Restorator®
IMPORTANT
Thank you for purchasing the Restorator® by Vaportek. The unit
is an easy-to-use, portable system. It treats areas up to
20,000 ft3 to effectively eliminate odor contamination quickly
and safely. The unit is primarily intended for delivering a fast,
high-intensity odor neutralizing treatment. A characteristic
neutralizer fragrance will be noticeable during operation as the
essential oil dry vapor circulates throughout the treatment area.
Residual fragrance will dissipate in a matter of hours after
treatment ends. With proper care, your Restorator will provide
you years of trouble-free service. Please read these use and
operating instructions carefully before operating your new
machine and keep it for future reference.
Ensure unit is plugged into the correct outlet. Situate unit so air
flow at both ends is unobstructed, preferably in a relatively high
location. Place on a firm, stable surface. Ensure cartridge is
properly installed with the plastic cap removed from the cartridge
prior to installation. To preserve cartridge life, always store with
the cap on when not in use. Turn the unit on, moving it to different
areas if appropriate. Deodorization may require as little as 15-60
minutes for light contamination. For more severe contamination,
treatment may take several hours or days.
THANK YOU INSTRUCTIONS
Insert open end of
cartridge into back of
machine, seating firmly
against internal gasket. If
substantial oil leakage is
evident, do not use.
Fig. 1 Fig. 2
Fig. 3 Fig. 4
Retain lid for storage by
placing against back of
cartridge.
Install spring-loaded
cover plate against
cartridge lid & twist to
lock into place.
To operate, plug cord
into power outlet.
Always unplug
Restorator before
removing cartridge. The
cord can be coiled for
storage in the back of
the rear cover plate.
Fig. 5
SMOKE/FLOOD DAMAGE
Close outside windows and doors. Open interior doors and expose
contaminated areas to neutralizing dry vapor as much as possible.
Let unit run several hours or overnight (may require even longer
treatment depending on severity of odor damage).
CONTENTS RESTORATION
Place unit in a deodorizing chamber, or tent contaminated items,
and allow neutralizing dry vapor to penetrate. Safe for
electronics, leather, elastics, and other valuable or sensitive items.
CONTAMINATED HOTEL ROOMS
Place the Restorator relatively high in the treatment area. Run
unit in closed treatment area for 15-30 minutes (for light malodor)
or 2+ hours (for severe malodor).
ALSO IDEAL FOR:
Real Estate/Foreclosures
Disaster Recovery
Crime Scene/Bioremediation
Athletic Facilities
Vehicle/Boat/RV
Medical Facilities
SUGGESTED USES
As with any powered tool, certain precautions for safe and
efficient use apply. Please follow these rules and
recommendations when using the Restorator:
1. Use Vaportek approved accessories only.
2. The membrane inside the cartridge is sealed. Do not puncture
or open the internal membrane.
3. Do not allow membrane oils to come in contact with finished
surfaces. Finished surfaces may be damaged by direct
contact with oils. The essential oils used in the membrane are
nontoxic. However, if the oils should leak, wash affected
skin, clothes, and/or surfaces with soapy water.
4. For best results, store cartridges in a cool, dry location and
keep away from extreme heat.
5. Replace cartridges after 270 hours of use.
6. Dry vapor output will be affected by humidity, airflow, and
temperature. Ideal dry vapor release occurs at 50-80°F.
Vapor release significantly increases in excess of 90°F.
7. To extend cartridge life, re-cap it when not in use.
8. Do not immerse or use where contact with water may occur.
9. Do not alter the plug or change the electrical wiring.
10. If unit appears to malfunction, unplug or turn it off
immediately. Contact your dealer or Vaportek for service
advice.
11. Vaportek products use natural essential oils. If an allergic
reaction occurs, please discontinue use immediately.
12. To accelerate the dissipation period of the characteristic
Vaportek fragrance, open windows and turn on floor fans.
13. This system provides a safe, effective alternative to ozone. It
is not recommended for use with ozone generating
equipment.
14. Not designed for continuous, long-term operation.
15. Use standard disinfectant wipes to clean water safe surfaces.
Turn off machine. Lift
off cartridge lid &
discard clear film liner.
Cartridge life is rated at
270 hours.