Vip-Vision ACCON-2C41 User manual

VIP Vision Access Controller
User’s Manual
Four-door One-way Compact Access Controller - ACCON - 2C41
Two-door Two-way Professional Access Controller - ACCON - 2P22
Four-door One-way Professional Access Controller - ACCON - 2P41
Four-door Two-way Professional Access Controller - ACCON - 2P42
Eight-door One-way Professional Access Controller - ACCON - 2P81

1
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018

2
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Important Safeguards and Warnings.......................................................................................................................3
1 Pre-Installation....................................................................................................................................................4
1.1 Installation Requirements &Notes...........................................................................................................4
1.2 Factory Default Settings..............................................................................................................................4
1.3 Components..................................................................................................................................................5
2 Dimensions........................................................................................................................................................ 10
3 Access Controller Installation......................................................................................................................... 12
3.1 System Diagram....................................................................................................................................... 12
3.2 Wiring Diagrams....................................................................................................................................... 13
3.3 Installation Step by Step..........................................................................................................................18
3.3.1 Setting up door lock jumpers (2P42 and 2P81 ONLY)........................................................ 18
3.3.2 Connecting door locks...............................................................................................................18
3.3.4 Connecting card readers, fingerprint readers and keypads................................................21
3.3.5 Connecting external alarm inputs (if necessary)...................................................................21
3.3.6 Connecting external alarm outputs (if necessary)................................................................ 22
3.3.7 Connecting power cable (2P series) / DC power adaptor (2C).......................................... 22
3.3.8 Connecting network cable........................................................................................................ 23
3.3.9 Connecting a backup battery (2P series only).........................................................................23
4 Smart PSS PC Console...................................................................................................................................24
4.1 Cybersecurity Recommendations.......................................................................................................... 24
4.2 Smart PSS Installation Step by Step.....................................................................................................25
4.2.1 Install the Smart PSS software................................................................................................ 25
4.2.2 Set password for the Smart PSS.............................................................................................26
4.2.3 Configure the PC network card (Ethernet card)....................................................................27
4.2.4 Add the access controller to Smart PSS................................................................................29
4.2.5 Synchronize time with PC.........................................................................................................31
4.2.6 Add users.................................................................................................................................... 33
4.2.7 Add fingerprints.......................................................................................................................... 35
4.2.8 Add door groups.........................................................................................................................36
4.2.9 Set time schedules.................................................................................................................... 38
4.2.10 Set holiday schedules............................................................................................................... 40
4.2.11 Assign user access levels........................................................................................................ 43
4.2.12 Configure doors..........................................................................................................................44
4.2.13 Log Records and Log Files...................................................................................................... 46
4.3 Advanced Functions.................................................................................................................................47
4.3.1 First card unlock........................................................................................................................47
4.3.2 Multi-card unlock.......................................................................................................................49
4.3.3 Anti-passback............................................................................................................................ 53
4.3.4 Inter-door lock............................................................................................................................54
4.3.5 Remote Verification................................................................................................................. 55
4.4 Events.........................................................................................................................................................59
5 Troubleshooting.................................................................................................................................................61
6 FAQs...................................................................................................................................................................63
7 After Installation................................................................................................................................................ 67
8Limited Warranty.............................................................................................................................................. 68
Table of Contents

