Velleman CU2200 User manual

CU2200
WIRELESS SMS ALARM MESSENGER
DRAADLOZE SMS-ALARMMELDER
SYSTÈME DE MESSAGERIE D'ALARME SMS SANS FIL
SISTEMA DE ALARMA INALÁMBRICO POR MENSAJES SMS
DRAHTLOSER SMS-ALARM
USER MANUAL 2
GEBRUIKERSHANDLEIDING 13
NOTICE D’EMPLOI 24
MANUAL DEL USUARIO 35
BEDIENUNGSANLEITUNG 46
V3_03

CU2200 v3-03
23.10.2014 ©Velleman nv
2
User manual
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could
harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should
be taken to a specialized company for recycling. This device should be returned to your distributor or
to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying a VELLEMAN product! The CU2200 is equipped with a very reliable Siemens 16 bit MCU and
can be used for numerous applications (except for medical and aerospace applications) such as industrial
equipment or area monitoring, data capturing, home or car security… Please read the manual thoroughly before
bringing this device into service. If the device was damaged in transit, do not install or use it and contact your
dealer.
2. Safety Instructions
Keep the device away from children and unauthorised users.
Risk of electroshock when opening the cover. Touching live wires can cause life-threatening
electroshocks. Do not open the housing yourself. Have the device repaired by qualified personnel.
There are no user-serviceable parts inside the device. Refer to an authorized dealer for service and/or
spare parts.
3. General Guidelines
Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
Dry location use only. Keep this device away form rain, moisture, splashing and dripping
liquids. Never put objects filled with liquid on top.
Keep this device away from dust and extreme temperatures.
Protect this device from shocks and abuse. Avoid brute force when operating the device.
Familiarise yourself with the functions of the device before actually using it.
All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the
device is not covered by the warranty.
Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the
dealer will not accept responsibility for any ensuing defects or problems.
Keep this manual for future reference.
Do not use outside the technical specifications (see §12).
4. Features
8 x alarm inputs (opto-isolated)
1 x relay output
4 x programmable mobile phone numbers for alarm SMS
4 x programmable phone numbers for alarm call
3 alarm alert modes: SMS, phone dial or SMS and phone dial
automatic power supply voltage level check
automatic reporting on low-power voltage level
programmable SMS alarm text message
GSM dual band support
each event sends its own text message
remote arming or disarming
easy installation
functions: text messages, administration, input and output are all programmable through your mobile phone
access control: by password and mobile phone caller ID
advantages
ono mobile phone is needed on-site
ono alarm panel is needed on-site
ono more constant telephone line charges
ono more on-site maintenance
osecure self-contained unit

CU2200 v3-03
23.10.2014 ©Velleman nv
3
5. Overview
OUT1
Relay output jumper
1 2 3
▪▪▪
1-2 short NC
2-3 short NO (default)
POW
7~12VDC power input
GND
ground
AD1, AD2
these inputs are not supported on the CU2200
IN1, IN3, IN4,
IN5, IN6, IN7, IN8
12VDC alarm input, 7~15mA
GND
common ground opto-coupled
IN2+, IN2-
7~12VDC input
OUT1
relay output, max. 1A, 24VDC, 1A, 120VAC, NC/NO (selected by jumper on board)
Alarm Input
12VDC, 7 ~ 15m, Opto-isolated Inputs (1kΩ Input
Resistance)
24VDC, resistor 1 ~ 2,2kΩ should be used in serial
(a) IN1, IN3, IN4, IN5, IN6, IN7, IN8
Alarm Input: DC12V 7 ~ 15mA, GND: Common Ground
(b) IN2+, IN2-
IN2+:DC5 ~ 12V
IN2-: Ground [It must NOT be common to the GND of the
board]
Relay Output
OUT1, OUT2, OUT3:
Max. 1A, 24VDC / 1A, 120VAC
NC/NO (selected by jumper on board)
Note: OUT2 and OUT3 are not available
on CU2200
6. Connection
RS232 pin assignment
9600bps, 8bit, no parity, 1 stop
pin 2 RxD
pin 3 TxD
pin 5 GND

CU2200 v3-03
23.10.2014 ©Velleman nv
4
LED 1 –green status LED
Rapid flashing on/off
GSM module normal operation
Flashing on/off
GSM network connection problem
Reason:
Antenna not connected
No SIM card
Defective SIM card
Defective GSM module
LED 2 –red network LED
On
Normal operation
Flashing on/off
Searching GSM network
Connecting to network
Receiving SMS messages
Sending SMS messages
Phone dialling
Sound Monitoring
The CU2200 automatically picks up any phone call after eight rings. By connecting a microphone to the
CU2200, you will be able to hear all actions in the room.
7. Quick Setup
Press the yellow button so as to eject the card caddy. Insert
the SIM card with the contacts facing down. Press the card
back into the CU2200.
Attention: “asking for PIN code” must be deactivated
on SIM card first, before use with CU2200! (See
instructions of your mobile phone).
Connect the 12VDC power supply and wait until the red LED
turns on and the green LED flashes every few seconds.
Send following SMS message to the CU2200 (from another
mobile phone): PWD:1234,STATUS%.
Your mobile phone will receive an SMS reply within 30
seconds reporting the health status.
NOTE: The SIM card in the CU2200 must be activated by a
provider like a regular SIM card in a mobile phone.
Make sure to activate the caller ID service.
8. PC Setup Software [V7.0]
The unit can be programmed by: (A) SMS command via mobile phone
(B) Software via its built-in RS232 port
First check the hardware version of your device via an SMS from your mobile phone. When the SMS was correct
the device will reply with a text message containing the version; if there was an error you will get the message
‘SMS format is error!’. The SMS command depends on the software version:
Software version V5, V6
Software version V7
Command: PWD:XXXX,CHECKV
[SMS message received]
ex: SD41 V5.1_3_B 2008/01/28
V5 is system version or hardware version
CU2200.
Command: PWD:XXXX,CHECKVR%
[SMS message received]
ex: SD41 V7.1_3_B 2010/01/28
V7 is system version or hardware version
CU2200.
Important notes on used PC Software:
Software can be found on the included CR ROM or on the product page on www.velleman.eu.
Software version SMS_ProX.exe (SMS PRO_V5.0) only works with hardware version 5 of the CU2200.
Software version SM41DPRO.exe (SMS PRO_7.0) works with both hardware versions 6 and 7. It is
recommended to use this version when you have a hardware version 6 or 7 device.
Software version SMSPro_Setup_2.2.13_0927.exe only works with hardware version 7. When running
this software, select “basic” at start-up.
The software is developed for multiple platforms; hence it is possible that some of the shown functions
are not accessible or (fully) supported.
Note: it is not possible to upgrade the hardware version of the CU2200.
Copy the program folder to C:\ ,and run “SM41DPRO.exe” under windows.

