The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in
the order specified.
Validity
These installation instructions are valid for the following models:
Product family With normal mounting frame With dual design With oversize frame
31078 GK46TIGC GK46TIGZ -
31083 GK47TIMASC GK47TIMASZ -
31086 GK46TIMSC/O GK46TIMSZ/O GK46TIMSU/O
31087 GK46TIMXSC GK46TIMXSZ -
31090 GK46TIMGC GK46TIMGZ -
31091 GK46TIMASC GK46TIMASZ -
General notes
The directives and standards for low-voltage installations and fire protection must be complied with when installing
in flammable material.
Identification plate
The identification plate is located next to the connec-
tion plate.
Connection plate
Identification plate
▸Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appli-
ance.

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
2
Installation accessories supplied
Oversize mounting frame:
Designation Art. No.
Adjusting brace set H61548
Flush installation:
Designation Art. No.
Cementing-in instructions J004133
Sealing tape set H63283
Spacer set H60330
Accessories
For all installation variants:
Designation Art. No.
Ventilation protective plate set for niche width 550mm H61082
Ventilation protective plate set for niche width 600mm H61083
Ventilation protective plate set for niche width 825mm H61084
Ventilation protective plate set for niche width 900mm H61085
Overlying installation:
Designation Art. No.
Stainless-steel bridge for the overlying combination of various hobs 1014361
Black bridge for the overlying combination of various hobs 1019199
Flush installation:
Designation Art. No.
Steel angle set, installation dimension 60 H63772
Steel angle set, installation dimension 70 H63773
Steel angle set, installation dimension 80 H63774
Instant adhesive for installing the steel angle
Permabond F246 incl. activator, 50ml tube. From Silitech AG, 3008 Bern.
B11502
Sealant set
Complete with cleaning agent, primer type 1105, cartridge with black silicone adhesive, with nozzle.
Suitable for all absorbent covering materials (wood and types of natural stone such as marble and
granite).
86.3928.85
Special primer type 107
Suitable for non-absorbent covering materials (not suitable for polyethylene, polypropylene or Teflon).
45.2771.76
Bridge set for the flush combination of various hobs (comprises two bridges) H63789

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
3
Electrical connection
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications.
An all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches,
plug and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-
poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth con-
ductors ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be ac-
cessible. Check old installations.
▸The appliance is designed for use up to a max. altitude of 2000 m above sea level.
▸Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Installation pipe Distribution boxClamp
brown + black
blue
yellow/green
black
blue
yellow/green
brown
L2
L1
N
N
L1
PE/
PE/
400 V 2N~
230 V~
Error message U400
Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Ventilation
In order to guarantee good ventilation, a space of ≥ 10mm
height is necessary beneath the appliance.
1. The rear panel of the base unit must be open around the
work surface cut-out to guarantee continuous air circula-
tion via the ventilation slits.
The air must be drawn in from outside the cabinet and
be able to circulate freely from inside the cabinet to the
hob.
2. Alternatively, a concealed fresh air supply can ensure air
circulation inside the cabinet.
In order that enough cold air can be drawn in, there
must be a continuous circulation of fresh air that extends
outside the cabinet.
The air must be drawn in from outside the cabinet and
be able to circulate freely from inside the cabinet to the
hob.
≥15
21

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
4
General information about installation
▪The worktop must be flat so that it is sufficiently sealed against the ingress of liquids.
▪In order to guarantee good ventilation, a space of at least 10mm in height is necessary beneath the appliance.
Overlying installation with normal mounting frame
The cooking ring layout of the hob to be fitted can differ from the hob illustrated.
GK46TIGC, GK46TIMGC, GK46TIMSC/O
H
584
514
Y
Y
490 1
560 1
≥50
≥50
A
600/550
≥57**
Ri
Ra
GK46TIMASC, GK47TIMASC
514
H
774
Y
Y
490 1 ≥50
≥50
750 1
600/550
A
1
Ri
Ra
GK46TIMXSC
514
H
704
Y
Y
Ri
490 1 ≥50
≥50
A
680 1
600/550
==
==
1
Ra
≥10*
B
Y – Y
Drawer/cabinet
Cable length 1.7 m Cable length 1.7 m Cable length 1.7 m
* The clearance space must be maintained.
** Cut-out for a niche width of 550mm
1With symmetrical installation, cut-outs in the side panels are not required.
Type A – loosely based on
manufacturer
B H Corner radius Ra/Ri
GK46TIMGC, GK46TIMSC/O,
GK46TIMXSC, GK46TIMASC,
GK47TIMASC, GK46TIGC
≥30mm ≥60mm 50mm 10/8mm
AWorktop depth (in combination with directly built-under oven)
BRequired clearance in the service exchange
HMeasurement from the top side of the worktop to the underside of the hob (ventilation opening)
Ri Appliance corner radii Ra External corner radii of the cut-out
Installation
1. Create the mounting cut-out accurately.
2. Carefully place the appliance in the mounting cut-out and push against the work surface until flat.

