manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. V-ZUG
  6. •
  7. Hob
  8. •
  9. V-ZUG CookTopInduction V4000 CTI4T64 Series User manual

V-ZUG CookTopInduction V4000 CTI4T64 Series User manual

This manual suits for next models

11

Other V-ZUG Hob manuals

V-ZUG GK46TIAKS User manual

V-ZUG

V-ZUG GK46TIAKS User manual

V-ZUG GAS411 Series User manual

V-ZUG

V-ZUG GAS411 Series User manual

V-ZUG GK16TIWSF User manual

V-ZUG

V-ZUG GK16TIWSF User manual

V-ZUG CookTop V4000 I302 User manual

V-ZUG

V-ZUG CookTop V4000 I302 User manual

V-ZUG GK11TG User manual

V-ZUG

V-ZUG GK11TG User manual

V-ZUG GK45TEBS User manual

V-ZUG

V-ZUG GK45TEBS User manual

V-ZUG GAS411GSBZ User manual

V-ZUG

V-ZUG GAS411GSBZ User manual

V-ZUG CookTop Teppan Yaki I40 User manual

V-ZUG

V-ZUG CookTop Teppan Yaki I40 User manual

V-ZUG 31038 Series User manual

V-ZUG

V-ZUG 31038 Series User manual

V-ZUG GKD46TIMASZO User manual

V-ZUG

V-ZUG GKD46TIMASZO User manual

V-ZUG 28 User manual

V-ZUG

V-ZUG 28 User manual

V-ZUG GK16TIYSF User manual

V-ZUG

V-ZUG GK16TIYSF User manual

V-ZUG CookTop V2000 I302 User manual

V-ZUG

V-ZUG CookTop V2000 I302 User manual

V-ZUG GAS321 Series User manual

V-ZUG

V-ZUG GAS321 Series User manual

V-ZUG GK45TEAS User manual

V-ZUG

V-ZUG GK45TEAS User manual

V-ZUG GK51TPG User manual

V-ZUG

V-ZUG GK51TPG User manual

V-ZUG GK45TEBS.1 User manual

V-ZUG

V-ZUG GK45TEBS.1 User manual

V-ZUG MaxiFlex GK46TIMS User manual

V-ZUG

V-ZUG MaxiFlex GK46TIMS User manual

V-ZUG GK22 Series User manual

V-ZUG

V-ZUG GK22 Series User manual

V-ZUG GK46TIGC/U/F User manual

V-ZUG

V-ZUG GK46TIGC/U/F User manual

V-ZUG CookTop V2000 I604 User manual

V-ZUG

V-ZUG CookTop V2000 I604 User manual

V-ZUG CookTop V6000 I904 User manual

V-ZUG

V-ZUG CookTop V6000 I904 User manual

V-ZUG GK37TIMSF User manual

V-ZUG

V-ZUG GK37TIMSF User manual

V-ZUG GAS411 Series User manual

V-ZUG

V-ZUG GAS411 Series User manual

Popular Hob manuals by other brands

PreCise BI-2000T user manual

PreCise

PreCise BI-2000T user manual

AEG HK884400XG user manual

AEG

AEG HK884400XG user manual

KKT KOLBE IFZ772EDF Instruction and installation manual

KKT KOLBE

KKT KOLBE IFZ772EDF Instruction and installation manual

premiere PG4VQ255FTN instruction manual

premiere

premiere PG4VQ255FTN instruction manual

AEG HK614000CB user manual

AEG

AEG HK614000CB user manual

Klarstein 10033282 manual

Klarstein

Klarstein 10033282 manual

Zanussi ZGF 782 CTN Instruction booklet

Zanussi

Zanussi ZGF 782 CTN Instruction booklet

Asko H6 Use and care guide

Asko

Asko H6 Use and care guide

Eurotech ED-C3 02 instruction manual

Eurotech

Eurotech ED-C3 02 instruction manual

IKEA Livsgnista manual

IKEA

IKEA Livsgnista manual

Dacor DTT36M974 user manual

Dacor

Dacor DTT36M974 user manual

AEG HKP75410XB user manual

AEG

AEG HKP75410XB user manual

Siemens EX875KYV1E INFORMATION FOR USE

Siemens

Siemens EX875KYV1E INFORMATION FOR USE

AEG CERAMIC HOB 6010 K Installation and operating instructions

AEG

AEG CERAMIC HOB 6010 K Installation and operating instructions

Zanussi ZGF 6420 Instruction booklet

Zanussi

Zanussi ZGF 6420 Instruction booklet

G3 Ferrari Energy user manual

G3 Ferrari

G3 Ferrari Energy user manual

Award H903BG user manual

Award

Award H903BG user manual

Bosch PIN64 T1 Series instruction manual

Bosch

Bosch PIN64 T1 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
1
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in
the order specified.
Validity
These installation instructions apply to the following models:
Model number With normal mounting frame With DualDesign With oversize mounting frame
31115 CTI4T64MMSLC, CTI4T64MMSOLC CTI4T64MMSLD,
CTI4T64MMSOLD
CTI4T64MMSLU, CTI4T64MMSOLU
31116 CTI4T74MMSLC, CTI4T74MMSOLC CTI4T74MMSLD,
CTI4T74MMSOLD
-
General notes
If installing into a combustible material, the guidelines and standards for low-voltage installations and fire protection
must be strictly observed.
Identification plate
The identification plate is located next to the connection plate.
Connection plate
Identification plate
▸Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appliance.
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
2
Installation accessories supplied
Oversize mounting frame:
Designation Art. no.
Adjusting brace set H61548
Flush installation:
Designation Art. no.
Cementing-in instructions J004133
Sealing strip set H63283
Spacer set H60330
Accessories
For all installation variants:
Designation Art. no.
