C/-450.0to1800.0 0F
L:-200.0to900.00C/-300.0to1600.0 0F
U1:-200.0to400.00C/-300.0to750.0 0F
U2:0.0to400.00C/-200.0to1000.0 0F
W:0.0to2300.00C/32to4200 0F
PL2:0.0to1390.00C/32.0to2500.0 0F
P2040:0.0to1900.00C/32to3400 0F
WRE:0.0to2000.00C/32to3600 0F
JPT1:-200.0to500.00C/-300.0to1000.0 0F
JPT2:-150.00to150.000C/-200.0to300.0 0F
PT1:-200.0to850.00C/-300.0to1560.0 0F
PT2:-200.0to500.00C/-300.0to1000.0 0F
PT3:-150.00to150.000C/-200.0to300.0 0F
0.4-2V:0.400to2.000V
1-5V:1.000to5.000V
4-20:4.00to20.00mA
0-2V:0.000to2.000V
0-10V:0.00to10.00V
0-20:0.00to20.00mA
-1020:-10.00to20.00mV
0-100:0.0to100.0mV
UNIT PVinputunit -:Nounit,C:DegreeCelsius
-:Nounit,--:Nounit,---:Nounit,F:DegreeFahrenheit
RH Maximumvalueof
PVinputrange
Dependsontheinputtype.
-Fortemperatureinput-
Setthetemperaturerangethatisactuallycontrolled.
(RL<RH)
-Forvoltage/currentinput-
Settherangeofavoltage/currentsignalthatisapplied.
Thescaleacrosswhichthevoltage/currentsignalis
actuallycontrolledshouldbesetusingthemaximumvalue
ofinputscale(SH)andminimumvalueofinputscale(SL).
(Inputisalways0%whenRL=RH.)
RL Minimumvalueof
PVinputrange
SDP
PVinputscale
decimal point
position
0:Nodecimalplace
1:Onedecimalplace
2: Two decimal places
3: Three decimal places
4: Four decimal places
SH Maximumvalueof
PVinputscale -19999to30000,(SL<SH),|SH-SL|≤30000
SL Minimumvalueof
PVinputscale
Note1:SDP,SH,andSLaredisplayedonlyforvoltage/currentinput.
Note2:W:W-5%Re/W-26%Re(HoskinsMfg.Co.),ASTME988
Output Function
Parameter Symbol Name of Parameter Setting Range
OT
Outputtypeselection
Upper two digits
Lower two digits
ControloutputorHeating-
sidecontroloutput(Lower
twodigits)
00:OFF
01:
OUTterminals(voltagepulse)
02:OUTterminals(current)
03:OUTterminals(relay)
04:
OUT2terminals(voltagepulse)
05:OUT2terminals(current)
06:OUT2terminals(relay)
07:
RETterminals(voltagepulse)
08:RETterminals(current)
09:AL3terminals(relay)
10:AL2terminals(relay)
Cooling-sidecontroloutput
(Uppertwodigits)
00:OFF
01:
OUTterminals(voltagepulse)
02:OUTterminals(current)
03:OUTterminals(relay)
04:
OUT2terminals(voltagepulse)
05:OUT2terminals(current)
06:OUT2terminals(relay)
07:
RETterminals(voltagepulse)
08:RETterminals(current)
09:AL3terminals(relay)
10:AL2terminals(relay)
CT
Controloutputcycle
time
Heating-sidecontrol
output cycle time
(inHeating/cooling
control)
0.5to1000.0s
CTc
Cooling-sidecontrol
output cycle time
4.
AdjustingValvePositionAutomatically
(for a Position Proportional Type Controller Only)
Thefollowingoperatingproceduredescribeshowtoinputfeedbacksignalsfromthe
controlvalveandadjustthefully-openandfully-closedpositionsofthecontrolvalve
automatically.Thefully-openandfully-closedpositionsofthevalvecanbeadjusted
automaticallybyinputtingfeedbacksignalsfromthevalve.Toadjustthevalveposi-
tion,youneedtocarryouttheconnectionandbringthecontrollerintomanualmode.
Fortheconnection,see“6.TerminalWiringDiagrams”in"InstallationandWiring",
andforthemanualmode,see“5.SwitchingbetweenAUTOandMAN”in"Opera-
tions."
CTL menu is displayed.
Press the Right arrow key until OUT menu appears.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the Up arrow key.
Hold down the keys for 3 seconds.
+
Show the Operation Display.
OUT menu is displayed.
OFF blinks.
Press the SET/ENTER key.
1.
2.
3.
4.
5.
6.
7.
MAN
is lit
* When a password is set, PASS is displayed.
If the correct password is not entered, setup
parameters cannot be changed.
The parameter V.AT (automatic valve
position adjustment) is displayed.
ON is displayed.
Blinks during the change.
●When the adjustment is completed normally, the indication
automatically returns to OFF.
● When VAT.E appears on PV display, it indicates an error.
Check the wiring for feedback input and perform the
automatic adjustment again. To perform a valve adjustment
manually, see User’s Manual.
ON has been registered and the automatic
adjustment of the valve position starts.
V.AT blinks during the automatic adjustment.
After the adjustment is completed, press
the DISPLAY key once to return to the
Operation Display.
5. Setting Alarm Type
Thefollowingoperatingprocedureshowsanexampleofchangingthealarm-1type
(factorydefault:PVhighlimitalarm)toPVlowlimitalarm(setpoint:02).
MODE menu is displayed.
Press the Right arrow key until ALRM menu appears.
Press the SET/ENTER key.
Press the SET/ENTER key.
Hold down the key for 3 seconds.
Show the Operation Display.
ALRM menu is displayed.
1.
2.
3.
4.
The parameter AL1 (alarm-1 type) is
displayed.
Press the SET/ENTER key.
5.
6.
Energized/De-energized
Latch action
Stand-by action
The alarm-1 type setpoint 02 (PV low limit)
is registered.
After the setup is completed, press the DISPLAY key
once to return to the Operation Display.
Symbol
● To change the alarm type, change the last 2 digits of the
5-digit value.
● Stand-by action and excitation are turned on or off by
selecting 1 or 0. (See “ Setting Display of Alarm Type.”)
● For the latch action, see User ’s Manual.
The last digit of the setpoint blinks.
Change the setpoint using the Up/Down arrow keys
to increase and decrease the value and
the Left/Right arrow keys to move between digits.
Hysteresis
Alarm setpoint PV, PV2, AIN2
or AIN4
SP or Target SP
Hysteresis
PV Deviation setpoint
SP or Target SP
Deviation
setpoint
PV
Hysteresis Hysteresis
Open
(unlit)
Closed
(lit)
SP or Target SP
PV
Deviation setpoint
Hysteresis
- -
SP or Target SP
PV
Hysteresis Hysteresis
Deviation
setpoint
Open
(unlit)
SP or
Target SP
Alarm setpoint
Hysteresis
SP or
Target SP
Hysteresis
Alarm setpoint
Alarm setpoint
Output
Hysteresis
Closed
(lit)
Hysteresis
Alarm setpoint
Output
Alarm setpoint
Hysteresis
PV, PV2, AIN2
or AIN4
Hysteresis
Alarm setpoint PV, PV2, AIN2
or AIN4
SP or Target SP
Hysteresis
PV Deviation setpoint
SP or Target SP
Deviation
setpoint
PV
Hysteresis Hysteresis
SP or Target SP
PV
Deviation setpoint
Hysteresis
SP or Target SP
PV
Hysteresis Hysteresis
Deviation
setpoint
Closed
(unlit)
SP or
Target SP
Alarm setpoint
Hysteresis
SP or
Target SP
Hysteresis
Alarm setpoint
Alarm setpoint
Hysteresis
PV, PV2, AIN2
or AIN4
Alarm setpoint
Output
Hysteresis
Hysteresis
Alarm setpoint
Output
Setting Display of Alarm Type Stand-by Action
Energized (0) / De-energized (1)
Alarm type
Without (0) or With (1)
Stand-by action
Latch action (0/1/2/3/4)
See User’s Manual.
PV low limit
alarm setpoint
Treated
as normal
ºC
Power-on Time
The alarm output does not turn on
in this region even if the PV valule
is below PV low limit alarm setpoint.
Normal Abnormal
The alarm output
turns on.
No alarm (00)
Alarm Action (De-energized)
PV high limit (01)
Analog input PV high limit (19)
Analog input high limit (21)
Analog input AIN2 high limit (23)
Analog input AIN4 high limit (25)
PV low limit (02)
Analog input PV low limit (20)
Analog input PV2 low limit (22)
Analog input AIN2 low limit (24)
Analog input AIN4 low limit (26)
SP high limit (03)
Target SP high limit (09)
SP low limit (04)
Target SP low limit (10)
Deviation high limit (05)
Target SP deviation high
limit (11)
Deviation(%) high limit (32)
Target SP deviation(%) high
limit (36)
Deviation low limit (06)
Target SP deviation low limit (12)
Deviation(%) low limit (33)
Target SP deviation(%) low
limit (37)
Deviation high and low limits (07)
Target SP deviation high and
low limits (13)
Deviation(%) high and low
limits (34)
Target SP deviation(%) high and
low limits (38)
Deviation within high and low limits (08)
Target SP deviation within high
and low limits (14)
Deviation(%) within high and
low limits (35)
Target SP deviation(%) within high
and low limits (39)
Control output high limit (15)
Cooling-side control output
high limit (17)
Control output low limit (16)
Cooling-side control output
low limit (18)
Feedback input high limit (27)
Feedback input low limit (28)
PV velocity (29)
Fault diagnosis alarm (30)
FAIL (31)
Alarm Type (Alarm Setpoint) Alarm Action (Energized)
Open
(unlit)
Open
(unlit)
Open
(lit)
Closed
(lit) Open
(unlit)Open
(lit)Closed
(unlit)
Closed
(
unlit
)
Open
(lit)
Closed
(unlit) Closed
(unlit)
Open
(lit)
Open
(lit)
Closed
(lit) Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(lit)
Open
(lit)
Open
(lit)
Open
(lit)
Open
(lit)
Open
(lit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Burnout of PV input, PV2 input, or AIN2/AIN4 auxiliary
analog input. ADC failure, RJC error.
For the factory default, the contact output is turned ON in normal operation,
OFF at the time of FAIL. Control output: OFF or 0%, Alarm output: OFF
Note 1: “Open/closed” shows status of relay contact, and “lit/unlit” shows status of EV (event) lamp.
Note 2: Positive setpoint, Negative setpoint
Hysteresis
Alarm setpoint PV, PV2, AIN2
or AIN4
SP or Target SP
Hysteresis
PV Deviation setpoint
SP or Target SP
Deviation
setpoint
PV
Hysteresis Hysteresis
Open
(unlit)
Closed
(lit)
SP or Target SP
PV
Deviation setpoint
Hysteresis
- -
SP or Target SP
PV
Hysteresis Hysteresis
Deviation
setpoint
Open
(unlit)
SP or
Target SP
Alarm setpoint
Hysteresis
SP or
Target SP
Hysteresis
Alarm setpoint
Alarm setpoint
Output
Hysteresis
Closed
(lit)
Hysteresis
Alarm setpoint
Output
Alarm setpoint
Hysteresis
PV, PV2, AIN2
or AIN4
Hysteresis
Alarm setpoint PV, PV2, AIN2
or AIN4
SP or Target SP
Hysteresis
PV Deviation setpoint
SP or Target SP
Deviation
setpoint
PV
Hysteresis Hysteresis
SP or Target SP
PV
Deviation setpoint
Hysteresis
SP or Target SP
PV
Hysteresis Hysteresis
Deviation
setpoint
Closed
(unlit)
SP or
Target SP
Alarm setpoint
Hysteresis
SP or
Target SP
Hysteresis
Alarm setpoint
Alarm setpoint
Hysteresis
PV, PV2, AIN2
or AIN4
Alarm setpoint
Output
Hysteresis
Hysteresis
Alarm setpoint
Output
Setting Display of Alarm Type
Stand-by Action
Energized (0) / De-energized (1)
Alarm type
Without (0) or With (1)
Stand-by action
Latch action (0/1/2/3/4)
See User’s Manual.
PV low limit
alarm setpoint
Treated
as normal
ºC
Power-on
Time
The alarm output does not turn on
in this region even if the PV valule
is below PV low limit alarm setpoint.
Normal Abnormal
The alarm output
turns on.
