INDUSTRIAL AIR CIRCULATOR Form 472812
Designed to move high volumes of directed airflow at low velocity, keeping individuals comfortable and productive in factories and warehouses. Galvanized steel
construction provides high resistance to corrosion. Motors are ball bearing type. Single phase circulators have 115 volt, 2-speed motors that allow the user to
adjust airflow to desired setting and include 9-ft. factory wired, 3-conductor cord with grounded, molded plug and built-in cord wrap. 3-phase circulators include
10-ft. pre-wired pigtail. Guards are coated with a protective finish and comply with the OSHA Standard 1910.212 (1/2” max opening). Fans are UL/cUL Listed
Standard 507.
NOTE: Mounting accessory required, not included.
Model Prop
Dia.
Full Load
Amps HP Fan RPM CFM Air Velocity (FPM)
High Low @ 20 Ft. @ 40 Ft. @ 60 Ft.
Direct-Drive
MAC-18-339-B4-J1 18" 1.9 1/4 1075/750 3,600 2,400 415/274 250/165 110/73
MAC-20-327-B4-J1 20 1.9 1/4 1075/750 4,500 3,000 490/323 300/198 150/99
MAC-24-323-B3-J1 24 3.8 1/3 1075/750 6,100 4,100 350/245 140/100 50/35
MAC-30-324-C5-J1 30 5.0 1/2 825/600 9,600 7,000 400/280 165/115 65/45
MAC-36-322-C5-J1 36 5.0 1/2 825/600 12,500 9,100 372/261 235/164 179/125
MAC-42-320-C7-J1 42 8.9 3/4 825/600 16,000 11,600 418/262 284/204 240/173
MAC-42-320-C7-U3 42 3.6-3.6/1.9 3/4 825 16,000 — 418 284 240
MAC-48-316-C7-J1 48 8.9 3/4 825/600 19,500 14,100 464/279 344/260 316/232
MAC-48-316-C7-U3 48 3.6-3.6/1.9 3/4 825 19,500 — 464 344 316
Belt-Drive
MAC-36-5-J1 36" 5.0 1/2 460/304 14,000 8,400 417/292 263/184 200/140
MAC-42-7-J1 42 8.9 3/4 470/380 18,000 11,500 470/295 320/230 270/195
MAC-42-7-U3 42 3.2-3.4/1.7 3/4 470 18,000 — 470 320 270
MAC-48-7-J1 48 8.9 3/4 390/260 21,000 14,000 500/300 370/280 340/250
MAC-48-7-U3 48 3.2-3.4/1.7 3/4 390 21,000 — 500 370 340
Model Prop
Dia.
Outside
Dia. Depth Blades Volts Phase Speeds
Direct-Drive
MAC-18-339-B4-J1 18" 191⁄2" 13
1⁄2" 3 115 1 2
MAC-20-327-B4-J1 20 211⁄2131⁄23 115 1 2
MAC-24-323-B3-J1 24 251⁄2131⁄23 115 1 2
MAC-30-324-C5-J1 30 311⁄2131⁄23 115 1 2
MAC-36-322-C5-J1 36 371⁄2131⁄23 115 1 2
MAC-42-320-C7-J1 42 431⁄2211⁄43 115 1 2
MAC-42-320-C7-U3 42 431⁄2211⁄43 208-230/460 3 1
MAC-48-316-C7-J1 48 50 211⁄43 115 1 2
MAC-48-316-C7-U3 48 50 211⁄43 208-230/460 3 1
Belt-Drive
MAC-36-5-J1 36" 371⁄2" 21
1⁄4" 6 115 1 2
MAC-42-7-J1 42 431⁄2211⁄46 115 1 2
MAC-42-7-U3 42 431⁄2211⁄46 208-230/460 3 1
MAC-48-7-J1 48 50 211⁄46 115 1 2
MAC-48-7-U3 48 50 211⁄46 208-230/460 3 1
PERFORMANCE
Depth
Outside Dia.
Figure 1 — Dimensions
E33599