CU2200 v3-03
23.10.2014 ©Velleman nv
5
(refer to the numbers on the illustration)
1. Select the COM port of the PC connected to the device.
2. Click [Connect] button to activate the connection between PC and SMS alarm unit.
3. Click [Health Check] or [Parameters 1 or 2(SYSTEM)] to get the internal configuration.
Please refer each setting to the corresponding command described on next pages.
9. Alarm Response Time
The messenger will start the initialization after connection to the power supply. This procedure will take
about 30 seconds.
In case of an alarm, the unit will send an SMS message to the control centre and to 4 pre-programmed
phone numbers. The control centre can be disabled in order for the phone numbers to receive the alarm
10. GSM Network Connectivity
If the GSM network is suddenly inaccessible or disconnected during the SMS sending, the message will
be lost.
When the CU2200 has failed to send the message due to an inaccessible network, the unit will search
for the network and keep sending the SMS when the network has been re-established.
When failing to send SMS messages, the CU2200 will memorize up to 10 messages and send them as
soon as the network is re-established.
11. SMS Command list
a. System setup
New Password Setup
Manual Health Reporting
Serial Number Setup
Control Centre Number & Health Reporting Schedule Setup
Power-Up Message
System Clock Setup
Phone Number Setup
b. alarm setup
Alarm Input Level & Alert Setup
SMS Alarm Message Setup
SMS Message Contents
Commanding the CU2200 to Send SMS Message
Relay Output Control
Relay Output Delay Time
Operating Voltage Low Level Alarm Message
Operating Voltage Low Level Alarm
Arm/Disarm Setup

CU2200 v3-03
23.10.2014 ©Velleman nv
6
c. System Information Report
Default Setting
System Parameters RESET
System Version Check (hardware version CU2200)
Return Message
System Parameters Report
Manual Health Report
Configure the CU2200 through the command text sent from your mobile phone. Upon reception and
processing, the unit will send a confirmation message to your mobile phone. If the command is incorrect,
the unit will reply SMS format is error!
a. System Setup
New Password Setup
Command: PWD:XXXX,NEWPWD:YYYY%
XXXX
Current password
YYYY
New password (4 digits)
Example:
PWD:1234,NEWPWD:2222%
Default password: 1234
New password: 2222
Manual Health Reporting
Command: PWD:XXXX,STATUS%
[SMS message received]
ST:XXX;T:2005/01/28/13:00;V:XXXX;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:X;K5:X;K6:X;K7:X;K8:
X;OUT1:Y;OUT2:Y;OUT3:Y;#
Example:
ST:002;T:2005/01/28/13:00;V:8.15;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:1;K5:1;K6:X;K7:X;K8
:X;OUT1:1;OUT2:1;OUT3:1;#
ST
Unit serial number
XXX
ASCII code
T
Unit internal clock
XXXX
Year/month/day/time
V
Operating voltage
XXXX
K1
Alarm channel 1
K1:0 means closed
K1:1 means open
K1 ~ 8
Alarm channel 1 ~ 8
OUT1
Relay output 1
OUT1:0 means open
OUT1:1 means closed
OUT1 ~ 3
Relay output 1 ~ 3 (outputs 2 and 3 are
displayed but not available)
Serial Number Setup
Command: PWD:XXXX,SN:YYY%
XXXX
Password
YYYY
Serial number (0-999)
Example:
PWD:1234,SN:268%
Password: 1234 (default)
Serial number set into the unit: 268 (default: 000)
Control Centre Number & Health Reporting Schedule Setup
These two values are configured by one single command.
(1) The control centre number is the phone number receiving the periodic report and regular report.
Besides the periodic report on schedule (command 5: power-up message), report of any command will
be sent to this number in addition to the mobile phone number sending the command. Maximum 2
control centres can be defined.
Command: PWD:XXXX,CTRZ:YYYYYYYYYYY,MM#%
XXXX
Password
Z
Control centre number (max. 2 centres)
1 means 1st centre number
2 means 2nd centre number
YYYYYYYYY
Phone number in control centre
MM
Period code of automatic scheduled health report
Example:
PWD:1234,CTR1:123456789,04#%
Password: 1234
Reporting health status every hour (refer to the reference table below)
(2) The periodic health report and any command from another mobile phone will be reported to the
first control centre with number 123456789.

CU2200 v3-03
23.10.2014 ©Velleman nv
7
Reference table for the automatic scheduled health report
00
No automatic report
07
Every 6 hours
01
Every 5 minutes
08
Every 12 hours
02
Every 15 minutes
09
Every day (08h00)
03
Every 30 minutes
10
Every odd day (08h00)
04
Every 1 hour
11
1st, 7th, 14th, 21st, 28th day (08h00)
05
Every 2 hours
12
1st, 15th day (08h00)
06
Every 3 hours
13
1st day of each month (08h00)
The CU2200 automatically reports the unit’s health status on a pre-defined schedule via an SMS
message.
[SMS message received]
ST:XXX;T:2006/10/08/06:15;V:XXXX;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:X;K5:X;K6:X;K7:X;K8:
X;OUT1:1;OUT2:1;OUT3:1;#
ST
Unit serial number
XXX
ASCII code
T
Unit internal clock
XXXX
Year/month/day/time
V
Operating voltage
XXXX
K1
Alarm channel 1
K1:0 means closed
K1:1 means open
K1 ~ 8
Alarm channel 1 ~ 8
OUT1
Relay output 1
OUT1:0 means open
OUT1:1 means closed
OUT1 ~ 3
Relay output 1 ~ 3
Example:
ST:001;T:2005/01/27/12:00;V:8.14;A1:2312;A2:2131;K1:1;K2:0;K3:0;K4:1; O:1#
ST
Unit serial number
001
T
Unit internal clock
Date: 27 Jan 2005, time: 12h00
V
Operating voltage
8.14VDC
K1
Alarm channel 1
1
Open
K2
Alarm channel 2
0
Closed
K3
Alarm channel 3
0
Closed
K4
Alarm channel 4
1
Open
O
Relay output 1
1
On
Power-Up Message
Whenever the unit is powered up, it will automatically send RESTART! to the control centre.
System Clock Setup
Command: PWD:XXXX,TIME:AABBCCDDEE%
XXXX
Password
AABBCCDDEE
Year/month/day/hour/minute
Example:
PWD:1234,TIME:0602031327%
Password: 1234
Clock: 3 Feb 2006, 13h27
Phone Number Setup
Command: PWD:XXXX,ALMNU1:ZZZZZZZZZZZ,2:ZZZZZZZZZZZ,3:ZZZZZZZZZZZ,4:ZZZZZZZZ
ZZZ,5:ZZZZZZZZZZZ,6:ZZZZZZZZZZZ,7:ZZZZZZZZZZZ,8:ZZZZZZZZZZZ#%
XXXX
Password
ZZZZZZZZZZZ
Phone number
Example 1:
PWD:1234,ALMNU1:12345678,2:36925814712,3:159357456,4:951753654,5:741852963,6:45678
9123,7: 369874123,8:125478963#%
Password
1234
When the alarm is triggered, an SMS message is sent to following
numbers:
N° 1
12345678
N° 2
36925814712
N° 3
159357456
N° 4
951753654
N° 5
741852963
N°6
456789123
N°7
369874123
N°8
125478963