No alarm (00)
Alarm Action (De-energized)
PV high limit (01)
Analog input PV high limit (19)
Analog input high limit (21)
Analog input AIN2 high limit (23)
Analog input AIN4 high limit (25)
PV low limit (02)
Analog input PV low limit (20)
Analog input PV2 low limit (22)
Analog input AIN2 low limit (24)
Analog input AIN4 low limit (26)
SP high limit (03)
Target SP high limit (09)
SP low limit (04)
Target SP low limit (10)
Deviation high limit (05)
Target SP deviation high
limit (11)
Deviation(%) high limit (32)
Target SP deviation(%) high
limit (36)
Deviation low limit (06)
Target SP deviation low limit (12)
Deviation(%) low limit (33)
Target SP deviation(%) low
limit (37)
Deviation high and low limits (07)
Target SP deviation high and
low limits (13)
Deviation(%) high and low
limits (34)
Target SP deviation(%) high and
low limits (38)
Deviation within high and low limits (08)
Target SP deviation within high
and low limits (14)
Deviation(%) within high and
low limits (35)
Target SP deviation(%) within high
and low limits (39)
Control output high limit (15)
Cooling-side control output
high limit (17)
Control output low limit (16)
Cooling-side control output
low limit (18)
Feedback input high limit (27)
Feedback input low limit (28)
PV velocity (29)
Fault diagnosis alarm (30)
FAIL (31)
Alarm Type (Alarm Setpoint) Alarm Action (Energized)
Open
(unlit)
Open
(unlit)
Open
(lit)
Closed
(lit) Open
(unlit)Open
(lit)Closed
(unlit)
Closed
(
unlit
)
Open
(lit)
Closed
(unlit) Closed
(unlit)
Open
(lit)
Open
(lit)
Closed
(lit) Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Closed
(lit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(unlit)
Open
(lit)
Open
(lit)
Open
(lit)
Open
(lit)
Open
(lit)
Open
(lit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Closed
(unlit)
Burnout of PV input, PV2 input, or AIN2/AIN4 auxiliary
analog input. ADC failure, RJC error.
For the factory default, the contact output is turned ON in normal operation,
OFF at the time of FAIL. Control output: OFF or 0%, Alarm output: OFF
Note 1: “Open/closed” shows status of relay contact, and “lit/unlit” shows status of EV (event) lamp.
Note 2: Positive setpoint, Negative setpoint
6. Setting Alarm Setpoint
Thefollowingoperatingprocedureshowsanexampleofsettingthealarm-1setpoint
ofgroup1to180.0.
Beforesettingthealarmsetpoint,checkthealarmtype.
Tochangethealarmtype,see“5.SettingAlarmType.”
Press the Right arrow key.
Press the SET/ENTER key.
SP menu is displayed.
Display the parameter and group
that need to be changed.
Blinks during the change.
The setpoint has been registered.
After the setup is completed, press
the DISPLAY key once to return to
the Operation Display.
Press the SET/ENTER key.
Press the Down arrow key until A1 appears.
Press the SET/ENTER key.
Press the SET/ENTER key.
Show the Operation Display.
Display MODE menu with the same procedure as described in
Setting Alarm Type.
1.
2.
3.
5.
4.
6.
7.
Group
The parameter A1 is displayed.
A1 to A8 represent the alarm-1 to -8 setpoints.
Each parameter and group can be changed
in the Parameter Setting Displays of alarms
using arrow keys.
Up/Down arrow keys: parameters
Left/Right arrow keys: groups
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and
the Left/Right arrow keys to move between digits.
Initializing parameter values
Parametersthatyouhavechangedcanbeinitializedtofactorydefaultvaluesoruser
defaultvalues.Fordetails,see“ParameterInitialization”intheUser’sManual.
Changing the parameter display levels
Thisoperationguidedoesnotexplainalltheparameters.Todisplayalltheparam-
eters,youneedtochangetheparameterdisplayleveltoprofessionalsettingmode.
Fordetails,see“SettingSecurityFunctions”intheUser’sManual.

IM 05P01B41-11EN page 7/14
7. Overview of Program Patterns
Theprogrammingexamplegivenheredemonstrateshowtodo the tasks outlined
below.
1) Program the controller to start program operation at 50.0°C and raise the
temperature up to 100.0°C in 50 minutes.
2) When the temperature reaches 100.0°C, keep it at this level for 30 minutes.
3) Raise the temperature up to 200.0°C in 60 minutes.
4) When the temperature reaches 200.0°C, keep it at this level for 30 minutes.
5) Lower the temperature to 50.0°C in 50 minutes.
6) When the temperature reaches 50.0°C, keep it at this level for 30 minutes.
PVinputrangesarefollowing:
MaximumvalueofPVinputrange:250.0°C
MinimumvalueofPVinputrange:0.0°C
PVinputunit:C
Program pattern action type (PGTY): 1, 2, or 3
ZonePIDselection(ZON):SegmentPIDselection(0)
SPramp-rateunit(TMU):HOUR
Seg.1 Seg.2 Seg.3 Seg.4 Seg.5 Seg.6
321
Segment time
TIME
Segment PID number
S.PIDN
100.0ºC
50.0ºC
200.0ºC
4 5 6
60 min.30 min.50 min. 30 min. 50 min. 30 min.
Time
Setpoint
TSP
TSP
TSP
The display symbols of the parameters, TSP (Final target setpoint), TIME (Segment
time setting), and S.PID (Segmet PID number selection) are the same in each
segment. However, the segment can be recognized by the number displayed on the
Symbol display.
TSP
SSP
TSP
SeeUser'sManualfortheWaitandRepeatactions,Zone PID, Start of program
operation(Startcode),Changingoperationmodeatsegment switching (Junction
code),Localmode,andRemotemode.
8. Creating Program Patterns
Thefollowingoperatingproceduredescribesan example of creatingtheprogram
discussedin“7.OverviewofProgramPatterns.”
CAUTION
BesuretocheckthePVinputrange,Spramp-rateunit(TMU)before
creating.
Set the common parameter of the specified pattern.
Starting target setpoint=50.0°C
STC=SSP (Starting target setpoint)
Segment 1
Set the final target setpoint.
Final target setpoint=100.0°C
Set the segment time.
Keep the initial value.
Hold down the keys for 3 seconds.
Show the Operation Display.
MODE menu is displayed.
PROG menu is displayed.
Press the Right arrow key.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the SET/ENTER key. (Blinks during the change.)
Press the SET/ENTER key. (Blinks during the change.)
Press the SET/ENTER key. (Blinks during the change.)
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and the
Left/Right arrow keys to move between digits.
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and the
Left/Right arrow keys to move between digits.
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and the
Left/Right arrow keys to move between digits.
Press the Down arrow key.
Set the segment PID number.
Keep the initial value.
Segment time=50 minutes
Press the SET/ENTER key.
Press the Down arrow key.
● Settings for the segment 2 to 6 can be done similarly.
● For programming and the settings for Wait and Repeat actions,
see User's Manual.
Press the DISPLAY key once to return to the
Operation Display.
Press the Down arrow key.
Press the Up/Down arrow key.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Press the Down arrow key (until TSP appears.)
12.
Set the junction code.
Keep the initial value.
Set the common parameter of the specified pattern.
Starting target setpoint=50.0°C
STC=SSP (Starting target setpoint)
Segment 1
Set the final target setpoint.
Final target setpoint=100.0°C
Set the segment time.
Keep the initial value.
Hold down the keys for 3 seconds.
Show the Operation Display.
MODE menu is displayed.
PROG menu is displayed.
Press the Right arrow key.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the SET/ENTER key. (Blinks during the change.)
Press the SET/ENTER key. (Blinks during the change.)
Press the SET/ENTER key. (Blinks during the change.)
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and the
Left/Right arrow keys to move between digits.
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and the
Left/Right arrow keys to move between digits.
Change the setpoint using the Up/Down arrow
keys to increase and decrease the value and the
Left/Right arrow keys to move between digits.
Press the Down arrow key.
Set the segment PID number.
Keep the initial value.
Segment time=50 minutes
Press the SET/ENTER key.
Press the Down arrow key.
● Settings for the segment 2 to 6 can be done similarly.
● For programming and the settings for Wait and Repeat actions,
see User's Manual.
Press the DISPLAY key once to return to the
Operation Display.
Press the Down arrow key.
Press the Up/Down arrow key.
1.
2.
3.
4.
5.
6.
7
.
8
.
9
.
10
.
11
.
Press the Down arrow key (until TSP appears.)
12
.
Set the junction code.
Keep the initial value.
9. Program Pattern Setup Charts
System name
ProgramNo.
Programname
Model
SerialNo.
Thefollowingparametersarenecessarytobesetbeforeprogramming.
Forthesettingrange,see"Parameters."
< Setup Parameters >
Parametersymbol Parameter name Usersettings
TMU SPramp-rateunit
ZON ZonePIDselection
PGTY Programpatternactiontype
Thefollowingparametersarecommonparametersfortheprogrampatternspecied.
Forthesettingrange,see"Parameters."
< Program Pattern Data (common parameter) >
Parametersymbol Parameter name Usersettings
STC Start code
SSP Startingtargetsetpoint
SSP Startingtargetsetpoint(forprogrampattern-2retransmission)
JC Junction code
WT.SW WaitfunctionON/OFF
WZ.UP Upper-sidewaitzone
WZ.LO Lower-sidewaitzone
R.CYCL Numberofrepeatcycles
<ProgramPatternData(parametersforsegments)>
MaximumvalueofPVinputrange/Maximumvalueof
PVinputscale
( )
Unit
Aprogrampatterncanbedrawnintherighttable.
MinimumvalueofPVinputrange/Minimumvalue
ofPVinputscale
( )
Parameter
symbol Parameter name Segments
1234567 8 9 10 11 12 13 14 15 16 17 18 19 20
TSP Finaltargetsetpoint
TSP
Final target setpoint
(forprogrampattern-2
retransmission)
TIME Segmenttimesetting
S.PID SegmentPIDnumberselection

IM 05P01B41-11EN page 8/14
Intentionallyblank Intentionallyblank

IM 05P01B41-11EN page 9/14
Contents
1. Monitoring-purposeOperationDisplaysAvailableduringOperation
2. SettingTargetSetpoint(SP)
3. Performing/CancelingAuto-tuning
4. SelectingTargetSetpointNumbers(SPNO.)
5. SwitchingbetweenAUTOandMAN
6. SwitchingbetweenRUNandSTOP
7. SwitchingbetweenREM(Remote)andLCL(Local)
8. SwitchingbetweenP.RUN(Startprogram)andP.STOP(Stopprogram)
9. Enabling/DisablingHold-mode(HOLD)ofProgramOperation
10.Executing“Advance”(ADV)Function
11.ManipulatingControlOutputinManualMode
12.Troubleshooting
1. Monitoring-purpose Operation Displays Available during Operation
■
Operation Display Switching Diagram for Standard and Posi-
tion Proportional Types
• SP Display
DisplaysthemeasuredinputvalueonPVdisplay.
Displaysthetargetsetpoint(SP)onSetpointdisplay(SPcanbechanged).
• OUT Display
DisplaysthemeasuredinputvalueonPVdisplay.
Displaysthecontroloutputvalue(OUT)onSetpointdisplay(OUTcanbechanged
inmanualmode).
Displaysthevalve’sfeedbackinputvalue(at0to100%valveopening)inPosition
proportional control.
SP Display
(SP can be changed.)
OUT Display
(OUT can be changed.)
Standard, Position Proportional, and Heating/Cooling Types
• SELECTDisplays1to5(whichappearwhenregistered)
• AnalogInputDisplay(displayonly)(factorydefault:non-display)
• PositionProportionalComputationOutput Display (displayonly)(factorydefault:
non-display)
• PIDNumberDisplay(displayonly)(factorydefault:non-display)
■
Operation Display Switching Diagram for Heating/Cooling Control
• SP Display
DisplaysthemeasuredinputvalueonPVdisplay.
Displaysthetargetsetpoint(SP)onSetpointdisplay(SPcanbechanged).
• OUT Display
DisplaysthemeasuredinputvalueonPVdisplay.
Displaysthecontroloutputvalues(C.H.)ofheatingandcoolingsidesonSetpoint
display(C.H.canbechangedinmanualmode).
SP Display
(SP can be changed.)
Heating/cooling OUT Display
(OUT can be changed.)
AftershowingtheOUTDisplay, press the DISPLAYkeytoshowthe following dis-
plays conditionally. Fordetails,seeUser’sManual.
2. Setting Target Setpoint (SP)
When the required value is displayed,
press the SET/ENTER key to register
the setpoint.
Show the SP Display (Operation Display).
(This is an example of setting the target
setpoint to 150.0).
Press the SET/ENTER key to start the
last digit of the setpoint blinking.
Blinking allows you to change the value.
To set the setpoint, use the
Left/Right arrow keys to move
between digits and the Up/Down
arrow keys to increase and
decrease the value.
1.
2.
3.
4.
3. Performing/Canceling Auto-tuning
Auto-tuningshouldbeperformedaftersettingatargetsetpoint.
