Assembly Type LAW
› Z-WRG PLUS › MOUNTING INSTRUCTION 05
1. Creation of the wall opening
Insert Structural work Ring Module Set
Outside
Inside
3. Ring Module Set slide into the wall,
adjusting it and fixing it without tension
b) by adjusting the ring module sets the
Wall thickness, are still present connection
wall thickness the connection joints have to be
sealed diffusion resistantwith VX-FK
5. Framed fixing in the wall with two component
polyurethane foam VX-2K
6. Protecting the Ventilation Unit from Dirt
7. Install Façade Cover after the completion of
plaster and painting works
4. For larger openings, cavities
additionally with rock wool, mineral wool
stuffed or isolate expert guidance to customers
a) seal room-sided opening gap between wall and
channel diffusion resistant and permanently
elastic (Ventomaxx Installation Sealing Adhesive
VX-FK)
2. Making overall length with ring modules
(wall thickness incl. insulation system and
Plastering)
Mounting instructions - V-WRG Rondo Plus - Mounting Type LAW
Cross Section
Illustration of Solid Wall + Insulation System
Wall Thickness
Preparing the total length
a) Opening 200 mm or angular H / B 200 x 190
Making mm and hold in shell construction
b) Empty tube and electrical connection
NYM-J 3x1.5 provide!
b) in order to avoid any kind of damage to the
ventilator during the construction phase, store
them in a well- protected place until the final
assembly.
d) after completion of electrical work to
Clipping electric protective cover and the
Hang the appliance control panel
a) before you start working always pull the plug or
switch off the flush!
9. Electronic Installation must be carried out
by a professional!
a) depending on the desired place for the interior
cover (air outlet on top or bottom), the electric
cable has to be installed like the pattern shows
you (the standard air outlet is on top)
Installation cable
NYM-J 3x1,5 provide
The ring module set is for use in
Wall thicknesses from 300 mm designed;
CAUTION: reduction only on the outside!
8. Install interior housing right before the
completion of the construction phase
a) the room-side housing can be applied to
provided fixing points of RS-LAW
or attached to the wall are.
b) to avoid deformations on the housing tighten
screws gently and uniformly
b) Electrical connection Perform according
to the attached wiring diagram.
f) further details should be in a timely manner
Start of installation, to clarify project basis;
We are pleased to help you on this request
e) the device is now according to operating manual
ready for use.
Install Façade
Covering and
Interior Housing
c) at LAW-assembly is a slope of Ring module sets
plan at 1,5-3°decline of your telescope unit
from inside to outside
c) Commissioning of the units according to
instructions Perform (Master / Slave / groups etc.)
a) therefore use the included protective cover
during the whole construction phase
(plaster cover of RS-LAW)
The illustration shows
the V-WRG RondoPlus in
Mounting Version LAW,
straight through the wall
In the lower part is an on-site seal between structual work construction ring Module Set
and base plate facade cover required (eg aluminum adhesive tape; Ventomaxx sealing adhesive VX-FK);
at the top of the hood and sides of a seal on the facade is necessary.
Achieve 1,5 to 3° Decline
via EPS Assembly Wedge
sound insulated
Order-No.: 9500-0030SP
Sealing Adhesive
facade cover
FA-LAW-K
Ring-modul-Set
RS-LAW
device unit
V-WRG RONDO Plus
Plaster Cover
RS-LAW
Plaster Cover
Please note Mounting instructions for facade cover!
InsideInside
Outside Outside Outside