3
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Important Safeguards and Warnings
Please read the following safeguards and warnings carefully before using the product in order to
avoid damages losses and body injuries.
Note:
Do not install the device at position exposed to sunlight or in high temperature. Temperature
rise in device may cause fire.
Do not expose the device to lampblack, steam or dust. Otherwise it may cause fire or
electric shock.
The device must be installed on solid and flat surface in order to guarantee safety under
load and earthquake. Otherwise, it may cause device to fall off or turnover.
Do not drop or splash liquids onto the device, and do not place container with full liquid on
the device to prevent liquid spilling from entering the device.
Do not block air vent of the device or ventilation around the device. Otherwise, temperature
in device will rise and may cause fire.
Use the device only within rated input and output range.
Install, assemble and disassemble by qualified personnel only.
Transport, use and store the product under appropriate temperature and humidity.
Warning:
Please use battery properly to avoid fire, explosion and other dangers.
Please replace used battery with battery of the same type.
Do not use power line other than the one specified. Please use it properly within rated range.
Otherwise, it may cause fire or electric shock.
Always connect a ground (earth) wire to the access controller’s chassis. Connecting the unit
without a protective ground, or interruption of the grounding can cause harm to the unit or to
the equipment connected to it. (2P series only)
Notice Information
All the designs, software and instructions here are subject to change without prior written
notice.
We would not be responsible for any damages and losses caused by improper operations
or installation. Do not allow non-authorized or unqualified personnel with any kind of
intervention to the product.
All trademarks and registered trademarks are the properties of their respective owners.
Please visit our website www.rhinoco.com.au for more information.

4
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
1 Pre-Installation
1.1 Installation Requirements & Notes
You must install the Smart PSS on a PC to add users, set up access rights and other functions
of the access controller.
You must change the IP address of the PC network card in order to control the access controller.
Refer to the Smart PSS User’s Manual for details.
1.2 Factory Default Settings
You must enter the correct IP/Domain Name, User Name and Password to add the access
controller to the PC platform.
The default settings are as follow:
IP/Domain Name: 192.168.0.2
User Name: admin
Password: 123456
*** If a dialogue box pops up asking for
maintenance password, enter
s4musvvcai

5
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
1.3 Components
Access Controller
Supports up to 100,000 NFC cards & stores up to 150,000
events
Supports high security NFC IC cards (13.56MHz)
Supports NFC card readers, keypads, fingerprint readers
and combinations
Supports Wiegand or RS-485 interface to NFC card readers,
keypads and fingerprint readers*(up to 4 doors)
Intelligent functions: First card unlock, Multi-card unlock,
Anti-pass back, Inter door lock, Remote verification
Supports up to 128 normal, period and holiday schedules
Door unlock push button inputs
Door open/close status sensing inputs
External alarm input(s)
External alarm output(s)
Internal alarms: Door time out alarm, intrusion alarm, duress
alarm and tamper alarm
Emergency features: All doors lock/unlock by two clicks
RTC (Real Time Clock) battery backup
RFID Card Readers & Keypads
Fingerprint + RFID Card Reader
Model: ACRDR-2SFC
Supports RS-485 protocol
RFID IC card (Mifare)
Supports cards and fingerprints
Blue backlight
Buzzer and Dual Colour LED indicator
Vandal-Proof Keypad + RFID Card Reader
Model: ACRDR-2MKC
Supports RS485 and Wiegand34 protocol
RFID IC card (Mifare)
Metal buttons with blue backlight
LED indicator

6
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Touch Keypad + RFID Card Reader
Model: ACRDR-2LKC
Supports RS485 and Wiegand34 protocol
RFID IC card (Mifare)
Sensitive touch keypad with blue backlight
Buzzer and Dual Colour LED indicator
Waterproof RFID Card Reader
Model: ACRDR-2PC
Supports RS485 and Wiegand34 protocol
RFID IC card (Mifare)
Buzzer and Dual Colour LED indicator
Waterproof IP67 rating
Slim Waterproof RFID Card Reader
Model: ACRDR-2SC
Supports RS485 and Wiegand34 protocol
RFID IC card (Mifare)
Buzzer and Dual Colour LED indicator
Waterproof IP65 rating
Slim Waterproof RFID Card Reader + Keypad
Model: ACRDR-2SKC
Supports RS485 and Wiegand34 protocol
RFID IC card (Mifare)
Buzzer and Dual Colour LED indicator
Waterproof IP65 rating

