Viscoo IT-OUT251 User manual

English
User Manual
2-Wire Video Outdoor Station
IT-OUT251 IT-OUT251-F
1
4 5 6
98
0 #
7
2 3
*
1
4 5 6
98
0 #
7
2 3
*
IT-OUT251(-F) V1 140526


Contents
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Door Station Mounting......................................................................................... 2
4.System Wiring and Connections ......................................................................... 4
5. Functions Setting Up .......................................................................................... 8
6.Power Supply Instructions................................................................................... 16
7.Unlock Operations............................................................................................... 16
8. Precaustions....................................................................................................... 17
9.Specications ...................................................................................................... 17
10.Cables Requirements........................................................................................ 18

-1-
1.Parts and Functions
DT601F/KP Side View Mounting box
220 mm
120 mm
Rainy Cover
DT601/KP
1
4 5 6
98
0 #
7
2 3
*
Camera Lens
Touch Sensitive
Digital Keypad
Speaker
Nameplate
Call Button
Microphone
93 mm
30 mm
182 mm
1
4 5 6
98
0 #
7
*
2 3
Night Light
1
4 5 6
98
0 #
7
2 3
*
Camera Lens
Speaker
Touch Sensitive
Digital Keypad
Nameplate
Call Button
Microphone
Night Light
Screws for panel
mounting
1
4 5 6
98
0 #
7
2 3
*
2.Terminal Descriptions
1 2 3
Lock Control Jumper
BUS
PL
S+ S-
Main Connect Port

-2-
3.Door Station Mounting
1 2
43
Drill holes in the wall to match the size of
screws and attach the rainy cover to the wall.
Attach the panel to the rainy cover Use the screwdriver and the screw
to fix the panel
Connect the cable correctly
DT601/KP Mounting
•Lock Control Jumper: To select the lock type.
•Main Connect Port: To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
•PL: External lock power input, connect to the power positive(power +).
•S+: Lock power(+) output.
•S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).

-3-
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
DT601F/KP Mounting
1 2
43
Drill a hole in the wall to match the size of the
mounting box and attach to the wall.
Attach the panel to the mounting box and
use screws supplied to fix the panel
Connect the cable correctly
Placing Name Label
Use a screwdriver to unscrew the screw, and cock the host , then Placing Name Label.

-4-
Basic Connection
4.System Wiring and Connections
-
+
AC~
monitor
DPS PS4
L1 L2 PL S+ S-
Electric Lock Connection
EB
*
LOCK
BUS PL S+S-
Jumper position in 2-3
1 2 3
Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type
should be used.
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button(EB).
4. The Unlock Mode Parameter of Monitor
must be set to 0 (by default).

-5-
LOCK
Take off the Jumper
POWER
SUPPLY
BUS PL S+S-
Unlock parameter setting(set in monitor)
1.Touch item on main
menu page.
2.Touch the screen anywhere
and hold for 2s.
3.Touch Installer setup item
4.A digital keypad and setting
instructions will be showed.
Manual
Monitor
Monitor
Memory
Playback
Album User Setup
09/30/2010 Thu.16:41
Close
Intercom Multimedia
About
?
H/W : --- a1.3
S/W: V17.11.418.00
Local addr: ---
Unlock timing: ---
Video standard: -
UI-CODE: ---
MCM-VER.: ---
Updated: ---
Home
Installer
setup
Caliber
TouchScreen
Code Number:[----]
[0010]#:Remove all remote control
[0011]#:Add remote control
[8000]#:Set as master unit 0
[8001]#:Set as slaver unit 1
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8004]#:Set as guard unit
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8007]#:Panel off as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8009]#:Date format:DD/MM/YYYY
[8010]#:Set lock mode to 0
[8011]#:Set lock mode to 1
[8021]~[8029]
#Set the lock time of 1~9s
Multi language settings:
---
1
4
78
0
9
6
5
23
Cancel
Installation settings:
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according
to the lock.
2. The inside relay contact is restricted to AC or DC
24V/1A.
3. The jumper must be taken off before connecting.
4. Setup the Unlock Mode of Monitor for different
lock types.
•Power-on-to-unlock type:Unlock Mode=0
(by default)
•Power-off-to-unlock type:Unlock Mode=1
Note:
1.must connect IT-OUT251(-F) correctly before setting.
2.the parameter will be saved in IT-OUT251(-F) automatically,so you need only set on one monitor.
3.the above diagram is t for icon menu series monitors only, to text menu series monitors,please refer to
the corresponding user manual.

-6-
Multi Door Stations Connection
85~260VAC
DT-DPS PS5
monitors
DIP=on,off,off
DBC-4S
A B C D
OFF
ON
Impedance
switch
1# Camera2# Camera3# Camera4# Camera
L1 L2 PL S+ S-L1 L2 PL S+ S-
L1 L2 PL S+ S-
L1 L2 PL S+ S-
(Device Address:3) (Device Address:2) (Device Address:1) (Device Address:0)
Basic IN-OUT Wiring Mode
Multi Monitors Connection
Code=0, DIP-6=off
1 2 3 4 5 6
ON
Code=15, DIP-6=on
1 2 3 4 5 6
ON
Code=14, DIP-6=off
1 2 3 4 5 6
ON
monitor
Code=1, DIP-6=off
1 2 3 4 5 6
ON
monitor
monitormonitor
85~260AC
DPS PS5
1
4 5 6
98
0 #
7
2 3
*
(Device Address:0)

-7-
With DBC-4S Wiring Mode
85~260AC
DPS PS5
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=15, DIP-6=on
Code=13, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=14, DIP-6=on
Code=12, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=3, DIP-6=on
Code=1, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=2, DIP-6=on
Code=0, DIP-6=on
OFF ON
OFF ON
monitor
monitor
monitor
monitor
monitor
monitor
monitor
monitor
DBC-4S
A B C D
DBC-4S
A B C D
Impedance
switch
Impedance
switch
DIP=on,off,off
DIP=on,off,off
1
4 5 6
98
0 #
7
2 3
*
(Device Address:0)
NOTE:Here we take DT27(the monitor) for example.
This manual suits for next models
1
Table of contents