CU2200 v3-03
23.10.2014 ©Velleman nv
8
Example 2:
PWD:1234,ALMNU1:NUL,3:NUL#%
Password
1234
With example 1, following numbers have been cancelled:
N° 1
12345678, not made
N° 2
36925814712, retained
N° 3
159357456, not made
N° 4
951753654, retained
b. Alarm Setup
Alarm Input Level & Alert Setup
Command: PWD:XXXX,ALMLEVELR:X,YY,ZZZZBBBB,NNN%
XXXX
Password
R
Alarm channel number
X
0 means disabled
1 means closed triggers alarm
2 means open triggers alarm
3 means both closed and open triggered alarm
YY
00 means alarm not reported to control centre
10 means alarm reported to control centre 1
01 means alarm reported to control centre 2
11 means alarm reported to control centre 1 and 2
ZZZZBBBB
Selection of the alarm phone dial and alarm SMS
0 means no alarm report
1 means SMS only
2 means phone dial only => (Phone dial not available)
3 means SMS first, then phone dial =>(Phone dial not available)
Z
Z
Z
Z
1st
2nd
3rd
4th phone number
B
B
B
B
5th
6th
7th
8th phone number
NNN
Relay output control
0 means no relay output control
1 means relay output triggered by alarm
N
N
N
1st
2nd
3rd relay output
(2nd and 3rd relay output not available)
Example 1:
PWD:1234,ALMLEVEL2:1,01,10000000,100%
Password
1234
Alarm channel 2
Once the input is closed, the alarm will be triggered
Control centre 2 will be reported by SMS
Phone number 1
Phone number 2
Phone number 3
Phone number 4-8
Relay output 1
Relay output 2
Relay output 3
SMS message
No report
No report
No report
Triggered “Close” by alarm
No control (not available)
No control (not available)
SMS Alarm Message Setup
Alarm channel 1 ~ 8
Command: PWD:XXXX,ALMYTEXT:□□□□□□□□□□□□#%
XXXX
Password
Y
Alarm channel number (1 ~ 8)
E
0 Close triggered alarm
1 Open triggered alarm
□□□□□□□□
SMS message (max. 130 characters –no space allowed)
Example:
PWD:1234,ALM4T1XT:Door Contact1 Open#%
Password
1234
Alarm channel 4 is triggered by “Open Contact”, SMS message “Door
Contact 1 Open” is sent to the pre-defined phone numbers.

CU2200 v3-03
23.10.2014 ©Velleman nv
9
SMS Message Contents
Command 8 is used to program the alarm message contents. The CU2200 will reply to the mobile
phone with the programmed message for that alarm channel.
Command: PWD:XXXX,READYTEXT%
XXXX
Password
Y
Alarm channel number (1 ~ 8)
Commanding the CU2200 to Send SMS Message
This command is used to make the CU2200 to send the SMS message for testing purposes.
Command: PWD:XXXX,SENDMSA:XB%
XXXX
Password
A
Phone number (1 ~ 8)
XB
SMS message selection
00: schedule health check status
01:closed triggered alarm channel 1, SMS message
02: closed triggered alarm channel 2, SMS message
03: closed triggered alarm channel 3, SMS message
04: closed triggered alarm channel 4, SMS message
05: closed triggered alarm channel 5, SMS message
06: closed triggered alarm channel 6, SMS message
07: closed triggered alarm channel 7, SMS message
08: closed triggered alarm channel 8, SMS message
09:manual input message
10:Low voltage alarm message
11:AD channel 1, SMS message
12:AD channel 2, SMS message
13:Open triggered alarm channel 1, SMS message
14: Open triggered alarm channel 2, SMS message
15: Open triggered alarm channel 3, SMS message
16: Open triggered alarm channel 4, SMS message
17: Open triggered alarm channel 5, SMS message
18: Open triggered alarm channel 6, SMS message
19: Open triggered alarm channel 7, SMS message
20: Open triggered alarm channel 8, SMS message
Example:
PWD:1234,SENDMS4:09,Good Morning%
Password
1234
SMS message “Good Morning” will be sent to phone number 4.
Error message about setting A:
Number Choice Miss A is not within 1 ~ 8
Number Non Exist No phone number is preset in that location
Error message about setting XB
Did not specify SMS contents XB is not within 00 ~20
Reply confirmation message:
Success!: CU2200 succeeds in sending message.
Failed!: Operation failed but phone number exists.
Relay Output Control
Command: PWD:XXXX,COUTN:Y%
Password
1234
N
Relay output channel (1 ~ 3) (outputs 2 and 3 not available)
Y
1
0
Turn on (close) the output
Turn off (open) the output
The relay output is N.O. by default.
Command COUTN:1 is not valid when the relay output is triggered by alarm. Reply message will be
ST:XXX in this case.
In the above case, command COUTN:0 is used to reset the relay output after the alarm is triggered.
Relay Output Delay Time
Command: PWD:XXXX,OUTNDLAY:YYYY%
XXXX
Password
N
Relay output channel (1 ~ 3) (outputs 2 and 3 not available)
YYYY
0000 –9999 seconds
0000 Turn the output on or off (default)
0005 Turn on the output for 5 seconds and off again
Turn off the output for 5 seconds and on again
The relay output delay time is good for controlling e.g. an electric door lock.