7
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Enrollment Readers
RFID Card Enrollment Reader
Model: ACENR-2C
Plug and Play, no driver is need
USB powered
Buzzer and LED indicator
Frequency: 13.56MHz
Fingerprint Enrollment Reader
Model: ACENR-2F
Plug and Play, no driver is need
USB powered
Resolution: 500 dpi
Door Release Buttons
Heavy Duty Door Release Button
Model: ACDSW100
Sandblasted Aluminium finish
3 output contacts (N.O, N.C, COM)
3A at 36VDC max. current rating
Mechanical design life (typical): 500,000 cycles
Dimensions: 86 x 50 x 28.9mm
Slim, Aluminium & Stainless Steel Door Release Button
Model: ACDSW101
Aluminium, stainless steel button
2 output contacts (N.O, COM)
3A at 36VDC max. current rating
Mechanical design life (typical): 500,000 cycles
Dimensions: 86 x 28 x 20mm

8
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Aluminium Door Release Button with LEDs and Timer
Model: ACDSW101
3 output contacts (N.O, N.C, COM)
Red/Green active status LEDs
2A at 30VAC/DC contact rating
Adjustable timer output 1~40s
Dimensions: 120 x 76 x 18mm
RFID Cards
RFID IC Card
Model: ACKEY103
High Frequency 13.56MHz RFID
Slim
Dimensions: 85.6 x 54 x 0.8mm
Electric Door Strikes
Mortise Electric Door Strike
Model: ACLOC100
Face Plate: Steel
Keeper Depth 9.6 mm
Lock Configuration: Fail-secure
Door Sensor: No
Lock Sensor: No
Power Input: 12VDC at 400mA
Dimensions: 160 x 31 x 31.4 mm
Surface Mount Electric Door Strike
Model: ACLOC101
Face Plate: Steel
Keeper Depth 9.6 mm
Lock Configuration: Fail-secure
Door Sensor: No
Lock Sensor: No
Power Input: 12VDC at 400mA
Dimensions: 108 x 50 x 31.4 mm

9
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Monitored Mortise Electric Door Strike
Model: ACLOC102
Face Plate: Stainless Steel
Keeper Depth: 12.7 mm
Lock Configuration: Convertible: Fail-safe / Fail-secure
Door Sensor: Yes
Lock Sensor: Yes
Power Input: 12VDC at 260mA
Dimensions: 165 x 31 x 40.2 mm
Monitored Multi-Voltage Mortise Electric Door Strike
Model: ACLOC103
Face Plate: Stainless Steel
Keeper Depth: 10.8 mm
Lock Configuration: Convertible: Fail-safe / Fail-secure
Door Sensor: Yes
Lock Sensor: Yes
Power Input: 12VDC at 260mA
Dimensions: 175 x 29 x 26 mm
Power Input: 12/24VDC at 280/140mA
12/24VAC at 170/85mA
Chrome Mortise Electric Door Strike
Model: ACLOC104
Face Plate: Chrome-plated steel
Keeper Depth 9.6 mm
Lock Configuration: Fail-secure
Door Sensor: No
Lock Sensor: No
Power Input: 12VDC at 400mA
Dimensions: 144.5 x 36.4 x 25 mm

10
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
2 Dimensions
Models: ACCON-2P22 ACCON-2P41
ACCON-2P42 ACCON-2P81
Unit: mm

11
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Model: ACCON-2C41
Unit: mm

12
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
3 Access Controller Installation
If this is your first time installing an access controller, we recommend setting it up on the bench
before installation, to familiarize yourself with the product.
If you are setting up more than one access controller, a network switch is needed. You must
use one network card (Ethernet port) for the access controller. If you need internet access,
please use another Ethernet port.
The communication between the access controllers and keypads, card readers requires Cat5
cables. This is to minimize errors.
Please install separate power supply for the door locks/electric strikes. Do not use the power
supply from the access controller, some electric strikes consume high current and may pull
down the system voltage when the door is unlocked.
Label all cables clearly will certainly reduce the troubleshooting time. Check wiring before
power up.
3.1 System Diagram
Recommendations:
1.
Connect devices with CAT5e cables.
2.
Use separate power supply for electric strikes.

