Verilink DIU 2131 User manual

Verilink DIU 2131High-Low
Module User Manual
September 1999
P/N 880-502765-001-D1
2131
DIU
LOOP
LOOP
STAT
DATA
PORT 1
NEAR
END FAR
END
LOOP
LOOP
STAT
DATA
PORT 2
NEAR
END FAR
END

ii Verilink DIU 2131 User Manual
Copyright Notice Copyright 1999 Verilink Corporation. All rights reserved.
This document does not create any express or implied warranty about Verilink or about
its products or services. Verilink’s sole warranty is contained in its product warranty.
The end-user documentation is shipped with Verilink’s products and constitutes the
sole specifications referred to in the product warranty. Verilink has made reasonable
efforts to verify that the information contained herein is accurate, but Verilink assumes
no responsibility for its use or for any infringement of patents or other rights of third
parties that may result. The customer is solely responsible for verifying the suitability of
Verilink’s products for its use. Specifications are subject to change without notice.
Trademarks Verilink is a registered trademark of Verilink Corporation. Access System 2000,
WANscope, VeriStats, and FrameStart are trademarks of Verilink Corporation.
Any named products herein are trademarks of their respective companies.
FCC Requirements This equipment has been tested and found to comply within the limits for a Class A
digital device pursuant to Part 15 of the Federal Communications Commission (FCC)
rules. These limits are designed to provide protection against harmful interference in a
commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the user manual, can cause harmful interference
to radio communications.
There is no guarantee that interference will not occur in a particular installation. If this
equipment causes harmful interference to radio or television reception—which can be
determined by turning the equipment off and on—try to correct the interference by one
or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with Part 68 of the FCC Rules. On the rear, side or bottom of
the unit is a label that contains the FCC registration number and other information. If
requested, provide this information to the telephone company.
•All direct connections to the network lines must be made using standard plugs
and jacks (compliant with Part 68). The following tables list the applicable
registration jack universal order codes (USOCs), facility interface codes (FICs), and
service order codes (SOCs). These are required to order service from the telco.
For T1 interfaces:
For DDS interfaces:
•If the unit appears to be malfunctioning, inform the telco and disconnect it from
the network lines until the source of trouble is determined to be your equipment
or the telephone line . If your equipment needs repair, it should not be
reconnected until it is repaired.
•The unit has been designed to prevent harm to the network. If the telephone
company finds that the equipment is exceeding tolerable parameters, it can
temporarily disconnect service. In this case, the telephone company will provide
you advance notice if possible.
Port ID REN/SOC FIC USOC
1.544 Mbit/s SF
1.544 Mbit/s SF, B8ZS
1.544 Mbit/s ANSI ESF
1.544 Mbit/s ANSI ESF, B8ZS
6.0N 04DU9 -BN
04DU9 -DN
04DU9 -1KN
04DU9 -1SN
RJ-48C jack
Port ID REN/SOC FIC USOC
56 kbit/s
64 kbit/s 6.0N 04DU5 -56
04DU5 - 64 RJ-48S jack