CU2200 v3-03
23.10.2014 ©Velleman nv
10
Operating Voltage Low Level Alarm Message
When the power supply voltage level is below the minimum level at 5.34VDC, the CU2200 will send
an alarm SMS message.
Date
2007-06-15
Time
13:25
ST:001;TM200706121325;V:5.34#
Operating Voltage Low Level Alarm
This command is used to set the action to be taken once the operating voltage drops below 7.0VDC.
Value of the current operating voltage can be retrieved by command 2.
Command: PWD:XXXX,ADCOUT0:YY,ZZZZBBBB,NNN%
XXXX
Password
YY
00 means alarm not reported to control centre
10 means alarm reported to control centre 1
01 means alarm reported to control centre 2
11 means alarm reported to control centre 1 and 2
ZZZZBBBB
Selection of the alarm phone dial and alarm SMS
0 means no alarm report
1 means SMS only
2 means phone dial only => (Phone dial not available)
3 means SMS first, then phone dial =>(Phone dial not available)
Z
Z
Z
Z
1st
2nd
3rd
4th phone number
B
B
B
B
5th
6th
7th
8th phone number
NNN
Relay output control
0 means no relay output control
1 means relay output triggered by alarm
N
N
N
1st
2nd
3rd relay output
(2nd and 3rd relay output not available)
Arm/Disarm Setup
Command: PWD:XXXX,ARM%
XXXX
Password
Example:
PWD:1234,ARM%
Password
1234
Unit is armed and in alert status
Command: PWD:XXXX,DISARM%
XXXX
Password
Example:
PWD:1234,DISARM%
Password
1234
Unit is disarmed and no alarm is reported
c. System Information Report
Default Setting
Command: PWD:1234,PARAMETER1%
ST:000;T:2006/10/01/01:01;H:1;F1:,00;F2;,00;XH:31#
Command: PWD:1234,PARAMETER2%
ST:000;VL:7.00,O:00,0000,000;A1M:5.000,0.000,1.000,0,5.000,0.500,O:00,00000000,000;A2M:
5.000,0.000,1.000,0,5.000,0.000,O:00,00000000,000#
Command: PWD:1234,PARAMETER3%
ST:000;K1:1,O:00,00000000,000;K2:1,O:00,00000000,000;K3:1,O:00,00000000,000;K4:1,O:00,
00000000,000;K5:1,O:00,00000000,000;K6:1,O:00,00000000,000;K7:1,O:00,00000000,000;K8:
1,O:00,00000000,000#
Command: PWD:1234,PARAMETER4%
ST:000;C1:,1;C2:,1;C3:,1;C4:,1;C5:,1;C6:,1;C7:,1;C8:,1;#
System Parameters RESET
Command: PWD:XXXX,PARAMETER&%
[SMS message received]
Parameter initialize success!

CU2200 v3-03
23.10.2014 ©Velleman nv
11
System Version Check (hardware version CU2200)
Software version V6
Software version V7
Command: PWD:XXXX,CHECKV
[SMS message received]
ex: SD41 V5.1_3_B 2008/01/28
V5 is system version or hardware version
CU2200.
Command: PWD:XXXX,CHECKVR%
[SMS message received]
ex: SD41 V7.1_3_B 2010/01/28
V7 is system version or hardware version
CU2200.
Return Message
Command succeeds
SMS message: Function Code & Setting Parameters Set in the command
Command fails
SMS message: SMS Format is error!
System Parameters Report
Command: PWD:XXXX,PARAMETER1%
[SMS message received]
ST:XXX;T:2006/10/08/08:00;H:X;F1:XXXXXXXXXXX,YY;F2:XXXXXXXXXXX,YY;XH:RR;ER:xyz#
ST:
Unit serial number
T:
Date/time
H:X
Arm/disarm
F1
1st control centre number
XXXXXXXXXX
Control centre number
YY
Automatic health report schedule
XH:RR
GSM network signal strength (1 ~ 40)
ER:xyz
Normal
Defect
GSM Module
x
0
1
SIM Card/Service
y
0
1
GSM Network Coverage
z
0
1
Command: PWD:XXXX,PARAMETER2%
About the alarm channel
[SMS message received]
ST:XXX;VL:XXXXX,O:AX,BBBBBBBB,CCC:A1M:XXXXX,UUUUU,YYYYY,R,HHHHH,PPPPP,O:AX,BBBBB
BBB,CCC;A2M:XXXXX,UUUUU,YYYYY,R,HHHHH,PPPPP,O:AX,BBBBBBBB,CCC;#
VL
Min. operating voltage (7VDC by default), alarm will be triggered if
voltage drops below this level
A
Alarm report to control centre 1
0 means no report
1 means report
X
Alarm report to control centre 2
0 means no report
1 means report
BBBBBBBB
Report status for 8 phone numbers
0 means no report
1 means SMS but no phone dial
2 means phone dial but no SMS
3 means SMS first and then phone dial
CCC
Relay output control
0 means control not triggered by alarm
1 means alarm triggered control
Command: PWD:XXXX,PARAMETER3%
About the alarm 1 ~ 8 status
[SMS message received]
ST:XXX;K1:N,O:AX,BBBBBBBB,CCC;K2:N,O:AX,BBBBBBBB,CCC;K3:N,O:AX,BBBBBBBB,CCC;K4:N,
O:AX,BBBBBBBBB,CCC;K5:N,O:AX,BBBBBBBB,CCC;K6:N,O:AX,BBBBBBBB,CCC;K7:N,O:AX,BBBBB
BBB,CCC;K8:N,O:AX,BBBBBBBB,CCC;OTY:0000,0000,0000;#
K1
Alarm channel 1
N
0 means disabled
1 means closed triggered alarm
2 means open triggered alarm
3 means both closed and open triggered alarm
O
Corresponding output relay status
A
Alarm report to control centre 1
0 means no report
1 means report

