Step 1: Connect the EARTH wire to the terminal port marked on the terminal block mounting
bracket.
Step 2: Connect the supply LIVE wire to the wall controller terminal port labelled "TO
240V/50HZ”.
Step 3: Connect a wire from the Fan Live "L" from the terminal block mounting bracket, to the
terminal port labelled "FOR FAN-L" on the wall controller.
Step 4: Connect a wire from the Light Live from the terminal mounting bracket, to the
terminal port labelled "FOR LIGHT-L" on the wall controller.
NOTE: The fan light wiring is only applicable to fan models with a light.
Step 5: Connect the supply Neutral wire to the terminal port marked "N" on the terminal block
mounting bracket.
Once all the above steps have been followed, you are now ready to restore the mains power
supply. Make sure there is nobody near or under the fan, then turn ON the isolation switch to
begin operation.
Step 1: Turn “ON” isolation switch.
NOTE: For models “with light”, light will default to “ON” at 100% output.
Step 2: Use Eco/Med/High buttons to alter the fan speed.
WITH LIGHT MODELS
Step 3: Press Light “ON/OFF” for light.
Step 4: Press the “STEP DIM” button to transition through 75%, 50%, 25% then back to 100% of light
output.
(The units come factory paired, but if you wish to pair a remote handpiece to multiple fans, see below)
Step 1: Turn “OFF” isolation switch.
Step 2: Turn “ON” isolation switch and within 10 seconds, press LIGHT “ON” button for 3-4 seconds
until a “Tick-Tack” sound is heard. (Repeat steps above if not successful).