Rev. 1.2
7.Control with External Signals
CAUTION
Use output signal cable of 3m or shorter.
Do not apply too high current and voltage.
Do not use external connector except SELV circuit with reinforced insulation or
a circuit with double insulation.
Connector Communications Specifications
No. Signal
1 Tx
2 Rx
3 NC
4 GND
Command Formats
Channel Specification
Channel CH1 CH2 CH3 CH4
Set Value 00 01 02 03
Lighting Mode Setting
40μS 80μS 120μS 200μS 600μS 1.2mS 4mS 10mS 20mS 40mS
Channel F01 F02 F03 F04 F05 F06 F07 F08 F09 F10
Set Value 01 02 03 04 05 06 07 08 09 10
Sta tus Strobe Mode
Receive Data
Light Intensity Setting
Lighting Mode Setting
ON/OFF Setting
Function Header Channel specification
@
00 to 03
(Refer toChannel
Specification)
FF: All channels
(ON/OFF setting only)
O N
NG
01: Command Error
02: Checksum Error
03: Setvalue out of Range Error
Receive Command
OK
-----
ID
specification
00 (Fixed)
Checksum
Checksum)
<CR><LF>
Delimiter
Channel Specification
Channel CH1 CH2 CH3 CH4
Set Value 00 01 02 03
Checksum
Header Channel
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
Character @ 0 1 F 1 2 5 0 0
ASCII (hexadecimal) 40 hex 30 hex 31 hex 46 hex 31 hex 32 hex 35 hex 30 hex 30 hex 1DF hex
*Set value that are higher than 10 are not valid.
The codes of the ASCII characters
from the header to the ID are
added,
the lowest byte is converted to
hexadecimal, and two characters are
sent.
Example: Setting t he Light Intensity of Channel 2 to 125
Sent command ID Total
Send Data (*1)
Instruction Data (*2)
Light Intensity Setting F 000 to 255 (000:Min. Intensity, 255:Max. Intensity) 000
Lighting Mode Setting S 01 to 10 (Refer to Lighting Mode Settings) 00
ON/OFF Setting (*3) L 0 : Not Lit , 1 : Lit (*4) ----- (*5)
*1: Send a data within 4 seconds from 'Header' to 'Delimiter', otherwise time-out error occurs and command data will be rejected.
*2: Specify all numbers in Decimal format.
*3: ON/OFF settings from EIA-232-D communications without regards to trigger logic switch, turned OFF at '0' and ON at '1'. ON/OFF setting will not be held after turning
the power off.
*4: When operating EIA-232-D Communications and trigger signal input at same time in ON/OFF mode.
When Trigger H/L logic switach is at H : if either controls setting to OFF setting, Light unit will be turned OFF.
When Trigger H/L logic switach is at L : if either controls setting to ON setting, Light unit will be turned ON.
*5: Defalt setting for trigger logic switch is H ='1(ON)' and L='0(OFF)'.
Sent command
@
Function Header Channel specification
00 to 03
(Refer toChannel
Specification)
FF: All channels
(ON/OFF setting only)
Default
00 (Fixed)
ID
specification Checksum Delimiter
00 to FF
(Refer to
Checksum)
<CR><LF>
Communications protocol EIA-232-D
Baud rate 38,400 bps
Data bit length 8 bits
Parity bit None
Stop bits 1 bit