Verilink DIU 2131 User Manual iii
•If the telephone company alters its equipment in a manner that can affect the use
of this device, it must give you warning so that you have the opportunity to
maintain uninterrupted service. You will be advised of your right to file a
complaint with the FCC.
•No customer is authorized to repair this equipment, regardless of warranty
status. All repairs must be performed by Verilink or an authorized agent. It is the
responsibility of users requiring service to report the need for service to Verilink
or to one of our authorized agents.
Lithium Battery The lithium battery referred to in the following notices is contained inside the clock
chip.
English DANGER!
The battery can explode if incorrectly replaced! Replace only with the same or equiv-
alent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturer’s instructions.
DANGER!
To avoid electrical shock in case of failure, the power supply must be installed by a
professional installer. The terminal labeled with the ground symbol ( ) on the
power supply must be connected to a permanent earth ground.
CAUTION!
Interconnecting circuits must comply with the requirements of
EN60950:1992/A4:1997 Section 6.2 for telecommunications network voltages (TNV)
circuits.
Français ATTENTION!
Une explosion peut se produire si la batterie est remplacée d’ une façon incorrecte!
Remplacez-la seulement avec le même modêle de batterie ou un modèle équivalent
selon les recommendations de manufacture. Disposez de les batteries usées selon les
instructions de manufacture.
ATTENTION!
Pour éviter choc électrique en cas de insuccès, la provision de pouvoir doit êtré
installé par un installeur professionnel. Le terminal de la provision de pouvoir, mar-
qué du symbol de terre, ( ) doit connecté à un circuit de terre permanent.
PRUDENT!
Les circuits doivent êtré interconnectés de manière à ce que l’ équipement continue a
êtré en agrément avec “EN60950:1992/A4:1997, Section 6.2, pour les circuits de
voltage de liaisons d’ échanges (réseau) par les télécommunications (TNV),” après les
connections de circuits.
Españole ATTENCION!
La bateria puede explotar si se reemplaza incorrectamente. Reemplace la bateria con
el mismo tipo de bateria ó una equivalente recomendada por el manufacturero. Dis-
ponga de las baterias de acuerdo con las instrucciones del manufacturero.
ATTENCION!
Para evitar contacto con circuitos que electrocutan, la fuente de alimentación debe
ser instalada por un técnico profesional. La terminal de la fuente de alimentación
marcada con el símbolo de tierra ( ) debe ser conectada a un circuito de vuelta por
tierra permanente.
PELIGRO!
Circuitos que se interconectan a la red de telecomunicaciones deben hacerse de tal
manera que cumplan con los requisitos estipulados en las especificaciones
“EN60950:1992/A4:1997, Sección 6.2, para los voltages de circuitos interconnectados
a la Red de Telecomunicaciones (TNV),” despues de terminar las connecciones entre
los circuitos.

iv Verilink DIU 2131 User Manual
Deutsch VORSICHT!
Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs
und gleicher Qualität benutzen, wie vom Hersteller empfohlen. Entsorgung der Batte-
rie nach Anweisung des Herstellers!
VORSICHT, GEFAHR!
Um keinen Schlag zu erhalten beim Versagen der electrischen Anlage, muss der Stro-
manschluss von einem Elektriker vorgenommen werden. Der elektrische Pol, verse-
hen mit dem Erdsymbol ( ) muss am Stromanschluss permanent geerdet sein.
VORSICHT!
Schaltungen, die in den Geräten zusammengeschaltet sind, müssen weiterhin den
Vorschriften EN60950:1992/A4:1997, Absatz 6.2 für Telecommunications Netz
Spannung (TNV) Schaltkreize entsprechen.
Canadian
Requirements This digital apparatus does not exceed the Class A limits for radio noise emissions from
digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les
limites applicables aux appareils numériques (de la class A) prescrites dans le
Règlement sur le brouillage radioélectrique édicté par le ministère des Communications
du Canada.
The Industry Canada label indentifies CS-03 certified equipment. This certification
means that the equipment meets certain telecommunications network protective,
operational and safety requirements. Industry Canada does not guarantee the
equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The equipment
must also be installed using an acceptable method of connection. In some cases, the
company’s inside wiring associated with a single line individual service may be extended
by means of a certified connector assembly (telephone extension cord). The customer
should be aware that compliance with the above conditions may not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance
facility designated by the supplier. Any repairs or alterations made by the user to this
equipment, or equipment malfunctions, may give the telecommunications company
cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of
the power utility, telephone lines and internal metallic water pipe system, if present, are
connected together. This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should
contact the appropriate electric inspection authority, or electrician, as appropriate.
Safety Precautions This equipment is intended to be installed only in a Restricted Access Location that
meets the following criteria:
•Access can only be gained by service personnel or users who have been instructed
about the reasons for the restrictions applied to the location and about any
precautions that must be taken.
•Access can only be gained through the use of a lock and key or other means of
security, and is controlled by the authority responsible for the location.
When handling this equipment, follow these basic safety precautions to reduce the risk
of electric shock and injury:
•Follow all warnings and instructions marked on the product and in the manual.
•Unplug the hardware from the wall outlet before cleaning. Do not use liquid
cleaners or aerosol cleaners. Use a cloth slightly dampened with water.
•Do not place this product on an unstable cart, stand, or table. It may fall, causing
serious damage to the product.
•Slots and openings in the shelves are provided for ventilation to protect them
from overheating. These openings must not be blocked or covered. Never place
this product near a radiator or heat register.