Ventilation protective plate set for niche width 550mm H61082
Ventilation protective plate set for niche width 600mm H61083
Ventilation protective plate set for niche width 825mm H61084
Ventilation protective plate set for niche width 900mm H61085
Surface-mounted installation:
Designation Art. no.
Stainless steel intermediate support for the surface-mounted combination of several hobs 1014361
Black intermediate support for the surface-mounted combination of several hobs 1019199
Flush installation:
Designation Art. no.
Steel angle set, installation dimension 60 H63772
Steel angle set, installation dimension 70 H63773
Steel angle set, installation dimension 80 H63774
Instant adhesive for installation of the steel angle (50ml) B11657
Straight mixing nozzle B11656
TREMCLEAN isopropyl alcohol (1000ml) 1056609
Black silicone FA880 (310ml) B11555
Anthracite silicone FA880 (310ml) B11556
White silicone FA880 (310ml) 1031313
Stone grey silicone FA880 (310ml) 1031314
Marble smoothing agent AA320 (1000ml) B11557
Fugenboy (silicone finishing tool) B75158
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
3
Electrical connection
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
▸If the hobs are used at an altitude of over 2,000 meters above sea level, a reduced performance must be expected.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Installation pipe Distribution boxClamp
brown + black
blue
yellow/green
black
blue
yellow/green
brown
L2
L1
N
N
L1
PE/
PE/
400 V 2N~
230 V~
Error message U400
Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Ventilation
In order to guarantee good ventilation, a space of ≥10mm
height is necessary beneath the appliance.
1. The rear panel of the base unit must be open around the
work surface cut-out to guarantee continuous air circula-
tion via the ventilation slits.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.
2. Alternatively, a concealed fresh air supply can ensure air
circulation inside the cabinet.
In order that enough cold air can be drawn in, there must
be a continuous circulation of fresh air that extends outside
the cabinet.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.
≥15
21
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
4
General information about installation
▪The worktop must be flat so that it is sufficiently sealed against the ingress of liquids.
▪In order to guarantee good ventilation, a space of at least 10mm in height is necessary beneath the appliance.
Overlying installation with normal mounting frame
The layout of the hob to be fitted may differ from the hob illustrated!
H
584
514
Y
Y
490 1
560 1
≥50
≥50
A
550/600
≥57**
Ri
Ra
≥10 *
B
Y – Y
H
Drawer/cabinet
514
H
704
Y
Y
Ri
490 1 ≥50
≥50
A
680 1
550/600
==
==
Ra
CTI4T74MMSLC,
CTI4T74MMSOLC
CTI4T64MMSLC,
CTI4T64MMSOLC
Cable length 1.7 mCable length 1.7 m
* The required clearance must be observed!
** Cut out if niche width 550mm
Type A Depends on producer B H Corner radius Ra/Ri
CTI4T64MMSLC, CTI4T64MMSOLC,
CTI4T74MMSLC, CTI4T74MMSOLC
≥20mm ≥60mm 50mm 10/8mm
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for ventilation and service replacement over the entire cut-out area.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
1. Create the mounting cut-out accurately.
2. Carefully place the appliance in the mounting cut-out and push against the work surface until flat.
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
5
Overlying installation
The layout of the hob to be fitted may differ from the hob illustrated!
490±1 50
50
A
680±1
550/600
==
==
Ra
571
501
Y
Y
Ri
H
490±1
560±1
50
50
A
550/600
Ra
501
Ri
H
691
Y
Y
10 *
B
Y – Y
H
Drawer/cabinet
CTI4T74MMSLD,
CTI4T74MMSOLD
CTI4T64MMSLD,
CTI4T64MMSOLD
Cable length 1.7 mCable length 1.7 m
* The required clearance must be observed!
Type A Depends on producer B H Corner radius Ra/Ri
CTI4T64MMSLD, CTI4T64MMSOLD,
CTI4T74MMSLD, CTI4T74MMSOLD
≥20mm ≥60mm 50mm 5/1.5mm
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for ventilation and service replacement over the entire cut-out area.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
1. Create the mounting cut-out accurately.
2. Carefully place the appliance in the mounting cut-out and push against the work surface until flat.
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
6
Flush installation
The layout of the hob to be fitted may differ from the hob illustrated!
507±1
577±1
41.5
41.5
A
550/600
571
501
Y
Y
X
X
Ri
Z
H
501
691
Y
Y
A
507±1
41.5
41.5
550/600
Z
697±1
X
X
Ri
H
CTI4T64MMSLD,
CTI4T64MMSOLD
CTI4T74MMSLD,
CTI4T74MMSOLD