CU2200 v3-03
23.10.2014 ©Velleman nv
12
X
Alarm report to control centre 2
0 means no report
1 means report
BBBBBBBB
Report status for 8 phone numbers
0 means no report
1 means SMS but no phone dial
2 means phone dial but no SMS
3 means SMS first and then phone dial
CCC
Relay output control
0 means control not triggered by alarm
1 means alarm triggered control
OTY
0000
1st relay time lapse
0000
2nd relay time lapse
0000
3rd relay time lapse
Command: PWD:XXXX,PARAMETER4%
[SMS message received]
ST:XXX;C1:XXXXXXXX,Y;C2:XXXXXXXX,Y;C3:XXXXXXXX,Y;C4:XXXXXXXX,Y;C5:XXXXXXXX,Y;C6:X
XXXXXXX,Y;C7:XXXXXXXX,Y;C8:XXXXXXXX,Y;#
C1 ~ C8
1st ~ 8th Alarm Phone Number
Y
Alarm Report enabled (1) / disabled (0)
Manual Health Report
Command: PWD:XXXX,STATUS%
[SMS message received]
ST:XXX;T:2005/01/28/13:00;V:XXXX;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:X;K5:X;K6:X;K7:X;K
8:X;OUT1:Y;OUT2:Y;OUT3:Y;#
12. Technical specifications
Electrical
Power Supply
7 ~ 12VDC
Current
500mA (SMS send/receive), 50mA (standby)
Peak Pulse Current
< 2A
RS232
9 000 bps, 8 stop bits, 1 parity bit
Antenna
GSM900
RF Frequency
925 ~ 960MHz
TX Frequency
880 ~ 912MHz
RF Rating
2W, 12.5% loop loading
GSM1800
RF Frequency
1805 ~ 1880MHz
TX Frequency
1710 ~ 1785MHz
RF Rating
1W, 12.5% loop loading
Dimensions
135 x 105 x 30mm
Total Weight
480g
Loading Resistance
50Ω
Radiation S/N
0 dBi
working temperature
-20°C ~ +50°C
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product and the latest version of this user manual, please visit our
website www.velleman.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.

CU2200 v3-03
23.10.2014 ©Velleman nv
13
Gebruikershandleiding
1. Inleiding
Aan alle ingezetenen van de Europese Unie
Belangrijke milieu-informatie betreffende dit product
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt
weggeworpen, dit toestel schade kan toebrengen aan het milieu. Gooi dit toestel (en eventuele
batterijen) niet bij het gewone huishoudelijke afval; het moet bij een gespecialiseerd bedrijf
terechtkomen voor recyclage. U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt
brengen. Respecteer de plaatselijke milieuwetgeving.
Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
Dank u voor uw aankoop! De CU2200 is uitgerust met een uiterst betrouwbare Siemens 16-bit microcontroller
en is geschikt voor tal van toepassingen (uitgezonderd voor medische apparaten en ruimtevaarttoepassingen)
zoals monitoring van industriële machines of ruimtes, dataontvangst, beveiliging van huis en voertuig… Lees deze
handleiding grondig voor u het toestel in gebruik neemt. Werd het toestel beschadigd tijdens het transport,
installeer het dan niet en raadpleeg uw dealer.
2. Veiligheidsinstructies
Houd buiten het bereik van kinderen en onbevoegden.
Elektrocutiegevaar bij het openen van het toestel. Raak geen kabels aan die onder stroom staan
om dodelijke elektroshocks te vermijden. Open de behuizing niet zelf en laat reparaties over aan
geschoold personeel.
Er zijn geen door de gebruiker vervangbare onderdelen in dit toestel. Voor onderhoud of
reserveonderdelen, contacteer uw dealer.
3. Algemene richtlijnen
Raadpleeg de Velleman®service- en kwaliteitsgarantie achteraan deze handleiding.
Enkel te gebruiken op droge plaatsen. Bescherm tegen regen, vochtigheid en opspattende
vloeistoffen.
Bescherm tegen stof en extreme temperaturen.
Bescherm tegen schokken. Vermijd brute kracht tijdens de bediening.
Leer eerst de functies van het toestel kennen voor u het gaat gebruiken.
Om veiligheidsredenen mag u geen wijzigingen aanbrengen. Schade door wijzigingen die de gebruiker heeft
aangebracht valt niet onder de garantie.
Gebruik het toestel enkel waarvoor het gemaakt is. Bij onoordeelkundig gebruik vervalt de garantie.
De garantie geldt niet voor schade door het negeren van bepaalde richtlijnen in deze handleiding en uw
dealer zal de verantwoordelijkheid afwijzen voor defecten of problemen die hier rechtstreeks verband mee
houden.
Bewaar deze handleiding voor verdere raadpleging.
Overschrijd nooit de waarden vermeld in de technische specificaties (zie: §12).
4. Eigenschappen
8 x alarmingangen (met optocoupler)
1 x relaisuitgang
4 x programmeerbare telefoonnummers voor alarm-sms
4 x programmeerbare telefoonnummers voor alarmoproep
3 alarmmodi: sms, telefoonoproep of telefoonoproep met sms
automatische controle van de voedingsspanning
automatische melding bij te lage voedingsspanning
alarm-sms met programmeerbare tekst
ondersteunt gsm met dual band
sms met afzonderlijke tekst voor elke gebeurtenis
in- en uitschakeling op afstand
eenvoudige programmering
functies: tekstberichten, administratie, input en output kunnen via mobile telefoon ingegeven worden
toegang: via paswoord of identiteit van de beller
voordelen
ogeen mobiele telefoon ter plaatse
ogeen alarmpaneel ter plaatse
ogeen hoge telefoonkosten meer
ogeen onderhoud ter plaatse
oveilig en autonoom toestel

CU2200 v3-03
23.10.2014 ©Velleman nv
14
5. Omschrijving
OUT1
Jumper relaisuitgang
1 2 3
▪▪▪
1-2 kortsluiten NC
2-3 kortsluiten NO
(standaard: 2-3)
POW
7~12VDC voedingsingang
GND
aarding
AD1, AD2
niet van toepassing op de CU2200
IN1, IN3, IN4,
IN5, IN6, IN7, IN8
12VDC alarmingang, 7~15mA
GND
gemeenschappelijke aarding optisch geïsoleerd
IN2+, IN2-
7~12VDC ingang
OUT1
relaisuitgang, max. 1A, 24VDC, 1A, 120VAC, NC/NO (geselecteerd door jumper)
Alarmingang
12VDC, 7 ~ 15m, optisch geïsoleerde ingangen (1kΩ
ingangsweerstand)
24VDC, weerstand 1 ~ 2,2kΩ moet in serie gebruikt worden
(a) IN1, IN3, IN4, IN5, IN6, IN7, IN8
Alarm Input: DC12V 7 ~ 15mA, GND: gemeensch.
aarding
(b) IN2+, IN2-
IN2+:DC5 ~ 12V
IN2-: aarding [niet gemeenschappelijk met GND]
Relaisuitgang
OUT1, OUT2, OUT3:
max. 1A, 24VDC / 1A, 120VAC
NC/NO (geselecteerd via jumper)
Opmerking: OUT2 en OUT3 niet
beschikbaar op CU2200
6. Opstelling
RS232 penopstelling
9600bps, 8 bit, geen pariteit, 1 stop
pen 2 RxD
pen 3 TxD
pen 5 GND