Makesurethatthecontrollerisinautomaticmode(AUTO)andinrunmode(RUN)
beforeauto-tuning.ForsettingtoAUTO,see“5.SwitchingbetweenAUTOand
MAN,”andforsettingtoRUN,see“6.SwitchingbetweenRUNandSTOP.”
Ifthesetpointisknowninadvanceorauto-tuningdoesnotndanyappropriatePID
constants,setthePIDmanually.ForsettingthePIDmanually,seeUser’sManual.
CAUTION
Do not perform auto-tuning for the following processes.
Tune PID manually.
• Processes with fast response such as flow rate control and pres-
sure control.
• Processes which do not allow the output to be turned on and off
even temporarily.
• Processes which prohibit severe output changes at control
valves (or other actuators).
• Processes in which product quality can be adversely affected if
PVvaluesfluctuatebeyondtheirallowableranges.
Show the Operation Display.
Hold down the PARAMETER key for 3 seconds
to display MODE menu.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the Down arrow key until the parameter AT appears.
The parameter AT (auto-tuning switch) is displayed.
1.
2.
3.
4.
The parameter R.L (REMOTE/LOCAL switch)
is displayed.
OFF blinks.
Press the Up/Down arrow keys to display the required setpoint.
Blinks during the change.
The setpoint has been registered.
This starts auto-tuning.
The limiter can be set to the output during auto-tuning.
For details, see User’s Manual.
The MAN lamp goes off, which means that
the auto-tuning completed normally.
5.
6.
7.
8.
The setting range is 1 to 16 (represent group numbers) or R.
To perform auto-tuning for the PID of group 1, set the parameter AT to 1.
To quit the auto-tuning, set the parameter to OFF.
During auto-tuning,
• The MAN lamp blinks.
• The OUT symbol appears.
• The output values at 100.0% and
0% appear alternately.
Press the SET/ENTER key.
4. Selecting Target Setpoint Numbers (SPNO.)
Thefollowingoperatingprocedureshowsanexampleofchangingthetargetsetpoint
number(SPNO.)from1to2.EachSPhasitsPIDgroup.ThePIDgroupsetforthe
parameterPIDN(PIDnumberselection)isused.
Show the Operation Display.
Hold down the PARAMETER key for 3 seconds
to display MODE menu.
Press the SET/ENTER key.
SPNO. has been changed to 2.
Blinks during the change.
The setpoint has been registered.
Press the DISPLAY key once to return to
the Operation Display.
Change the setpoint using
the Up/Down arrow keys.
Press the Down arrow key until the parameter SPNO.
appears.
Press the SET/ENTER key.
Press the SET/ENTER key.
1.
2.
3.
4.
5.
6.
7.
The parameter R.L (REMOTE/LOCAL switch) is
displayed.
The parameter SPNO. (SP number selection)
is displayed.
Operation
Guide
UT75A
Digital Indicating Controller
Operation Guide for Single-loop Control
This operation guide describes key entries for operating the UT75A.
For operations using external contact inputs, see “DI” of “6. Terminal Wiring Diagrams”
in “Installation and Wiring.”
If you cannot remember how to carry out an operation during setting, press the
DISPLAY key once. This brings you to the display (Operation Display) that appears at
power-on.
The scrolling guide is displayed on PV display in the Parameter Setting Display.
This guide can be turned on/off with the Fn key.
Operations
For details of the each function, refer to the electronic manual. User
's manuals can be
downloaded or viewed at the following URL.
Functional
Enhancement
http://www.yokogawa.com/ns/ut/im/
Show the Operation Display.
Hold down the PARAMETER key for 3 seconds
to display MODE menu.
Press the SET/ENTER key.
SPNO. has been changed to 2.
Blinks during the change.
The setpoint has been registered.
Press the DISPLAY key once to return to
the Operation Display.
Change the setpoint using
the Up/Down arrow keys.
Press the Down arrow key until the parameter SPNO.
appears.
Press the SET/ENTER key.
Press the SET/ENTER key.
1.
2.
3.
4.
5.
6.
7.
The parameter R.L (REMOTE/LOCAL switch) is
displayed.
The parameter SPNO. (SP number selection)
is displayed.
5. Switching between AUTO and MAN
AUTOandMANswitchingcanbeperformedusinganyofthefollowing:(1)A/Mkey,
(2)Contactinput,(3)Communication,and(4)Userfunctionkey.
ThegurebelowshowsadirectoperationusingtheA/Mkey.
WhenAUTOand MAN switchingfunctionisassignedtothecontactinput,andthe
contactinputisON,theswitchingbykeyoperationcannotbeperformed.
Fordetails,seeUser’sManual.
MAN lamp is lit in MAN mode.
Each time you press the key,
AUTO and MAN is switched alternately.
WhenAUTOisswitchedintoMAN,thecontroloutputvalueinAUTOmodeisheld.
Thecontrollercanbeoperatedmanuallyfromtheholdvalue.
Ifthemanualpresetoutputisset(MPONparameter≠OFF),thecontrollercan be
operatedmanuallyfromthearbitraryoutputvalue(MPO1toMPO5parameters).
6. Switching between RUN and STOP
RUNandSTOPswitchingcanbeperformedusinganyofthefollowing:(1)Contact
input,(2)Parameter,(3)Communication,and(4)Userfunctionkey.
Thefollowingshowsanexampleofswitchingusingthecontactinput.
(TheswitchingfunctionisassignedtoDI2contactforthefactorydefault.)
Fordetailsofotherswitchingmethodsandthedisplayappearingwhentheoperation
isstarted,seeUser’sManual.
Whenthecontrollerisstopped,inputandoutputsareasfollows:
PVinput DisplaysthePVvalue.
Controloutput Displaysthepresetoutputvalue.
ThepresetoutputvalueissetforeachPIDgroup.
Alarmoutput Turns the output on in case of an alarm.

IM 05P01B41-11EN page 10/14
Display in STOP mode
“STOP”is displayed on Symbol display and "preset output value" is displayedon
Datadisplay.
OFF: Operation RUN
Display in STOP mode
210
212
ON: Operation STOP
210
212
Preset output (PO)
Valve opening (0-100%) for
Position proportional type
STOP lamp is lit.
DI2
DI2
Display in STOP mode in Heating/cooling control
“Cooling-sidepresetoutputvalue”isdisplayedontheleftsideofthe“ST”symbol,
and“Heating-sidepresetoutputvalue”isontherightside.
OFF: Operation RUN
Display in STOP mode
210
212
ON: Operation STOP
210
212
Heating-side preset output (PO)
STOP lamp is lit
Cooling-side preset output (POc)
.
DI2
DI2
7. Switching between REM (Remote) and LCL (Local)
Remoteandlocalswitchingcanbeperformedusinganyofthefollowing:
(1)Contactinput,(2)Parameter,(3)Communication,and(4)Userfunctionkey.
LCL (Local)
Controlisperformedusingthetargetsetpointsetonthecontroller.
REM (Remote)
Controlisperformedusinganexternalanalogsignalthatisusedasthetargetset-
point.The following showsanexampleofswitchingfromlocaltoremoteusingthe
parameter.
Fordetailsofotherswitchingmethods,seeUser’sManual.
•ThePIDgroupforthelocalSPnumberisusedasPIDinremotemode.
NOTE
WhenthecontactinputisON,operationcannotbeperformedusingtheparameter,
communication,orkey.WhenthecontactinputisOFFandthesettingis switched
usingtheparameter,communication,orkey,thelastswitchingoperationisper-
formed.
Show the Operation Display.
Hold down the PARAMETER key for 3 seconds
to display MODE menu.
Press the SET/ENTER key.
1.
2.
Press the SET/ENTER key.
The REM lamp is lit.
Change the operation mode using
the Up/Down arrow keys.
Blinks during the change.
Press the SET/ENTER key.
3.
4.
5.
The parameter R.L (REMOTE/LOCAL switch)
is displayed.
Show the Operation Display.
Hold down the PARAMETER key for 3 seconds
to display MODE menu.
Press the SET/ENTER key.
1.
2.
Press the SET/ENTER key.
The REM lamp is lit.
Change the operation mode using
the Up/Down arrow keys.
Blinks during the change.
Press the SET/ENTER key.
3.
4.
5.
The parameter R.L (REMOTE/LOCAL switch)
is displayed.
8.
Switching between P.RUN (Start program) and P.STOP (Stop program
)
Programstart/stopswitchingcanbeperformedusinganyofthefollowing:(1)Con-
tactinput,(2)Parameter,and(3)Communication.
Settingtheprogrampatternactiontype(PGTY)to1,2,or3enablestheprogram
start/stopswitching.
Show the Operation Display.
Hold down the PARAMETER key for 3 seconds
to display MODE menu.
Press the SET/ENTER key.
1.
2.
Press the SET/ENTER key.
Change the operation mode using
the Up/Down arrow keys.
Blinks during the change.
Press the SET/ENTER key.
3.
4.
5.
The parameter PROG (RUN/STOP switch of
program operation) is displayed.
The PRG lamp is lit.
9.
Enabling/Disabling Hold Mode of Program Operation
Enabling/disablingholdmodeofprogramoperationcanbeperformedduringpro-
gramoperationusinganyofthefollowing:(1)Parameter,(2)Contactinput,(3)Com-
munication,and(4)Userfunctionkey.
Thefollowingshowsanexampleofswitchingusingtheparameter.
Show the Operation Display.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the SET/ENTER key.
The parameter HOLD (Pause/cancel release
of program operation) is displayed (during
program operation.)
1.
2.
3.
4.
5.
Hold down the PARAMETER key for
3 seconds to display MODE menu.
Blinks during the change.
Change the setpoint using
the Up/Down arrow keys.
The PRG lamp blinks.
10. Executing “Advance” Function
“Advance”canbeperformedduringprogramoperationusinganyofthefollowing:(1)
Parameter,(2)Contactinput,(3)Communication,and(4)Userfunctionkey.
Thefollowingshowsanexampleofswitchingusingtheparameter.
Whenexecutingthe“Advance”functionduringhold-modeoperation,theholdmode
isdisabled.
1.
2.
3.
4.
5.
Show the Operation Display.
Press the SET/ENTER key.
Press the SET/ENTER key.
Press the SET/ENTER key.
The parameter ADV (Advance of segment) is
displayed (during program operation.)
Hold down the PARAMETER key for
3 seconds to display MODE menu.
Blinks during the change.
Change the setpoint using
the Up/Down arrow keys.
The PRG lamp is lit.
11. Manipulating Control Output in Manual Mode
NOTE
Inmanualmode,controloutputismanipulatedbyoperatingthekeys(thevalueis
changedusingtheUp/Downarrowkeys,thenoutputtedasitis).
EveniftheSET/ENTERkeyisnotpressed,thecontrol output value changesac-
cordingtothedisplayedvalue.
Instopmode(whentheSTOPlampislit),controloutputcannotbemanipulated.
MAN lamp is lit.
Up arrow key: increases control output.
Down arrow key: decreases control output.
In Position proportional control:
Up arrow key; opens the valve.
Down arrow key; closes the valve.
Output; only while pressing a key.
OUT; valve opening (0-100%)
Output manipulation in Position proportional control
is not restricted from output limiters (OH, OL).
Manual operation in Heating/cooling control
Symbol of cooling side
Target setpoint (SP) number
Symbol of heating side
Heating-side control output
Cooling-side control output
Uparrowkey:concurrentlydecreasescooling-sidecontroloutputandincreases
heating-sidecontroloutput.
Downarrowkey:concurrentlyincreasescooling-sidecontroloutput and decreases
heating-sidecontroloutput.
(Eithernoneoftheheating-sideandcooling-sideoutputsarepresented,orbothof
themarepresentedaccordingtothedeadbandsetting.)
Actual output (%)
DB=24.8
Dead band: Operation parameter DB
Control computation output Control computation output
12.40-12.4
Manipulated output change
when a dead band is positive (+)
Actual output (%)
100
DB= -24.8
12.40-12.4
Manipulated output change
when a dead band is negative (-)
100
Cooling-side
manipulated output
Heating-side
manipulated output
Heating-side
manipulated output
Cooling-side
manipulated output
12. Troubleshooting
■TroubleshootingFlow
IftheOperationDisplaydoesnotappearafterturningon the controller’spower,
checktheproceduresinthefollowingowchart.
Ifaproblemappearstobecomplicated,contactoursalesrepresentatives.
Is the controller
defective?
Contact us for repair.
Problem solved.
No communication
capability
Completely
inactive?
Yes
Yes
Yes
No
No
No
Key
operation
failure?
Yes
No
Yes
Check wiring of the
power terminals.
Check the key lock
setting.
Display
failure?
*
Yes
No
Turn off power, and
then turn it on again.
I/O signal
failure?
Yes
No
Check the
supply voltage.
Check the
specifications and polarity
of connected devices .
Check the communication-
related parameters.
Check the specifications
of communication
devices.
Check the
communication wiring.
Communication
failure?
