•Enter“ENGINEER’SCODE”:rsttimetype8times“1”(11111111factorypre-
set)andpressENTER(TheredLEDwillilluminate).
•Conrm“ENGINEER’SCODE”(typingagainthesame)ortypethenewcode
(4to8digits)thenpressENTER(Melody).PressingtwicetheENTERbutton
withoutchangingthe“ENGINEER’SCODE”,willexitfromtheprogramming.
•Entertheusercode(twodigits00to99)thenpressENTER(melody).
•Entertheaccesscode(4to8)digits.Therstdigitestablishwhichistherelay
affectedfromthecode:“1”=Relay1,“2”=Relay2and“0”=Relay1and2.I.e.
thecode“10543213”operatetherelay1.PressENTER(melody).
•ToenterothercodesgobacktothethirdstepotherwisepresstwiceENTER
button(melody).
•Enterthe“RELAY1”operationtime(2digits01to99I.E.05=5seconds,00=
remainopentime)orre-entertheexistingtimethenpressENTER(Melody).
•Enterthe“RELAY2”operationtime(2digits01to99I.E.05=5seconds,00=
remainopentime)orre-entertheexistingtimethenpressENTER(Melody).
•Thesystemisreadytouse(theredLEDwillbeoff).
instruction to return sYstem to preset enGineer’s
factorY code
•Turnoffpowertocodelock.
•Keep“ENTER” buttonpressedwhile turning backon the powertothe code
lock.
•Release“ENTER”button.
•Themastercodeisnowsetatfactoryengineer’scode“11111111”(8times“1”).
•Proceedwithprogrammingforanewsystem.
notes
•Toswitchoffanyrelaywhileoperating,typeintherelevantcodethenpress
the“CLEAR”button.
•Tooperaterelaystogether,setthesamecodeforeachrelay.
•Ifawrongcodeisentered,thesystemwilllockoutfor5secondswhichwillin-
creaseeachtimeawrongcodeisentered.Thesystemwilloperateonlywhen
thecorrectcodeisentered.
Inordertoachievethebestresultsfromtheschematicsdescribeditisnecessary
toinstallonlyoriginalVIDEXequipment,strictlykeepingtotheitemsindicated
oneachschematicandfollowtheseGeneralDirectionsforInstallation:
•Thesystemmustbeinstalledaccordingtonationalrulesinforce,inanycase
therunningofcablesofanyintercomunitmustbecarriedoutseparatelyfrom
themains;
•AllmultipaircablesshouldbecomplianttoCW1308specication(0.5mmtwist-
edpairtelephonecable.
Cablesforspeechlineandserviceshouldhaveamaxresistanceof10
Lockreleasewiresshouldbedoubledup(Lockreleasewiresandpowersup-
plywiresshouldhaveamaxresistanceof3 );
•The cable sizes above can be used for distances up to 50m. On distances
above50mthecablesizesshouldbeincreasedtokeeptheoverallresistance
ofthecablebelowtheRESISTANCESindicatedabove;
•Doublechecktheconnectionsbeforepowerup;
•Powerupthesystemthencheckallfunctions.
locK release BacK emf protection
A MOV (VARISTOR) must be tted across the terminals onAC lock release
(Fig.1A)andadiodemustbettedacrosstheterminalsonaDClockrelease
(Fig.1B) to suppress back EMF
voltages. Connect this compo-
nents to the lock releases as
showningures.