2
ENGLISH
GENERAL SAFETY
WARNING: To reduce the risk of fire, electrical shock, or injury to persons, observe the following:
a. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting the means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION: Do not depend on any switch to disconnect power supply. Always unplug the power cord or turn off and lock disconnecting means as described.
DANGER: Do not place body parts or objects in circulator or motor openings while motor is connected to the power source.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. Do not use a three-prong to two-prong
adapter on the power cord.
WARNING: To reduce the risk of electric shock, do not expose to water or rain.
1. Read and follow all instructions, cautionary markings and make sure power source conforms to the requirement of the equipment.
2. Avoid using extension cords. If used, be sure cord is UL rated and of proper type, gauge and length. Never operate more than one circulator from a single
extension cord.
3. Do not kink power cord or allow it to contact oil, grease, hot surfaces, sharp objects or chemicals. Replace worn or damaged cord immediately.
WARNING: Do not use general purpose circulators in flammable, explosive, chemical-laden, or wet or rainy atmospheres. Use special purpose circulators
designed for particular application. Do not attach ductwork to a circulator.
4. In critical applications, use a suitable alarm (air switch, temperature sensor, etc.) should the circulator malfunction.
OPERATION
CAUTION: Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it
will not be tripped over.
WARNING: Use only GFCI receptacles.
WARNING: Not for outdoor applications.
1. Two-speed circulators operate by flipping the switch: High-Off-Low.
2. Keep circulator free from obstructions.
MAINTENANCE
CAUTION: To reduce the risk of injury, disconnect and lockout power source before servicing. Always unplug the power cord.
1. Periodically clean propeller, guard, and motor when excessive dirt and particles accumulate. Allow motor sufficient time to cool as it may be hot enough to
cause injury.
2. Periodically check belt for wear and tightness. When replacing belt, use same type that was supplied with unit.
3. Follow motor manufacturer’s instructions for motor lubrication.
4. Check for unusual noises when circulator is running.
5. Periodically inspect and tighten all bolts.
IMPORTANT: When making repairs, use only VENCO PRODUCTS authorized parts.
IMPORTANT: Do not force belts on or off. This may cause cords to break, leading to premature belt failure.
WARNING: If the electrical cord is damaged, it must be replaced by a qualified service representative to avoid risk.
UNPACKING
1. Inspect for any damage that may have occurred during transit.
2. Shipping damage claim must be filed with carrier.
3. Check all bolts, screw, setscrews, etc. for looseness that may have occurred during transit. Retighten as needed.
ASSEMBLY AND INSTALLATION
WARNING: Installation and troubleshooting to be performed only by qualified person(s).
CAUTION: To reduce the risk of injury, use only with recommended VENCO Products accessories in owners manual.
1. All 115V, 1-phase circulators include a factory wired, 3-conductor cord with grounded molded plug.
2. Where plug is not provided, connect power in accordance with the NEC and all local codes. 3-phase units are factory wired for 460 volt connection. Refer to
the wiring diagram on the motor for 208-230 volt connection.
3. To mount air circulator, refer to the instruction provided with the VENCO Products corresponding accessory.
NOTE: Mounting accessory required, not included.
OPTIONAL ACCESSORIES
1. Suspension-Mount Kit (MAC-SM)
2. Ceiling-Mount Kit (MAC-CM-S, MAC-CM-L, MAC-CM-XL)
3. Wall-Mount Kit (BKT-WPC-200)
4. Dock Arm Kit (MAC-DA)
5. Mobile Kit (MAC-WK-S, MAC-WK-L)
6. Mobile Tiltable Carriage Kit (MAC-TC-24, MAC-TC-30, MAC-TC-36DD, MAC-TC-42, MAC-TC-48, MAC-TC-36BD)