13
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
3.2 Wiring Diagrams
Model: ACCON-2C41
Ports are defined as:
Port No.
Description
Port No. /
Indicator
Description
1
RS485 communication port
8
Card/fingerprint reader/keypad 2
2
Door 1 - 4 push button inputs
(PB1,PB2,PB3,PB4)
&
Door 1 - 4 sensor inputs
(SR1,SR2,SR3,SR4)
9
Card/fingerprint reader/keypad 3
3
No.3, 4 doors unlock
+door sensor
10
Card/fingerprint reader/keypad 4
4
External alarm input (ALM-IN)
/output
External alarm output
(OUT2+,OUT2-)
11
Reset button
5
DIP Switch - Use for reset to
factory default settings
12
DC 12V input (1A)
6
Network cable input (RJ-45)
13 - 16
Door lock/unlock indicators
7
Card/fingerprint reader/keypad 1
17
Power indicator

14
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Model: ACCON-2P22

15
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Model: ACCON-2P41

16
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Model: ACCON-2P42

17
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
Model: ACCON-2P81

18
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
3.3 Installation Step by Step
3.3.1 Setting up door lock jumpers (2P42 and 2P81 ONLY)
There are 8 relays and 8 jumpers for on the main board. The jumpers must be configured for
proper NO (Normally Opened) / NC (Normally Closed) output. Default setting is pin 1-2 shorted,
i.e. NO output - Power is supplied to the lock only when it is being unlocked. If you need NC
output, please short pin 2-3.
Relay and Jumper
PCB designator
2P42
2P81
JK5
Lock/Unlock control of door 1
Lock/Unlock control of door 1
J35
JK6
Lock/Unlock control of door 2
Lock/Unlock control of door 2
J37
JK7
Lock/Unlock control of door 3
Lock/Unlock control of door 3
J39
JK8
Lock/Unlock control of door 4
Lock/Unlock control of door 4
J41
JK9
Internal Alarm Output 1
Lock/Unlock control of door 5
J18
JK10
Internal Alarm Output 2
Lock/Unlock control of door 6
J22
JK11
Internal Alarm Output 3
Lock/Unlock control of door 7
J20
JK12
Internal Alarm Output 4
Lock/Unlock control of door 8
J24
3.3.2 Connecting door locks
a) Fail Secure type door lock connection - Supply
power to unlock.
Typical Fail Secure type door lock: Electric strikes, drop
bolts (fail secured type).
b) Fail Safe type door lock connection - Remove power to
unlock.
Typical Fail Secure type door lock: Electromagnetic locks,
drop bolts (fail safe type).
*** It is strongly recommended to use separate power
supply for door locks if more than 4 locks are
installed.

19
VIP Professional Access Controller User’s Manual - v3.00 Issued Dec.2018
Copyright © Cornick Pty. Ltd. 2018
3.3.3 Connecting exit buttons and door open/close sensors
All Exit button inputs are ACTIVE LOW, i.e. connect to GND(0V) to unlock the door.
All Door open/close sensors inputs are ACTIVE LOW, i.e. when a door is closed, the voltage
on the corresponding SR input (SR1, SR2… ) should become GND(0V). If the door is opened,
the corresponding SR input should be open circuit (No connection).
Model: 2C41
Model: 2P22
Model: 2P41
This manual suits for next models
4
Table of contents
Other Vip-Vision IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Roger
Roger MC16-SVC installation manual

GEM
GEM Gemprox-26M Specification sheet

RBH Access Technologies
RBH Access Technologies UNC100 Hardware manual

Pamex
Pamex Kapture KA-WR1S User Manual & Implementation Guide

2N
2N Access Unit Configuration manual

Conrad Electronic
Conrad Electronic KeyMatic CAC operating instructions