Verilink DIU 2131 User Manual v
•This product should be operated only from the type of power source indicated on
the marking label and manual. If you are unsure of the type of power supply you
are using, consult your dealer or local power company.
•Do not allow anything to rest on the power cord. Do not locate this product where
the cord will interfere with the free movement of people.
•Do not overload wall outlets and extension cords, as this can result in fire or
electric shock.
•Never push objects of any kind into the shelves. They may touch dangerous
voltage points or short out parts that could result in fire or electric shock. Never
spill liquid of any kind on this equipment.
•Unplug the equipment from the wall outlet and refer servicing to qualified service
personnel under the following conditions:
• When the power supply cord or plug is damaged or frayed.
• If liquid has been spilled into the product.
• If the product has been exposed to rain or water.
• If the product has been dropped or if the cabinet has been damaged.
Product Warranty Verilink’s product warranty covers repair or replacement of all equipment under normal
use for a five-year period from date of shipment. Replacement products may be new or
reconditioned. Any replaced or repaired product or part has a ninety (90) day warranty
or the remainder of the initial warranty period, whichever is longer. Our in-house Repair
Center services returns within ten working days.
Customer Service Verilink offers the following services:
•System Engineers at regional sales offices for network design and planning
assistance (800) 837-4546
•Technical Assistance Center for free 24x7 telephone support during installation,
maintenance, and troubleshooting (800) 285-2755 and support@verilink.com)
•To return a product, it must be assigned a Return Materials Authorization (RMA)
number before sending it to Verilink for repair (800) 926-0085, ext. 2282
•Maintenance contracts and leasing plans (800) 837-4546
•Technical Training on network concepts and Verilink products (800) 282-2755
•Web site (www.verilink.com)
Publications Staff This manual was written and illustrated by Laine Tammer. Contributing Writers and
Editors: David Gardner, Marie Metivier, Barbara Termaat, and Steve Rider.

vi Verilink DIU 2131 User Manual

Table of Contents
Verilink User Guide vii
1 High-Low Application ......................................................................................1-1
Overview .......................................................................................................1-1
Network Management ..........................................................................1-2
2 Quick Set-up .....................................................................................................2-1
Sample Application ......................................................................................2-1
Physical Configuration .................................................................................2-2
Software Configuration ................................................................................2-2
Logging on ...........................................................................................2-3
SCC 2020 ..............................................................................................2-3
DIU 2131 ..............................................................................................2-3
3 Configuration Menu .........................................................................................3-1
Pre-requisites ...............................................................................................3-1
Configuring the DIU 2131 ............................................................................3-1
Menu Layout ........................................................................................3-2
Assigning the DIU to a CSU .................................................................3-2
Setting DIU up for Multiplexing ..........................................................3-3
Summary of Commands ......................................................................3-4
4 Diagnostics and Troubleshooting ...................................................................4-1
DIU 2131 Front Panel ...................................................................................4-1
Near End Loop LED ..............................................................................4-1
Far End Loop LED ................................................................................4-1
STAT LED .............................................................................................4-1
Monitoring Test Pattern Errors ...........................................................4-3
Monitoring Leads and Status ..............................................................4-4
A Specifications ...................................................................................................................A-1

viii Verilink User Guide

Verilink User Manual 1-1
Chapter
1High-Low Application
This user manual describes the DIU 2131 High-Low module within
Verilink’s Access System 2000 (AS2000) platform. This module
operates in conjunction with a CSU—either an SCC 2020, TAC 2010
or DIDCSU 2912—to multiplex a high-speed and low-speed
application onto a single T1. The latest firmware revisions, SCC
2.06 and TAC 1.6, enable the user to configure all of the modules at
the far end node, not just the controller. Passwords are used to
control access between the near and far ends.
NOTE: This manual requires familiarity with standard
telecommunications terminology, applications, and practices.
Overview
The High-Low module multiplexes up to 24 channels from two
synchronous ports—one high-speed for aggregating multiple data
channels and one low-speed for subrate data—and transfers the
information onto a single T1 line.
There are two data ports on the DIU 2131 rear connector module,
the HLM 2532:
•Port 1 is a high-speed V.35 synchronous port, providing n ×56
(default) or n ×64 kbit/s of bandwidth.
•Port 2 is a low-speed RS-232 synchronous port using a single
DS0, providing speeds of 2.4, 4.8, 9.6, 19.2, 28.8, 38.4, 56, or
64 kbit/s.
The front modules and their rear connector modules are shown in
the figures below.