3
ENGLISH
PARTS REPLACEMENT — DIRECT-DRIVE Contact your local VENCO PRODUCTS distributor for repair parts
Description Repair part for model:
MAC-18-
MAC-18-
339-B4-J1
339-B4-J1
MAC-20-
MAC-20-
327-B4-J1
327-B4-J1
MAC-24-
MAC-24-
323-B3-J1
323-B3-J1
MAC-30-
MAC-30-
324-C5-J1
324-C5-J1
MAC-36-
MAC-36-
322-C5-J1
322-C5-J1
MAC-42-
MAC-42-
320-C7-J1
320-C7-J1
MAC-42-
320-C7-U3
MAC-48-
MAC-48-
316-C7-J1
316-C7-J1
MAC-48-
316-C7-U3
(A) Single Guard and Clips 849172 849176 849177 849478 849179 849180 849180 849181 849181
(B) Propeller 335561 335607 335564 335597 335610 335654 335654 335612 335612
(C) Tube Wrap Assembly 849190 849191 849192 849193 849194 849195 849195 849196 849196
(D) Cord and Switch Assembly 852971 852971 852971 852971 852971 852971 — 852971 —
(E) Motor 310424 310424 310425 310417 310417 310426 311554 310426 311554
Issue Possible Cause Corrective Action
Circulator inoperative
Blown fuse or open circuit breaker Replace or repair
Defective motor or switch Replace or repair
Broken belts Replace
Circulator cycles on and off Thermal protector
Check for obstructions to airflow, low or high
voltage, excessive intake air temperature above
104ºF
Faulty wiring or control switch Replace or repair
Excessive noise while operating
Loose, worn or dirty belt Adjust, replace or clean
Loose or damaged propeller Tighten or replace
Motor not secure Tighten motor nuts
Insufficient airflow Guard excessively dirty Clean guards
Belt slippage Replace and/or adjust tension
TROUBLESHOOTING WARNING: Troubleshooting to be performed only by a qualified person(s).
D
B
E
C
A
Figure 2 — Direct-Drive Replacement Parts

®
WARRANTY
VENCO PRODUCTS warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or
parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted
by the motor manufacturer for a period of one year. Should motors furnished by VENCO PRODUCTS prove defective during this period, they should be returned
to the nearest authorized motor service station. VENCO PRODUCTS will not be responsible for any removal or installation costs.
As a result of our commitment to continuous improvement, VENCO PRODUCTS reserves the right to change specifications without notice.
472812 • Industrial Air Circulators, Rev. 3, November 2011
Copyright 2011 © VENCO PRODUCTS • www.vencoproducts.com
Description Repair part for model:
MAC-36-5-J1 MAC-42-7-J1 MAC-42-7-U3 MAC-48-7-J1 MAC-48-7-U3
(A) Single Guard and Clips 849179 849180 849180 849181 849181
(B) Propeller 848852 814551 814551 841630 841630
(C) Shaft 365021 365021 365021 365021 365021
(D) Bearings 360100 360100 360100 360100 360100
(E) Shaft Pulley 351994 351772 351801 352015 352015
(F) Motor 310472 310250 311223 310250 311223
(G) Belt 345132 345175 345173 345249 345249
(H) Motor Pulley 354145 354145 354145 354145 354145
(I) Tube Wrap Assembly 849197 849198 849198 849199 849199
(J) Cord and Switch Assembly 852971 852971 — 852971 —
J
I
A
H
F
B
C
E
D
G
PARTS REPLACEMENT — BELT-DRIVE Contact your local VENCO PRODUCTS distributor for repair parts
Figure 3 — Belt-Drive Replacement Parts