No
With
communi-
cation?
Yes
Yes
Normal?
Is the
key locked?
Check the specifications
of the controller.
Yes
No Correct?
Correct the error(s).
Cancel the setting.
Check the I/O specifications
of the controller.
* The LCD (a liquid crystal display) is used for
a display portion of this product.
The LCD has a characteristic that the display action
becomes late at the low temperature.
Additionally, the luminance and contrast degradation
are caused due to aged deterioration.
However, the control function is not affected.
■
Remedies if Power Failure Occurs
during Operations
• Instantaneouspowerfailurewithin20ms.
Apowerfailureis notdetected.Normal
operation continues.
• Powerfailure for less than about 5 sec-
onds,orforabout5secondsormore.
Affectsthe "settings" and "operation
status."
Fordetails,seeUser'sManual.
NOTE
Writedownthesettingsofparametersfora
repairrequest.
■FortheErrorsatPowerOnand
the Errors during Operation, see
“Installation” in this manual.

IM 05P01B41-11EN page 11/14
Operation Parameters
HolddownthePARAMETERkeyfor3secondstomovefromtheOperationDisplayto
theOperationParameterSettingDisplay.PresstheDISPLAYkeyoncetoreturntothe
OperationDisplay.
Menu
Hold down PARAMETER key for 3 sec.
DISPLAY key
SET/ENTER key
PARAMETER key
key key key
key key
The parameter groups can be switched using , keys.
Operation Dsipaly
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
END
Menu
END
Menu END
END
Menu Display and
Parameter Setting
Display are changed
in a circular pattern.
Move to the Setup Parameter Setting Display:
Hold down the PARAMETER key and the Left arrow key simultaneously for 3 sec.
Operation for Setting
· Toselecttheparametersettingdisplayedastheinitialvalue,presstheDownarrow
keytomovetothenextparameter.
· Tochangeandsettheparametersetting,presstheSET/ENTERkeytostarttheset-
pointblinking.Theblinkingstateallowsyoutomakechanges(settingmode).Usethe
Up/Down/Left/Rightarrowkeystochangethesetpoint.PresstheSET/ENTERkeyto
registerthesetting.
Notethattherearesomeparameterswhich are not displayeddependingonthemodel
andsufxcodes,controlmode(CTLM),controltype(CNT),etc.Theparametersforpro-
fessionalsettingmode(LEVL:PRO)arenotdescribedinthismanual.SeeUser’sManual.
■Operation Mode
Menusymbol: (MODE)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(S.R) STOP/RUNswitch
STOP:Stopmode
RUN:Runmode
Presetoutput(PO)isgeneratedin
STOPmode.
Default:Notdisplayed.STOP/RUN
switchisassignedtocontactinput.
RUN
EASY
(R.L) REMOTE/LOCALswitch
LCL:Localmode
REM:Remotemode
Select a remote input method for
acquiringthetargetsetpointfrom
remoteinputorcommunicationusing
theparameterRMS.
LCL
(HOLD)
Pause/cancelreleaseof
programoperation
Displayduringprogramoperation.
ON:Pause
OFF:Cancelrelease(Programopera-
tionrestart)
OFF
(ADV) Advanceofsegment
Displayduringprogramoperation.
Setas“ADV=ON”toadvancefrom
thecurrentsegmenttothenextseg-
ment.
OFF
(PROG)
RUN/STOPswitchof
programoperation
ParameterPROGisdisplayedwhen
PGTYissettootherthan0.
P.STOP:Stopofprogramoperation
P.RUN:Startofprogramoperation
P.STOP
(AT) AUTO-tuningswitch
OFF:Disable
1to16:Performauto-tuning.Tuning
resultisstoredinthespecied
numberedPID.
R:TuningresultisstoredinthePID
forreferencedeviation.
OFF
(SPNO.) SPnumberselection 1to20(Dependsonthesetupparam-
eterSPGR.setting.) 1
(PID) PIDnumber
ThePIDgroupnumberbeingselected
is displayed.
1to16,R:PIDgroupforreference
deviation
1
■SELECT Parameter
Menusymbol: (CS)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
Registered
parameter
symbol
SELECTparameter10
to19
Settingrangeofaregisteredparam-
eter.
Fordetails,seeUser'sManual.
—Table
below EASY
Parameter n=10 n=11 n=12 n=13 n=14 n=15 n=16 n=17 n=18 n=19
CSn
FortheregistrationofSELECTparameters,seeUser'sManual.
■Program Setting Parameter
Menusymbol:( PROG)
Parameter
symbol
Name of
Parameter Setting Range Initial
value
User
setting
Display
level
(STC) Start code
SSP:Programoperationbeginswiththestarting
targetsetpoint.
RAMP:Ramp-prioritizedPVstart
TIME:Time-prioritizedPVstart
SSP
EASY
(SSP)
Startingtarget
setpoint
0.0to100.0%ofPVinputrange(EU)(Setting
range:P.RLtoP.RH) P.RL
(JC) Junction code
CONT:Switchingforcontinuation
HOLD:Hold-onswitching(thecontrollerholdstheend-of-
segmentsetpointwhenthesegmentiscompleted,to
performcontrol).
CONT
(WT.SW)
Waitfunction
ON/OFF
OFF:Disable
ON:Enable OFF
(WZ.UP)
Upper-side
waitzone
0.0to10.0%ofPVinputrange(EU)
0.5%
ofPV
input
range
(WZ.LO1)
Lower-side
waitzone
0.5%
ofPV
input
range
(R.CYCL)
Numberof
repeat cycles
0to999,CONT(limitlessnumberof
times) 0
Whentheprogrampattern-2retransmissionisselected(PGTY=2),thesecondloopisalsodisplayedforthe
parameterSSP.(LP2lampislit.)
■Program Setting Parameter
(Thefollowingparametersaredisplayedtopresstheright/leftarrowkeyduringdisplayingabove
parameter.)
Menusymbol:( PROG)
Parameter
symbol
Name of
Parameter Setting Range Initial
value
User
setting
Display
level
(TSP)
Finaltarget
setpoint
0.0to100.0%ofPVinputrange(EU)(Setting
range:P.RLtoP.RH) P.RL
See
"Initial
Set-
tings"
in this
manual.
EASY
(TIME)
Segmenttime
setting
-:Unregistered
0.00to99.59(“hour.minute”or“minute.second”)
*UsetheparameterTMUtosetthetimeunit.
(Commonintheinstrument.)
*Ifthesettingis0.00,TSPchangesinstepwise
after one control period.
-
(S.PID)
SegmentPID
numberselection
1 to 16 1
Whentheprogrampattern-2retransmissionisselected(PGTY=2),thesecondloopisalsodisplayedforthe
parameterTSP.(LP2lampislit.)
■SP and Alarm Setpoint Setting Parameter
Menusymbol: (SP)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(SP.J) JumptoSPgroup
ThespeciedSPgroupisdisplayed.
1to 20(Dependson thesetuppa-
rameterSPGR.setting.)
1-
EASY
(SP) Targetsetpoint 0.0to100.0%ofPVinputrange(EU)
(Settingrange:SPLtoSPH) SPL
Table
below
(SUB)
Sub-targetsetpoint(in
Two-positiontwo-level
control)
Set the offset from SP.
-100.0to100.0%ofPVinputrange
span(EUS)
0.0%
ofPV
input
range
span
(PIDN) PIDnumberselection
SetaPIDgroupnumbertouse.
1to16(Dependsonthesetupparam-
eterPIDG.setting.)
1to8
to
(A1toA8)
Alarm-1to-8setpoint
SetadisplayvalueofsetpointofPV
alarm,SPalarm,deviationalarm,
outputalarm,orvelocityalarm.
-19999to30000(Setavaluewithinthe
inputrange.)
Decimalpointpositiondependsonthe
input type
0
(UPR) SPramp-uprate
UsedtopreventSPfromchanging
suddenly.
Setaramp-uprateorramp-downrate
per hour or minute. Set a time unit
usingtheparameterTMU.
OFF,0.0+1digitto100.0%ofPV
inputrangespan(EUS)
OFF
(DNR) SPramp-downrate OFF
FortheparameterSP(targetsetpoint),8groupsaredisplayedforthefactorydefault.
ThenumberofgroupscanbechangedbythesetupparameterSPGR.(numberofSP
groups).Forthealarmsetpointparameter,alarm-1to-4aredisplayedforthefactory
default.ThenumberofalarmscanbechangedusingthesetupparameterALNO.(num-
berofalarms).TochangethenumberofSPgroupsoralarms,seeUser'sManual.
UsethefollowingtabletorecordSPandalarmsetpoints.
Parameter n=1 n=2 n=3 n=4 n=5 n=6 n=7 n=8
SP
SUB
PIDN
A1
A2
A3
A4
A5
A6
A7
A8
UPR
DNR
n:groupnumber
■SP-related Setting Parameter
Menusymbol: (SPS)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(RMS) Remoteinputmethod RSP:Viaauxiliaryanaloginput
COM:Viacommunication RSP
STD
(RFL) Remoteinputlter OFF,1to120s OFF
(RT) Remoteinputratio
SP=RemoteinputxRT+Remote
inputbias
0.001to9.999
1.000
(RBS) Remoteinputbias -100.0to100.0%ofPVinputrange
span(EUS)
0.0%
ofPV
input
range
span
(TMU) SPramp-ratetimeunit
HOUR:Ramp-uprateorramp-down
rate per hour
MIN:Ramp-uprateorramp-down
rate per minute
SEC:Ramp-uprateorramp-down
rate per second
HOUR EASY
(SPT) SPtrackingselection
Trackingisperformedwhenthemode
changesfromRemotetoLocal.(The
local setpoint keeps track of the
remotesetpoint.)
OFF,ON
ON
STD
(PVT) PVtrackingselection
Causesthesetpointtokeeptrackofthe
PVsothesetpointautomaticallyreverts
toitsoriginalvalueatapresetrateof
change.TheUPR,DNR,andTMUare
usedincombination.
Operatingconditions:1)MAN→AUTO,
2)STOP→AUTO,3)Power-on,4)SP
numberchange,5)SPchange
OFF,ON
OFF
■Alarm Function Setting Parameter
Menusymbol: (ALRM)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
to
(AL1toAL8)
Alarm-1to8type
Example:Alarm-1
Stand-by
action
Latch action
Energized/
De-energize
Alarm
type
Seta5-digitvalueinthefollowingorder.
[Latchaction(0/1/2/3/4)]+[Energized
(0)orDe-energized(1)]+[Without(0)
orWith(1)Stand-byaction]+[Alarm
type:2digits(seebelow)]
Forlatchaction,seeUser'sManual.
AL1,
AL3:
Latch
action
(0)
Ener-
gized
(0)
Without
Stand-
by
action
(0)
PVhigh
limit(01)
AL2,
AL4:
Latch
action
(0)
Ener-
gized
(0)
Without
Stand-
by
action
(0)
PVlow
limit(02)
AL5to
AL8:not
displayed
for
factory
default
Table
below EASY
Alarmtype:2digits
00:Disable
01:PVhighlimit
02:PVlowlimit
03:SPhighlimit
04:SPlowlimit
05:Deviationhighlimit
06:Deviationlowlimit
07:Deviationhighandlowlimits
08:
Deviationwithinhighandlowlimits
09:TargetSPhighlimit
10:TargetSPlowlimit
11:TargetSPdeviationhighlimit
12:TargetSPdeviationlowlimit
13:
TargetSPdeviationhighandlowlimits
14:
TargetSPdeviationwithinhighandlowlimits
15:OUThighlimit
16:OUTlowlimit
17:Cooling-sideOUThighlimit
18:Cooling-sideOUTlowlimit
19:AnaloginputPVhighlimit
20:AnaloginputPVlowlimit
21:AnaloginputPV2highlimit
22:AnaloginputPV2lowlimit
23:AnaloginputAIN2highlimit
24:AnaloginputAIN2lowlimit
25:AnaloginputAIN4highlimit
26:AnaloginputAIN4lowlimit
27:Feedbackinputhighlimit
28:Feedbackinputlowlimit
29:PVvelocity
30:Faultdiagnosis
31:FAIL
32:Deviation(%)highlimit
33:Deviation(%)lowlimit
34:Deviation(%)highandlowlimits
35:
Deviation(%)withinhighandlowlimits
36:TargetSPdeviation(%)highlimit
37:TargetSPdeviation(%)lowlimit
38:
TargetSPdeviation(%)highandlowlimits
39:
TargetSPdeviation(%)withinhighandlowlimits
to
(VT1toVT8)
PVvelocityalarmtime
setpoint1to8 0.01to99.59(minute.second) 1.00 Table
below EASY
to
(HY1toHY8)
Alarm-1to-8hysteresis
Setadisplayvalueofsetpointofhysteresis.
-19999to30000(Setavaluewithinthe
inputrange.)
