
Safety Instructions and Regulatory Notices
BEFORE YOU START INSTALLATION OR USE OF THIS PRODUCT, CAREFULLY READ THESE INSTRUCTIONS
Directive
Unless express and prior approval by THOMSON in writing, you may not:
•Disassemble, de-compile, reverse engineer, trace or otherwise analyse the equipment, its content, operation, or functionality,
or otherwise attempt to derive source code (or the underlying ideas, algorithms, structure or organization) from the equipment,
or from any other information provided by THOMSON, except to the extent that this restriction is expressly prohibited by local law;
•Copy, rent, loan, re-sell, sub-license, or otherwise transfer or distribute the equipment to others;
•Modify, adapt or create a derivative work of the equipment;
•Remove from any copies of the equipment any product identification, copyright or other notices;
•Disseminate performance information or analysis (including, without limitation, benchmarks) from any source relating to the equipment.
Such acts not expressly approved by THOMSON will result in the loss of product warranty and may invalidate the user's authority to operate this
equipment in accordance with FCC Rules.
THOMSON disclaims all responsibility in the event of use that does not comply with the present instructions.
Environmental information - WEEE directive
Please help us protect the environment in which we live!
Safety Instructions
Climatic conditions
This product:
•Is intended for in-house stationary desktop use; the maximum ambient temperature may not exceed 40°C (104°F).
•Must not be mounted in a location exposed to direct or excessive solar and/or heat radiation.
•Must not be exposed to heat trap conditions and must not be subjected to water or condensation.
•Must be installed in a Pollution Degree 2 environment (Environment where there is no pollution or only dry, nonconductive pollution).
Cleaning
Unplug this product from the wall socket and computer before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for
cleaning.
Water and moisture
Do not use this product near water, for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement or near a swimming pool.
Transition of the product from a cold environment to a hot one, may cause condensation on some of its internal parts. Allow it to dry by itself
before re-starting the product.
Interface classifications
The external interfaceson the rear panel of the product are classified as follows:
•Phone, VoIP, FXS: TNV circuit, not subjected to over voltages (TNV-2)
•All other interface ports (e.g. Ethernet, 10/100Base-T/MDI(-X), USB, E1, ATMF-25, Console, Craft, etc.), including the low voltage power input
from the AC mains power supply: SELV circuits.
When using this product, always follow the basic safety precautions to reduce the risk of fire, electric shock and injury to persons,
including the following:
•Always install the product as described in the documentation that is included with your product.
•Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
•Do not use this product to report a gas leak in the vicinity of the leak.
This symbol means that your inoperative electronic appliance must be collected separately and not mixed with the household waste.The
European Union has implemented a specific collection and recycling system for which poducers' are responsible.
This appliance has been designed and manufactured with high quality materials and components that can be recycled and reused.
Electrical and electronic appliances are liable to contain parts that are necessary in order for the system to work properly but which can
become a health and environmental hazard if they are not handled or disposed of in the proper way. Consequently, please do not throw
out your inoperative appliance with the household waste.
If you are the owner of the appliance, you must deposit it at the appropriate local collection point or leave it with the vendor when buying
a new appliance.
•If you are a professional user, please follow your supplier's instructions.
•If the appliance is rented to you or left in your care, please contact your service provider.
WARNING
•The telephone Phone, VoIP, FXS port will be classified as a TNV-3 circuit when connected internally to the PSTN, FXO port, for
example, when the device is powered off.
•If the product is equipped with a USB interface (slave and/or master) or any type of connector with metallic shielding, then it is not
allowed to connect the telephone Phone, VoIP, FXS port with the PSTN, FXO or the DSL, ADSL, SHDSL, VDSL, Line port by any means,
for example with an external telephone cable.
The intra-building port(s) of the equipment or subassembly is suitable for connection to intrabuilding or unexposed wiring or cabling
only. The intra-building port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces which connect to the
OSP or its wiring. These Interfaces are designed for use as intra-building interfaces only (type 2 or Type 4 ports as described in GR-1089-
CORE, Issue 4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order
to connect these interfaces to OSP wiring.