®
GARANTÍA
VENCO PRODUCTS garantiza que este equipo está libre de defectos de materiales y de mano de obra durante un período de un año a partir de la fecha de
compra. Todas las unidades o partes que se demuestre que presentan defectos durante el período de garantía se reemplazarán según nuestro criterio cuando
se devuelvan a nuestra fábrica, previo pago de su transporte. Los motores están garantizados por su fabricante durante un período de un año. Si se demuestra
que los motores que proporcione VENCO PRODUCTS presentan defectos durante este período, se deben devolver a la estación de mantenimiento de motores
autorizada más cercana. VENCO PRODUCTS no será responsable de ningún costo de eliminación o instalación.
Como resultado de nuestro compromiso de mejorar constantemente, VENCO PRODUCTS se reserva el derecho de cambiar las especificaciones sin previo aviso.
472812 • Circuladores de Aire Industriales, Mod. 3, noviembre de 2011
Copyright 2011 © VENCO PRODUCTS • www.vencoproducts.com
Descripción Repuesto para modelo:
MAC-36-5-J1 MAC-42-7-J1 MAC-42-7-U3 MAC-48-7-J1 MAC-48-7-U3
(A) Protector Único y Sujetadores 849179 849180 849180 849181 849181
(B) Hélice 848852 814551 814551 841630 841630
(C) Eje 365021 365021 365021 365021 365021
(D) Rodamientos 360100 360100 360100 360100 360100
(E) Polea del Eje 351994 351772 351801 352015 352015
(F) Motor 310472 310250 311223 310250 311223
(G) Correa 345132 345175 345173 345249 345249
(H) Polea del Motor 354145 354145 354145 354145 354145
(I) Conjunto de Envoltorio de Tubo 849197 849198 849198 849199 849199
(J) Conjunto de cable e interruptor 852971 852971 — 852971 —
J
I
A
H
F
B
C
E
D
G
REEMPLAZO DE PARTES — TRANSMISIÓN POR CORREA Comuníquese con su distribuidor local de VENCO PRODUCTS para obtener repuestos
Figura 3 — Repuestos para la Transmisión por Correa

ESPAÑOL 3
REEMPLAZO DE PARTES — TRANSMISIÓN DIRECTA Comuníquese con su distribuidor local de VENCO PRODUCTS para obtener repuestos
Descripción Repuesto para modelo:
MAC-18-
MAC-18-
339-B4-J1
339-B4-J1
MAC-20-
MAC-20-
327-B4-J1
327-B4-J1
MAC-24-
MAC-24-
323-B3-J1
323-B3-J1
MAC-30-
MAC-30-
324-C5-J1
324-C5-J1
MAC-36-
MAC-36-
322-C5-J1
322-C5-J1
MAC-42-
MAC-42-
320-C7-J1
320-C7-J1
MAC-42-
320-C7-U3
MAC-48-
MAC-48-
316-C7-J1
316-C7-J1
MAC-48-
316-C7-U3
(A) Protector Único y Sujetadores 849172 849176 849177 849478 849179 849180 849180 849181 849181
(B) Hélice 335561 335607 335564 335597 335610 335654 335654 335612 335612
(C) Conjunto de Envoltorio de Tubo 849190 849191 849192 849193 849194 849195 849195 849196 849196
(D) Conjunto de cable e interruptor 852971 852971 852971 852971 852971 852971 — 852971 —
(E) Motor 310424 310424 310425 310417 310417 310426 311554 310426 311554
Problema Causas posibles Medida Correctiva
El circulador no funciona
Se quemó un fusible o hay un cortacircuitos
abierto Reemplácelo o repárelo
Motor o interruptor defectuoso Reemplácelo o repárelo
Correas rotas Reemplácelas
El circulador se enciende y se apaga Protector térmico
Compruebe si hay obstrucciones en el flujo de
aire, voltaje bajo o alto, temperatura excesiva del
aire de entrada por sobre los 60º C (140° F)
Cableado o interruptor de control defectuoso Reemplácelo o repárelo
Ruido excesivo durante el funcionamiento
Correa suelta, desgastada o sucia Ajústela, reemplácela o límpiela
La hélice está suelta o dañada Apriétela o reemplácela
El motor no está fijo Apriete las tuercas del motor
Flujo de aire insuficiente El protector está excesivamente sucio Limpie los protectores
Deslizamiento de la correa Reemplácela o ajuste la tensión
SOLUCIÓN DE PROBLEMAS ADVERTENCIA: La solución de problemas la debe realizar sólo una persona calificada.
D
B
E
C
A
Figura 2 — Repuestos para la Transmisión Directa

