Vivanco WI 2602 User manual

BEDIENUNGSANLEITUNG
INSTRUCTION MANUAL
MODE
D’EMPLOI
WI 2202
WI 2602

1. General
This intercom system requires no wires, so there is no need for a link between this connected stations. All you need is a normal
plug socket (220
V/50
Hz) in each room where an intercom is to be installed.
Connection:
1.
2.
First connect the WI 2202 or WI 2602 intercom to the light circuit by inserting the Euro-plug into the plug socket
Switch on the WI 2202 or WI 2602 using the ON/OFF-knob.
3.
Set both intercoms to the same channel using the channel switch.
Possible applications:
3.
Selektive operation I:
4.
7.
8.
.-
.
.
‘-
-I
I
Normal’operation:
Alternate communication in both directions is possible.
Parallel operation:
If the two intercoms each are set to channel A or B respectively two speaking connections are possible
-
but not simultane-
ously. If channel B is in use, channel A can hear nothing and vice versa,
One station serves as the
)>master(c,
while the other three are
set
to
different channels. In this way each sub-station can be called
seperately.
Selektive operation II (WI 2602 only):
One station serves as the
)>master(c,
while the other three are set to different channels, In this way each sub-station can be called
seperately.
Continuous operation (supervision):
One station is set permanently to
)&ansmitc(.
This means that a continous check can be called seperately.
Synchronous supervision:
Intercom system with automatic switching allow the simultaneous supervision of several rooms, e.g. two children’s rooms.
Any station switching automatically to transmission blocks the others.
Automatic two-way communication (WI 2602 only):
Press the button marked
)>Autocc.
You can now speak consecutively without having to touch any more buttons. Please note that
the station requires approx.
l/2
a second to switch from
ntransmit(c
to
)lreceive<c
when changing direction.
Please note that unfavourable conditions can influence the quality of reception in the power supply. If this is the case, 2 or
3-
channel systems have the avantage that the reception can be optimised by switching to another frequency (channel).
.
.._
:
-.
-.
.
.
.
.
.
-,.
_..-_.

9
Phase-coupler
Should there be no connectiopn between the receiver and the transmitter, check both sets within the same room, i.e. on the
same power circuit. If a connection is made you must assume that the different power circuits. In this case consult an electri-
cian and have a
VIVANCO
PK 1 phase-coupler installed. This phase coupler ensures that the two power circuits are connected
to one another, allowing for connection via several phases.
. .
Technical Data: WI 2602 WI 2202
Modulation:
FM
channel a = 100
k?-iz
k
1
kHz
FM
Power connection: 220
V/50
Hz
Frequency:
115kHz+l
kHz
Loudspeaker/mike: low-Impedance
channel b = 115
kHz
&1
kHz
130kHz+l
kHz Weight:
approx. 660 g
channel c = 130
kHz
+
1
kHz
Dimension: 18 x
16
x
4,2
(BxLxH)
Output power HF:
approx.
3,5
mW approx.
3,5
mW
DBP-tested: G 400 302X TFW
Output power NF:
approx. 400 mW approx. 400 mW
)Subject to changes in the interests of technical
progressa
WI 2602
Operation elements
1.
2.
3.
4.
Power control lamp:
Lights up when the set is switched on.
Channel selection switch:
5.
6.
*
7.
,
Sliding switch to select channel. Two communicating stations must be set to the same channel.
Volume
control and ON/OFF switch:
Infinitely variable volume control and powe switch.
Contlnous transmlsslon:
If the button is pressed the station concern
i
d transmits continously, e.g. for the supervision of babies or old people.
-
Only
with WI 2202. For WI 2602 see 7. rautomaticu.
Speak button:
By pressing the speak button contact can be made with the receiving statiofl. Important: You can only speak in one direction
at once. When the speak button is pressed reception is not possible. Free-hand speaking is possible only using the automatic
function (WI 2602 only).
Call bunon:
The call button sets off an electronic sound in the receiving station as long at it is pressed. It is not possible to speak while the
call button is being pressed.
Automatic:
The WI 2602 has an automatic button with an LED display. If this acoustically-controlled automatic switching funktion is se-
lected the station transmits only when ctecrly audible sound are picked up.
Warranty
The high quality standard and careful
checkings
of our products enable us to grant you full
guarantee
for
a
period of
1 (one) year
starting from date of purchase. Therefore please keep your voucher carefully. Further warranty according to the corresponding
terms of our sole agency in your country.

_--
-_
Declaration of Conformity
We,
de Vivanco & Co.
(GmbH
& Co.)
Ewige Weide 15
D-22926 Ahrensburg
Germany
herewith confirm that the product:
Type: Intercom system
Model:
WI 2202
meets the requirements of the council of the European communities relating to
electromagnetic compatibility (Council Directive 89/336/EEC).
Technical Data: EN 50082- 1 1.1992
IEC
801-
2
9.1987
IEC
801-
3
1984
IEC 801-4 9.1987
This is to certify that on the basis of the Low-Voltage Directive (LVD) of the European Community the product
complies with the following standards: DIN VDE 0860 Teill
/
05.89
DIN VDE 0804 Teill
/
05.89
referred to in accordance with Articles 5 or 6 of the Low-Voltage Directive (LVD) relevant to this product.
The CE symbol is awarded to high-quality appliances which comply with the European Directive 89/336/EEC
or the EMVG (law relating to electromagnetic compatibility of appliances) and which offer the following
significant benefits:
’
Simultaneous and interference-free operation of adjoining appliances
l No unpermitted interference signals
’
High resistance to electro-smog
Ahrensburg. 26.1.1996
v
Authorized Signatory
Peter Zahari

Information about
wireless intercoms
Possible interference causes and how to solve them:
Short Function Test
Plug transmitter and receiver in a multiple-socket (as per drawing) Switch
on both sets. In case both operate perfectly now, the mains may be the
cause of the interference. In this case please address to your next after-sales
service or electrical specialist for installation of interference suppresstons.
Do not return your intercoms to the manufacturers before not being sure
whether the intercoms produce the interfering noises or the frequencies
in the mains.
Interference: More or less heavy rustle or crackle noise influence the
quality of reception.
Cause:
One
connecte.d
electric equipment supplies the interfering
noise.
Remedy:
Unplug all electric equipments. Connect same again, one
by one, till you get the interfering noise again. Now you
discovered the “producer”. An adapter (for domestic
appliances or TV) will solve this problem. Consider,
however, a slight constant background noise during the
transmission is normal as no mains works completely
noiseless.
Interference: You hear heavy noise although all equipments are
unplugged despite the intercoms (eventually reception of
other Intercoms).
Cause:
Interferences from outside enter in your domestic electric
circuit.
Remedy:
A specialist has to install a carrier-frequency filter or has to
alter the phases. In case you operate with multi-way-sets
first try to select another channel (frequency). This might be
already sufficient.
I
Interference:
No communication at all between the various intercoms
Cause:
Both sets operate on different phases
Remedy:
A specialist must install a phase coupler (VIVANCO PK 1) to
bridge the different electric circuits.
L
. de Vlvonco
&
Co
(GmbH
&Co )
Ewlge Welde
15
D
2070 Ahrensburg

AUESW~
DAZlJGEHtkT
de Vivanco
&
Co.
(GmbH
&
Co.)
Postfach 1320
l
Ewige Wide 15
2070 Ahrensburg
Tel.:
04102/518-O
Telex: 2189 856
dvcd
INS271
M3VI
(Rev.
1)
,
Table of contents