Cable length 1.7 mCable length 1.7 m
H
10 *
Y – Y
B
Drawer/cabinet
Side panel
B
H
10 *
X – X
550/600
C
D
Ra
R0–5
8.5
0
-1
8.5
0
-0.5
8.5 8.5
+1
0
+1
0
Detail Z
Steel angle mounted
with adhesive or screws
* The required clearance for ventilation must be observed!
Type A Depends on producer B C/D H Corner radius Ra/Ri
CTI4T64MMSLD, CTI4T64MMSOLD ≥20mm ≥75mm 560/490 51.7mm 5/1.5mm
CTI4T74MMSLD, CTI4T74MMSOLD 680/490
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for ventilation and service replacement over the entire cut-out area.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
1. Create an accurate installation cut-out.
– The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Accessor-
ies).
Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the induction gen-
erator can be removed from below with the mounting plate. It must be possible to unscrew the contact-proof covers from be-
low.
2. Prepare the cut-out and appliance in accordance with the specifications in the enclosed cementing-in instructions.
3. Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.
4. Connect to the electrical mains connection before inserting the appliance, if necessary.
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
7
Installation with oversize mounting frame
The layout of the hob to be fitted may differ from the hob illustrated!
490–530
560–585
550/600
=
=
A
H
600
545
Ri
Ra
Y
Y
10 *
B
Y – Y
H
Drawer/cabinet
CTI4T64MMSLU, CTI4T64MMSOLU
Cable length 1.7 m
* The required clearance must be observed!
Type A Depends on producer B H Corner radius Ra/Ri
CTI4T64MMSLU, CTI4T64MMSOLU ≥20mm ≥58.2mm 48.2mm 10/8mm
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for ventilation and service replacement over the entire cut-out area.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
The appliances with oversize frames can also be used as a replacement for solid plate hobs and for installation in complete chrome-
nickel steel covers. In the latter case, the solid plate hob part is cut out of the chrome-nickel steel cover and replaced by an appliance
(depth of the work surface ≥30mm). In contrast to normal installation without a fastening system, the appliance is fixed from below us-
ing adjusting braces.
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
8
Variable areas of the special cut-out dimensions
CTI4T64MMSLU, CTI4T64MMSOLU
560–585
490–530
==
(30)
6 adjusting braces
Aim for
≤R10
Reinforcement of the cut-outs with
a complete chrome-nickel steel cover
Arrangement of the adjusting braces
≤25
≤32
E D
40
30
(≤ screw length)
(≤ screw length)
Warning, glass breakage:
Do not overtighten screws
Reinforcing slats:
≥25 × 25 mm
Plate for chrome-nickel steel cover
The installation instructions with regard to electrical and safety-related issues remain fully valid for this installation.
1. Make a precise, right-angled cut-out in the work surface (if not already present). Aim to keep the cut-out dimensions to a minimum.
2. Securely clamp the appliance in the cut-out using the enclosed adjusting braces D and screws E. If necessary, install reinforcing
slats and use these to make the cover flat.
Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
9
Installation of the ventilation protective plate with 3 mm ventilation gap at the front
A protective plate is necessary for the adequate ventilation of the hob.
The distance between the underside of the appliance and the protective plate must be ≥10mm.
393
(30)
67.5
5..10
53.5
56
ø4
15
(X) H
3
≤0.5
2.5
Caution: Mains cable must
not touch protective plate!
Well-fitting seal over
width of cabinet element
Air gap over entire width of
cabinet element 17 cm²
According to template
Drawer
Fan
Type X Remarks
CTI4T64MMSLC, CTI4T64MMSOLC, CTI4T74MMSLC, CTI4T74MMSOLC 12mm Normal mounting frame
CTI4T64MMSLD, CTI4T64MMSOLD, CTI4T74MMSLD, CTI4T74MMSOLD 12mm Surface-mounted installation
CTI4T64MMSLD, CTI4T64MMSOLD, CTI4T74MMSLD, CTI4T74MMSOLD 10mm Flush installation
CTI4T64MMSLU, CTI4T64MMSOLU 13mm With oversize mounting frame
HDimension from the top of the work surface to the underside of the hob (ventilation opening).
Cool air supply with regard to drawer or cabinet installed below
In order to guarantee good ventilation, a space of ≥ 10mm height is necessary beneath the appliance.
≥5
≥15
(30)
550/600
825/900
H
B
Drawer Centre of fan
≥25 cm²
Air gap over the entire cabinet element width A
ANecessary space below the worktop for the appliance.
BNecessary space below the worktop for the ventilation of the appliance.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)