Dear Customer,
Congratulations on purchasing this equipment. Please read
this manual carefully and take care of the following hints to
avoid damages. Any failure caused by ignoring the items and
cautions mentioned in the instruction manual is not covered
by our warranty and any liability.
CONTENT
Safety Instructions 3
Installation 5
Operation 7
TECHNICAL DATA 8
Troubleshooting 9
CleaningandCare 10
Hintson Disposal 10
DECLARATION OFCONFORMITY
This product is conform to the following European
Directives:
2014/30/EU (EMC)
2014/35/EU (LVD)
2011/65/EU (RoHS)
2009/125/EC (ErP)

3
EN
SAFETY INSTRUCTIONS
•
Thankyoufor purchasing this cooker hood. Please readtheinstructionmanual
carefully before you use the cooker hood, and keep it in a safe place.
•
Theinstallationworkmust be carriedoutby a qualifiedelectricianorcompetent
person. Before you use the cooker hood, make sure that the voltage (V) and the
frequency (Hz) indicated on the cooker hood are exactly the same as the voltage
(V) and thefrequency(Hz) in your home.
•
Themanufacturerandtheagentwill notbearany responsibilityforthedamage
caused by inappropriate installation and usage.
•
Never let children operate the cooker hood.
•
Thecookerhoodisforhome use only.Itisnotsuitable forbarbecues,Roast shop
andcommercialpurposes.
•
Thecooker hood and its filter mesh should be cleaned regularly in order to keep it
in good working order.
•
Before cleaning, switch the power off at the main supply.
•
Clean the cooker hood according totheinstruction manual and keepthe cooker
hood from the danger of burning.
•
Prohibit putting the cooker hood by fire.
•
Ifthereisanyfaultwiththeappliance,pleasecalltheservicedepartmenttorequest
a service engineer.
•
Thisappliance canbe usedbychildren aged from 8years andaboveand persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledgeiftheyhavebeengivensupervisionorinstructionconcerninguseof
the appliance in a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
•
Ifthesupplycordis damaged,itmustbereplacedby themanufacturer,itsservice
agent or similarly qualified persons in order to avoid a hazard.
•
Theinstructionsshallstatethesubstanceof thefollowing:thereshallbeadequate
ventilationof the room when the rangehood is used at the same time asappliances
burning gas or other fuels (not applicable to appliances that only discharge the air
back into theroom).
•
Donotflambé undertherangehood.Accessiblepartsmaybecome hotwhen used
withcookingappliances.
Important Hints on Installation
•
Theairmustnotbe dischargedintoaflue thatisusedfor exhaustingfumesfrom
appliances burning gas or other fuels (not applicable to appliances that only
discharge the air back into the room).
•
Regulations concerning the discharge of air have to be fulfilled.

4
EN
Important notes about the extraction mode
Open flue combustionequipment(for example,gas, oil, woodorcoal-firedheaters,
tankless water heaters, water heaters) pulls combustion air from the room and runs
itthroughan exhaustpipeorchimneytotheoutside.In the extractionmode, indoor
airisremovedfromthekitchenandtheadjacentrooms-withoutsufficientairintake
thiscreatesavacuum.Toxicgasesfromthechimneyorextractionfluecantherebybe
suckedbackintotheliving spaces.
•
Always ensure that a sufficient supply of fresh air is guaranteed and that the air can
circulate.
•
An air supply / extractor box alone does not ensure compliance with the limit
value.
Safe operation is only possible when the negative pressure in the room where the
applianceislocateddoesnotexceed4Pa(0.04 mbar).Thiscanbeachievedwhen
theairrequiredforcombustioncanflowthroughopeningsthatarenotclosable,
forexampleindoors,windows,inconjunctionwithanairsupply/extractorboxor
through other technical measures. Inany case, consult aqualifiedchimney sweep
who
can assess the entire ventilation of your house and propose appropriate
measures for
adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted operation is
possible.
W
ARNING
Fir
e
ha
z
ar
d
fr
om
fl
ying
sparks.
Only
install
equipment
on
a
fi
r
eplace
for
solid
fuels
(for
example,
wood
or
coal),
if
a
closed,
non-removable
cover
is
available.
W
ARNING
Risk
of
poisoning
fr
om
exhaust
gases
suck
ed
back.
Never
oper
ate
th
e
device
in
extr
action
mode
simultaneously
with
an
open
flue
appliance
when
th
er
e
is
not
adequate
airflow
guar
anteed.


6
EN
Ceiling Installation
Sawaholeintheceilingaccordingto
the dimensions of the extractor hood.
Slide the extractor hood into the
opening.
Ceiling
Brackets
Hood
Pushtheextractorhoodupwardsuntilthebracketsengagein thefalseceiling.Ifyou
do not engage, use a screwdriver to pierce the four holes in the lower corners of the
hood.
Thebracketsshouldbeadjustedso
that
the lower edge of theextractor
hoodis
flushwiththeceiling.Screw4
screws
through the four holes in the
lower
cornersofthehood.
Note
:
T
h
e
ventilation
pipe
must
be
installed
af
ter
adjusting
th
e
extr
actor
h
ood.

