6. Additional Plasma Friendly Targets can be added into the
linx-IR Repeater System by:
(a)runningUTPcableinloopedcongurationfromone
RJ45 socket A on Receiver Module to another zone.
This can be repeated to link up to 7 Targets into the system,
depending on cable lengths and environmental conditions.
(b) using a linx-IR Distribution Hub (RL-IR170) to
allowforsimpledistributiontoupto7Targetsinastar
wiredconguration,dependingoncablelengthsand
environmental conditions.
by
1. Connect the Plasma Friendly Flat IR Target (included) into
Target Input B on Receiver Module (RL-IR505).
2. Connect Receiver Module to Distribution Module (RL-IR305)
using UTP cable plugged into RJ45 connectors A and G
at both ends.
3. Each Receiver Module can select the IR Emitter output port
K on the Distribution Module that it wishes to control. IR
Discrete Selection Switch C on Receiver Module can be
switchedtothe‘ON’positionforeitherDISCRETEA/B/
COMMON or any combination required (including all ON).
These switches correlate to the same IR Emitter Output
PortsKoftheDistributionModule.Factorysettingisset
to ‘COMMON’.
4. Ifrequired,connecteitherSingleorDouble IR Emitter (RL-
IR700/800)totheIREmitterPortEonReceiverModule
forcontroloflocalAVsource.
5. DiscreteIRfacilityspecicallyforusewithres-linxAV
Matrix System.PleaserefertoAVMatrixSysteminstallation
instructionsformoredetails.
INSTALLATION MANUAL
Receiver Module Connection (RL-IR505)
WARRANTY
VcommPtyLtdstatesthatthewarrantthatthecustomercanrelyonisthat
providedbythemanufacturer.Intheeventofanywarrantyclaimplease
contactusandwewillforwardittothemanufacturer.Themanufacturerwill
thendeterminetheextentoftheirliability.Thisexpresslynegates,tothe
extentpossiblebyAustralianlaw,anywarrantyrelianceonVcommPtyLtd.
ABN:99091281524
VcommPtyLtd
www.resi-linx.com
Patented
RL-IR305/RL-IR505
linx-IR Repeater System
resi-linx Discrete IR System
Discrete IR Selection
G RJ45 socket
H Target Input
I 12VDCInput
J IR/PWRLEDs
K IR Emitter ports
®
Local IR Emitter Port
IR Line Out
Additional IR Zones
IR Zone 1
UTP cable
Flat IR Target
RL-IR505
Receiver Module
Remote
Control
RL-IR305
Distribution Module
Remote
Control
To additional IR
zonesifrequired
IR Zone 2
RL-IR505
B
C
E D
I
A
G
F
RL-IR305
A RJ45 sockets
B Target Input
C Discrete IR Selection switch
D IR Line Out
E Local IR Emitter port
F IR/PWRLEDs
KJ
H
®