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
5
Overlying installation
The cooking ring layout of the hob to be fitted can differ from the hob illustrated.
≥10*
B
Y – Y
Drawer/cabinet
490 1 ≥50
≥50
A
680 1
600/550
==
==
1
Ra
571
501
Y
Y
Ri
H
GK46TIGZ, GK46TIMGZ, GK46TIMSZ/O
Cable length 1.7 m
490 1
560 1
≥50
≥50
A
600/550
Ra
501
Ri
H
691
Y
Y
Cable length 1.7 m
GK46TIMXSZ
490 1 ≥50
≥50
750 1
600/550
A
1
Ra
501
761
Y
Y
Ri
GK46TIMASZ, GK47TIMASZ
Cable length 1.7 m
* The clearance space must be maintained.
1With symmetrical installation, cut-outs in the side panels are not required.
Type A – loosely based on
manufacturer
B H Corner radius Ra/Ri
GK46TIGZ, GK46TIMGZ,
GK46TIMSZ/O, GK46TIMXSZ,
GK46TIMASZ, GK47TIMASZ
≥30mm ≥71mm 47.7mm 5/1.5mm
AWorktop depth (in combination with directly built-under oven)
BRequired clearance in the service exchange
HMeasurement from the top side of the worktop to the underside of the hob (ventilation opening)
Ri Appliance corner radii Ra External corner radii of the cut-out
Installation
1. Create the mounting cut-out accurately.
2. Carefully place the appliance in the mounting cut-out and push against the work surface until flat.

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
6
Flush installation
The cooking ring layout of the hob to be fitted can differ from the hob illustrated.
507±1
577±1
41,5
41,5
A
600/550
571
501
Y
Y
X
X
Ri
Z
H
501
691
Y
Y
A
507±1
41,5
41,5
600/550
Z
697±1
X
X
Ri
H
C
D
Ra
R0–5
8,5
0
-1
8,5
8,5
Detail Z
Steel angle mounted
with adhesive or screws
+1
0
B
10*
600/550
H
X – X
H
10*
Y – Y
B
Drawer/cabinet
Side panel
501
761
Y
Y
507±1 41,5
41,5
767±1
600/550
825/900
A
Z
X
X
Ri
GK46TIGZ, GK46TIMGZ, GK46TIMSZ/O GK46TIMASZ, GK47TIMASZGK46TIMXSZ
Cable length 1.7 mCable length 1.7 mCable length 1.7 m
8,5
+1
0
0
-0,5
1
* The clearance space must be maintained.
1With symmetrical installation, cut-outs in the side panels are not required.
Type A – loosely based on
manufacturer
B C/D H Corner radius Ra/Ri
GK46TIGZ, GK46TIMGZ,
GK46TIMSZ/O
≥30mm ≥75mm 560/490 51.7mm 5/1.5mm
GK46TIMXSZ 680/490
GK46TIMASZ, GK47TIMASZ 750/490
AWorktop depth (in combination with directly built-under oven)
BRequired clearance in the service exchange
HMeasurement from the top side of the worktop to the underside of the hob (ventilation opening)
Ri Appliance corner radii Ra External corner radii of the cut-out

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
7
Installation
1. Create the mounting cut-out accurately.
– The mounting surface can be recessed by installing wood or stone bars or produced using the steel angle set (see Ac-
cessories).
Access to the appliance from below must be guaranteed over the entire cut-out surface. For servicing, the induction gen-
erator with the mounting plate can be removed from below. It must be possible to unscrew the contact-proof covers from
below.
2. Prepare the cut-out and appliance in accordance with the specifications in the enclosed cementing-in instruction.
3. Carefully cement the appliance in place and allow the silicon cement joints to dry for at least 24 hours.
4. Potentially connect to the electrical mains connection before inserting the appliance.
Installation with oversize mounting frame
The cooking ring layout of the hob to be fitted can differ from the hob illustrated.
GK46TIMSU/O
≥10*
B
Y – Y
Drawer/cabinet
490–530
560–585
600/550
=
=
A
H
600
545
Y
Y
Ri
Ra
Cable length 1.7 m
* The clearance space must be maintained.
Type A – loosely based on
manufacturer
B H Corner radius Ra/Ri
GK46TIMSU/O ≥30mm ≥58.2mm 48.2mm 10/8mm
AWorktop depth (in combination with directly built-under oven)
BRequired clearance in the service exchange
HMeasurement from the top side of the worktop to the underside of the hob (ventilation opening)
Ri Appliance corner radii Ra External corner radii of the cut-out
Installation
1. Create the mounting cut-out accurately.
2. Carefully place the appliance in the mounting cut-out and push against the work surface until flat.
The appliances with oversize frames can also be used as an alternative to built-in solid plates and to installation in complete
chrome-nickel steel covers. In the latter case, the built-in solid plate part is cut out of the chrome-nickel steel cover and replaced
by an appliance (depth of the work surface ≥30mm). In contrast to normal installation without a fastening system, the appliance
is fixed from below using adjusting braces.