Decimalpointpositiondependsonthein-
puttype.Whenthedecimalpointposition
fortheinputtypeissetto"1",theinitial
valueofthehysteresisis"1.0".
10 Table
below EASY
to
(DYN1toDYN8)
Alarm-1to-8On-delay
timer
AnalarmoutputisONwhenthedelay
timerexpiresafterthealarmsetpoint
is reached.
0.00to99.59(minute.second)
0.00
Table
below STD
(AMD) Alarmmode
0:Alwaysactive
1:NotactiveinSTOPmode
2:NotactiveinSTOPorMANmode
0
Forthealarmfunctionsettingparameter,4alarmsaredisplayedforthefactorydefault.
ThenumberofalarmscanbechangedbythesetupparameterALNO.(numberof
alarms).Tochangethenumberofalarms,seeUser’sManual.
Parameter n=1 n=2 n=3 n=4 n=5 n=6 n=7 n=8
ALn
VTn
HYn
DYNn
n:alarmnumber
■PV-relatedSettingParameter
Menusymbol: (PVS)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(BS) PVinputbias -100.0to100.0%ofPVinputrange
span(EUS)
0.0%
ofPV
input
range
span EASY
(FL) PVinputlter OFF,1to120s OFF
■PID Setting Parameter
Menusymbol: (PID)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(PID.J) JumptoPIDgroup
ThespeciedPIDgroupisdisplayed.
1to 16(Dependson thesetuppa-
rameterPIDG.setting.)
1-
EASY
(P)
Proportionalband
Heating-sidepropor-
tionalband(inHeating/
coolingcontrol)
0.0to999.9%
When0.0%isset,itoperatesas
0.1%.
Heating-sideON/OFFcontrolapplies
when0.0%inHeating/coolingcontrol
5.0%
(I)
Integraltime
Heating-sideintegraltime
(inHeating/coolingcontrol)
OFF:Disable
1to6000s 240s
(D)
Derivativetime
Heating-sidederivativetime
(inHeating/coolingcontrol)
OFF:Disable
1to6000s 60s
(OH)
Controloutputhighlimit
Heating-sidecontrol
outputhighlimit(in
Heating/coolingcontrol)
-4.9to105.0%,(OL<OH)
InHeating/coolingcontrol:0.1to
105.0%(OL<OH)
100.0%
(OL)
Controloutputlowlimit
Heating-sidecontrolout-
putlowlimit(inHeating/
coolingcontrol)
-5.0to104.9%,(OL<OH),SD:Tight
shut
InHeating/coolingcontrol:0.0to
104.9%(OL<OH)
0.0%
(MR) Manual reset
EnabledwhenintegraltimeisOFF.
Themanualresetvalueequalsthe
outputvaluewhenPV=SP.
-5.0to105.0%
50.0%
(HYS)
Hysteresis(inON/
OFFcontrol,Position
proportionalcontrol,or
Two-positiontwo-level
control)
Heating-sideON/OFF
controlhysteresis(in
Heating/coolingcontrol)
InON/OFFcontrolorTwo-position
two-levelcontrol:0.0to100.0%of
PVinputrangespan(EUS)
InHeating/coolingcontrolorPosition
proportionalcontrol:0.0to100.0%
*1
(SU.HY)
Sub-hysteresis(in
Two-positiontwo-level
control)
0.0to100.0%ofPVinputrange
span(EUS)
0.5%
ofPV
input
range
span
EASY
(HY.UP)
Upper-sidehysteresis
(inON/OFFcontrol)
0.0to100.0%ofPVinputrange
span(EUS)
0.5%
ofPV
input
range
span
(HY.LO)
Lower-sidehysteresis
(inON/OFFcontrol)
(DR)
Direct/reverseaction
switch
RVS:Reverseaction
DIR:Directaction
RVS
STD
(SU.DR)
Sub-direct/reverse
actionswitch(inTwo-
positiontwo-level
control)
DIR
Operation
Guide
UT75A
Digital Indicating Controller
Operation Guide for Single-loop Control
Yokogawa Electric Corporation
Parameters
For details of the each function, refer to the electronic manual. User
's manuals can be
downloaded or viewed at the following URL.
Functional
Enhancement
This operation guide describes the functions of parameters briefly. The parameter
symbols listed are in the order shown on the display in each group of menu symbols.
In addition, each parameter table has a “User Setting” column, where you can record
your setpoints when setting them in the controller. The scrolling guide is displayed on PV
display in the Parameter Setting Display. This guide can be turned on/off with the Fn key.
http://www.yokogawa.com/ns/ut/im/
*1:InON/OFFcontrolorTwo-positiontwo-levelcontrol:0.5%ofPVinputrangespan
InHeating/coolingcontrolorPositionproportionalcontrol:0.5%

IM 05P01B41-11EN page 12/14
(Pc)
Cooling-sidepropor-
tionalband
0.0to999.9%
(Cooling-sideON/OFFcontrolap-
plieswhen0.0%inHeating/cooling
control)
5.0%
EASY
(Ic)
Cooling-sideintegral
time
OFF:Disable
1to6000s 240s
(Dc)
Cooling-sidederivative
time
OFF:Disable
1to6000s 60s
(OHc)
Cooling-sidecontrol
outputhighlimit 0.1to105.0%,(OLc<OHc) 100.0%
(OLc)
Cooling-sidecontrol
output low limit 0.0to104.9%,(OLc<OHc) 0.0%
(HYSc)
Cooling-sideON/OFF
control hysteresis 0.0to100.0% 0.5%
(DB)
Outputdeadband(in
Heating/coolingcontrol
or Position proportional
control)
InHeating/coolingcontrol:-100.0to
50.0%
InPositionproportionalcontrol:1.0
to10.0%
3.0%
(PO)
Preset output
Heating-sidepreset
output(inHeating/cool-
ingcontrol)
InSTOPmode,xedcontroloutput
canbegenerated.InPositionpropor-
tionalcontrol,Valveopeningcanbe
set;-5.0to105.0%
0.0%
(SU.PO)
Sub-presetoutput(in
Two-positiontwo-level
control)
InSTOPmode,xedsub-control
outputcanbegenerated.
0%,100%
0%
(POc)
Cooling-sidepreset
output
InSTOPmode,cooling-sidexed
controloutputcanbegenerated.
-5.0to105.0%
0.0%
ForthePIDsettingparameter,8groupsaredisplayedforthefactorydefault.
ThenumberofgroupscanbechangedbythesetupparameterPIDG.(numberofPID
groups).TochangethenumberofPIDgroups,seeUser'sManual.
IfyouareusingtwoormoregroupsofPIDparameters,usethefollowingtabletorecordtheirsettingvalues.
Parameter n=2 n=3 n=4 n=5 n=6 n=7 n=8 R
P
I
D
OH
OL
MR
HYS
SU.HY
HY.UP
HY.LO
DR
SU.DR
Pc
Ic
Dc
OHc
OLc
HYSc
DB
PO
SU.PO
POc
n:groupnumber
■Tuning Parameter
Menusymbol: (TUNE)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(SC) Super function
OFF:Disable
1:Overshootsuppressingfunction
(normalmode)
2:Huntingsuppressingfunction(stable
mode)
Enablestoanswerthewiderchar-
acteristicchangescomparedwith
response mode.
3:Huntingsuppressingfunction(re-
sponsemode)
Enablesquickfollow-upandshort
convergingtimeofPVforthe
changedSP.
4:Overshootsuppressingfunction(strong
suppressingmode)
Note:Setpoints2and3mustbeused
inPIDcontrolorPIcontrol.Disabled
inthefollowingcontrols:
1)ON/OFFcontrol,2)PDcontrol,3)
Pcontrol,4)Heating/coolingcontrol.
Donotusethefunctionforthecontrol
processes with response such as
oworpressurecontrol.
OFF EASY
(AT.TY)
Auto-tuningtype
0:Normal
1:Stability 0 STD
(STM) Sample PI sampled time 0to9999s 60s
EASY
(SWD)
Sample PI control time
span 0to9999s 30s
(AR)
Anti-resetwindup
(excessintegration
prevention)
AUTO,50.0to200.0% AUTO STD
(OPR.U)
Upper-sideoutputveloc-
ity limiter OFF:Disable
0.1to100.0%/s
OFF
STD
(OPR.D)
Lower-sideoutputveloc-
ity limiter OFF
(MPON)
Manual preset output
numberselection
SelecttheoutputusedinMANmode
whenswitchedfromAUTOtoMANmode.
OFF:HoldthecontroloutputinAUTO
mode(bumpless)
1:
Usemanualpresetoutput1(outputbump)
2:
Usemanualpresetoutput2(outputbump)
3:
Usemanualpresetoutput3(outputbump)
4:
Usemanualpresetoutput4(outputbump)
5:
Usemanualpresetoutput5(outputbump)
OFF
to
(MPO1toMPO5)
Manual preset output 1
to 5
-5.0to105.0%
However,outputislimitedtothe
outputhighlimitandlowlimit.
0.0% Table
below
Usethefollowingtabletorecordthemanualpresetoutputsettingvalue.
Parameter n=1 n=2 n=3 n=4 n=5
MPOn
■Zone Control Parameter
Menusymbol: (ZONE)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
to
(RP1toRP7)
Referencepoint1to7
Set reference points at which switch-
ingiscarriedoutbetweengroupsof
PIDconstantsaccordingtothegiven
temperaturezone.
0.0to100.0%ofPVinputrange(EU)
(RP1≤RP2≤RP3≤RP4≤RP5≤
RP6≤RP7)
100.0%
ofPV
input
range
Table
below
STD
(RHY)
ZonePIDswitching
hysteresis
Hysteresiscanbesetforswitchingat
a reference point.
0.0to10.0%ofPVinputrangespan
(EUS)
0.5%
ofPV
input
range
span
(RDV) Referencedeviation
SetadeviationfromSP.
ThePIDforreferencedeviationis
usedifthereisalargerdeviation
thanthepresetreferencedeviation.
OFF:Disable
0.0+1digitto100.0%ofPVinput
rangespan(EUS)
OFF
ForZonecontrol,setthesetupparameterZON (zone PID selection)toZonePID
selection.
Usethefollowingtabletorecordthereferencepointsettingvalue.
Parameter n=1 n=2 n=3 n=4 n=5 n=6 n=7
RPn
■P Parameter (for Ladder Program)
Menusymbol: (PPAR)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
to
(P01toP30)
P01toP30parameter
-19999to30000(Setadecimalpoint
positionusingLL50AParameterSet-
tingSoftware.)
0Table
below STD
Parameter n=01 n=02 n=03 n=04 n=05 n=06 n=07 n=08 n=09 n=10
Pn
Parameter n=11 n=12 n=13 n=14 n=15 n=16 n=17 n=18 n=19 n=20
Pn
Parameter n=21 n=22 n=23 n=24 n=25 n=26 n=27 n=28 n=29 n=30
Pn
■10-segment Linearizer-1, -2 Setting Parameter
Menusymbol: (PYS1) (PYS2)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(PYS)
10-segmentlinearizer
selection
OFF:Disable
PV:PVanaloginput
PV2:PV2analoginput
AIN2:AIN2analoginput
AIN4:AIN4analoginput
PVIN:PVinput
OUT:OUTanalogoutput
OUT2:OUT2analogoutput
RET:RETanalogoutput
PV2IN:PV2input
20PV:20-segmentlinearizer,PVanaloginput
20PV2:20-segmentlinearizer,PV2analoginput
20AI2:20-segmentlinearizer,AIN2analoginput
20AI4:20-segmentlinearizer,AIN4analoginput
LDR10:10-segmentlinearizer,usedbythe
ladderprogram
LDR20:20-segmentlinearizer,usedbythe
ladderprogram
PV
(CTLM
:
SGL)
STD
(A1)
10-segmentlinearizer
input 1
-66.7to105.0%ofinputrange(EU)
Outputlinearizer:-5.0to105.0% 0.0%
(B1)
10-segmentlinearizer
output 1
10-segmentlinearizerbias:-66.7to
105.0%ofinputrangespan(EUS)
10-segmentlinearizerapproximation:
-66.7to105.0%ofinputrange(EU)
Outputlinearizer:-5.0to105.0%
0.0%
to
,
to
(A2toA11,
B2toB11)
10-segmentlinearizer
input 2 to 11
10-segmentlinearizer
output 2 to 11
SameasA1andB1
Same
as
A1
and
B1 STD
(PMD)
10-segmentlinearizer
mode
0:10-segmentlinearizerbias
1:10-segmentlinearizer
approximation
0
Usethefollowingtabletorecordthe10-segmentlinearizerinputandoutputsettingvalues.
