3
Oxford Direct Vent / Natural Vent Gas Heater
30005123
The Oxford Direct Vent/Natural Vent Room Heater, Model
No. OXDV30NV, is a vented gas appliance listed to the ANSI
standard Z21.88-2009 and CSA-2.33-2009 for Vented Room
Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use
at High Altitudes.
The installation of the Oxford Direct Vent/Natural Vent Room
Heater must conform with local codes, or in the absence of lo-
cal codes, with National Fuel Gas Code, ANSI Z223.1/NFPA
54 — latest edition and CSA B-149.1 Installation Code. (EX-
CEPTION: Do not derate this appliance for altitude. Maintain
the manifold pressure at 3.5” w.c. for Natural Gas and 10.0”
w.c. for LP gas at maximum input.)
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
with other gases unless a certied kit is used.
The Oxford Direct Vent/Natural Vent Room Heater and its
individual shut-off valve must be disconnected from the gas
supply piping during any pressure testing of that system at
test pressures in excess of 1/2 psig (3.5 kPa).
The Oxford Direct Vent/Natural Vent Room Heater must be
isolated from the gas supply piping system by closing its in-
dividual manual shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or
less than 1/2 psig.
‘Direct Vent’ describes a sealed combustion system in which
incoming outside air for combustion and outgoing exhaust en-
ter and exit through two separate concentric passages within
the same sealed vent system. The system does not use room
air to support combustion. The Direct Vent system permits
the gas appliance to be vented directly to the outside atmo-
sphere through the side of the house or vertically through the
roof. Conventional venting systems (Natural Vent) take air
from the room for combustion and vent the exhaust vertically
through the roof to the atmosphere.
This appliance is approved for bedroom installations in the
U.S. and Canada.
This appliance may be installed in an aftermarket* manufac-
tured (mobile) home, where not prohibited by state or local
codes.
The Oxford Direct Vent/Natural Vent Room Heater, when in-
stalled, must be electrically grounded in accordance with lo-
cal codes or, in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70, (latest edition), or of the cur-
rent Canadian Electrical Code C22.1.
Fuels used in gas, woodburning or
oil red appliances, and the products of combustion of such
fuels, contain chemicals known to the State of California to
cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
Completion of sale, nor for purpose of resale, from the
manufacturer.