X819-03-01 Rev 102 V896MA Mounting Adapter Introduction •• 3

4•• Introduction X819-03-01 Rev 102 V896MA Mounting Adapter
Introduction
The information in this instruction manual covers the installation of Model V896MA Mounting Adapter for the
V896MSH Maximum Security Housing. This unit should only be installed by a qualified technician using
approved materials in accordance with national, state and local codes. Read this manual through completely
before attempting installation.
The V896MA Mounting Adapter is used when the V896MSH Maximum Security Housing is to be mounted to a
vertical surface, like a wall or square pole. Before installing the V896MA, refer to Instruction Manual X795 for the
installation of the V896MSH housing and observe all Notes, Cautions and Warnings listed there.
Installation
To mount the V896MA, follow the steps below. Refer to Figure 1.
Note: Be certain that the area behind the selected mounting location is clear of obstacles (such as studs,
electircal wiring, pipes, etc.) which would interfere with the mounting of the unit. Video, power, and control
cables should be routed to the selected mounting location.
Caution: Mount this unit to structural materials with sufficient strength to carry the weight of the entire
system, including housing and camera. Do not attempt to mount to drywall material or to a single
2 x 4-inch wall stud.
1. Position the mounting adapter upside down (with mounting holes and cable holes facing up) on a table.
Allow the mounting flange at the end of the adapter to overhang the edge of the table in order to permit the
adapter to lie horizontally and not be tilted.
2. Remove the ten (10) Phillips flat head screws securing the housing base plate to the housing.
Two rectangular gaskets are supplied with the V896MA Mounting Adapter. If the housing is to be installed
outdoors or in alocation subject to heavy moisture, use these gaskets in the installation as described below.
Units mounted indoors in dry areas do not require the gaskets.
3. Place the appropriate gasket on the mounting adapter, taking care to align the mounting screw holes.
Position the housing base plate over the adapter, aligning the holes in the housing, gasket and mounting
adapter. Refer to Figure 2.
4. Make holes through the gasket on the housing base plate and fasten the housing base plate to the
mounting adapter with six (6) 10-32 screws, flat washers and lock washers from the mounting adapter
accessory pack.
5. Reattach the housing base plate and mounting adapter to the housing with the ten (10) screws previously
removed.
6. Refer to Instruction Manual X795 and install the camera.
7. Lightly tape or glue the gasket that corresponds to the mounting flange on the mounting adapter into place
to make the next mounting procedures easier.
8. Refer to Figure 3 or use the mounting adapter itself as a template. Mark and drill the holes for the mounting
hardware and cut a cable routing hole.

X819-03-01 Rev 102 V896MA Mounting Adapter Installation •• 5
Warning: Before performing the following steps, verify that there is no power supplied to the cables that will
be handled in the next step. Failure to do so could result is severe injury or death.
9. Route video and power cables through liquid tight fittings to the mounting location.
10. While one installer holds the housing and mounting adapter assembly, a second installer should route the
cables into the open end of the adapter and into the housing. Secure the cables by tying a knot in each one
so that they cannot slip back through the cable access holes.
11. Fasten the mounting adapter securely to the wall or square pole using four (4) 1/4-inch (min.) hardware. If
the mounting surface is steel of other structural metal, use 1/4-20 bolts, nuts and lock washers. If the
mounting surface consists of wooden beams, use 1/4-inch lag bolts, at least 2-1/2 inches long.
Note: If it is necessary to mount the V896MA to a round pole, special hardware is required.
12. Close off the four (4) mounting holes normally used for ceiling mounting with four (4) 1/4-20 screws, nuts,
and sealing washers supplied for the housing to be water resistant.

6•• Installation X819-03-01 Rev 102 V896MA Mounting Adapter
Figure 1
Exploded View

X819-03-01 Rev 102 V896MA Mounting Adapter Maintenance •• 7
Figure 2 Figure 3
Housing Base Plate/Gasket Dimensional Drawing
Maintenance
Model V896MA does not require any maintenance. Refer to Instruction Manual X795 for maintenance of the
V896MSH housing.

8•• Shipping Instructions X819-03-01 Rev 102 V896MA Mounting Adapter
Shipping Instructions
Use the following procedure when returning a unit to the factory:
1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of
the Vicon employee who issued the R.A.
Vicon Industries Inc.
89 Arkay Drive
Hauppauge, NY 11788
Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288)
For service or returns from countries in Europe, contact:
Vicon Industries (U.K.) Ltd
Brunel Way
Fareham, PO15 5TX
United Kingdom
Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322
2. Attach a sheet of paper to the unit with the following information:
a. Name and address of the company returning the unit
b. Name of the Vicon employee who issued the R.A.
c. R. A. number
d. Brief description of the installation
e. Complete description of the problem and circumstances under which it occurs
f. Unit’s original date of purchase, if still under warranty
3. Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection.
4. Mark the R.A. number on the outside of the carton on the shipping label.

X819-03-01 Rev 102 V896MA Mounting Adapter Technical Information •• 9
Technical Information
MECHANICAL
Mounting: Four 1/4-inch hardware appropriate for mounting surface.
Type: Wall or pole mounting of V896MSH housing.
Application: Indoor/Outdoor.
Cable Access: Hole provided for routing cable.
Dimensions: Height: 6.63 in. (16.8 cm).
Width: 3.0 in. (7.6 cm).
Weight: 2.9 lb ( 1.3 kg).
Construction: Steel.
Finish: Dark gray.

Vicon Industries Inc.
Corporate Headquarters
89 Arkay Drive
Hauppauge, New York 11788
631-952-CCTV (2288) 800-645-9116
Fax: 631-951-CCTV (2288)
&Infofax: 800-287-1207
Vicon Europe
Headquarters
Brunel Way
Fareham, PO15 5TX
United Kingdom
44/(0) 1489/566300
Fax: 44/(0) 1489/566322
Brussels Office
Planet II -Unit E
Leuvensesteenweg 542
B-1930 Zaventem
Belgium
322 712 8780
Fax: 322 712 8781
Far East Office
Unit 5, 17/F, Metropole Square
8 On Yiu Street, Shatin
New Territories,
Hong Kong
(852) 2145-7118
Fax: (852) 2145-7117
Internet Address: www.vicon-cctv.com
Table of contents
Other Vicon Adapter manuals