7
EN
•When mounting a non-return valve, it must be ensured that the valve can be opened
freely. If the valve cannot be opened freely, it can reduce the suction power and
increase the noise from the extractor hood.
•If the extractor hood is used for recirculation and there is no external ventilation
(exhaust air), it is important that the ventilation is not blocked or impaired, as this
can damage the extractor hood, reduce capacity and increase noise. In addition,
no non-return valve can be installed in recirculation mode.
OPERATION
Control Panel and Button Functions
Switch the engine on and off.
The motor runs at low speed.
The motor runs at medium speed.
The motor runs at high speed.
Switch the light on and off.
Setting the Lighting Colour
In standby mode, press and hold the LIGHT button to adjust the illumination color.
Use the button (3) to adjust one of the following light colors. The lights will show the
corresponding number (L1-L9):
Display Colour Display Colour
L1 White L6 Purple
L2 Red L7 Orange
L3 Green L8 Cyan
L4 Blue L9 Yellow-green
L5 Yellow

TECHNICAL DATA*
Ceiling Cooker hood
Stainless steel + Glass
90.00
Touch + Remote
Optional
51.4 kW/h
D
9.7
E
4.0 lux/W
G
69.1 %
D
411.1 m3/h
0.40 W
0.38W
Type
Material
Installation-width in cm
Ceiling installation
Control Type
Recirculation
Annual energy consumption
(AEChood) Energy efficiency category
Fluid dynamical efficiency (FDEhood)
Fluid dynamical efficiency category
Lighting efficiency (LEhood)
Lighting efficiency category
Grease separation
Grease separation category
Air flow **
Maximum air flow Qmax
Air flow at boost setting
A-rated noise emission **
Power consumption off (Po)
Power consumption standby (Ps) Power
consumption lighting system (Wl)
Connected load
Illuminant
Power consumption per illuminant unit
Voltage / frequency
Height adjustment in cm
Grease filter / material / dishwasher-
proof Carbon filter ***
Installation material
Instruction manual
Dimensions appliance H*W*D in cm
Weight net / gross in kg 15.30 / 17.90
317.2 m3/h 411.1 m3/h
N/A
54 dB 59 dB
10.0 W
85W
/ LED
2*5 W
220 - 240 V AC / 50Hz
optional
20*32.00*90.00
20
aluminium
2
8
EN


10
CLEANING AND CARE
Monthly Cleaning for Grease Filter
Clean thefilter every month can prevent any risk of fire. Thefilter collects grease,
smokeanddust,sothefilterisdirectlyaffectingtheefficiencyofthecookerhood.Ifnot
cleaned, the grease residue (potential flammable) will saturate on the filter. Clean it with
household cleaning detergent.
Annual Cleaning for Activated Filter
Applysolelytounitthatinstalledasa recirculationunit(notventedtotheoutside).
This filter traps odours and must be replaced at least once a year depending on how
frequent the cooker hood used.
Replacing Bulbs
1 Switchtheunitoffandunplugtheappliance.
2 Removethelamp coverbyunscrewingthe2screws.
3 Unscrew the incandescent bulb. Replace with the same type and rated bulb.
HINTS ON DISPOSAL
According to the European waste regulation 2012/19/EU this
symbolontheproductoron itspackagingindicatesthatthis
productmay notbe treatedas householdwaste.Insteadit should
be takentotheappropriatecollectionpointforthe recyclingof
electricalandelectronicequipment.By ensuringthisproductis
disposedofcorrectly,youwillhelppreventpotentialnegative
consequencesfortheenvironmentandhumanhealth,which
couldotherwisebecausedbyinappropriatewastehandlingof
thisproduct.Formoredetailledinformationaboutrecyclingof
thisproduct,pleasecontactyourlocal council or yourhousehold
wastedisposalservice.
EN
This manual suits for next models
1
Table of contents
Other Viand PRO Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

Monogram
Monogram ZV830 installation instructions

Tomate
Tomate TOM 1151 Installation and user manual

Broan
Broan QP130BL instructions

NuTone
NuTone NRLE1 Series Installation use and care manual

Rinnai
Rinnai RH-L419-SS Operation and instruction manual

Bellini
Bellini BRA603CPX Installation & operation instructions

Whirlpool
Whirlpool UXT5230BDS user manual

Electrolux
Electrolux EFI 60011 user manual

Bosch
Bosch DFS097K50 Instructions for installation and use

CyClone
CyClone NA-930 Installation and operating instructions

Pando
Pando integralcooking E-217 installation manual

ELICA
ELICA CIRCLE WALL 350 Nero instruction manual