High-Low Application
1-2 Verilink User Manual
Figure 1-1 DIU 2131 Front Panel with HLM 2532
Network
Management The DIU 2131 can be in a node controlled by an SCC or NCM
controller module. These controllers can be managed by the Craft
interface, SNMP or Node Manager. Remotely located users can also
use Telnet over Ethernet or SLIP to access the Craft interface. See
the user manual for the controller in your node.
2131
DIU
LOOP
LOOP
STAT
311-101860-001
RS232
HLM
2532
DIU 2131 Application Module
HLM 2532 Interface Module
DATA PORT 2 DATA PORT 1V.35
DATA
PORT 1
NEAR
END FAR
END
LOOP
LOOP
STAT
DAT
PORT 2
NEAR
END FAR
END

Verilink User Manual 2-1
Chapter
2Quick Set-up
The DIU 2131 multiplexes data from a high-speed and low-speed
application onto a shared T1 line. The high-speed application could
be a file server, router, bridge, video teleconference codec, or any
device with a synchronous connection. The low-speed application
can be up to 64 kbit/s, or one T1 timeslot. A typical application is
an automatic teller machine.
This chapter describes all of the steps required to set up the DIU
2131 for a typical application. Your settings may be different, for
example the number of timeslots needed for your high-speed
application.
Refer to the appropriate controller module and management
software user manuals for more detailed information. This chapter
focuses on the DIU 2131 configuration.
Sample Application
The DIU 2131 is ideally suited to provide connectivity between
branch offices and data processing hubs within the banking
industry.
Figure 2-1 Sample Application
We will use the above application for the quick setup procedure,
using the following parameters:
Branch Bank
Data Processing Hub
SCC 2020 DIU 2131
HLM 2532CIM
DLS 2100
Shelf
V.35
RS-232 Synch
Router Port
Automatic
Teller
Machines
(ATMs)
AS2000
SCC 2020DIU 2131
HLM 2532 CIM
MLS 2200
Shelf
AS2000
RS-232 Synch
19.2 kbps
V.35
ATM Machine
Front End
Frame Relay
Port
Network Management
Workstation
LAN Traffic: nx64K
T1
LAN Router and
ATM MachineTraffic
Processor

Quick Set-up
2-2 Verilink User Manual
•DS0 1 is for a low-speed teller application connected to the
Port 2, RS-232 connector.
•DS0s 2-5 are for a 220 kbit/s router connected to the Port 1,
V.35 connector.
•The T1 has ESF framing and B8ZS line coding.
•The DIU 2131 is sending data to the T1 port on an SCC 2020 in
a Dual-line shelf.
•We are accessing the DIU 2131 via a terminal emulator
connected to the Craft port on the SCC 2020.
•The information is passing to the SCC 2020 using Data Bus A
(could also be Data Bus B or C).
•The network is providing the master clock.
Physical Configuration
The following steps are required at both ends of the point-to-point
connection before configuring the firmware.
1. Put the rear connector module in first. Slide the SCC 2020 into
slot 1 of the shelf and the DIU 2131 into slot 2.
2. Connect the router to the V.35 port and the ATM to the RS-232
port. Connect the T1 to the Network port.
3. Power up the shelf.
4. Put the Craft cable from your ASCII terminal emulator to the
Craft port on the SCC.
5. Set the terminal communication parameters to:
19,200 kbit/s
8 bits
No parity
1 stop bit
Flow control = none
Software Configuration
This section provides the steps required to configure the SCC 2020
and DIU 2131 for our sample application. Only changes required to
the default settings are noted.