CU2200 v3-03
23.10.2014 ©Velleman nv
15
Led 1 –groene statusled
Snel aan-uitknipperen
Normale werking gsm-module
Aan-uitknipperen
Aansluitingsprobleem gsm-module
Reden:
Antenne niet aangesloten
Geen simkaart
Beschadigde simkaart
Beschadigde gsm-module
Led 2 –rode netwerkled
Aan
Normale werking
Aan-uitknipperen
Zoeken naar gsm-netwerk
Aansluiting op gsm-netwerk
Ontvangen van een sms-bericht
Verzenden van een sms-bericht
Telefoonoproep
Bewaking met geluid
De CU2200 antwoordt de oproep automatisch na 8 maal bellen. Sluit een microfoon aan de CU2200 om alle
bewegingen in de ruimte te kunnen horen.
7. Snelle opstelling
Druk op het gele knopje om de kaarthouder uit te werpen.
Steek de simkaart in de houder met de contacten naar de
printplaat toe en sluit de houder.
Waarschuwing: Schakel eerst en vooral de
pincodebeveiliging van de simkaart uit! (zie
gebruikshandleiding van uw gsm).
Sluit een 12VDC-voeding aan. Wacht tot de rode led oplicht
en de groene led knippert.
Stuur volgend sms-bericht naar de CU2200 (vanaf een
andere gsm): PWD:1234,STATUS%.
U ontvangt binnen de 30 seconden een sms dat bericht over
de status op uw mobiele telefoon.
OPMERKING: De simkaart moet door een provider geactiveerd
worden, net zoals de simkaart in uw mobiele telefoon.
Het nummer van het verzonden bericht mag niet
verborgen zijn.
8. Software-instellingen [V7.0]
U kunt de alarmmelder programmeren: (A) via sms-berichten met een gsm
(B) aan de hand van de software via de ingebouwde RS232-poort
Controleer eerst de hardwareversie via een sms-bericht. Bij een correct bericht (zie hieronder) krijgt u een
bericht terug met daarin vermeld de hardwareversie; bij een fout krijgt u het bericht met de melding
SMS format is error! toegestuurd. De inhoud van het bericht hangt af van de softwareversie:
Softwareversie V5, V6
Softwareversie V7
Commando: PWD:XXXX,CHECKV
[Ontvangen sms-bericht]
Voorbeeld: SD41 V5.1_3_B 2008/01/28
V5 = systeemversie of hardwareversie CU2200.
Commando: PWD:XXXX,CHECKVR%
[Ontvangen sms-bericht]
Voorbeeld: SD41 V7.1_3_B 2010/01/28
V7 = systeemversie of hardwareversie CU2200.
Belangrijke opmerkingen over de gebruikte software:
U vindt de nodige software op de meegeleverde cd-rom of op webpagina www.velleman.eu.
Softwareversie SMS_ProX.exe (SMS PRO_V5.0) werkt enkel met hardwareversie 5 of de CU2200.
Softwareversie SM41DPRO.exe (SMS PRO_7.0) werkt met hardwareversies 6 en 7. Het is aan te raden
om deze versie te gebruiken indien uw alarmmelder over hardwareversie 6 of 7 beschikt.
Softwareversie SMSPro_Setup_2.2.13_0927.exe werkt enkel met hardwareversie 7. Selecteer in dit geval
de basisinstellingen.
De software is compatibel met verschillende platformen. De afbeeldingen in deze handleiding kunnen
verschillen van de werkelijke interface.
Opmerking: De hardwareversie van de CU2200 is niet upgradebaar.
Kopieer de programmamap naar C:\ en gebruik SM41DPRO.exe onder Windows.

CU2200 v3-03
23.10.2014 ©Velleman nv
16
(raadpleeg de afbeelding)
1. Selecteer de COM-poort van de aangesloten pc.
2. Klik op [Connect] om de aansluiting tussen de pc en de alarmmelder vast te leggen.
3. Klik op [Health Check] of [Parameters 1 or 2(SYSTEM)] om de interne configuratie weer te geven.
Raadpleeg de volgende pagina’s voor meer uitleg over de commando’s.
9. Responstijd alarm
De alarmmelder start de initialisatie op nadat u hem aan de voeding hebt aangesloten. Deze procedure neemt
ongeveer 30 seconden in beslag.
Wordt het alarm ingeschakeld, dan zendt de alarmmelder een sms-bericht naar een controlecentrum en naar 4
voorgeprogrammeerde telefoonnummers. Het controlecentrum kan uitgeschakeld worden zodat het sms-bericht
de geprogrammeerde telefoonnummers vroeger kan bereiken.
10. Aansluiting op het gsm-netwerk
Is het gsm-netwerk plotseling onbereikbaar of terwijl het sms-bericht wordt verzonden, dan zal dit bericht
onherroepelijk verloren gaan.
Heeft de CU2200 het sms-bericht niet kunnen zenden doordat het netwerk onbereikbaar is, dan zal de
alarmmelder het bericht blijven sturen to het netwerk opnieuw hersteld is.
Heeft de CU2200 het sms-bericht niet kunnen zenden, dan zal de CU2200 tot 10 niet-verzonden berichten
opslaan en ze verzenden van zodra het netwerk is hersteld.
11. Lijst met sms-opdrachten
a. Instellen van het systeem
Instellen van een nieuw paswoord
Manueel statusrapport
Instellen van het serienummer
Instellen nummer controlecentrum & statusrapport
Bericht bij het opstarten
Instellen interne klok
Instellen van de telefoonnummers
b. Instellen van het alarm
Instellen van de alarmingang & waarschuwingsniveau
Instellen van het sms-bericht
Inhoud van het sms-bericht
De CU2200 verplichten een sms-bericht te sturen
Relaisuitgang
Vertraging relaisuitgang
Alarmbericht bij lage voedingsspanning
Voedingsspanning laag alarm
In-/uitschakelen

