
Technical Brief: Vacuum System Design:
Choosing The Correct Sized Tubing
Technical Brief: How Vacuum Pumps Work
Operating Instructions: VP 00-10-20-80-90 Series Modular Vacuum Pumps – 2
© 2014 Vaccon Company
The recommended tubing sizes are based on polyethylene or polyurethane tubing with 0.062” [/”, 1.5 mm] wall thickness
Note: Vaccon discourages the use of quick disconnect fings on all connecons
VP00
VP20/80/90
VP10
End Views:
Air Supply
Ports
Top Views:
Vacuum
Ports
Operating / Installation Instructions: VP 00-10-20-80-90
Modular Venturi Vacuum Pump Series
Addional Informaon
VP Series
Model
Air Supply Port
Threads
Recommended
Air Supply Line
(outer diameter)
Vacuum Port
Threads
Recommended
Vacuum Line
(outer diameter)
VP00-60 (M,H) Series 10-32 UNC Female ¼" [6 mm] 10-32 UNC Female ¼" [6 mm]
VP10-(60,90) (L,M,H) Series ¼ NPT ¼" [6 mm] ⅛ NPT ¼" [6 mm]
VP10-(100,150) (L,M,H) Series ¼ NPT ⅜" [10 mm] ⅛ NPT ⅜" [10 mm]
VP20-(60,90) (L,M,H) Series ¼ NPT ¼" [6 mm] ¼ NPT ¼" [6 mm]
VP20-(100,150) (L,M,H) Series ¼ NPT ⅜" [10 mm] ¼ NPT ⅜" [10 mm]
VP80-200 (L,M,H) Series ¼ NPT ⅜" [10 mm] ⅜ NPT ⅜" [10 mm]
VP80-250 (L,M,H) Series ¼ NPT ⅜" [10 mm] ⅜ NPT ½" [12 mm]
VP90-300 (L,M,H) Series ⅜ NPT ½" [12 mm] ½ NPT ½" [12 mm]
VP90-350 (L,M,H) Series ⅜ NPT ½" [12 mm] ½ NPT ½" [12 mm]