ESPAÑOL 2
SEGURIDAD GENERAL
ADVERTENCIA: Para reducir el riesgo de incendio, descarga eléctrica o lesiones a personas, respete lo siguiente:
a. Use esta unidad sólo como lo indica el fabricante. Si tiene dudas, comuníquese con el fabricante.
b. Antes de realizar mantenimiento o de limpiar la unidad, desconecte la alimentación en el panel de servicio y bloquee el servicio desconectando los medios
para evitar que la alimentación se active en forma accidental. Cuando no se puedan bloquear los medios de desconexión del servicio, coloque firmemente
un dispositivo de advertencia prominente, como una etiqueta, en el panel de servicio.
PRECAUCIÓN: No dependa de ningún interruptor para desconectar el suministro eléctrico. Desenchufe siempre el cable de alimentación o apague y bloquee
los medios de desconexión según se describe.
PELIGRO: No coloque partes del cuerpo ni objetos en el circulador o en los orificios del motor mientras éste se encuentre conectado a la fuente de energía.
ADVERTENCIA: Para reducir el riesgo de incendio o descarga eléctrica, no utilice este ventilador con ningún dispositivo de control de velocidad de estado
sólido. No use un adaptador de tres a dos clavijas en el cable de alimentación.
ADVERTENCIA: Para reducir el riesgo de descargas eléctricas, no lo exponga al agua ni a la lluvia.
1. Lea y siga todas las instrucciones, y las marcas de precaución. Asegúrese de que la fuente de energía esté en conformidad con los requisitos del equipo.
2. Evite usar cables de extensión. Si los utiliza, asegúrese de que tengan clasificación UL y que sean del tipo, calibre y largo adecuados. Nunca utilice un sólo
cable de extensión para alimentar a más de un circulador.
3. No enrosque el cable de alimentación ni permita el contacto con aceite, grasa, superficies calientes, objetos filosos ni productos químicos. Reemplace
inmediatamente los cables desgastados o dañados.
ADVERTENCIA: No use circuladores de uso general en atmósferas inflamables, explosivas, cargadas de productos químicos, húmedas o lluviosas. Use
circuladores para propósitos especiales diseñados para aplicaciones particulares. No acople una red de conductos a un circulador.
4. En aplicaciones críticas, use una alarma adecuada (interruptor de aire, sensor de temperatura, etc.) en caso de que se produzca un funcionamiento
defectuoso del circulador.
OPERACIÓN
PRECAUCIÓN: No pase el cable por debajo de alfombras. No cubra el cable con alfombras pequeñas, alfombrillas de pasillo ni cubiertas similares. Disponga el
cable lejos del área de tránsito y donde no provoque tropiezos ni caídas.
ADVERTENCIA: Use sólo tomacorrientes GFCI.
ADVERTENCIA: No apto para aplicaciones al aire libre.
1. Las circuladores de dos velocidades funcionan al mover el interruptor: High-Off-Low (Alto-Apagado-Bajo).
