SAFETY INFORMATION
Before installing the VRF-1000 model, please read these
instructions and familiarize yourself with the requirements
and functions. If any questions or problems arise during the
installation, please contact Bindicator®Applications at
1-800-778-9242.
The VRF-1000 model must only be installed and operated
as described in this operating instruction. Please note that
other action can cause damage for which Bindicator®does
not take responsibility. If the model is not installed correctly
or used in approved applications, dangers may arise such
as product overflow.
Ensure that all personnel installing, wiring, and calibrating this device are
suitably qualified.
Observe all local and national electrical codes for the wiring of this device.
IMPORTANT!
Either AC or DC power is to be connected to the power input depending on
the model. Consult the nameplate of the unit. Models beginning with
VRF1A are AC powered units and accept any voltage between 85 VAC and
265 VAC. Models beginning with VRF1D are DC powered units and accept
any voltage between 9 VDC and 36 VDC.
IMPORTANT!
An electrical earth ground connection must be made to the housing input
ground screw. See Figure 1 for location. This connection is needed for both
electrical safety and proper operation of the unit. This is required for both
AC and DC units.
External ground wire must be connected to tank wall or top of tank.
VRF-1000 Series
of Variable Radio Frequency
Point Level Sensors
Integral Electronics with Opti-SenseTM
Quick-Start Guide
150 Venture Boulevard
Spartanburg, SC 29306
Phone: (864) 574-8060, Fax: (864) 574-8063
Customer Care: (800) 778-9242
Internet: http://www.bindicator.com
email: sales@bindicator.com
© 2006 All rights reserved.
All data subject to change without notice. VRF 180400 Rev. B 12/06
Please see VRF180000 for complete installation guidelines.
Dimensional and electrical drawings of the VRF-1000 models are available in
various formats from Bindicator's website; www.Bindicator.com
From the home page, click on the link Installation Manuals/VRF180000 to obtain
the applicable drawing.
If access to the internet is not available, please contact Bindicator®Customer
Care Department at 1-800-778-9242 for assistance in obtaining these drawings.
Start-up & Operation
The VRF-1000 will automatically begin operation when powered up. It should be
initially powered after it is installed in the application and with material below the
probe. When initially powered up, the VRF-1000 will automatically begin a 3
second calibration operation. If the unit is powered on the bench prior to instal-
lation, or moved from one installation to another, recalibration is required.
Momentarily press the recalibration pushbutton. The green calibration indication
LED will go off, and after 3 seconds illuminate to indicate calibration is complete.
The VRF-1000 is shipped from the manufacturer with the automatic
calibration/recalibration feature enabled. If only manual pushbutton
calibration/recalibration is desired, set SW1 DIP switch position 6 to off.
Figure 2. High/Low Level Failsafe
(See Fig. 3 and 4)
SW1
Position 1
SW1
Position 2
Sensitivity
Off Off 1 pF, High
Off On 2 pF
On Off 5 pF, Medium
On On 10 pf, Low
SW1
Position 3
SW1
Position 4
Time
Delay
Off Off 1 second
Off On 4 seconds
On Off 8 seconds
On On 15 seconds
Figure 3. Sensitivity Settings
Figure 4. Time Delay Settings
(See Fig. 2)
Figure 1. VRF-1000 Electronics
Failsafe Selection
High Level Failsafe Operation
· DIP Switch SW1 position 5 is on.
· If the electrical power fails, the relay turns off. This indicates material
as if the tank were full.
Low Level Failsafe Operation
· DIP Switch SW1 position 5 is off.
· If the electrical power fails, the relay turns off. This indicates material
as if the tank were empty.
The output relay contacts are labeled in the un-powered alarm state. The relay is energized
when the VRF-1000 is not alarmed. This status may be opposite that of other Bindicator®
brand units. If the VRF-1000 is replacing an older Model RF-8000 or RF-9000 unit,
connections will need to be opposite. If a connection was made to NC1 terminal of the
RF8/9000, connect now to the NO1 terminal of the VRF-1000. C1 and C2 connections
would remain the same.

Other Venture Measurement Accessories manuals

Venture Measurement Genuine Bindicator VRF-2000 Series User manual

Venture Measurement

Venture Measurement Genuine Bindicator VRF-2000 Series User manual

Popular Accessories manuals by other brands

nedis WIFIP130FWT3 quick start guide

nedis

nedis WIFIP130FWT3 quick start guide

WD Plus BEARWARE 303492/20181211FS025 manual

WD Plus

WD Plus BEARWARE 303492/20181211FS025 manual

Chamberlain Secure Home SH-9525AU Installation and operating instructions

Chamberlain

Chamberlain Secure Home SH-9525AU Installation and operating instructions

Denver VDB-216 user manual

Denver

Denver VDB-216 user manual

SOMFY 6301051 installation instructions

SOMFY

SOMFY 6301051 installation instructions

IFM Electronic efector 250 O2D2 Series Programming manual

IFM Electronic

IFM Electronic efector 250 O2D2 Series Programming manual

GTV CR-CO1000-00 instructions

GTV

GTV CR-CO1000-00 instructions

Moleskine PenPlus Ellipse NWP-F70 user manual

Moleskine

Moleskine PenPlus Ellipse NWP-F70 user manual

Baumer OADM 20I6460/S14F manual

Baumer

Baumer OADM 20I6460/S14F manual

STEINEL SensorSchalter IR 180 UP operating instructions

STEINEL

STEINEL SensorSchalter IR 180 UP operating instructions

McIntosh LB100 Operation guide

McIntosh

McIntosh LB100 Operation guide

Red Arrow Trading PIR-B1 instructions

Red Arrow Trading

Red Arrow Trading PIR-B1 instructions

Awntech RF22 Owner's Manual & Installation Instructions

Awntech

Awntech RF22 Owner's Manual & Installation Instructions

ML Knightsbridge SK005 Installation & maintenance manual

ML

ML Knightsbridge SK005 Installation & maintenance manual

SICK GRL18V Operating	 instruction

SICK

SICK GRL18V Operating instruction

esera DS18S20 user guide

esera

esera DS18S20 user guide

SICK GSE6L Series operating instructions

SICK

SICK GSE6L Series operating instructions

M-system M8BS-1-1 instruction manual

M-system

M-system M8BS-1-1 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.