Quick Set-up
Verilink User Manual 2-3
Logging on Type “craft” at the pSH+> prompt. Press ENTER at the YOUR
PASSWORD? prompt.
SCC 2020 We are not going into detail about how to configure the SCC 2020
for our example. We just need to make sure that the T1 framing and
line coding, and the data bus mode are set correctly.
1. Set the framing to ESF-ESF.
2. Set the line coding format to B8ZS-B8ZS and the timing to
“recovered”.
3. Set
4. Choose DIU Data Bus A.
The completed SCC Configuration Menu is shown below.
DIU 2131 After configuring a CSU, you can configure each associated DIU for
operation with that CSU. Configuration and diagnostics for the
DIU 2131 are located on the same menu.
From the Main Menu, access this screen by using the Shelf, Slot
option selecting the module and then entering Cfor configuration.
Figure 5-2 shows the resulting menu.
Figure 2-2 DIU 2131 Configuration/Diagnostic Menu
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ------ DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
C) CSU [ 1,1 ]
C) CSU [ 1,1 ]C) CSU [ 1,1 ]
C) CSU [ 1,1 ]
T) timing source CSU
T) timing source CSUT) timing source CSU
T) timing source CSU
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..
Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..
Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..
Lead Toggles DTR) DSR) RTS) CTS) DCD)
Lead Toggles DTR) DSR) RTS) CTS) DCD)Lead Toggles DTR) DSR) RTS) CTS) DCD)
Lead Toggles DTR) DSR) RTS) CTS) DCD)
Forced Ports -/- -/- -/- -/- -/-
Forced Ports -/- -/- -/- -/- -/-Forced Ports -/- -/- -/- -/- -/-
Forced Ports -/- -/- -/- -/- -/-
Port 1 Port 2 Statistics
Port 1 Port 2 StatisticsPort 1 Port 2 Statistics
Port 1 Port 2 Statistics
Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8
Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8
Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8
Sp) scram/hdlc inv N/N N/N Battery.....OK
Sp) scram/hdlc inv N/N N/N Battery.....OKSp) scram/hdlc inv N/N N/N Battery.....OK
Sp) scram/hdlc inv N/N N/N Battery.....OK
Kp) clocking ST ST DTE Intf....V.35/RS-232
Kp) clocking ST ST DTE Intf....V.35/RS-232Kp) clocking ST ST DTE Intf....V.35/RS-232
Kp) clocking ST ST DTE Intf....V.35/RS-232
Gp) LOS lead NONE NONE Data bus....A
Gp) LOS lead NONE NONE Data bus....AGp) LOS lead NONE NONE Data bus....A
Gp) LOS lead NONE NONE Data bus....A
Ep) enable loop YES YES Tp) test and monitor BEC
Ep) enable loop YES YES Tp) test and monitor BECEp) enable loop YES YES Tp) test and monitor BEC
Ep) enable loop YES YES Tp) test and monitor BEC
Np) near loopback OFF OFF Pp) monitor leads and status
Np) near loopback OFF OFF Pp) monitor leads and statusNp) near loopback OFF OFF Pp) monitor leads and status
Np) near loopback OFF OFF Pp) monitor leads and status
Fp) far loopback OFF OFF A) Alarm Enable......NO
Fp) far loopback OFF OFF A) Alarm Enable......NOFp) far loopback OFF OFF A) Alarm Enable......NO
Fp) far loopback OFF OFF A) Alarm Enable......NO
[1,2] DIU 2131 >
[1,2] DIU 2131 >[1,2] DIU 2131 >
[1,2] DIU 2131 >

Quick Set-up
2-4 Verilink User Manual
Assigning
Timeslots 1. Type “D1” to assign DS0s for Port 1.
2. Type “2-5”.
3. Type “D2” to assign the DS0 for Port 2.
4. Type “1”.
Assign Mode Since we are using ESF, we have 64 kbit/s available in each timeslot.
5. Type “M2” and select 19.2 kbit/s.

