Verano VER-15 User manual

User’s manual VER-15
2016-01

User’s manual
2

VER-15
3
Table of contents
I. Safety...................................................................................................................... 4
II. Description of the device ......................................................................................... 5
III. Installation ............................................................................................................ 5
III.a) Connection diagram ............................................................................................. 6
IV. First start-up ......................................................................................................... 7
V. How to use the controller ........................................................................................... 7
V.a) Principle of operation ............................................................................................. 7
V.b) Operation modes ................................................................................................... 7
V.b) Main screen view and description .......................................................................... 10
V.c) Controller functions.............................................................................................. 12
V.c.1) Block diagram –main menu ............................................................................ 12
V.c.2) Day of the week ............................................................................................ 13
VII.c.3) Time settings .............................................................................................. 13
VII.c.4) Day from….................................................................................................. 13
VII.c.5) Night from…................................................................................................ 13
V.c.6) Optimum start ............................................................................................... 14
V.c.7) Service menu ................................................................................................ 14
V.c.8) Weekly control............................................................................................... 15
V.c.9) Pre-set comfort temperature ........................................................................... 17
VII.c.14) Pre-set economical temperature .................................................................. 17
VII.c.15) Pre-set temperature hysteresis.................................................................... 17
VII.c.16) Temperature sensor calibration ................................................................... 18
VI. Technical data ..................................................................................................... 18

User’s manual
4
I. Safety
Before using the device for the first time the user should read the following regulations carefully.
Not obeying the rules included in this manual may lead to personal injuries or controller damage.
The user’s manual should be stored in a safe place for further reference. In order to avoid
accidents and errors it should be ensured that every person using the device has familiarized
themselves with the principle of operation as well as security functions of the controller. If the
device is to be sold or put in a different place, make sure that the user’s manual is there with the
device so that any potential user has access to essential information about the device.
The manufacturer does not accept responsibility for any injuries or damage resulting from
negligence; therefore, users are obliged to take the necessary safety measures listed in this
manual to protect their lives and property.
WARNING
The device should be installed by a qualified electrician.
The regulator should not be operated by children.
WARNING
Any use other than specified by the manufacturer is forbidden.
Before and during the heating season, the controller should be checked for condition of its
cables. The user should also check if the controller is properly mounted and clean it if dusty
or dirty.
Care for the natural environment is our priority. Being aware of the fact that
we manufacture electronic devices obligates us to dispose of used elements
and electronic equipment in a manner which is safe for nature. As a result,
the company has received a registry number assigned by the Main Inspector
of Environmental Protection. The symbol of a crossed out rubbish bin on a
product means that the product must not be thrown out to ordinary waste
bins. By segregating waste intended for recycling, we help protect the natural
environment. It is the user's responsibility to transfer waste electrical and
electronic equipment to the selected collection point for recycling of waste
generated from electronic and electrical equipment.

VER-15
5
II. Description of the device
VER-15 room regulator is intended for controlling the heating or cooling device (e.g. gas, oil or
electric furnace or the CH boiler controller). Its main task is to maintain the pre-set temperature in
the flat by sending a signal to the heating/cooling device (contact opening) when the desired
temperature is reached.
Advanced software enables the regulator to fulfil a wide range of functions:
maintaining the pre-set room temperature
manual mode
day/night program
weekly control
control of the underfloor heating system (optional; an additional temperature sensor is
necessary)
Controller equipment:
touch buttons
front panel made of 3mm glass
built-in temperature sensor
batteries
III. Installation
The controller should be installed by a qualified person.

User’s manual
6
VER-15 controller may be installed as a panel mountable on the wall.
III.a) Connection diagram
Room regulator should be connected with actuator with two-wired cable.
Connection of both devices is shown on a diagram below:
ATTENTION:
Marking on the back of the controller refers to bulit-in relay.
Marking do not describe the type of connected actuator.

