⬉⑤㒓㒘ⱘᦦᑻᖙ乏ヺড় IEC-60320 㽕∖ ,Ϩᔶ⢊ৃҹབϟ A1 ᠔⼎
㕢ࡴᣓ䗖⫼
In the United Statesand Canada the male plug isa NEMA5-15 style ( A2), UL Listed, and CSA
Labeled. For unitswhich are mounted on a desk or table, type SVT or SJT cord setsmay be used. For
unitswhich sit on the floor, only SJT type cord setsmay be used. The cord set must be selected according
to the current rating for your unit. Please consult the table below for the selection criteria for power cords
used in the United Statesand Canada.
⌆ᆊ䗖⫼
In Europe you must use a cord set which isappropriate for the receptaclesin your country. The cord set isHAR-
Certified, and a special mark that will appear on the outer sheath, or on the insulation of one of the inner conductors.
䗖⫼Ѣ㣅ⱘѸ⌕ᦦ༈⬉㓚⊼ᛣџ乍
FORYOURSAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.
IF THE FITTED MOULDED PLUG IS UNSUITABLE FORTHE SOCKET OUTLET THEN THE PLUG SHOULD BE
CUT OFF AND DISPOSED OF SAFELY.
THERE IS A DANGEROF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO AN
APPROPRIATE SOCKET.
If a new plug isto be fitted, please observe the wiring code asshown below.
If in any doubt, please consult a qualified electrician.
WARNING: THIS APPLIANCE MUST BE EARTHED.
IMPORTANT: The wiresin thismainslead are coloured in accordance with the following code:
Green-and-Yellow: Earth
Blue: Neutral
Brown: Live
If the coloured wiresof the mainslead of thisappliance do not correspond with the coloured markingsidentifying the
terminalsin your plug, proceed asfollows:
The wire which iscoloured GREEN-AND-YELLOW must be connected to the terminal in the plug which ismarked by
the letter E or by the Earth symbol or coloured GREEN or GREEN-AND-YELLOW.
The wire which iscoloured BLUE must be connected to the terminal in the plug which ismarked with the letter N or
coloured BLACK. The wire which iscoloured BROWN must be connected to the terminal in the plug which ismarked
with the letter L or coloured RED.
If you have any questionsconcerning which proper power cord to use, please consult with the dealer from whom you
have purchased the product.
㕢................. UL
ࡴᣓ............. CSA
ᖋ................. VDE
⨲ ................ SEV
㣅 ................ BASE/BS
᮹ᴀ ............... Electric Appliance Control Act
Cord Type Size of Conductors in Cord Maximum Current Rating of Unit
SJT 18 AWG
16 AWG
14 AWG
10 Amps
12 Amps
12 Amps
SVT 18 AWG
17 AWG
10 Amps
12 Amps