2. Mantenga el circulador libre de obstrucciones.
MANTENIMIENTO
PRECAUCIÓN: Para reducir el riego de lesiones, desconecte y bloquee la fuente de energía antes de realizar mantenimiento. Desconecte siempre el cable de
alimentación.
1. Limpie en forma periódica la hélice, el protector y el motor cuando se acumulen polvo y partículas en exceso. Deje que el motor se enfríe, puesto que puede
estar lo suficientemente caliente para provocar lesiones.
2. Revise de manera periódica el desgaste y el apriete de la correa. Al reemplazar la correa, use el mismo tipo que se incluye con la unidad.
3. Siga las instrucciones del fabricante del motor para su lubricación.
4. Cuando esté funcionando el circulador, revise si existen ruidos anormales.
5. Efectúe una inspección en forma periódica y apriete todos los pernos.
IMPORTANTE: Al hacer reparaciones, use sólo las partes autorizadas por VENCO PRODUCTS.
IMPORTANTE: No fuerce las correas para colocarlas o sacarlas. Ello puede causar que los cables se rompan, lo que lleva a una falla prematura de la correa.
ADVERTENCIA: Si el cable eléctrico está dañado, lo debe reemplazar un representante de servicio calificado para evitar riesgos.
DESEMBALAJE
1. Revise si existen daños que se puedan haber producido durante el transporte.
2. Se debe presentar una queja por daños de transporte a la empresa de transporte.
3. Compruebe que ninguno de los pernos, tornillos o tornillos de fijación se haya soltado durante el transporte. Vuelva a apretarlos según sea necesario.
MONTAJE E INSTALACIÓN
ADVERTENCIA: La instalación y la solución de problemas deberá realizarla sólo una persona calificada.
PRECAUCIÓN: Para reducir el riesgo de lesiones, usar sólo con los accesorios VENCO Products recomendados que se indiquen en el manual del propietario.
1. Todos los circuladores de aire de 115 V monofásicos incluyen un cable conectado en fábrica de 3 conductores con un enchufe con conexión a tierra
moldeado.
2. Donde no se proporcione un enchufe, conecte la alimentación según los códigos NEC y locales. Las unidades trifásicas se conectan en fábrica para una
conexión de 460 voltios. Consulte el diagrama del cableado en el motor para ver la conexión de 208-230 voltios.
3. Para montar el circulador de aire, consulte las instrucciones que se incluyen con el accesorio VENCO Products correspondiente.
NOTA: No se incluye el accesorio de montaje requerido.
ACCESORIOS OPCIONALES
1. Juego de Montaje en Cielo (MAC-CM-S, MAC-CM-L, MAC-CM-XL)
2. Juego de Montaje en Suspensión (MAC-SM)
3. Juego de Montaje en Pared (BKT-WPC-200)
4. Juego de Brazo de Acoplamiento (MAC-DA)
5. Juego Móvil (MAC-WK-S, MAC-WK-L)
6. Juego de Carro Basculante Móvil (MAC-TC-24, MAC-TC-30, MAC-TC-36DD, MAC-TC-42, MAC-TC-48, MAC-TC-36BD)