CU2200 v3-03
23.10.2014 ©Velleman nv
17
c. Rapport systeeminformatie
Standaardinstelling
Resetten van de parameters
Controleren van de systeemversie (hardwareversie CU2200)
Antwoordbericht
Rapport systeemparameters
Manueel statusrapport
Programmeer de CU2200 via de commando’s verzonden vanaf uw gsm-toestel. Nadat de alarmmelder het
bericht heeft ontvangen, zal hij op zijn beurt een bevestigingsbericht naar het gsm-toestel zenden. De
alarmmelder antwoordt met SMS format is error! wanneer het commando ongeldig is.
a. Instellen van het systeem
Instellen van een nieuw paswoord
Commando: PWD:XXXX,NEWPWD:YYYY%
XXXX
Huidig paswoord
YYYY
Nieuw paswoord (4 digits)
Voorbeeld:
PWD:1234,NEWPWD:2222%
Standaard paswoord: 1234
Nieuw paswoord: 2222
Manueel statusrapport
Commando: PWD:XXXX,STATUS%
[Ontvangen sms-bericht]
ST:XXX;T:2005/01/28/13:00;V:XXXX;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:X;K5:X;K6:X;K7:X;K8:
X;OUT1:Y;OUT2:Y;OUT3:Y;#
Voorbeeld:
ST:002;T:2005/01/28/13:00;V:8.15;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:1;K5:1;K6:X;K7:X;K8
:X;OUT1:1;OUT2:1;OUT3:1;#
ST
Serienummer
XXX
ASCII-code
T
Interne klok
XXXX
Jaar/maand/dag/uur
V
Voedingspanning
XXXX
K1
Alarmkanaal 1
K1:0 betekent gesloten
K1:1 betekent open
K1 ~ 8
Alarmkanaal 1 ~ 8
OUT1
Relaisuitgang 1
OUT1:0 betekent open
OUT1:1 betekent gesloten
OUT1 ~ 3
Relaisuitgang 1 ~ 3 (uitgangen 2 en 3
worden weergegeven maar zijn niet
beschikbaar)
Instellen van het serienummer
Commando: PWD:XXXX,SN:YYY%
XXXX
Paswoord
YYYY
Serienummer (0-999)
Voorbeeld:
PWD:1234,SN:268%
Paswoord: 1234 (standaard)
Geprogrammeerd serienummer: 268 (standaard: 000)
Instellen nummer controlecentrum & statusrapport
Deze twee waarden worden geprogrammeerd via één enkel commando.
(1) Het nummer van het controlecentrum is het telefoonnummer waarnaar het periodieke en het
regelmatige statusrapport verzonden wordt. Naast het periodieke statusrapport (bericht bij opstarten)
ontvangt dit nummer elk commando en het telefoonnummer dat het commando heeft verzonden. U
kunt maximaal 2 controlecentra instellen.
Commando: PWD:XXXX,CTRZ:YYYYYYYYYYY,MM#%
XXXX
Paswoord
Z
Nummer controlecentrum (max. 2 centra)
1 is het nummer van het 1ecentrum
2 is het nummer van het 2ecentrum
YYYYYYYYY
Telefoonnummer in het controlecentrum
MM
Code van het geautomatiseerde statusrapport
Voorbeeld:
PWD:1234,CTR1:123456789,04#%
Paswoord: 1234
Statusrapport om het uur (zie tabel hieronder)
(2) Het periodieke statusrapport en alle commando’s van elk ander nummer worden naar het eerste
controlecentrum verzonden (nummer 123456789).

CU2200 v3-03
23.10.2014 ©Velleman nv
18
Tabel automatisch statusrapport
00
Geen automatisch rapport
07
Om de 6 uren
01
Elke 5 minuten
08
Om de 12 uren
02
Elke 15 minuten
09
Elk dag (08h00)
03
Elke 30 minuten
10
Om de 2 dagen (08h00)
04
Om het uur
11
1e, 7e, 14e, 21e, 28edag (08h00)
05
Om de 2 uren
12
1e, 15edag (08h00)
06
Om de 3 uren
13
1edag van elke maand (08h00)
De CU2200 verzendt automatisch een statusrapport volgens de geprogrammeerde regelmaat via een
sms-bericht.
[Ontvangen sms-bericht]
ST:XXX;T:2006/10/08/06:15;V:XXXX;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:X;K5:X;K6:X;K7:X;K8:
X;OUT1:1;OUT2:1;OUT3:1;#
ST
Serienummer
XXX
ASCII-code
T
Interne klok
XXXX
Jaar/maand/dag/uur
V
Voedingsspanning
XXXX
K1
Alarmkanaal 1
K1:0 betekent gesloten
K1:1 betekent open
K1 ~ 8
Alarmkanaal 1 ~ 8
OUT1
Relaisuitgang 1
OUT1:0 betekent open
OUT1:1 betekent gesloten
OUT1 ~ 3
Relaisuitgangen 1 ~ 3
Voorbeeld:
ST:001;T:2005/01/27/12:00;V:8.14;A1:2312;A2:2131;K1:1;K2:0;K3:0;K4:1; O:1#
ST
Serienummer
001
T
Interne klok
Datum: 27 januari 2005, tijd: 12h00
V
Voedingsspanning
8.14VDC
K1
Alarmkanaal 1
1
Open
K2
Alarmkanaal 2
0
Gesloten
K3
Alarmkanaal 3
0
Gesloten
K4
Alarmkanaal 4
1
Open
O
Relaisuitgang 1
1
On
Bericht bij het opstarten
Bij het opstarten van het toestel wordt automatisch het bericht RESTART! naar het controlecentrum
verzonden.
Instellen interne klok
Commando: PWD:XXXX,TIME:AABBCCDDEE%
XXXX
Paswoord
AABBCCDDEE
Jaar/maand/dag/uur/minuut
Voorbeeld:
PWD:1234,TIME:0602031327%
Paswoord: 1234
Klok: 3 februari 2006, 13h27
Instellen van de telefoonnummers
Commando: PWD:XXXX,ALMNU1:ZZZZZZZZZZZ,2:ZZZZZZZZZZZ,3:ZZZZZZZZZZZ,4:ZZZZZZZZ
ZZZ,5:ZZZZZZZZZZZ,6:ZZZZZZZZZZZ,7:ZZZZZZZZZZZ,8:ZZZZZZZZZZZ#%
XXXX
Paswoord
ZZZZZZZZZZZ
Telefoonnummer
Voorbeeld 1:
PWD:1234,ALMNU1:12345678,2:36925814712,3:159357456,4:951753654,5:741852963,6:45678
9123,7: 369874123,8:125478963#%
Paswoord
1234
Een sms-bericht wordt verzonden naar volgende nummers wanneer
het alarm afgaat:
Nr. 1
12345678
Nr. 2
36925814712
Nr. 3
159357456
Nr. 4
951753654
Nr. 5
741852963
Nr. 6
456789123
Nr. 7
369874123
Nr. 8
125478963

