manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Visionary
  6. •
  7. Light Fixture
  8. •
  9. Visionary VISB2-3CCT Series Instruction Manual

Visionary VISB2-3CCT Series Instruction Manual

This manual suits for next models

1

Other Visionary Light Fixture manuals

Visionary INSURGENT VISH2 Series Instruction Manual

Visionary

Visionary INSURGENT VISH2 Series Instruction Manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Lightolier LP200 specification

Lightolier

Lightolier LP200 specification

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier Lytespan 83ED17S specification

Lightolier

Lightolier Lytespan 83ED17S specification

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ATHENATM BATTEN
OPERATING
INSTRUCTION
MANUAL
ARCHITECTURAL LED BATTEN 32/50W
WITH 3CCT COLOUR CHANGING TECHNOLOGY
& FLICKER-FREE DRIVER
V1.00
REV 0
VISB2-XXXX-XX-3CCT
Introduction
Thank you for choosing Visionary International as your light-
ing provider. This operating manual provides information on
how the product functions and how to safely operate and
install the product.
Installing the product (Existing installation)
Any electrical work must conform with the Electricity Act
1992 including section 79, NZECP 50: 2004, Electricity
Act 1992 Section 80 and NZECP 51: 2004.
1) Disable power to the circuit that you are working on.
We highly recommend switching electricity off at the main
switchboard of the premises for added safety.
2) Remove the previous tting from the ceiling cavity being
careful not to damage the ceiling material. Ensure that there
is no remaining driver/transformer connected to the specic
lighting mains cable.
3) Gain access to the batten power supply and terminals by
using a medium sized at-head screwdriver and inserting it
into the marked divot at one end of the batten between the
upper and lower batten segments. (Illustration on right)
4) Feed the TPS cable through the center of the tting.
5) Use the supplied screws to fasten the batten to the ceiling
until sturdily in place.
4) Fully unscrew the three input terminals until the screws are
ush with the plastic holder above to prepare cable insertion.
5) Install the three cable colours into the appropriate slot in
the terminal block. Screw down each terminal screw rmly.
Live (Driver input) = Brown or red sheath colour (cable side)
Ground (Driver input) = Yellow sheath colour (cable side)
Neutral (Driver input) = Blue or black sheath colour (cable
side)
NOTE: Some previous installations have had the ground
cable cut off so the cable is not exposed. The NZECP
requires you ensure proper grounding as this is a Class
1 light tting.
6) Once all cables are installed, tighten the terminal screws
until the cables are fully fastened in the terminal block. Check
all cable cores are locked in place applying a light force on
the TPS cable. Please check to ensure there is no exposed
or unsheathed cable to ensure there is no undue electrical
risk.
7) Connect the upper side of the batten xture by pressing it
into the lower part of the xture that is already in place. You
should hear a click as it locks into place. Check around the
entire tting to ensure all sides are fully xed and the upper
and lower segments of the batten are ush.
Box Contents
1x Athena Batten
1x IP68 Rated gasket
2x Square Head screws for surface mount installation
2x GIB insertion nodules.
Dimensions
Usage areas
This product is designed and suitable for indoor use only in residential or commercial applica-
tions. The product is suitable for use in general lighting areas such as home living spaces and
indoor commercial spaces where the product is not exposes to impacts, excessive dust or any
water ingress. This product is not suitable for use in a parallel connection with unsuppressed
inductive loads or where there are known power quality issues. Doing so will void the product
warranty.
New Installations (requiring new wiring and/or new ceiling cutout)
The product must be installed by a fully licensed electrical contractor. Under New Zealand law,
a home owner or business that is not qualied to install electrical products cannot install Vision-
ary products that require new wiring. Visionary Technologies can assist you in nding a suitable
electrical contractor who is properly trained and experienced in installing Visionary products.
Contact us for more information.
DISCLAIMER
VISIONARY TECHNOLOGIES RESERVES THE RIGHT TO CHANGE PRODUCTS, INFOR-
MATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specications discussed
herein are for reference purposes only. All information discussed herein may change without
notice and is provided on an “AS IS” basis, without warranties of any kind. This document and all
information discussed herein remain the sole and exclusive property of Visionary Technologies.
No license of any patent, copyright, mask work, trademark or any other intellectual property
right is granted by one party to the other party under this document, by implication, estoppels or
otherwise.Visionary products are not intended for use in life support, critical care, medical, safe-
ty equipment, or similar applications where product failure could result in loss of life or personal
or physical harm, or any military or defense application, or any governmental procurement to
which special terms or provisions may apply. For updates or additional information about Vision-
ary products, contact your nearest Visionary office.
General Specications
Wattage 4ft | 1200mm - 32W
5ft | 1500mm - 50W
Output 4ft | 1200mm - 4000lm
5ft | 1500mm - 6500lm
Efficacy
Lamp + Driver
Up to 125lm/W
Delivered Lumens @ 50W,4000K,80CRI
Optic Options 1200
IP Rating IP40
IK Rating NA
Warranty 5 - Years
Parts & Labour Yes - 3-Years
CCT Options 3CCT
3000, 4000K, 5000K
Mount Options Surface Mount (Incl)
Suspension Kit
Lighting Engine >50,000hr L70 TM-21
Driver Class I
Connections Centre Cable Mount
Side Cable Mount Option
Accessories NA
Colour/s White
SDCM 3-Step | <3-SDCM
Input Connection 6mm Terminal Block
Pre-wired LED Driver