VER-15
7
ATTENTION:
Regulator is powered by batteries - it is necessary to check the batteries state
periodically.
Batteries should be changed at least once during a season.
To provide proper operation of control circuit, it is necessary to supply 230V AC to
regulator - according to diagram below.
IV. First start-up
In order for the controller to operate correctly, the user must follow these steps when starting the
device for the first time:
1. Remove the front cover of the controller and insert the batteries.
2. In the case of VER-15 connect the two-core cable to appropriate sockets in the receiver.
V. How to use the controller
V.a) Principle of operation
VER-15 room regulator is designed to maintain desired room temperature by sending signal to
actuator (contact closure) with information about necessity of heating.
After receiving that signal actuator unlocks flow on thermostatic valve.
V.b) Operation modes
The user has three operation modes to choose from:

User’s manual
8
Day/night mode
In this mode the pre-set temperature value depends on the current time of the day. The user may
set different temperature values for the daytime and nighttime (comfort temperature and
economical temperature) as well as define the exact time of entering day mode and night mode.
In order to activate this mode, press EXIT button until day/night mode icon appears on the main
screen.
Weekly control
This mode enables the user to define the time when the pre-set comfort temperature and the pre-
set economical temperature will apply. The user may set 9 different programs divided into three
groups:
- programs 1÷3 –daily temperature values are set for all days of the week;
- programs 4÷6 –daily temperature values are set separately for the weekdays (Monday-Friday)
and for the weekend (Saturday-Sunday);
- programs 7÷9 –daily temperature values are set for each day of the week separately.
* The display shows the hours when the comfort temperature applies. In the remaining time
period economical temperature applies.
In order to activate this mode, press and hold EXIT button until the weekly control icon appears
on the main screen.
Day/night
mode icon
Weekly control
icon
Number of the
current weekly
control program
Parameters of the
current weekly
control program*

VER-15
9
Manual mode
In this mode the pre-set temperature is adjusted manually from the main screen view with the
use of these buttons: or . Manual mode is activated when one of these buttons is pressed.
When the manual mode is activated, the previous operation mode enters ‘sleep mode’ until the
next pre-programmed temperature change. Manual mode may be deactivated by pressing EXIT
button.
Example 1 –manual mode activation in Day/night mode
When Day/night mode is active, the user changes the pre-set temperature by pressing or
which automatically activates manual mode.
The controller returns to Day/night mode when daytime changes into nighttime (or the other way
round) or when the user presses EXIT button.
Example 2 –manual mode activation in weekly control mode
When weekly control is active, the user changes the pre-set temperature by pressing or ,
which automatically activates manual mode.
The controller returns to weekly control mode when, according to the weekly schedule, economical
temperature changes into comfort temperature (or the other way round) or when the user presses
EXIT button.
Manual mode
icon
Manual mode
icon

User’s manual
10
V.b) Main screen view and description
The user operates the device using buttons. While one parameter is being edited, the remaining
icons are not displayed.
1. Display
2. EXIT - pressing this button in the main screen view activates weekly control mode or
day/night mode. After entering the menu, this button is used to confirm the settings and
return to the main screen view.
3. Minus button ( ) –pressing this button in the main screen view activates manual mode
and decreases the pre-set temperature. After entering the menu, this button is used to
adjust parameters, enter the service code etc.
4. Plus button ( ) –pressing this button in the main screen view activates manual mode
and increases the pre-set temperature. After entering the menu, this button is used to
adjust parameters, enter the service code etc.
5. MENU button –hold this button in order to enter the controller menu. While editing
parameters press this button to confirm the changes and move on to edit the next
parameter.
1
2
3
5
4

VER-15
11
1. Current operation mode:
a. weekly
b. manual
c. day/night
2. Current temperature of the room
3. Parameters icons (see: table below)
4. Icon indicating economical temperature (according to weekly control or day/night
settings)
5. Icon indicating comfort temperature (according to weekly control or day/night settings)
6. Day of the week
7. Pre-set temperature of the room
8. Time
9. Battery level
10. Temperature information (depending on the current operation mode):
oheating mode - the icon is flashing when the pre-set temperature of the room has
not been reached and it is steady when the pre-set temperature has been reached.
ocooling mode –the icon is moving when the room temperature is above the pre-
set value and it is steady when the pre-set temperature has been reached.
1
2
3
3
4
5
6
7
8
9
10