Parameter n=2 n=3 n=4 n=5 n=6 n=7 n=8 n=9 n=10 n=11
An
Bn
Setup Parameters
HolddownthePARAMETERkeyandLeftarrowkeysimultaneouslyfor3secondsto
movefromtheOperationDisplayorOperationParameterSettingDisplaytotheSetup
ParameterSettingDisplay.
PresstheDISPLAYkeyoncetoreturntotheOperationDisplay.
Menu
DISPLAY key
SET/ENTER key
PARAMETER key
key key key
key key
Operation Dsipaly
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
END
Menu
END
Menu END
END
Menu Display and
Parameter Setting
Display are changed
in a circular pattern.
Move to the Operation Parameter Setting Display:
Hold down the PARAMETER key for 3 sec.
Hold down PARAMETER key and
Left arrow key simultaneously for 3 sec.
Operation for Setting
· Toselecttheparametersettingdisplayedastheinitialvalue,presstheDownarrow
keytomovetothenextparameter.
· Tochangeandsettheparametersetting,presstheSET/ENTERkeytostarttheset-
pointblinking.Theblinkingstateallowsyoutomakechanges(settingmode).Usethe
Up/Down/Left/Rightarrowkeystochangethesetpoint.PresstheSET/ENTERkeyto
registerthesetting.
NotethattherearesomeparameterswhicharenotdisplayeddependingontheModel
andSufxcodes,controlmode(CTLM),controltype(CNT),etc.Theparametersfor
professionalsettingmode(LEVL:PRO)arenotdescribedinthismanual.SeeUser’s
Manual.
■Control Function Setting Parameter
Menusymbol: (CTL)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(CTLM) Controlmode
Whenusingthecontrolsotherthan
Single-loopcontrol,seeUser's
Manual.
SGL STD
SGL:Single-loopcontrol
CAS1:Cascadeprimary-loopcontrol
CAS2:
Cascadesecondary-loopcontrol
CAS:Cascadecontrol
BUM:Loopcontrolforbackup
PVSW:
LoopcontrolwithPVswitching
PVSEL:L
oopcontrolwithPVauto-selector
PVHD:
LoopcontrolwithPV-holdfunction
2LP:Dual-loopcontrol
(CNT) Controltype
PID:PIDcontrol
ONOF:ON/OFFcontrol(1pointof
hysteresis)
ONOF2:ON/OFFcontrol(2pointsof
hysteresis)
2P2L:Two-positiontwo-levelcontrol
H/C:Heating/coolingcontrol
S-PI:SamplePIcontrol
BATCH:BatchPIDcontrol
FFPID:Feedforwardcontrol
PID
or
H/C
(for
Heat-
ing/
Cooling
type)
EASY
(SPGR.) NumberofSPgroups SetanumberofSPgroupstouse.
1to20 8
STD
(ZON) ZonePIDselection
Ifsetto“SPgroupnumberselection,”
allowsPIDconstantstobeselected
foreachSPgroup.
Ifsetto“ZonePIDselection,”
automaticallyselectsPIDconstants
accordingtotherangesetinthe
Referencepoint.
0:SPgroupnumberselection1
1:
ZonePIDselection(selectionbyPV)
2:ZonePIDselection(selectionby
targetSP)
3:SPgroupnumberselection2
4:
ZonePIDselection(selectionbySP)
0
(PGTY)
Programpatternaction
type
0:Notused.
1:Theprogrampatternforloop-1can
beused.
2:Theprogrampatternforloop-1and
theprogrampattern-2retransmis-
sioncanbeused.
3:Theprogrampatternforloop-1and
loop-2canbeused.
0
(PIDG.) NumberofPIDgroups SetanumberofPIDgroupstouse.
1 to 16 8
STD
(SMP)
Inputsamplingperiod
(controlperiod) 50:50ms,100:100ms,200:200ms 100
(SRPG)
STOP/RUNactionfor
programoperation
InterlockingcontrolofRUN/STOP
switchofprogramoperation(PROG)
andSTOP/RUNswitch(S.R).
OFF:
Cannotbeoperatedsimultaneously
ON:Canbeoperatedsimultaneously
OFF EASY
■PVInputSettingParameter
Menusymbol: (PV)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(IN) PVinputtype
OFF:Disable
K1:-270.0to1370.0
0
C/-450.0to2500.0
0
F
K2:-270.0to1000.0
0
C/-450.0to2300.0
0
F
K3:-200.0to500.0
0
C/-200.0to1000.0
0
F
J:-200.0to1200.00C/-300.0to2300.0 0F
T1:-270.0to400.0
0
C/-450.0to750.0
0
F
T2:0.0to400.0
0
C/-200.0to750.0
0
F
B:0.0to1800.00C/32to3300 0F
S:0.0to1700.00C/32to3100 0F
R:0.0to1700.00C/32to3100 0F
N:-200.0to1300.0
0
C/-300.0to2400.0
0
F
E:-270.0to1000.0
0
C/-450.0to1800.0
0
F
L:-200.0to900.0
0
C/-300.0to1600.0
0
F
U1:-200.0to400.0
0
C/-300.0to750.0
0
F
U2:0.0to400.00C/-200.0to1000.0 0F
W:0.0to2300.00C/32to4200 0F
PL2:0.0to1390.0
0
C/32.0to2500.0
0
F
P2040:0.0to1900.0
0
C/32to3400
0
F
WRE:0.0to2000.00C/32to3600 0F
JPT1:-200.0to500.00C/-300.0to1000.0 0F
JPT2:
-150.00to150.00
0
C/-200.00to300.00
0
F
PT1:-200.0to850.0
0
C/-300.0to1560.0
0
F
PT2:-200.0to500.0
0
C/-300.0to1000.0
0
F
PT3:-150.00to150.00
0
C/-200.0to300.0
0
F
0.4-2V:0.400to2.000V
1-5V:1.000to5.000V
4-20:4.00to20.00mA
0-2V:0.000to2.000V
0-10V:0.00to10.00V
0-20:0.00to20.00mA
-1020:-10.00to20.00mV
0-100:0.0to100.0mV
OFF
EASY
(UNIT) PVinputunit
-:Nounit,C:DegreeCelsius
-:Nounit,--:Nounit,---:Nounit,
F:DegreeFahrenheit
C
(RH)
MaximumvalueofPV
inputrange
Dependsontheinputtype.
-Fortemperatureinput-
Setthetemperaturerangethatis
actuallycontrolled.(RL<RH)
-Forvoltage/currentinput-
Settherangeofavoltage/current
signalthatisapplied.
Thescaleacrosswhichthevoltage/
currentsignalisactuallycontrolled
shouldbesetusingthemaximum
valueofinputscale(SH)andmini-
mumvalueofinputscale(SL).
(Inputisalways0%whenRL=RH.)
Depends
on the
input type
(RL)
MinimumvalueofPV
inputrange
Depends
on the
input type
(SDP)
PVinputscaledecimal
point position
0:Nodecimalplace
1:Onedecimalplace
2: Two decimal places
3: Three decimal places
4: Four decimal places
Depends
on the
input type
(SH)
MaximumvalueofPV
input scale -19999to30000,(SL<SH),
|SH-SL|≤30000
Depends
on the
input type
(SL)
MinimumvalueofPV
input scale
Depends
on the
input type
(BSL)
PVinputburnoutaction
OFF:Disable
UP:Upscale
DOWN:Downscale
Depends
on the
input type
STD
(A.BS)
PVanaloginputbias
-100.0to100.0%ofPVinputrange
span(EUS)
0.0%of
PVinput
range
span
(A.FL)
PVanaloginputlter
OFF,1to120s
OFF
W:W-5%Re/W-26%Re(HoskinsMfg.Co.).ASTME988,WRE:W97Re3-W75Re25
■PV2InputSettingParameter(E1-terminalArea)
Menusymbol: (PV2)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(IN) PV2inputtype SameasPVinputtype 1-5V
EASY
(UNIT) PV2inputunit
-:Nounit,C:DegreeCelsius
-:Nounit,--:Nounit,---:Nounit,
F:DegreeFahrenheit
C
(RH)
MaximumvalueofPV2
inputrange
Dependsontheinputtype.
-Fortemperature(/DRoption)input-
Setthetemperaturerangethatis
actuallycontrolled.(RL<RH)
-Forvoltage/current(/DRoption)input-
Settherangeofavoltage/current
signalthatisapplied.
Thescaleacrosswhichthevoltage/
currentsignalisactuallycontrolled
shouldbesetusingthemaximum
valueofinputscale(SH)andmini-
mumvalueofinputscale(SL).
(Inputisalways0%whenRL=RH.)
Depends
on the
input type
(RL)
MinimumvalueofPV2
inputrange
Depends
on the
input type
OperationParameters(Continuedfrompage11)

IM 05P01B41-11EN page 13/14
(SDP)
PV2inputscaledecimal
point position
0:Nodecimalplace
1:Onedecimalplace
2: Two decimal places
3: Three decimal places
4: Four decimal places
Depends
on the
input type
EASY
(SH)
MaximumvalueofPV2
input scale -19999to30000,(SL<SH),
|SH-SL|≤30000
Depends
on the
input type
(SL)
MinimumvalueofPV2
input scale
(BSL) PV2inputburnoutaction
OFF:Disable
UP:Upscale
DOWN:Downscale
Depends
on the
input type
STD
(RTD.S) RTDwiringsystem 3-W:3-wiresystem
4-W:4-wiresystem 3-W
■AIN2 Aux. Analog Input/AIN4 Remote Input Setting
Parameter (E2/E4-terminal Area)
Menusymbol: (AIN2) (AIN4)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(IN)
AIN2aux.analoginput
type
AIN4remoteinputtype
0.4-2V:0.400to2.000V
1-5V:1.000to5.000V
0-2V:0.000to2.000V
0-10V:0.00to10.00V
0-125:0.000to1.250V
1-5V
EASY
(UNIT)
AIN2aux.analoginput
unit
AIN4remoteinputunit
-:Nounit
C:DegreeCelsius
-:Nounit,--:Nounit,---:Nounit
F:DegreeFahrenheit
C
(RH)
MaximumvalueofAIN2
aux.analoginputrange
MaximumvalueofAIN4
remoteinputrange
Dependsontheinputtype.
Settherangeofavoltagesignalthat
is applied.
Thescaleacrosswhichthevoltage
signalisactuallycontrolledshouldbe
setusingthemaximumvalueofinput
scale(SH)andminimumvalueof
inputscale(SL).
(Inputisalways0%whenRL=RH.)
Depends
on the
input type
(RL)
MinimumvalueofAIN2
aux.analoginputrange
MinimumvalueofAIN4
remoteinputrange
(SDP)
AIN2aux.analoginput
scale decimal point posi-
tion
AIN4remoteinputscale
decimal point position
0:Nodecimalplace
1:Onedecimalplace
2: Two decimal places
3: Three decimal places
4: Four decimal places
Depends
on the
input type
(SH)
MaximumvalueofAIN2aux.
analoginputscale
MaximumvalueofAIN4
remote input scale
-19999to30000,(SL<SH),
|SH-SL|≤30000
Depends
on the
input type
(SL)
MinimumvalueofAIN2aux.
analoginputscale
MinimumvalueofAIN4
remote input scale
(BSL)
AIN2aux.analoginput
burnoutaction
AIN4remoteinputburn-
out action
OFF:Disable
UP:Upscale
DOWN:Downscale
Depends
on the
input type
STD
■Input Range, SP Limiter Setting Parameter
Menusymbol: (MPV)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(P.UNI) ControlPVinputunit
-:Nounit
C:DegreeCelsius
-:Nounit,--:Nounit,---:Nounit
F:DegreeFahrenheit
Same
asPV
input
unit
STD
(P.DP)
ControlPVinputdecimal
point position
0:Nodecimalplace
1:Onedecimalplace
2: Two decimal places
3: Three decimal places
4: Four decimal places
Depends
on the
input type
(P.RH)
Maximumvalueof
controlPVinputrange -19999to30000,(P.RL<P.RH),
|P.RH-P.RL|≤30000
Depends
on the
input type
(P.RL)
Minimumvalueofcontrol
PVinputrange
(SPH) SPhighlimit 0.0to100.0%ofPVinputrange(EU),
(SPL<SPH)
*SPHandSPLdonotwork,when
creatingtheprogrampattern.