Verilink User Manual 3-1
Chapter
3Configuration Menu
This chapter describes all of the options and settings included in
the Configuration/Diagnostic Menu.
Pre-requisites
Before configuring the DIU 2131, the associated CSU must be
configured for Mux mode. This is done using the DIU bus option in
the CSU’s Configuration Menu to choose Data Bus A, B or C. See the
CSU manual for more information, either the SCC 2020 User Manual
or the TAC 2010 User Manual.
Configuring the DIU 2131
After configuring the CSU, you can configure each associated DIU.
From the Main Menu, use the Shelf/slot option to select the DIU
2131 and then enter “C” for configuration. Figure 5-1 shows the
resulting menu.
Figure 3-1 DIU 2131 Configuration/Diagnostic Menu
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ------ DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
C) CSU [ 1,1 ]
C) CSU [ 1,1 ]C) CSU [ 1,1 ]
C) CSU [ 1,1 ]
T) timing source CSU
T) timing source CSUT) timing source CSU
T) timing source CSU
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Dp)port 02 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Dp)port 02 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..Dp)port 02 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Dp)port 02 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Lead Toggles DTR) DSR) RTS) CTS) DCD)
Lead Toggles DTR) DSR) RTS) CTS) DCD)Lead Toggles DTR) DSR) RTS) CTS) DCD)
Lead Toggles DTR) DSR) RTS) CTS) DCD)
Forced Ports -/- -/- -/- -/- -/-
Forced Ports -/- -/- -/- -/- -/-Forced Ports -/- -/- -/- -/- -/-
Forced Ports -/- -/- -/- -/- -/-
Port 1 Port 2 Statistics
Port 1 Port 2 StatisticsPort 1 Port 2 Statistics
Port 1 Port 2 Statistics
Mp) mode 64K 64K FW/HW Rev...1.0/0.8
Mp) mode 64K 64K FW/HW Rev...1.0/0.8Mp) mode 64K 64K FW/HW Rev...1.0/0.8
Mp) mode 64K 64K FW/HW Rev...1.0/0.8
Sp) scram/hdlc inv N/N N/N Battery.....OK
Sp) scram/hdlc inv N/N N/N Battery.....OKSp) scram/hdlc inv N/N N/N Battery.....OK
Sp) scram/hdlc inv N/N N/N Battery.....OK
Kp) clocking ST ST DTE Intf....V.35/RS-232
Kp) clocking ST ST DTE Intf....V.35/RS-232Kp) clocking ST ST DTE Intf....V.35/RS-232
Kp) clocking ST ST DTE Intf....V.35/RS-232
Gp) LOS lead NONE NONE Data bus....A
Gp) LOS lead NONE NONE Data bus....AGp) LOS lead NONE NONE Data bus....A
Gp) LOS lead NONE NONE Data bus....A
Ep) enable loop YES YES Tp) test and monitor BEC
Ep) enable loop YES YES Tp) test and monitor BECEp) enable loop YES YES Tp) test and monitor BEC
Ep) enable loop YES YES Tp) test and monitor BEC
Np) near loopback OFF OFF Pp) monitor leads and status
Np) near loopback OFF OFF Pp) monitor leads and statusNp) near loopback OFF OFF Pp) monitor leads and status
Np) near loopback OFF OFF Pp) monitor leads and status

Configuration Menu
3-2 Verilink User Manual
Menu Layout The fields in the DIU 2131 Configuration/Diagnostic Menu can be
viewed as groups of related functions.
The small letter pto the right of most commands is a placeholder
for the number of the port you want to access. For example, if you
want to enable the loopbacks for Port 1, enter “E1”. If you want to
enable loopbacks for Port 2, enter “E2”.
The upper portion of this display lists the configuration commands
and current DIU configuration settings. The lower portion lists the
diagnostic commands for the DIU 2131.
The screen above show Channels 1-12 assigned to Port 1 and
Channel 15 assigned to Port 2. It also shows the options available
after the user has entered the mode (M) command for Port 2.
The statistics area provides the following information:
The handshake control signals display area fields change to show
which ports, if any, are force high.
Assigning the
DIU to a CSU This assignment establishes the data path between the DIU and the
associated CSU using the data bus previously assigned in the CSU
Configuration Menu.
CAUTION
Any time the DIU bus assignment is changed in a CSU, all DIUs assigned to
that CSU need to be reassigned. To reconfigure them correctly, you must
re-enter the shelf and slot number for each DIU, even if the correct
numbers already appear on the screen.
To assign a DIU to a CSU in the node:
What type of interfaceis onPort 1 and Port 2,
DIU 2131 firmware and hardware revision numbers
Whether the battery power is “OK” or “LOW”
respectively
hich data bus you selected in the CSU Configuration Menu
Statistics
StatisticsStatistics
Statistics
FW/HW Rev
FW/HW RevFW/HW Rev
FW/HW Rev
1.0/0.8
1.0/0.81.0/0.8
1.0/0.8
Battery
BatteryBattery
Battery
OK
OKOK
OK
DTE Intf
DTE IntfDTE Intf
DTE Intf
V.35/RS-232
V.35/RS-232V.35/RS-232
V.35/RS-232
Lead Toggles DTR DSR RTS CTS DCD
Forced Ports 1/2 -/- -/- -/- -/-
In this example, DTR is forced highfor Ports 1 and 2. None of the other
signals are forced for any port.