CU2200 v3-03
23.10.2014 ©Velleman nv
19
Voorbeeld 2:
PWD:1234,ALMNU1:NUL,3:NUL#%
Paswoord
1234
In voorbeeld zijn volgende nummers gewist:
Nr. 1
12345678, not made
Nr. 2
36925814712, retained
Nr. 3
159357456, not made
Nr. 4
951753654, retained
b. Instellen van het alarm
Instellen van de alarmingang & waarschuwingsniveau
Commando: PWD:XXXX,ALMLEVELR:X,YY,ZZZZBBBB,NNN%
XXXX
Paswoord
R
Kanaalnummer alarm
X
0 betekent uitgeschakeld
1 betekent gesloten triggert het alarm
2 betekent open triggert het alarm
3 betekent zowel gesloten als open getriggerd alarm
YY
00 betekent alarm niet gemeld aan het controlecentrum
10 betekent alarm gemeld aan controlecentrum 1
01 betekent alarm gemeld aan controlecentrum 2
11 betekent alarm gemeld aan controlecentrum 1 en 2
ZZZZBBBB
Selecteren van de oproep en sms-berichtgeving
0 betekent geen rapport
1 betekent enkel sms-bericht
2 betekent enkel telefoonoproep=> (telefoonoproep niet
beschikbaar)
3 betekent eerst sms-bericht, daarna telefoonoproep =>
(telefoonoproep niet beschikbaar)
Z
Z
Z
Z
1e
2e
3e
4etelefoonnummer
B
B
B
B
5e
6e
7e
8etelefoonnummer
NNN
Relaisuitgang
0 betekent geen relaisuitgang
1 betekent relaisuitgang gestart door alarm
N
N
N
1e
2e
3erelaisuitgang
(2e en 3erelaisuitgang niet beschikbaar)
Voorbeeld 1:
PWD:1234,ALMLEVEL2:1,01,10000000,100%
Paswoord
1234
Alarmkanaal 2
Het alarm gaat af wanneer de ingang sluit
Controlecentrum 2 wordt door een sms-bericht gemeld
Telefoonnummer 1
Telefoonnummer 2
Telefoonnummer 3
Telefoonnummer 4-8
Relaisuitgang 1
Relaisuitgang 2
Relaisuitgang 3
Sms-bericht
Geen rapport
Geen rapport
Geen rapport
Getriggerd “Gesloten” door alarm
Geen controle (niet beschikbaar)
Geen controle (niet beschikbaar)
Instellen van het sms-bericht
Alarmkanalen 1 ~ 8
Commando: PWD:XXXX,ALMYTEXT:□□□□□□□□□□□□#%
XXXX
Paswoord
Y
Alarmkanaal (1 ~ 8)
E
0 Getriggerd alarm sluiten
1 Getriggerd alarm openen
□□□□□□□□
Sms-bericht (max. 130 karakters –geen spatie)
Example:
PWD:1234,ALM4T1XT:Door Contact1 Open#%
Password
1234
Alarmkanaal 4 wordt gestart door “Open Contact”, het sms-bericht “Door
Contact 1 Open” wordt naar de voorgeprogrammeerde telefoonnummers
verzonden.

CU2200 v3-03
23.10.2014 ©Velleman nv
20
Inhoud van het sms-bericht
De inhoud van een sms-bericht wordt bepaald door commando 8. De CU2200 verzendt het
voorgeprogrammeerde bericht naar dat welbepaalde alarmkanaal.
Commando: PWD:XXXX,READYTEXT%
XXXX
Paswoord
Y
Alarmkanaal (1 ~ 4)
De CU2200 verplichten een sms-bericht te sturen
Dit commando wordt gebruikt om een sms te sturen zodat de CU2200 getest kan worden.
Commando: PWD:XXXX,SENDMSA:XB%
XXXX
Paswoord
A
Telefoonnummer (1 ~ 8)
XB
Keuze sms-bericht
00: weergeven statusinhoud
01: gesloten getriggerd alarm kanaal 1, sms-bericht
02: gesloten getriggerd alarm kanaal 2, sms-bericht
03: gesloten getriggerd alarm kanaal 3, sms-bericht
04: gesloten getriggerd alarm kanaal 4, sms-bericht
05: gesloten getriggerd alarm kanaal 5, sms-bericht
06: gesloten getriggerd alarm kanaal 6, sms-bericht
07: gesloten getriggerd alarm kanaal 7, sms-bericht
08: gesloten getriggerd alarm kanaal 8, sms-bericht
09: manuele berichtinvoer
10: alarmbericht bij lage spanning
11: AD-kanaal 1, sms-bericht
12: AD-kanaal 2, sms-bericht
13: open getriggerd alarm kanaal 1, sms-bericht
14: open getriggerd alarm kanaal 2, sms-bericht
15: open getriggerd alarm kanaal 3, sms-bericht
16: open getriggerd alarm kanaal 4, sms-bericht
17: open getriggerd alarm kanaal 5, sms-bericht
18: open getriggerd alarm kanaal 6, sms-bericht
19: open getriggerd alarm kanaal 7, sms-bericht
20: open getriggerd alarm kanaal 8, sms-bericht
Voorbeeld:
PWD:1234,SENDMS4:09,Good Morning%
Password
1234
Het sms-bericht met inhoud “Good Morning” wordt naar
telefoonnummer 4 verzonden.
Foutbericht instelling A:
Number Choice Miss A niet tussen 1 ~ 8
Number Non Exist Geen telefoonnummer geprogrammeerd
Foutbericht instelling XB:
Did not specify SMS contents XB niet tussen 00 ~20
Antwoord:
Success! CU2200 heeft het bericht verzonden.
Failed! Verzenden niet gelukt maar telefoonnummer bestaat.
Relaisuitgang
Commando: PWD:XXXX,COUTN:Y%
Paswoord
1234
N
Kanaal relaisuitgang (1 ~ 3) (uitgangen 2 en 3 zijn niet beschikbaar)
Y
1
0
Uitgang inschakelen (gesloten)
Uitgang uitschakelen (open)
De relaisuitgang is standaard een N.O.-uitgang.
Commando COUTN:1 is ongeldig wanneer de relaisuitgang door het alarm wordt gestart. Volgend
bericht zal worden verzonden: ST:XXX.
Herstel de relaisuitgang met COUTN:0.
Vertraging relaisuitgang
Commando: PWD:XXXX,OUTNDLAY:YYYY%
XXXX
Paswoord
N
Kanaal relaisuitgang (1 ~ 3) (uitgangen 2 en 3 zijn niet beschikbaar)
YYYY
0000 –9999 seconden
0000 In- en uitschakelen van de uitgang (standaard)
0005 Inschakelen van de uitgang gedurende 5 seconden en opnieuw uitschakelen
Uitschakelen van de uitgang gedurende 5 seconden en opnieuw inschakelen