100.0%
ofPV
input
range
(SPL) SP low limit
0.0%
ofPV
input
range
■Output Setting Parameter
Menusymbol: (OUT)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(OT)
Outputtypeselection
Upper two
digits Lower two
digits
ControloutputorHeating-sidecontrol
output(Lowertwodigits)
00:OFF
01:OUTterminals(voltagepulse)
02:OUTterminals(current)
03:OUTterminals(relay)
04:OUT2terminals(voltagepulse)
05:OUT2terminals(current)
06:OUT2terminals(relay)
07:RETterminals(voltagepulse)
08:RETterminals(current)
09:AL3terminals(relay)
10:AL2terminals(relay)
Cooling-sidecontroloutput(Uppertwodigits)
00:OFF
01:OUTterminals(voltagepulse)
02:OUTterminals(current)
03:OUTterminals(relay)
04:OUT2terminals(voltagepulse)
05:OUT2terminals(current)
06:OUT2terminals(relay)
07:RETterminals(voltagepulse)
08:RETterminals(current)
09:AL3terminals(relay)
10:AL2terminals(relay)
Standard
type:
00.03
EASY
(CT)
Controloutputcycletime
Heating-sidecontrol
outputcycletime(in
Heating/coolingcontrol) 0.5to1000.0s
30.0s
EASY
(CTc)
Cooling-sidecontrol
output cycle time 30.0s
(V.AT)
Automaticvalveposition
adjustment
OFF:Stopautomaticadjustment
ON:Startautomaticadjustment OFF
(V.RS)
Valvepositionsetting
reset
SettingV.RStoONresetsthevalve
adjustmentsettingsandcausesthe
indication“V.RS”toblink.
OFF
(V.L)
Fully-closedvalveposi-
tionsetting
PressingtheSET/ENTERkeywith
valvepositionsettothefully-closed
positionbyDownarrowkeycauses
theadjustedvaluetobestored.When
V.Ladjustmentiscomplete,V.Lstops
blinking.
105.0
(V.H)
Fully-openedvalveposi-
tionsetting
PressingtheSET/ENTERkeywith
valvepositionsettothefully-opened
positionbyUparrowkeycausesthe
adjustedvaluetobestored.WhenV.H
adjustmentiscomplete,V.Hstops
blinking
105.0
(TR.T) Valvetravelingtime 5to300s 60s
STD
(V.MOD) Valveadjustingmode
0:Valvepositionfeedbacktype
1:Valvepositionfeedbacktype
(movestotheestimatingtypeifa
feedbackinputerrororbreakoc-
curs.)
2:Valvepositionestimatingtype
0
(RTS)
Retransmissionoutput
typeofRET
OFF:Disable
PV1:PV
SP1: SP
OUT1:OUT(Valveopening:0to
100%inPositionproportionalcontrol)
LPS:15VDClooppowersupply
PV2:Loop-2PV
SP2:Loop-2SP
OUT2:Loop-2OUT
TSP1:TargetSP
HOUT1:Heating-sideOUT
COUT1:Cooling-sideOUT
MV1:Positionproportionaloutput
(internalcomputedvalue)
TSP2:Loop-2targetSP
HOUT2:Loop-2heating-sideOUT
COUT2:Loop-2cooling-sideOUT
MV2:Loop-2positionproportional
output(internalcomputedvalue)
PV:PVterminalsanaloginput
A.PV2:PV2terminalsanaloginput
AIN2:AIN2terminalsanaloginput
AIN4:AIN4terminalsanaloginput
*Loop-2settingvaluesare
unavailable
inSingle-loopcontrol.
PV1 EASY
(RTH)
Maximumvalueof
retransmission output
scaleofRET
WhenRTS=PV1,SP1,PV2,SP2,
TSP1,TSP2,PV,A.PV2,AIN2,or
AIN4,RTL+1digitto30000
-19999toRTH-1digit
Decimalpointposition:
WhenRTS=PV1,SP1,orTSP1,
decimal point position is same as
thatofPVinput.
WhenRTS=PV2,SP2,orTSP2,
decimal point position is same as
thatofPV2input.
WhenRTS=PV,decimalpointposition
issameasthatofPVinputscale.
WhenRTS=A.PV2,decimalpoint
positionissameasthatofPV2
input scale.
WhenRTS=AIN2,decimalpointposi-
tionissameasthatofAIN2scale.
WhenRTS=AIN4,decimalpointposi-
tionissameasthatofAIN4scale.
100%
ofPV
input
range
STD
(RTL)
Minimumvalueof
retransmission output
scaleofRET
0%
ofPV
input
range
(O1RS)
Retransmissionoutput
typeofOUTcurrent
output
SameasRTS
OFF
STD
(O1RH)
Maximumvalueof
retransmission output
scaleofOUTcurrent
output
WhenO1RS=PV1,SP1,PV2,SP2,
TSP1,TSP2,PV,A.PV2,AIN2,or
AIN4,O1RL+1digitto30000
-19999toO1RH-1digit
Decimalpointposition:
WhenO1RS=PV1,SP1,orTSP1,decimal
pointpositionissameasthatofPV
input.
WhenO1RS=PV2,SP2,orTSP2,
decimal point position is same as that
ofPV2input.
WhenO1RS=PV,decimalpointposition
issameasthatofPVinputscale.
WhenO1RS=
A.PV2,decimalpointposi-
tionissameasthatofPV2inputscale.
WhenO1RS=AIN2,decimalpointposi-
tionissameasthatofAIN2scale.
WhenO1RS=AIN4,decimalpointposi-
tionissameasthatofAIN4scale.
-
(O1RL)
Minimumvalueof
retransmission output
scaleofOUTcurrent
output
-
(O2RS)
Retransmissionoutput
typeofOUT2current
output
SameasRTS
OFF
STD
(O2RH)
Maximumvalueof
retransmission output
scaleofOUT2current
output
WhenO2RS=PV1,SP1,PV2,SP2,
TSP1,TSP2,PV,A.PV2,AIN2,or
AIN4,O2RL+1digitto30000
-19999toO2RH-1digit
Decimalpointposition:
WhenO2RS=PV1,SP1,orTSP1,
decimal point position is same as
thatofPVinput.
WhenO2RS=PV2,SP2,orTSP2,
decimal point position is same as
thatofPV2input.
WhenO2RS=PV,decimalpointposi-
tionissameasthatofPVinput
scale.
WhenO2RS=A.PV2,decimalpoint
positionissameasthatofPV2
input scale.
WhenO2RS=AIN2,decimalpoint
positionissameasthatofAIN2
scale.
WhenO2RS=AIN4,decimalpoint
positionissameasthatofAIN4
scale.
-
(O2RL)
Minimumvalueof
retransmission output
scaleofOUT2current
output
-
(OU.A)
OUTcurrentoutput
range
4-20:4to20mA
0-20:0to20mA
20-4:20to4mA
20-0:20to0mA
4-20
STD
(OU2.A)
OUT2currentoutput
range 4-20
(RET.A)
RETcurrentoutput
range 4-20
■
RS-485 Communication Setting Parameter (E3/E4-terminal Area)
Menusymbol: (R485)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(PSL) Protocol selection
PCL:PClinkcommunication
PCLSM:PClinkcommunication(with
checksum)
LADR:Laddercommunication
CO-M:Coordinatedmasterstation
CO-S:Coordinatedslavestation
MBASC:Modbus(ASCII)
MBRTU:Modbus(RTU)
CO-M2:Coordinatedmasterstation
(Loop-2mode)
CO-S1:Coordinatedslavestation
(Loop-1mode)
CO-S2:Coordinatedslavestation
(Loop-2mode)
P-P:Peer-to-peercommunication
MBRTU
EASY
(BPS) Baud rate
600:600bps
1200:1200bps
2400:2400bps
4800:4800bps
9600:9600bps
19200:19.2kbps
38400:38.4kbps
*ThebaudrateforRS-485isupto
19.2kbpsinE4-terminalarea.
19200
(PRI) Parity
NONE:None
EVEN:Even
ODD:Odd
EVEN
(STP) Stopbit 1:1bit,2:2bits 1
(DLN) Datalength 7:7bits,8:8bits 8
(ADR) Address 1to99 1
■
Ethernet Communication Setting Parameter (E3-terminal Area)
Menusymbol: (ETHR)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(HSR)
High-speedresponse
mode OFF,1to8 1
EASY
(BPS) Baud rate
9600:9600bps
19200:19.2kbps
38400:38.4kbps
38400
(PRI) Parity
NONE:None
EVEN:Even
ODD:Odd
EVEN
EASY
to
(IP1toIP4)
IP address 1 to 4
0to255
Initialvalue:
(IP1).(IP2).(IP3).(IP4)
=(192).(168).(1).(1)
See left Table
below
to
(SM1toSM4)
Subnetmask1to4
0to255
Initialvalue:(SM1).(SM2).(SM3).
(SM4)
=(255).(255).(255).(0)
See left Table
below
to
(DG1toDG4)
Defaultgateway1to4
0to255
Initialvalue:(DG1).(DG2).(DG3).
(DG4)
=(0).(0).(0).(0)
See left Table
below
(PRT) Portnumber 502,1024to65535 502
(IPAR) IP access restriction OFF:Disable,ON:Enable OFF
to
,
to
(1.IP1to1.IP4,
2.IP1to2.IP4)
PermittedIPaddress1-1
to1-4
PermittedIPaddress2-1
to2-4
0to255
Initialvalue:
(1.IP1).(1.IP2).(1.IP3).(1.IP4)
=(255).(255).(255).(255)
(2.IP1).(2.IP2).(2.IP3).(2.IP4)
=(255).(255).(255).(255)
See left Table
below
(ESW) Ethernetsettingswitch
Settingthisparameterto“ON”
enablestheEthernetcommunication
parametersettings.
OFF,ON
OFF
UsethefollowingtabletorecordEthernetcommunicationsettingvalue.
Parameter n=1 n=2 n=3 n=4
IPn
SMn
DGn
1.IPn
2.IPn
■
PROFIBUS-DP Communication Setting Parameter (E3-terminal Area)
Menusymbol: (PROF)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(BR) Baud rate
9.6K:9.6kbps
19.2K:19.2kbps
93.75K:93.75kbps
187.5K:187.5kbps
0.5M:0.5Mbps
1.5M:1.5Mbps
3M:3Mbps
6M:6Mbps
12M:12Mbps
AUTO
45.45K:45.45kbps
AUTO
EASY
(ADR) Address 0to125 3
(BPS) Baud rate
9600:9600bps
19200:19.2kbps
38400:38.4kbps
38400
(FILE) Prolenumber 0,21to25 0
■
DeviceNet Communication Setting Parameter (E3-terminal Area)
Menusymbol: (DNET)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(BR) Baud rate
125K:125kbps
250K:250kbps
500K:500kbps 125K
EASY
(ADR) Address 0to63 63
(BPS) Baud rate
9600:9600bps
19200:19.2kbps
38400:38.4kbps
38400
(FILE) Prolenumber 0,21to25 0
■
CC-Link Communication Setting Parameter (E3-terminal Area)
Menusymbol: (CC-L)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(BR) Baud rate
156K:156kbps
625K:625kbps
2.5K:2.5kbps
5M:5Mbps
10M:10Mbps
10M
EASY
(ADR) Address 1 to 64 1
(BPS) Baud rate
9600:9600bps
19200:19.2kbps
38400:38.4kbps
38400
(FILE) Prolenumber 0,21to25 0
SetupParameters(Continuedfrompage12)

IM 05P01B41-11EN page 14/14
■KeyActionSettingParameter
Menusymbol: (KEY)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(F1)
Userfunctionkey-1
actionsetting
OFF:Disable
A/M:AUTO/MANswitch
C/A/M:CAS/AUTO/MANswitch
R/L1:REM/LCLswitch
R/L2:Loop-2REM/LCLswitch
S/R:STOP/RUNswitch
CAS:SwitchtoCAS
AUTO:SwitchtoAUTO
MAN:SwitchtoMAN
REM1:SwitchtoREM
LCL1:SwitchtoLCL
REM2:SwitchtoLoop-2REM
LCL2:SwitchtoLoop-2LCL
STOP:SwitchtoSTOP
RUN:SwitchtoRUN
AT:Auto-tuning
LTUP:LCDbrightnessUP
LTDN:LCDbrightnessDOWN
BRI:AdjustLCDbrightness
LCD:LCDbacklightON/OFFswitch
LAT:Latchrelease
PID:PIDtuningswitch
HLD:Startofhold-modeoperation
ADV:Advanceofsegment
HOME:Homedisplayswitch
LPCH:Loop-1/Loop-2displayswitch
A/MS:
DisplayingloopAUTO/MANswitch
R/LS:
DisplayingloopREM/LCLswitch
S/RS:
DisplayingloopSTOP/RUNswitch
AUTS:
SwitchtoAUTOdisplayingloop
MANS:SwitchtoMANdisplayingloop
REMS:SwitchtoREMdisplayingloop
LCLS:SwitchtoLCLdisplayingloop
STPS:
SwitchtoSTOPdisplayingloop
RUNS:SwitchtoRUNdisplayingloop
ATS:Displayingloopauto-tuning
PIDS:
PIDtuningswitchdisplayingloop
P.RUN:Startofprogramoperation
P.STP:Stopofprogramoperation
*Loop-2settingvaluesareunavail-
ableinSingle-loopcontrol.