ENGLISH
ESPAÑOL
Lea y guarde estas instrucciones para referencia futura.
Lea detenidamente antes de intentar montar, instalar, operar o dar mantenimiento al
producto que se describe. Protéjase y proteja a los demás prestando atención a toda
la información de seguridad. Si no sigue estas instrucciones, podría ocasionar lesiones
personales o daños a la propiedad.
®
DIMENSIONES Y ESPECIFICACIONES
CIRCULADOR DE AIRE INDUSTRIAL Formulario 472812
Está diseñado para mover grandes volúmenes de flujo de aire directo a baja velocidad, manteniendo a las personas cómodas y productivas en fábricas
y almacenes. Está fabricado de acero galvanizado para proporcionar alta resistencia a la corrosión. Los motores son del tipo cojinetes de rodamientos.
Circuladores con motor monofásicos son de 115 voltios, motores de 2-velocidades que permiten al usuario ajustar el flujo del aire a la configuración deseada
e incluye cable de 9 pies y de 3 conductores, instalado en fabrica. Los circuladores con motores trifásicos incluyen conducto con cables de 10 pies también
instalados en fabrica. Las protecciones están revestidas con un acabado protector y cumplen la norma de OSHA 1910.212 (1,3 cm [1/2 pulg.] de abertura
máxima). Los ventiladores aparecen en las listas de UL/cUL con la norma 507.
NOTA: No se incluye el accesorio de montaje requerido.
Modelo Diá. de la
Hélice
Amperios
a Plena
Carga
HP RPM del Ventilador
CFM Velocidad del Aire (FPM)
Alto Bajo a 20 Pies a 40 Pies a 60 Pies
Transmisión directa
MAC-18-339-B4-J1 45,7 cm 1,9 1/4 1075/750 3.600 2.400 415/274 250/165 110/73
MAC-20-327-B4-J1 50,8 1,9 1/4 1075/750 4.500 3.000 490/323 300/198 150/99
MAC-24-323-B3-J1 61 3,8 1/3 1075/750 6.100 4.100 350/245 140/100 50/35
MAC-30-324-C5-J1 76,2 5,0 1/2 825/600 9.600 7.000 400/280 165/115 65/45
MAC-36-322-C5-J1 91,4 5,0 1/2 825/600 12.500 9.100 372/261 235/164 179/125
MAC-42-320-C7-J1 107 8,9 3/4 825/600 16.000 11.600 418/262 284/204 240/173
MAC-42-320-C7-U3 107 3,6-3,6/1,9 3/4 825 16.000 — 418 284 240
MAC-48-316-C7-J1 122 8,9 3/4 825/600 19.500 14.100 464/279 344/260 316/232
MAC-48-316-C7-U3 122 3,6-3,6/1,9 3/4 825 19.500 — 464 344 316
Transmisión por correa
MAC-36-5-J1 91,4 cm 5,0 1/2 460/304 14.000 8.400 417/292 263/184 200/140
MAC-42-7-J1 107 8,9 3/4 360/238 18.000 11.500 470/295 320/230 270/195
MAC-42-7-U3 107 3,2-3,4/1,7 3/4 470 18.000 — 470 320 270
MAC-48-7-J1 122 8,9 3/4 355/235 21.000 14.000 500/300 370/280 340/250
MAC-48-7-U3 122 3,2-3,4/1,7 3/4 390 21.000 — 500 370 340
Modelo Diá. de la
Hélice
Diá.
Exterior Profundidad Paletas Voltios Fase Velocidades
Transmisión directa
MAC-18-339-B4-J1 45,7 cm 49,5 cm 34,3 cm 3 115 1 2
MAC-20-327-B4-J1 50,8 54,6 34,3 3 115 1 2
MAC-24-323-B3-J1 61 64,8 34,3 3 115 1 2
MAC-30-324-C5-J1 76,2 80 34,3 3 115 1 2
MAC-36-322-C5-J1 91,4 95,2 34,3 3 115 1 2
MAC-42-320-C7-J1 107 110,5 53,3 3 115 1 2
MAC-42-320-C7-U3 107 110,5 53,3 3 208-230/460 3 1
MAC-48-316-C7-J1 122 127 53,3 3 115 1 2
MAC-48-316-C7-U3 122 127 53,3 3 208-230/460 3 1
Transmisión por correa
MAC-36-5-J1 91,4 cm 95,2 cm 53,3 cm 6 115 1 2
MAC-42-7-J1 107 110,5 53,3 6 115 1 2
MAC-42-7-U3 107 110,5 53,3 6 208-230/460 3 1
MAC-48-7-J1 122 127 53,3 6 115 1 2
MAC-48-7-U3 122 127 53,3 6 208-230/460 3 1
RENDIMIENTO
Profundidad
Diá. Exterior
Figura 1 — Dimensiones
E33599
This manual suits for next models
13
Table of contents
Other VENCO Fan manuals

VENCO
VENCO VJC-200 User manual

VENCO
VENCO MAC-TC-24 User manual

VENCO
VENCO VCFI Series User manual

VENCO
VENCO VCFI User manual

VENCO
VENCO VAX-EX User manual

VENCO
VENCO VAX General instructions

VENCO
VENCO VAX-J series User manual

VENCO
VENCO VD-EX User manual

VENCO
VENCO MAC-SM User manual

VENCO
VENCO MAC-CM-S User manual
Popular Fan manuals by other brands

Maxwell
Maxwell MW-3545 W user manual

RH Baby&child
RH Baby&child VINTAGE AIRPLANE PROPELLER Assembly instructions

NuAire
NuAire HPKF Installation and Maintenance

Vornado
Vornado PIVOT 3U user manual

Westinghouse
Westinghouse WSFNCP001BK instruction manual

Fanimation
Fanimation KERRING FP3073 Series instructions