User’s manual
12
Parameters icons:
Time settings
Weekly control settings
Day from…
Comfort temperature
Night from…
Economical temperature
Optimum start / heating-
cooling mode selection (in
service menu)
Hysteresis
Enter service menu / zone
selection (EU-292v4)
Temperature sensor calibration
Channel selection
V.c) Controller functions
The user navigates the menu structure using , , EXIT and MENU. In order to edit particular
parameters, press MENU. Next, press MENU to view the controller functions –the edited
parameter is flashing whereas the remaining parameters are not displayed. Use or to
change the parameter settings. Press MENU to confirm the changes and move on to edit the next
parameter or press EXIT to confirm the changes and return to the main screen view.
V.c.1) Block diagram –main menu
Main menu
Day of the week
Time settings
Day from...
Night from...
Optimum start
Service menu Heating / cooling mode
Weekly control
Pre-set comfort temperature
Pre-set economical temperature
Hysteresis
Temperature sensor calibration

VER-15
13
V.c.2) Day of the week
After entering the main menu, all icons which are
not connected with the parameter which is being
edited are not displayed. The first parameter is
day of the week.
Press or until the current day of the week
is displayed. Press MENU to confirm and move on
to the next parameter or press EXIT to confirm
and return to the main screen view.
VII.c.3) Time settings
In order to set current time, press MENU until
time setting panel is displayed on the screen.
By pressing or set the hour and minutes.
Press MENU to confirm and move on to the next
parameter or press EXIT to confirm and return to
the main screen view.
VII.c.4) Day from…
This function enables the user to define the exact
time of entering the day mode. When Day/night
mode is active, comfort temperature applies at
daytime.
To configure this parameter press MENU until Day
from… setting appears on the screen.
By pressing or set the hour and minute of
day mode activation.
Press MENU to confirm and move on to the next
parameter or EXIT to confirm and return to the
main screen view
VII.c.5) Night from…
This function enables the user to define the exact
time of entering the night mode. When Day/night
mode is active, economical temperature applies
at nighttime.
To configure this parameter press MENU until
Night from… setting appears on the screen.
By pressing or set the hour and minute of
night mode activation.
Press MENU to confirm and move on to the next
parameter or press EXIT to confirm and return to
the main screen view.

User’s manual
14
V.c.6) Optimum start
Optimum start is an intelligent system controlling the heating/cooling process. It involves constant
monitoring of the heating/cooling system efficiency and using the information to activate the
heating/cooling process in advance in order to reach the pre-set temperatures.
The system requires no user intervention. It precisely reacts to any changes that affect
the efficiency of the heating system. If, for example, some changes have been introduced to the
heating system and the house heats up faster than before, the Optimum start system will
recognize the changes at the next pre-programmed temperature change (from comfort to
economical) and in the next cycle the heating system activation will be adequately delayed,
reducing the time needed to reach the desired temperature.
A–pre-programmed change from economical temperature to comfort temperature
Activating this function means that at the time of pre-programmed change of the pre-set
temperature from comfort to economical or the other way round, the current room temperature
is close to the desired value.
In order to configure this parameter, press MENU
until Optimum start setting panel appears on the
screen.
Use or to activate or deactivate Optimum
start function. Press MENU to confirm and move on
to edit the next parameter or press EXIT to confirm
and return to the main screen view.
V.c.7) Service menu
Certain functions in the controller service menu are
secured with a code. In order to adjust their
parameters, press MENU until Service menu
settings appear on the screen.
To view the service menu it is necessary to enter
the code –215. Use or to select the first
digit (2) and confirm by pressing and holding
MENU until the next digit starts flasihing. Follow
the same steps selecting the remaining two digits.
Room temperature -
OPTIMUM START switched on:
Room temperature -
OPTIMUM START switched off:

VER-15
15
Heating/cooling mode
This function enables the user to select the room
regulator operation mode:
- controlling the cooling system
- controlling the heating system
Press or to select desired type of system.
Press MENU to confirm and move on to edit
another parameter in the service menu or press EXIT to confirm to return to the main screen
view.
V.c.8) Weekly control
This function is used to change the current weekly control program and edit the weekly programs.
How to change the current weekly program number
When weekly control is enabled (see: V.b Operation
modes) the current program is activated. In order
to choose the program number, press MENU until
weekly program setting appears on the screen.
By pressing and holding MENU button the user
opens the program selection panel. Each time the
user holds the MENU button, the program number
changes. When the desired number appears on the
screen, press EXIT –the controller returns to the
main screen view and the selected program number
is set.
How to configure particular weekly programs
Weekly program allows the user to define the time when
comfort temperature and economical temperature will
apply. Depending on the program number, the user may
set daily temperature values for all days of the week
(programs 1÷3), for weekdays and the weekend
separately (programs 4÷6) and for each day of the week
separately (programs 7÷9).
In order to edit weekly program, press MENU until weekly
program setting panel appears on the screen.
STEP 1 –choose the program to be edited:
By pressing and holding MENU button the user opens the program editing panel. Each time the
user holds the MENU button, the program number changes. When the desired number appears
on the screen, the user may start editing its parameters.
Weekly program
number