OFF
EASY
(F2)
Userfunctionkey-2
actionsetting OFF
(Fn)
Userfunctionkey-n
actionsetting PID
■DisplayFunctionSettingParameter
Menusymbol: (DISP)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(DVB) Deviationdisplayband
Permitsachangeinthespanof
deviationshownonthefront-panel
deviationmonitor.
0.0to100.0%ofPVinputrangespan(EUS).
1.0%
ofPV
input
range
span
STD
(PCMD)
ActivecolorPVdisplay
switch
0:Fixedinwhite
1:Fixedinred
2:Linktoalarm1(AlarmOFF:white,
AlarmON:red)
3:Linktoalarm1(AlarmOFF:red,
AlarmON:white)
4:Linktoalarm1or2(AlarmOFF:
white,AlarmON:red)
5:Linktoalarm1or2(AlarmOFF:
red,AlarmON:white)
6:PVlimit(Withinrange:white,Out
ofrange:red)
7:PVlimit(Withinrange:red,Outof
range:white)
8:SPdeviation(Withindeviation:
white,Outofdeviation:red)
9:SPdeviation(Withindeviation:red,
Outofdeviation:white)
10:LinktoDI(ON:red,OFF:white)
0
EASY
(PCH)
PVcolorchangehigh
limit
SetadisplayvaluewheninPVlimit
orSPdeviation.
-19999to30000(Setavaluewithin
theinputrange.)
Decimalpointpositiondependson
the input type.
0
(PCL) PVcolorchangelowlimit 0
(BAR1)
Upperbar-graphdisplay
registration
0:Disable
1:OUT,
Heating-sideOUT,Internal
valueinPositionproportionalcontrol
2:Cooling-sideOUT
3:PV
4: SP
5:Deviation
6:
Loop-2OUT,Loop-2heating-sideOUT
7:Loop-2cooling-sideOUT
8:Loop-2PV
9:Loop-2SP
10:Loop-2deviation
11to16:Disable
17:Feedbackinput(valveopening)
18:PVterminalsanaloginput
19:PV2terminalsanaloginput
20:AIN2terminalsanaloginput
21:AIN4terminalsanaloginput
22:DisplayloopHeating-sideOUT,
InternalvalueinPositionpropor-
tional control
23:DisplayloopCooling-sideOUT
24:DisplayloopPV
25:DisplayloopSP
26:DisplayloopDeviation
27:TSP,28:TSPdeviation
29:Loop-2TSP
30:Loop-2TSPdeviation
5
)
STD
(BAR2)
Lowerbar-graphdisplay
registration
1
(Posi-
tion
propor-
tional
type:
17)
(BDV)
Bar-graphdeviation
displayband
0.0to100.0%ofPVinputrangespan
(EUS)
1.0%
ofPV
input
range
span STD
(GUID) GuidedisplayON/OFF OFF:Nondisplay,ON:Display ON
(ECO) Economymode
OFF:Disable
1:EconomymodeON(Allindications
exceptPVdisplayOFF)
2:
EconomymodeON(AllindicationsOFF)
3:Brightness10%(wholeindication)
OFF STD
(BRI) Brightness (Dark)1to5(Bright) 3EASY
(MLSD)
Leastsignicantdigital
maskofPVdisplay
OFF:Withleastsignicantdigit
ON:Withoutleastsignicantdigit OFF
STD
(MKTP)
Methodforleastsignicant
digitalmaskofPVdisplay
0:Rounding,1:Rounding-off 0
(SW.LP) Loop1/2dsiplayswitch 1LP:Loop1
2LP:Loop2 1LP
■SELECTDisplaySettingParameter
Menusymbol: (CSEL)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
to
(CS1toCS5)
SELECTDisplay-1to-5
registration
Registertheoperationparameter(except
theOperationMode)thatisfrequentlymod-
iedtodisplayitintheOperationDisplay.
OFF,2301to10000
Forthesettingrange,seeUser'sManual.
OFF STD
UsethefollowingtabletorecordSELECTDisplaysettingvalue.
Parameter n=1 n=2 n=3 n=4 n=5
CSn
■KeyLockSettingParameter
Menusymbol: (KLOC)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(COM.W)
Communicationwrite
enable/disable OFF:Enable,ON:Disable OFF
STD
(DATA)
Front panel parameter
data(▼,▲)keylock
OFF:Unlock,ON:Lock
OFF
(A/M) FrontpanelA/Mkeylock OFF
■DIFunctionRegistrationParameter
Menusymbol: (DI.SL)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(A/M) AUTO/MANswitch
SetanIrelaynumberofcontact
input.
Set“OFF”todisablethefunction.
Standard terminals
DI1:5025,DI2:5026,DI3:5027
E2-terminalarea
DI26:5062
E1-terminalarea
DI11:5041,DI12:5042,DI13:5043,
DI14:5044,DI15:5045
E3-terminalarea
DI31:5073,DI32:5074,DI33:5075,
DI34:5076,DI35:5077
E4-terminalarea
DI41:5089,DI42:5090,DI43:5091,
DI44:5092,DI45:5093,DI46:5094
5025
STD
(R/L) REMOTE/LOCALswitch 5094
(S/R) STOP/RUNswitch 5026
(CAS) SwitchtoCAS OFF
(AUTO) SwitchtoAUTO OFF
(MAN) SwitchtoMAN OFF
(REM) SwitchtoREMOTE OFF
(LCL) SwitchtoLOCAL OFF
(ADV) Advanceofsegment OFF
(HOLD) HoldON/OFFswitch OFF
(AT)
Auto-tuningSTART/STOP
switch
OFF
(LAT) Latchrelease OFF
(LCD)
LCDbacklightON/OFF
switch
OFF
(PVRW) PVred/whiteswitch OFF
(P.RUN)
Runswitchofprogram
operation OFF
(P.STP)
Stopswitchofprogram
operation OFF
■DIFunctionNumberingParameter
Menusymbol: (DI.NU)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(SP.B0) Bit-0ofSPnumber
Seenextparagraph.
OFF
EASY
(SP.B1) Bit-1ofSPnumber OFF
(SP.B2) Bit-2ofSPnumber OFF
(SP.B3) Bit-3ofSPnumber
Seenextparagraph.
OFF
EASY
(SP.B4) Bit-4ofSPnumber OFF
(PN.B0) Bit-0ofPIDnumber
SetanIrelaynumberofcontactinput.
Set“OFF”todisablethefunction.
Standard terminals
DI1:5025,DI2:5026,DI3:5027
E2-terminalarea
DI26:5062
E1-terminalarea
DI11:5041,DI12:5042,DI13:5043,
DI14:5044,DI15:5045
E3-terminalarea
DI31:5073,DI32:5074,DI33:5075,
DI34:5076,DI35:5077
E4-terminalarea
DI41:5089,DI42:5090,DI43:5091,
DI44:5092,DI45:5093,DI46:5094
OFF
STD
(PN.B1) Bit-1ofPIDnumber OFF
(PN.B2) Bit-2ofPIDnumber OFF
(PN.B3) Bit-3ofPIDnumber OFF
(PN.B4) Bit-4ofPIDnumber OFF
(MP.B0)
Bit-0ofmanualpreset
outputnumber OFF
(MP.B1)
Bit-1ofmanualpreset
outputnumber OFF
(MP.B2)
Bit-2ofmanualpreset
outputnumber OFF
(SP.BC)
Bitchangingmethodof
SPnumber
0:Statusswitch1
1: Status switch 2 0 STD
■AL1-AL3FunctionRegistrationParameter
Menusymbol: (ALM)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(AL1.S) AL1functionselection
SetanIrelaynumber.Fortheitems
otherthanbelow,seeCommunication
User'sManual.
Ex.)Setthenumber4353forAL1.S
to use the alarm 1.
Set“OFF”todisablethefunction.
Nofunction:OFF
Alarm1:4353
Alarm2:4354
Alarm3:4355
Alarm4:4357
Alarm5:4358
Alarm6:4359
Alarm7:4361
Alarm8:4362
AUTO(OFF)/MAN(ON)status:4193
REM(ON)/LCL(OFF)status:4194
STOP(ON)/RUN(OFF)status:4195
Outputtracking(ON)switchingsignal:4201
FAIL(NormallyON)output:4256
4353
STD
(AL2.S) AL2functionselection 4354
(AL3.S) AL3functionselection 4355
(OR.S)
OUTrelayfunction
selection OFF
(OR2.S)
OUT2relayfunction
selection OFF
■DOSettingParameter(E2-terminalArea)
Menusymbol: (DO)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(DO1.S) DO21functionselection
SameasAL1.S
Set“OFF”todisablethefunction.
Initialvalue:
DO21=4357,DO22=4358,
DO23=4359,DO24=4361,
DO25=4362
See left
STD
(DO2.S) DO22functionselection See left
(DO3.S) DO23functionselection See left
(DO4.S) DO24functionselection See left
(DO5.S) DO25functionselection See left
■SystemSettingParameter
Menusymbol: (SYS)
Parameter
symbol Name of Parameter Setting Range Initial value User
setting
Display
level
(R.MD) Restartmode
Set how the controller should
recoverfromapowerfailureof5
seconds or more.
CONT:Continueactionsetbefore
power failure.
MAN:StartfromMAN.
AUTO:StartfromAUTO.
CONT2:Continueactionset
beforepowerfailure.Preset
output starts.
CONT
STD
(R.TM) Restarttimer
Settimebetweenpoweronand
the instant where controller starts
computation.
0to10s
0
(EPO) Input error preset output
Setpresetoutputvaluewhenthe
inputburnoutorADCerroroccurs.
Manualoutputisprioritizedwhen
theinputburnoutoccursinMAN.
0:Presetoutput
1:0%output
2:100%output
0
(FREQ) Powerfrequency AUTO,60:60Hz,50:50Hz AUTO
EASY
(QSM) Quicksettingmode OFF:Disable
ON:Enable ON
(LANG) Guidedisplaylanguage
ENG:English
SPA:Spanish
*GermanandFrenchguide
displaysarecustomized.
Contactourrepresentativesfor
inquiries.
Depe-
nds on the
model and
sufxcodes EASY
(PASS) Passwordsetting 0(Nopassword)to65535 0
■
ErrorandVersionConrmationParameter(fordisplayonly)
Menusymbol: (VER)
Parameter
symbol Name of Parameter Status record
Display
level
(PA.ER) Parameter error status
EASY
(OP.ER) Optionerrorstatus
(AD1.E) A/Dconvertererrorstatus1
(AD2.E) A/Dconvertererrorstatus2
(PV1.E) Loop-1PVinputerrorstatus
(PV2.E) Loop-2PVinputerrorstatus
(LA.ER) Laddererrorstatus
(MCU) MCUversion
(DCU) DCUversion
(ECU1) ECU-1version(E1-terminalarea)
(ECU2) ECU-2version(E2-terminalarea)
(ECU3) ECU-3version(E3-terminalarea)
(ECU4) ECU-4version(E4-terminalarea)
(PARA) Parameterversion
(H.VER) Productversion
(SER1)Serialnumber1
(SER2) Serialnumber2
(MAC1) MACaddress1(E3-terminalarea)
(MAC2) MACaddress2(E3-terminalarea)
(MAC3) MACaddress3(E3-terminalarea)
*TheparametersforLoop-2areunavailableinSingle-loopcontrol.
■ParameterDisplayLevelParameter
Menusymbol: (LVL)
Parameter
symbol Name of Parameter Setting Range Initial
value
User
setting
Display
level
(LEVL) Parameterdisplaylevel
EASY:Easysettingmode
STD:Standardsettingmode
PRO:Professionalsettingmode
STD EASY
*ForProfessionalsettingmode,seeUser’sManual.
Trademarks
● Our product names or brand names mentioned in this manual are
the trademarks or registered trademarks of Yokogawa Electric Corporation.
● Adobe, Acrobat, and Postscript are either registered trademarks or trademarks
of Adobe Systems Incorporated.
● Ethernet is a registered trademark of XEROX Corporation in the United States.
● Modbus is a registered trademark of Schneider Electric.
● PROFIBUS-DP is a registered trademark of PROFIBUS User Organization.
● DeviceNet is a registered trademark of Open DeviceNet Vendor Association.
● CC-Link is a registered trademark of CC-Link Partner Association.
● We do not use the TM or ® mark to indicate these trademarks or
registered trademarks in this manual.
● All other product names mentioned in this manual are trademarks
or registered trademarks of their respective companies.
Table of contents
Popular Controllers manuals by other brands

Hoffman Controls
Hoffman Controls 865-3AA Series Recalibration Instructions

Watlow
Watlow PM PLUS 6 user guide

Sentera Controls
Sentera Controls TCMF8-DM Mounting and operating instructions

SMC Networks
SMC Networks LEFS Series Operation manual

HORNER
HORNER XL6 Series installation manual

ero electronic
ero electronic PKC user manual