UVCpectra TUBE ULTRA 300 User manual

Page | 1
UVCpectra TUBE ULTRA 300
UVCpecta StandAlone ULTRA 300
USERS MANUAL
Version 1.1
All rights reserverd. Users manual cannot be changed or copied.

Page | 2

Page | 3
INDEX Page #:
1- Company Information 3
2- Use area and Technical Specifications 3
3- Warning and Informative Signs 4
4- Standards 4
5- Safety Instructions 5
6- Handling and Carrying Information 5
7- Installation and assembly 6
8- Usage Instructions 6
9- Maintanence 8
10- Possible Faults and Troubleshooting 8
11- Warranty Clauses 9
Add1 – Spare Parts List 9
Add2 – EU Conformity Declaration 10
Add3 – Electrical Schema 11

Page | 4
1- Company Information
Company Name : LTC Light Trade Centre Aydinlatma San. ve Tic Ltd Sti
Address : İbrahim Karaoğlanoğlu Cad. No: 101 34418, Seyrantepe /
İstanbul Türkiye
2- Use Area and Technical Specifications
UVCpectra Ultra series are indoor air circulation units, help eliminate all kind of
microscopic germicidals.
Technical Specifications
UVCpectra Tube Ultra 300 UVCpectra Stand Alone Ultra 300
Dimensions 160 x 255 x 1470mm 600 x 400 x 1600mm
Electrical Power 230 Watts 230 Watts
Working Voltage 220 - 230 V 220 - 230 V
Frequency 50 Hz 50 Hz
IP Rating IP 54 IP 54
UVC irradiation at 254nm 75 Watts 75 Watts
Fan Power 25 Watts (max) 25 Watts (max)
Air Flow Rate 200 - 250 m3 / h * 200 - 250 m3 / h *
UVGI Elimination Rate >99.9% >99.9%
Installation Ceiling / Wall Stand Alone
Lamps 3 x 75 Watts 3 x 75 Watts
Operation Mode WiFi Controlled WiFi Controlled
* Air flow rate may change depending on the conditions of temperature, humidity and other
factors.

Page | 5
Photometric Data:
3- Warning and Informative Signs
Conformity to CE standards
Do not start the machine before reading users
manual
WARNING! Danger Sign.
Information Sign
Protective Ground Connection
High Voltage Hazard
Electrics / Electronics Unit.
Do not throw to waste bin.
UV IRRADIATION DANGER.
DO NOT EXPOSE THE EYE AND SKIN DIRECT!
4- Standards
EU Regulations Applied
2014/35 / EU Low Voltage Directive

Page | 6
5- Safety Instructions
Refer to the Users Manual for use and care details.
In case of any danger, stop the system and provide authorized persons.
Follow the warning signs and instructions
Do not use the system and components outside of intended useage area.
Ask for autharized person’s help if error light is blinking.
Opening of caps and parts may damage electrical components. Only authorized people
are advised to do so.
Ultraviolet C is hazardous to skin and eyes. Do not expose any skin, eyes of human or
animals.
Mercury (Hg) Content (Nom) 5.5 mg / lamp
A lamp breaking is extremely unlikely to have any impact on your health. If a lamp
breaks, ventilate the room for 30 minutes and remove the parts, preferably with
gloves. Put them in a sealed plastic bag and take it to your local waste facilities for
recycling. Do not use a vacuum cleaner.
DANGER: Risk Group 3 Ultra Violet product. These lamps emit highpower UV
radiation that can cause severe injury to skin and eyes. Avoid direct eye and skin
exposure to unshielded lamps. Use only in an enclosed environment which shields
users from the radiation.
Keep away from children’s reach
6- Handling and Carrying Information
Handle with care
Fluorescent Light bulbs are sensitive. Always handle and carry the unit in original
boxing
A lamp breaking is extremely unlikely to have any impact on your health. If a lamp
breaks, ventilate the room for 30 minutes and remove the parts, preferably with
gloves. Put them in a sealed plastic bag and take it to your local waste facilities for
recycling. Do not use a vacuum cleaner.