User’s manual
16
Step 2 –select days of the week
If the user wants to edit programs 1÷3, there is no possibility of selecting particular days of the
week as the setting applies to each day.
If the user wants to edit programs 4÷6 , it is possible to edit the settings for weekdays and the
weekend separately. Press MENU in order to select.
If the user wants to edit programs 7÷9, it is possible to edit the settings for each day separately.
Press MENU in order to select a day.
Step 3 –assign comfort temperature or economical temperature to particular hours
An hour which is being edited is displayed on the controller screen. In order to assign comfort
temperature, press . In order to select economical temperature, press . The controller
automatically moves on to editing the next hour.
Weekly program
number
Editing
weekdays
parameters
Editing
parameters for
Monday
Edited hour

VER-15
17
The parameters of the weekly program are displayed at the bottom of the screen: hours to which
comfort temperature has been assigned are displayed whereas hours to which economical
temperature has been assigned are not displayed.
Example:
The following screenshot presents daily settings of
program no. 7 for Monday
24⁰⁰-01⁵⁹- economical temperature
02⁰⁰-06⁵⁹- comfort temperature
07⁰⁰-14⁵⁹- economical temperature
15⁰⁰-21⁵⁹- comfort temperature
22⁰⁰-00⁵⁹- economical temperature
NOTE
When the user finishes the editing process by pressing and holding MENU button, the
controller returns to the main screen view and this program is selected as the current
program.
V.c.9) Pre-set comfort temperature
Pre-set comfort temperature is used in weekly
control mode and day/night mode. Press MENU
button until the comfort temperature change panel
appears on the screen.
Press or to set the desired temperature.
Press MENU to confirm and move on to the next
parameter or press EXIT to confirm and return to
the main screen view.
VII.c.14) Pre-set economical temperature
Pre-set economical temperature is used in weekly
control mode and day/night mode. Press MENU
button until the economical temperature change
panel appears on the screen.
Press or to set the desired temperature.
Press MENU to confirm and move on to the next
parameter or press EXIT to confirm and return to the
main screen view.
VII.c.15) Pre-set temperature hysteresis
Room temperature hysteresis defines the pre-set
temperature tolerance in order to prevent undesired
oscillation in case of small temperature fluctuation
(within the range of 0,2 ÷ 4°C).

User’s manual
18
Example:
Pre-set temperature: 23°C
Hysteresis: 1°C
The room regulator reports that the temperature is too low only when the room temperature drops
to 22 °C.
In order to set the hysteresis, press MENU until the hysteresis setting appears on the screen.
Use or to set the desired hysteresis value. Press MENU to confirm and move on to the next
parameter or press EXIT to confirm and return to the main screen view.
VII.c.16) Temperature sensor calibration
It is performed when mounting the regulator or after it has been used for a long time, if the room
temperature measured by the internal sensor differs
from the actual temperature. Calibration setting
range is from -10°C to +10°C with the accuracy of
0,1°C.
Press MENU until the sensor calibration panel
appears on the screen. Use or to define
correction. Press MENU to confirm and move on to
edit the next parameter or press MENU to confirm
and return to the main screen view.
VI. Technical data
Range of room temperature settings
5oC : 35oC
Supply voltage
Batteries 2xAA, 1,5V
Accuracy of measurement
+/- 1oC
Contact load
1A/230V/50Hz
Operating temperature
5oC : 50oC

VER-15
19

User’s manual
20
Table of contents
Popular Controllers manuals by other brands

Advantech
Advantech UNO-127 user manual

Siemens
Siemens Simatic S7-300 Reference manual

Xilinx
Xilinx Zynq-7000 Design guide

Larson Electronics
Larson Electronics PTB-1-M-30C-4C instruction manual

Oceanled
Oceanled OCEANDMX EXPLORE Series Install & Operation Manual

Tech Works
Tech Works ICM-8C Operation and installation manual