Installation and cabling features
Connections
Step 1-Mounting
Turn off or disconnect all equipment power sources.
Step 4- Composite Input
Used to input composite signal
(PAL, NTSC, SECAM compatible).
Step 3-SDI Input
Used to connect the SDI source such as digital
camera, broadcasting device. SDI input is an
optional module of VSP 516S, based on the
standard VSP 516.
Note
Step 6-DVI input
Input the signal from computer,
DVI signal generator and so on.
Step 7-Component input
Used to input signal from DVD
Or media player; Input signal are R/Pr G/Y B/Pb
from left side if check from back panel.
Step 5-S-Video input
Used to input S-Video signal
(PAL, NTSC, SECAM compatible).
Step 8-VGA input
Input from computer or VGA
source, such as PC or laptop.
Connect to the monitor or LED control
system which has DVI interface.
Step 10-DVI output
Step 11-VGA output
Connect to the monitor, projector and
so on.
2
3
4
5
19
123
~
24
25
26
29
30
31
21
SDI input BNC connector
15 16
18
17
28
~
~14
20
Mini Switches
LAN RJ-45 port
USB control port
RS232 control port
Audio input connector
TX Card Power Connector
TX Card DVI Input Connector
Composite input BNC connector
S-Video (DIN 4) Input connector
DVI (DVI-I) Input Connector
Component Female BNC Connector
DSUB 15-pin VGA Output Connector
Audio output connector
DVI Output Connector
33
34
32 DSUB 15-pin VGA Output Connector
Power Switch Button
Power Cord Connector IEC-3
Step 2-Audio Input
Used to input audio signal from Players
with audio output, such as DVD.
Step 9-Audio output
Connect to the audio Amplifier or audio
player.
Step 12-USB connector
Connect VSP516 with PC by USB cable
for control.
This guide provides quick start instructions for an experienced
installer to set up and operate the VSP 516.

VSP 516 Quick Start
Rev 1.0
Page 2 of 3
Step15- Power
Plug in power cord which has IEC connector, VSP 516
support AC power from 85 to 260 VAC,50-60Hz,
which means world wide compatible.
Step 13-LAN(Ethernet) port
Use twist CAT5 cable to connect to LAN port, user can
control VSP 618 based on default IP address:
192.168.0.100. User can also change the IP address by
RS 232 or USB.
Twist CAT5 should be one end in T568A, and another
end in T568B standard.
LAN(Ethernet) port is not for standard configuration.
Step 1-Input Switch
Pin End 1
Wire Color End 2
Wire color
1White-green White-Orange
2Green Orange
3White-Orange White-green
4Blue Blue
5WhiteBlue White-blue
6Orange Green
7White-Orange White-brown
8Orange Brown
Crossover Cable CAT5 is
wired as
T568A at
one end and
T568B at the
other(Tx and
Rx pairs
reversed) is
crossover.
T568A T568B
RJ-45
Connector
Pins
Step 14-Serial port
Use RS232 to RJ11 cable to connect a control system
or computer to the back panel RJ11 port and the other
end on RS232 port. RS232 to RJ11 cable as following
definition. RS-232 Funtion
2TX Transmit
3RX Receive
5GND Signal Ground
7--- Not used
8--- Not used
Pin RS-422 Funtion
TX- Transmit(-)
RX- Receive(-)
GND Signal Ground
RX+ Receive(+)
TX+ Transmit(+)
Insert Twisted
Pair Wires
RS232/RS422
Connector
Insert Twisted
Pair Wires
RJ11 Connector
RJ-11 Funtion
1
TX Transmit
2RX Receive
3GND Signal Ground4
--- Not used
Pin
Local control -- Front Panel Operation
VSP 516 supports eight inputs: CV1, CV2,CV3,
SVideo,VGA,YPbPr,DVI (HDMI 1.3 compatible) ,SDI
(VSP 516S only). Push each source button, will switch to
each source input, and display on the target monitor or
display system its input. For HDMI input, please use
HDMI to DVI cable to input from source.
NOTE
When there is not video or graphic input for the
current input, and user switch to that input, the
last frame image of the last input will keep on display.
Step 2-Scale
Push Scale button and go into scale setting menu. Use UP
or DOWN to go to Horizontal size, Vertical size,
Horizontal position, Vertical position setting page, and
push SEL to decide to set, and use UP or DOWN to
change the size or position value. Push SEL to send and
exit from the setting.
NOTE Keep pushing UP or DOWN button, the value of
the size or position will change faster and faster
during setting values.
Rate of change will be from 1 to 10 and to 100.
Powering Up
Push power button switcher to ON position. LCD
module on the front panel will show Video Processor
and VSP 516 model information, and go into self
verification before it load the last setting configuration
data and send the processed image to the target display
or device. For the first time running, CV1 input is the
default input source. User can operate with VSP 516
with local front panel and remote control with the
software run on the PC, remote control by RS232,
USBor TCP/IP.
Step 3-Output resolution
Push OUT button and use UP or DOWN button to go to
the right resolution for the monitor or display system, and
push SEL button to decide to go to the resolution.
VSP 516 supports 3 output formats:
800×600×60Hz ;1024×768×60Hz;1280×1024×60Hz;
Output resolution should be the same or larger than the
monitor or display system resolution.
NOTE
Step 4- Dual display
NOTE
For dual window mode, the following inputs
CV1,CV2,CV3,SVID,VGA,YPbPr,DVI,SDI
could be in each window, except two of CV1, CV2,CV3
and SVID could not be shown at the same time. DVI
and SDI could not show at the same time.
PushⅠ/Ⅱto switch between Single and Dual window
mode. Dual window means picture in picture layout
mode, user can customized each window size and
position for their application.
Step 5-Save
VSP 516 support 3 user saving mode. Push SAVE button
and SVAE1, SVAE2, SAVE3 buttons will light on
together, push any one of them to save the setting. After
that user can push each of them to call the setting.