Page | 7
7- Installation and assembly
The products should be installed by authorized staff. Do not open the box before the technical
service arrives.
8- Usage Instructions
A- Manual Use ( All series )
1- Plug the system to 220V AC outlet
2- Switch ON position
3- The system will start working
B- Wifi Access ( ULTRA 300 series only)
1- Plug the system to 220V AC outlet
2- Switch ON position
3- Wait for the Wifi Light to turn orange
4- Use a computer with WiFi, and connect to Systems WiFi
(UVCPECTRA_XXXXXX)
5- Default WiFi key is “ uvcpectra ”
6- If the IP address is not automatically assigned to 192.168.4.X, manually change
your computers IP address to 192.168.4.10
7- Use a Chrome browser to log in to http://192.168.4.1
8- Enter default password : 1234
9- On the main screen, goto Connection menu on top right
10- Press Connect Device to WiFi
11- Select your WiFi network to connect to from the list
12- Enter your WiFi key in password area
13- Entering a static IP is advised for easy access later. (i.e. 192.168.0.100)
14- Consult your IP admin for IP address and Subnet Mask settings
A typical configuration is given below. Please note the IP address given. You
will need it to access the users interface.

Page | 8
15- The WiFi light should turn Green, if a successful connection to your WiFi is made
16- Disconnect your computer from UVCPECTRA WiFi Network, and connect to
your WiFi network
17- Type in the IP address of system to go to user interface. (i.e. http://192.168.0.101 )
18- Enter password ( default is 1234 )
19- You can Turn ON / OFF from the user interface.
20- Always start the system with 100% FAN power
21- After one minute, you can decrease the speed of the Fan
22- You can change default password and default WiFi key from the Settings menu
23- Please consult technical service if there is an error signal in the User Interface
Optional:
If you want to access the User Interface from Internet, consult your IP admin to make
a port forwarding.
Example: Forward Port 1101 to my UVCpectra
Now you can access with a browser from your internet using below format:
http://yourcompanyInternetIP.com:1101
or: http://213.244.45.66:1101 (Ip address and port needs to be given by your IP
admin)
Enjoy the clean air.
Informative Lights and meanings:
WiFi LED
Orange Working as an Access Point.
Green Connected to WiFi Network
Blinking green:
Trying to
connect to WiFi
Network
UVC LED
Off UVGI is off
BLUE UVGI is ON
BLUE BLINK Starging UP (20 – 60 seconds)
RED BLINK Error in Fan or Bulbs
Press the UVC button to turn ON/OFF device without user interface
Press and hold WiFi button 10 seconds to RESET wifi settings to Access Point
(factory defaults)

Page | 9
9- Maintanence
UVC Fluorescent light bulbs have 9.000h Useful Life Time.
Please call technical service to change the UVC Bulbs and Reflection system when
9.000 hours is reached.
LIGHT TECHNICAL
Main Application Disinfection
Useful Life (Nom) 9000 h
System Description High Output
Color Code TUV
Depreciation at Useful Lifetime 15%
UV-C Radiation at 100 hr 25 W / bulb
10- Possible Faults and Troubleshooting
Consult an authorised technician if RED Blinking
You can see the error from the user interface.
LIGHTS Meaning Action
RED LIGHT BLINK FAN or Bulb error Goto user interface and see error
If there is a fan error start the unit with 100% fan speed
If fan error continues, call technical center
If there is a bulb error call technical center for replacement
GREEN LIGHT BLINK Cannot access Wifi TURN Off the system with ON /OFF switch
Wait 10 seconds
TURN ON the system
If problem continues, Restart your WiFi access point and try again
If problem continues, RESET WiFi settings to factory defaults.
Press and HOLD WiFi button 10 seconds.
Do the installation again

Page | 10
11- Warranty Clauses
All parts except the bulbs are in 2 years warranty from the purchase date
Bulbs are not in warranty
Add1 – Spare Parts List
Tube 300 Ultra and Standalone 300 Ultra:
UVC Bulb :UVCpFLph75300
Driver 1 (1x80Watt) :UVCpDRos80x1
Driver 2 (2x80 Watts) :UVCpDRos80x2
Fan :UVCpFNruEC1502
EC Board :UVCpEColi201001
Reflection System :UVCpRFvr201022
Stand Alone 300 Ultra Only:
Filter Replacement :UVCpFIvr201031 (set of 3)

Page | 11
Add2 – EU Conformity Declaration

Page | 12
Add3 – Electrical Schema
Button / LED Configurations
This manual suits for next models