Configuration Menu
Verilink User Manual 3-3
1. Select a related CSU, type “C” on the prompt line of the DIU
2131 Configuration/Diagnostic Menu.
2. Press the ENTER key. A new prompt line will appear requesting
a shelf number.
3. Enter the number of the shelf you wish to access, and press
ENTER. A second prompt line will appear, requesting you to
enter the slot number of the related CSU.
Setting DIU up
for Multiplexing Figure 5-2 shows how to set up the DIU 2131 configuration screen
for muxing.
Figure 3-2 DIU 2131 Configuration for Mux Mode
Since the Craft interface does not check for errors when you save a
configuration, validate the following:
Each DIU is assigned to the proper CSU (CSU command in DIU
menu).
The mode (56k or 64k) is correct for Port 1.
The channels used on the near end match those on the far end
in a point-to-point circuit. For example, if the near end uses
DS0s 1-6, the far end must also use DS0s 1-6. If you’re going
through a DACS, this may not apply.
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ------ DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
--- DIU 2131 CONFIGURATION/DIAGNOSTIC MENU ---
C) CSU [ 1,1 ]
C) CSU [ 1,1 ]C) CSU [ 1,1 ]
C) CSU [ 1,1 ]
T) timing source CSU
T) timing source CSUT) timing source CSU
T) timing source CSU
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..
Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..
Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. 02 .. .. .. .. .. .. .. .. ..
Lead Toggles DTR) DSR) RTS) CTS) DCD)
Lead Toggles DTR) DSR) RTS) CTS) DCD)Lead Toggles DTR) DSR) RTS) CTS) DCD)
Lead Toggles DTR) DSR) RTS) CTS) DCD)
Forced Ports -/- -/- -/- -/- -/-
Forced Ports -/- -/- -/- -/- -/-Forced Ports -/- -/- -/- -/- -/-
Forced Ports -/- -/- -/- -/- -/-
Port 1 Port 2 Statistics
Port 1 Port 2 StatisticsPort 1 Port 2 Statistics
Port 1 Port 2 Statistics
Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8
Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8
Mp) mode 64K 19.2K FW/HW Rev...1.3/0.8
Sp) scram/hdlc inv N/N N/N Battery.....OK
Sp) scram/hdlc inv N/N N/N Battery.....OKSp) scram/hdlc inv N/N N/N Battery.....OK
Sp) scram/hdlc inv N/N N/N Battery.....OK
Kp) clocking ST ST DTE Intf....V.35/RS-232
Kp) clocking ST ST DTE Intf....V.35/RS-232Kp) clocking ST ST DTE Intf....V.35/RS-232
Kp) clocking ST ST DTE Intf....V.35/RS-232
Gp) LOS lead NONE NONE Data bus....A
Gp) LOS lead NONE NONE Data bus....AGp) LOS lead NONE NONE Data bus....A
Gp) LOS lead NONE NONE Data bus....A
Ep) enable loop YES YES Tp) test and monitor BEC
Ep) enable loop YES YES Tp) test and monitor BECEp) enable loop YES YES Tp) test and monitor BEC
Ep) enable loop YES YES Tp) test and monitor BEC
Np) near loopback OFF OFF Pp) monitor leads and status
Np) near loopback OFF OFF Pp) monitor leads and statusNp) near loopback OFF OFF Pp) monitor leads and status
Np) near loopback OFF OFF Pp) monitor leads and status
Fp) far loopback OFF OFF A) Alarm Enable......NO
Fp) far loopback OFF OFF A) Alarm Enable......NOFp) far loopback OFF OFF A) Alarm Enable......NO
Fp) far loopback OFF OFF A) Alarm Enable......NO
[1,2] DIU 2131 >
[1,2] DIU 2131 >[1,2] DIU 2131 >
[1,2] DIU 2131 >
If the CSU is in a different shelf, you will
need a data bus extension kit. Remember,
you must re-enter the CSU if you make bus
change .
When using
consecutive
channels, 64K
Mode will
require B8ZS
in the CSU’s
network (F)line
coding.
Unless the
signal
isgoingthrough
a DACS,
channel
assignments
must match at
both ends of