Remote control -- Software Operation
VSP 516 Quick Start
Rev 1.0
Page 3 of 3
NOTE For setup
software,
please check with
user manual. And
install correct
language version to
work with right
language user
interface.
Step 2-Output resolution
Select output resolution from pull down
output list.
Step 3-Scale
User can scale the image with mouse drap and drop
operation; User can also scale by input the data into the
scale parameters and set.
Step 5-Save
Push “Save to flash”button and
select one of user mode to save, there
are three user modes in the list.
Save to flash
button, use to
save user mode
NOTE
SAVE1 setting is default user setting after VSP
516 power on.
All the user settings will gone after factory reset.
Step 4-Set up picture display mode
Under dual channels mode, user can set up
the pictures’size and position,
as following:
Push this button
to show PIP
CV1 is default small window, DVI is default
bigger window.
NOTE
Push this button
to show PBP.
Use the RS 232 port on the computer, baudrate should be
115200.
Step 1-Set up communication
Set COM Open COM Close COM
Step 1-Set Clock
How to add task in advanced settings
There are three steps to finish schedule.
Step 1. Set clock to sync to local time;
Step 2. Enable the schedule.
Step 3. Set timer parameter the schedule will run;
Step 4. Set the functions which run with schedule;
Step 5. Save to timer index;
Step 6. Run schedule
set the current time through
the options in the "clock"
function.
NOTE After factory reset, user need to set schedule
function again.
Step 2-Enable the schedule
User can save the schedule setting as timer index.
When the timer value is set to 1, the setting is stored
into index 1. If you want to set up more schedule
function, you can store in different index.
VSP 516 supports max 10 schedule functions.
The VSP 516 supports timer setting in date, hour,
minute and seconds.
When these steps were finished, click to complete
the "Task Scheduler".
User should enable the
schedule after the
config, otherwise the
function is not used.
Push start button and
when the button show as
it means schedule
function is enable.
Select to work in dual channel or
single channel display mode.
Users can scale the parameters
by input values or click the
down arrow to set the parameters to control the
location and size.
Click the button you can view the current
"mission plan" input, playback time, picture size,
location and other information.
Step 3-Set timer parameter
Step 4-Set function to run
User can set operating (display) mode, input
interface, scale for schedule function.
Select the input interface to work in display mode, if
display mode is dual channel, should click image 1
and image 2 page to select separately.
Step 5-Save to timer index
Step 6-Run schedule
Add task through “device schedule”under the
“video processor”menu.
User can add task schedule, and then device will switch
to the input, run the config settings according to the
schedule.
Other VISIO Media Converter manuals
Popular Media Converter manuals by other brands

Amperes
Amperes TD6240 instruction manual

epiphan video
epiphan video Webcaster x1 quick start guide

Moxa Technologies
Moxa Technologies NPort 5110A Quick installation guide

B+B SmartWorx
B+B SmartWorx IE-MultiWay user manual

Absolute Process Instruments
Absolute Process Instruments IsoSplitter APD 7393 quick start guide

Creative
Creative Sound Blaster X7 SB1580 user guide