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
8
Variable areas of the special cut-out dimensions
GK46TIMSU/O
560–585
490–530
==
(30)
6 adjusting braces
Aim for
≤R10
Reinforcement of the cut-outs with a
complete chrome-nickel steel cover
Arrangement of the adjusting braces
≤25
≤32
E D
40
30
(≤ screw length)
(≤ screw length)
Warning, glass breakage:
Do not overtighten screws
Reinforcing slats:
≥25 × 25 mm
Plate for chrome-nickel steel cover
The installation instructions with regard to electrical and safety-related issues remain fully valid for this installation.
1. Make a precise, right-angled cut-out in the work surface (if not already present). Aim to keep the cut-out dimensions to a min-
imum.
2. Securely clamp the appliance in the cut-out using the enclosed adjusting braces D and screws E. If necessary, install reinfor-
cing slats and use these to make the cover flat.

Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
9
Installation of the ventilation protective plate with 3 mm ventilation gap at the front
A ventilation protective plate is required to ensure sufficient ventilation of the hob.
There must be a distance of ≥ 10mm between the underside of the appliance and the ventilation protective
plate.
393
(30)
67.5
5..10
53.5
56
ø4
15
(X) H
3
≤0.5
2.5
Caution: Mains cable must
not touch protective plate!
Well-fitting seal over
width of cabinet element
Air gap over entire width of
cabinet element 17 cm²
According to template
Drawer
Fan
Type X Remarks
GK46TIGC, GK46TIMGC, GK47TIMASC, GK46TIMXSC, GK46TIMASC,
GK47TIAMSC
12mm Overlying installation
GK46TIGZ, GK46TIMGZ, GK46TIMSZ, GK46TIMXSZ, GK46TIMASZ,
GK47TIMASZ
10mm Flush installation
GK46TIMSU 13mm With oversize mounting frame
HDimension from the top of the work surface to the underside of the hob (fan opening).
Cool air supply with regard to drawer or cabinet installed below
To ensure good ventilation, there must be ≥ 10mm of space under the appliance.
≥5
≥15
(30)
600/550
900/825
≥25 cm²
H
B
Drawer Centre of fan
Air gap over the entire cabinet element width A
ARequired space for the appliance under the work surface.
BRequired space for the ventilation of the appliance under the work surface.
HDimension from the top of the work surface to the underside of the hob (fan opening)
This manual suits for next models
15
Other V-ZUG Hob manuals

V-ZUG
V-ZUG GK46TI User manual

V-ZUG
V-ZUG GK21TG User manual

V-ZUG
V-ZUG CookTop V2000 I604 User manual

V-ZUG
V-ZUG GAS311EKBZ User manual

V-ZUG
V-ZUG 85A User manual

V-ZUG
V-ZUG GK45TEBS User manual

V-ZUG
V-ZUG GK46TIGC/U/F User manual

V-ZUG
V-ZUG Toptronic User manual

V-ZUG
V-ZUG CookTop Teppan Yaki I40 User manual

V-ZUG
V-ZUG GK47TIMS User manual

V-ZUG
V-ZUG GK26TIQ User manual

V-ZUG
V-ZUG GK21TTG User manual

V-ZUG
V-ZUG GK46TIAKS User manual

V-ZUG
V-ZUG GK11TIFKZ User manual

V-ZUG
V-ZUG CookTop V4000 I402 User manual

V-ZUG
V-ZUG Home User manual

V-ZUG
V-ZUG GK22 Series User manual

V-ZUG
V-ZUG CookTop V4000 A604 User manual

V-ZUG
V-ZUG CookTop V2000 I604 User manual

V-ZUG
V-ZUG CookTop V4000 I302 User manual