VERIPOS LD7 Quick guide
VOSS: http://help.veripos.com
AB-V-MA-00560 Rev A8
vessel work area from the drop down options and click Apply:
Upon lock to the selected beam the Sync LED should be green.
NOTE
In most locations, more than one beam will be available. Different
beams carry corrections for different reference stations. A beam should
be selected which has the highest elevations and reference stations most
suited to the work area.
Enabling the LD7 for Veripos Services
Contact the Veripos Helpdesk to request a service enable quoting
your Unit ID, Service Access Licence (SAL) number and listing
services required e.g. Veripos Ultra with Standard.
Download a Service Notification Form from http://help.veripos.com
and use this when contacting the Veripos Helpdesk for an enable.
Tel. +44 1224 965900 email: helpdesk@veripos.com
NOTE
The sync indicator must be green in order for the Access code to be
received.
When the unit is enabled the ENB LED should be Green
Configuring data outputs from the LD7
Position and heading data (NMEAa or NMEAb) can be output on
Com ports 1 or 2 or via LAN from the LD7.
On the Web Browser go to the GNSS Tab and set the NMEA
Messages required for output.
For serial output, go to the LD7 I/O page and select the data streams
and baud rate required for Com ports 1 and 2.
Configuring data outputs from the LD7 (LAN)
Position and heading data (NMEAa or NMEAb) is also available for
output via LAN.
To output NMEA messages from the LD7, the IP address of the GNSS
receiver should be used. Note that this is different from the IP address
used to connect to the LD7 WebUI.
GNSS Rx IP Address
(192.168.0.127 default)
GNSS Rx IP Address
(192.168.0.127 default)
LD7 with Verify QC –LAN outputs
Configure the Verify QC PC network settings to an applicable IP address
and Subnet Mask for use with the LD7 (Control Panel/Network
Connections).
NOTE
The LD7 processor, GNSS and LBand receivers all have separate IP
addresses. Take into account when setting an IP address on the PC.
To determine or set the LD7, LBand and GNSS Rx IP Addresses use the
LD7 Web Browser.
Configure Verify QC inputs for Client Sockets with the following IP
Address and LAN ports;
LD7 with Verify QC - Serial Port outputs
You can view or amend baud rates, etc. by going to LD7 IO page in the
Web Interface.
NOTE
Baud Rates are user configurable. As a result users should check the Baud
Rate Settings using the LD7 Web Interface (see Configuring data outputs
section of this quick guide).
Asia, Australasia, Indian Ocean
East Asia, Australasia, Alaska
Asia, Indian Ocean, East Africa, Persian Gulf,
Caspian Sea
North Sea, Mediterranean Sea, Africa, Persian
Gulf, Caspian Sea
North America, Gulf of Mexico, South America
North America, Gulf of Mexico, South America
North Sea, Mediterranean Sea, Africa
Default COM port settings