This equipment has been followed with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try and correct the
interferene by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless repeater is free from physical defects in material and
workmanship under normal usage for one year from the date of purchase. If the product
proves defective during this one-year warrany period, Vision will replace it free of charge.
Vision does not issue any refunds. This warnnty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to : (1) damage to units
caused by accident, dropping or abuse in handling, or any negligent usage; (2) units which
have been repaired, taken apart, or modified by an unauthorized personnel; (3) units not
used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5)
transit damage, initial installation costs, removal cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
Installation & Operation Manual
ZR1202IN-5
ZR1202MY-5
ZR1202EU-5
ZR1202RU-5
ZR1202US-5
ZR1202IL-5
ZR1202KR-5
ZR1202HK-5
ZR1202JP-5
ZR1202BR-5
Z-Wave Repeater
Federal Communications Commission Statement
ZR1202
V0
1031003
6B1Z-12002
-3-
Introduction
Thanks for choosing the Vision’s repeater of the home automation device. This module is a
Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology) and is
fully compatible with any Z-Wave™ enabled network. Every main powered Z-Wave
enabled device acts as a signal repeater and multiple devices result in more possible
transmission routes which helps eliminate “RF dead-sports”
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-Wave™ enabled networks. This device take existing Z-WAVE signal, repeat and send it
to a longer range where it is too far away for the controller (supporting FLiRS devices).
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave™(ZM4102)
Frequency Range:
865.22MHz (ZR1202IN-5)
868.10MHz (ZR1202MY-5)
868.42MHz (ZR1202EU-5)
869.00MHz (ZR1202RU-5)
908.42MHz (ZR1202US-5)
916.00MHz (ZR1202IL-5)
979.70MHz (ZR1202KR-5)
919.80MHz (ZR1202HK-5)
920-928MHz(ZR1202JP-5)
921.42MHz (ZR1202BR-5)
Operating Range: Up to 200 meters
Operating Temp.: -15°C~ 60°C (5°F ~140°F)
Operating Voltage: 5V/DC
Current Consumption: 300mA(±50mA)
1pc
1pc
1pc
1pc
ZR1202 Repeater module
ZR1202 Repeater Bracket
Adapter (Optional)
Installation & Operation Manual
Z-Wave™ Command Class:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO
※Note: Suitable adapter specification:
-Micro USB Power Input
-Operating Voltage: 5V/DC
-Current Consumption: 500mA
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to the installation
guide of Z-Wave™ Interface Controller before installing ZR 1202 Repeater Module.
1. Fix the repeater under the vertical way as high as possible then insert the suitable Micro USB
Power Adaptor to the ZR1202 then it will go to the Learning Mode automatically. (The LED will
start flash which means the repeater has not been “Include”yet.)
2. For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into“inclusion”
mode and following its instruction to add the ZR1202 to your controller. To get into the “inclusion”
mode, the distance between module and controller is suggested to be in one meter. Press the
program switch on the ZR1202 three times in 3 seconds. The LED should stop flashing, if not,
please try again.
For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into
“exclusion” mode, and following its instruction to delete the ZR1202 from your controller. Press
the program switch on the ZR1202 three times in 3 seconds to be excluded.
Note: LED setting light will flash continuously in Exclusion condition.
For “Association”: Support one association group (5 nodes).
3. Use “Power Level Set”command for setting the strength of RF during one period.
4. Use “Power Level Test Node Set”command to test the direct signal for fixed node.
5. Support Repeaters for routing (FLiRS included)
6. Support Explorer Frame function
7. Press Program Switch for 5 seconds, the ZR1202 will reset back to factory default. (Remark: This
is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
8. Support OTA Firmware update from controller. Please refer to your controller manual. Once
OTAfunction success, please make sure to exclusive the device & inclusive again before use the
device.
5. Security enabled_ Z-Wavecontroller must be used to fully utilize the product.
6. Lifeline group used command :
{COMMAND_CLASS_DEVICE_RESET_LOCALLY,DEVICE_RESET_LOCALLY_NOTIFICATION}
★The ZR1202 operating range will be up to 200 meters open site under the
correct installation!!
(2)
(1)
Micro USB Power Input
Program Switch
Release the bracket:
(1) Press
(2) Slide down to release the bracket
-1-
-2-

This manual suits for next models

9

Other Vision Repeater manuals

Vision ZR1202IN User manual

Vision

Vision ZR1202IN User manual

Vision TECHCONNECT TC2-HDMIRPT User manual

Vision

Vision TECHCONNECT TC2-HDMIRPT User manual

Vision ZR1202RU User manual

Vision

Vision ZR1202RU User manual

Vision VIS_ZR1202 User manual

Vision

Vision VIS_ZR1202 User manual

Vision ZR1202EU User manual

Vision

Vision ZR1202EU User manual

Popular Repeater manuals by other brands

York Universal LINC485 installation manual

York

York Universal LINC485 installation manual

Topcom Ultra R112 user manual

Topcom

Topcom Ultra R112 user manual

Compaq Netelligent 1224 user guide

Compaq

Compaq Netelligent 1224 user guide

Detnov RTD-150T Quick installation and user guide

Detnov

Detnov RTD-150T Quick installation and user guide

UGMO UG1000 series Quick installation and start-up guide

UGMO

UGMO UG1000 series Quick installation and start-up guide

Vertex VXR-5000 user manual

Vertex

Vertex VXR-5000 user manual

Sepura SER8050 Installation and operation guide

Sepura

Sepura SER8050 Installation and operation guide

Entel RP510 user guide

Entel

Entel RP510 user guide

R-tron CDMA MINI user manual

R-tron

R-tron CDMA MINI user manual

Ltech LT-3060-8A instructions

Ltech

Ltech LT-3060-8A instructions

Neurona AX821 user manual

Neurona

Neurona AX821 user manual

D-Link DIR-505 Technical Support Setup Procedure

D-Link

D-Link DIR-505 Technical Support Setup Procedure

Ericsson DRC-200 Maintenance manual

Ericsson

Ericsson DRC-200 Maintenance manual

Interlogix POE303-EX-4P user manual

Interlogix

Interlogix POE303-EX-4P user manual

GE MASTR II Maintenance manual

GE

GE MASTR II Maintenance manual

Vertex Standard VXR-9000E operating manual

Vertex Standard

Vertex Standard VXR-9000E operating manual

Futurecom Mobexcom P25 user guide

Futurecom

Futurecom Mobexcom P25 user guide

VAF GV900W user manual

VAF

VAF GV900W user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.