Configuration Menu
3-4 Verilink User Manual
If you have Verilink equipment at the other end, make sure
that an Fp (far-end loopback) can be successfully done before
turning the circuit over to your customer.
NOTE: Errors in Dp (port), or Mp (mode) will cause Fp to fail.
Summary of
Commands A summary of the commands, their names, and their descriptions
is provided in the following table.
Table 3-1 Summary of DIU 2131 Menu Commands
Command Name Description
Ccsu Assigns a DIU 2131 to a CSU in the node.
T timing source This command either assigns a data port to be the timing
source or assigns the CSU to be the timing source. Port 2
cannot support tail-circuit timing.
Options are Port1, Port2, or CSU.
NOTE: Before using this command, you must select the
CSU’s timing source in the CSU Configuration Menu.
Also, if the TT clock from a DIU port will be used to provide
the timing source to a CSU or TIU for T1 transmit timing,
you must use the Ccommand to select TT (not ST or
inverted ST) for that port.
D port Assigns one or more available DS0 channel timeslots of a
T1 circuit to each data port of the DIU 2131.
The number of channels required by Port 1 depends on
what transmission mode you select (either 56 kbit/s or
64kbit/s) and the desired aggregate rate. Port 2 never uses
more than one timeslot.
Since the Craft interface does no error checking, you must
make sure that you do not assign the same channel to
different ports. Use the following format examples to enter
the desired channel(s) for Port 1: 1-6 or 1,3,5,7,9.
Mmode Establishes the data transmission mode for the data port
selected with the Dcommand.
Port 1 can be either 56kbit/s or 64kbit/s. Port 2 can be 64,
56, 38.4, 19.2, 9.6, 4.8, or 2.4 kbit/s.
S scramble data Scrambles the data stream by changing the ones density
before the data stream leaves the designated port.
Both the near and far DIUs must have this option set to Yes
(Y) for the data stream to be understood.
Kclocking Selects the proper data input clock for each data port of the
DIU.
• TT Terminal Timing: the data equipment
• ST Send Timing generated by the DIU
• INV-STInverted ST signal generated by the DIU

Configuration Menu
Verilink User Manual 3-5
The screen also provides selected “read-only” statistics. These
include the hardware revision, which firmware version is running,
what connector modules are attached to each port and what data
bus is being used for the DIU 2131.
G LOS lead Allows a Loss-of-Signal (LOS) alarm to be generated when a
dropped signal is detected on one of the selected options.
The options are DTR, RTS, and NONE.
• If you want an LOS alarm when DTR is dropped, enter 1.
• If you want an LOS alarm when RTS is dropped, enter 2.
•Ifyoudonot want LOS alarms to be generated at all, enter
3.
DCD Data Carrier Detect This is the voltage threshold determining that the T1 signal
is good.
DTR Data Terminal Ready DTR, DSR, RTS, and CTS are the DCE-DTE handshake leads.
When the handshake leads are not forced, DIU signals
“follow” DTE signals.
When a lead is forced, the signal is asserted (it’s “on”).
By default, the DIU signals are not forced high. Rather the
DIU follows the input state of the RTS and DTR leads. With
this option, the CTS and DSR follow RTS and DTR,
respectively. The DCD lead follows the associated CSU’s
LOF alarms state (DCD off in alarm). The enable state
forces the lead high.
DSR Data Set Ready
RTS Request To Send
CTS Clear To Send
Eenable loop Allows you to enable or disable the data channel loopback
(DTE) function on each data port of the DIU. If this function
is not enabled, you won’t be able to activate or deactivate
the specific loopbacks with the N(near loopback) or F(far
loopback) commands.
N near loopback Activates and clears a data channel loopback on the
currently accessed (near-end) DIU.
F far loopback Activates a data channel loopback at the far-end DIU 2131.
This command sends a loop-up code on the selected DIU
data channel to the far end. Upon receiving this code, the
far-end DIU activates the appropriate data channel
loopback.
T test and monitor BEC Initiates and monitors a DIU test pattern for errors.
Pmonitor leads and
status Shows the monitor leads and their status.
Command Name Description

Configuration Menu
3-6 Verilink User Manual
Table of contents
Popular Control Unit manuals by other brands

AWG
AWG 30277633 instruction manual

DELTA DORE
DELTA DORE DELTA 8000 BT installation instructions

GEM
GEM 543 eSyStep operating instructions

Whelen Engineering Company
Whelen Engineering Company WeCanX V2V installation guide

Mini-Circuits
Mini-Circuits RC8DAT-8G-95 user guide

Bosch
Bosch ICP-MAP5000-2 installation manual